Whynter ARC-1030WN User manual

Whynter NEX Inverter Dual Hose Portable Air Condioner
with Wi-Fi & LCD Remote
Congratulaons on your new Whynter product. To ensure proper operaon, please read this Instrucon
Manual carefully before using this product. Keep this manual in a safe place for future reference.
MODEL: ARC-1030WN / ARC-1230WN / ARC-1230WNH

DISPOSAL INFORMATION
Thank you for choosing Whynter. Please follow the instrucons provided in this user manual
to obtain the very best performance from your steam oven. We trust that your Whynter
steam oven will provide the performance and reliability that we stand for.
Please keep this user manual in a safe place for future reference.
This symbol on the product or its packaging indicates that this appliance cannot be treated
as normal domesc trash, but must be handed in at a collecon point for recycling electric
and electronic appliances. Your contribuon to the correct disposal of this product protects
the environment.
Further informaon about the recycling of this product can be obtained from your local
municipal authority.
Page 2

Table of Contents
PAGE
SAFETY PRECAUTIONS 4
SAFETY COMPLIANCE 5
PREPARATION 6
INTRODUCTION / TECHNICAL DATA 7
ACCESSORIES 8
WINDOW KIT INSTALLATION 8 - 10
CONTROL PANEL 11 - 12
OPERATION INSTRUCTIONS 13 - 14
REMOTE CONTROL 15 - 16
CLEANING AND MAINTENANCE 16 - 17
TROUBLESHOOTING 18 - 19
WARRANTY 20
Page 3

SAFETY PRECAUTIONS
Read Safety Precauons Before Operaon and Installaon
To prevent death or injury to the user or other people and property damage, the following instrucons must be followed. Incorrect
operaon due to ignoring of instrucons may cause death, harm or damage.
•Installaon must be performed according to the installaon instrucons. Improper installaon can cause water leakage, elec-
trical shock, or re.
•Use only the included accessories and parts, and specied tools for the installaon. Using non-standard parts can cause water
leakage, electrical shock, re, and injury or property damage. Make sure that the outlet you are using is grounded and has the
appropriate voltage.
•The power cord is equipped with a three-prong grounding plug to protect against shock.
•Voltage informaon can be found on the nameplate of the unit.
•Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately
grounded or protected by a me delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maxi-
mum current of the unit. The maximum current is indicated on the nameplate located on unit), have a qualied electrician
install the proper receptacle.
•Install the unit on a at, sturdy surface. Failure to do so could result in damage or excessive noise and vibraon.
•The unit must be kept free from obstrucon to ensure proper funcon and to migate safety hazards.
•Do not modify the length of the power cord or use an extension cord to power the unit.
•Do not share a single outlet with other electrical appliances. Improper power supply can cause re or electrical shock.
•Do not install your air condioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause
electrical components to short circuit.
•Ensure there is a minimum of 36" clearance around the unit and is clear from any combusble items such as propane, re ex-
nguishers, fuel, etc.
•The exhaust hose should always be used and should never be covered or blocked which can become a re hazard.
•The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could
cause pping.
•Do not operate a unit that it has been dropped or damaged.
•Do not place the portable air condioner close to any other heat generang appliances
•Do not touch the unit with wet or damp hands or when barefoot.
•If the air condioner is knocked over during use, turn o the unit and unplug it from the main power supply immediately. Visu-
ally inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer
service for assistance.
•In a thunderstorm, the power must be cut o to avoid damage to the machine due to lightning.
•Your air condioner should be used in such a way that it is protected from moisture. e.g. condensaon, splashed water, etc.
Do not place or store your air condioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it
occurs.
•All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
•The unit's circuit board (PCB) is designed with a fuse to provide overcurrent protecon. The specicaons of the fuse are print-
ed on the circuit board, such as: T 3.15A/250V, etc.
•When the water drainage funcon is not in use, keep the upper and the lower drain plug rmly plugged into to the unit to pre-
vent choking.
CAUTION
•This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilies or
lack of experience and knowledge, unless they have been given supervision or instrucon concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
•Children must be supervised around the unit at all mes.
•If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order
to avoid a hazard.
•Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
•Do not remove any xed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
Page 4

CAUTION
•Do not remove any xed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
•Do not run cord under carpeng. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from trac area and where it will not be tripped over.
•Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Return to an authorized service facility for ex-
aminaon and/or repair.
•To reduce the risk of re or electric shock, do not use this fan with any solid-state speed control device.
•The appliance shall be installed in accordance with naonal wiring regulaons.
•Contact the manufacturer or authorized service technician for repair or maintenance informaon of this unit.
•Contact the manufacturer or authorized installer for installaon quesons of this unit.
•Do not cover or obstruct the inlet or outlet grilles.
•Do not use this product for funcons other than those described in this instrucon manual.
•Before cleaning, turn o the power and unplug the unit.
•Disconnect the power if strange sounds, smell, or smoke comes from it and contact the
•manufacturer or authorized service technician for assistance.
•Do not press the buons on the control panel with anything other than your ngers.
•Do not remove any xed covers. Contact Whynter Customer Support if this unit if it is not working properly, or if it has been
dropped or damaged.
•Do not operate or stop the unit by inserng or pulling out the power cord plug.
•Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inamma-
ble substances or vapor such as alcohol, inseccides, petrol, etc. Always transport your air condioner in a vercal posion
and stand on a stable, level surface during use.
•Always contact Whynter Customer Support for replacement parts compable with your unit. Hold the plug by the head of the
power plug when taking it out.
•Turn o the product when not in use.
WARNING
•The appliance shall be stored in a room without connuously operang ignion sources (for example: open ames, an oper-
ang gas appliance or an operang electric heater).
•Do not pierce or burn the unit.
•Be aware that the refrigerants may not contain an odor.
SAFETY COMPLIANCE
•Keep venlaon openings clear of obstrucon.
•The appliance shall be stored so as to prevent mechanical damage from occurring.
•A warning that the appliance shall be stored in a well-venlated area where the room size corresponds to the room area as
specied for operaon.
•Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid cercate from an
industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with
an industry recognized assessment specicaon.
•Servicing shall only be performed as recommended by the equipment manufacturer.
•Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of ammable refrigerants.
•Please follow the instrucons carefully to handle, install, clear, and service the air condioner to avoid any damage or hazard.
Flammable Refrigerant R32 is used within air condioner. When maintaining or disposing the air condioner, the refrigerant
(R32) shall be recovered properly and shall not discharge to air directly.
•No any open re or device which may generate spark/arcing shall be around air condioner to avoid causing ignion of the
ammable refrigerant used.
•Please follow the instrucon carefully to store or maintain the air condioner to prevent mechanical damage from occurring.
•Flammable refrigerant R32 is used in air condioner. Please follow the instrucon carefully to avoid any hazard. For specic
informaon on the type of gas and the amount, please to the relevant label on the unit itself.
Page 5

PREPARATION
All illustraons in the manual are for explanaon purpose only. Your machine may be slightly dierent. The actual shape
shall prevail. The unit can be controlled by the unit control panel alone or with the remote controller.
Control Panel
Air Outlet
Handle (both sides)
Outer Case
Wheel Casters
Air Intake (Condenser)
Air Filter
Hose-in-hose
(Air intake hose & exhaust
hose)
Upper Drain Outlet
Power Plug Socket
Power Cord Buckle
Lower Drain Outlet
DESIGN NOTICE
In order to ensure the opmal performance of our products, the design specicaons of the unit and remote control are subject
to change without prior noce.
EXHAUST HOSE INSTALLATION
The innovative hose-in-hose design delivers more than 2x faster and stronger cooling. The hoses and adapter must be installed
or removed in accordance with the usage mode. For COOL mode & HEAT mode (only for ARC-1230WNH), the adapter and
exhausts must be installed. For FAN or DRY mode, the adapter and exhaust hoses can optionally be removed.
CHOOSING THE RIGHT LOCATION
Your installaon locaon should meet the following requirements:
•Make sure that you install your unit on an even surface to minimize noise and vibraon.
•The unit must be installed near a grounded plug, and the Collecon Tray Drain (found on the back
of the unit) must be accessible.
•The unit should be located at least 25cm (9.8”) from the nearest wall to ensure proper air
condioning. The horizontal louver blade should be at least 50cm
(19.7”) away from obstacles.
•DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause
damage to the unit.
AMBIENT TEMPERATURE RANGE FOR UNIT OPERATION
MODE TEMPERATURE RANGE
Cool 62-95°F | 17-35°C
Dry 62-95°F | 17-35°C
Heat (heat pump mode) 41-86°F | 5-30°C (only for ARC-1230WNH)
Page 6

INTRODUCTION
WHAT SHOULD I LOOK FOR WHEN PURCHASING A PORTABLE AIR CONDITIONER?
The right air condioner helps you cool a room eciently. An undersized unit won't cool adequately while one that's too large will not remove
enough humidity, leaving the air feeling damp. To nd the proper air condioner, determine the square footage of the room you want to cool by
mulplying the room length by its width. You also need to know the air condioner's BTU (Brish Thermal Unit) rang, which indicates the
amount of heat it can remove from a room. Why is the cooling capacity lower on newer models than on older units? A higher number means
more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher
capacity, but are actually the same). Be sure to “size up” if your portable air condioner will be placed in a very sunny room, in a kitchen, or in a
room with high ceilings. Aer you’ve found the right cooling capacity for your room, you can look at other features.
WHY IS THE COOLING CAPACITY LOWER ON NEWER MODELS THAN OLDER MODELS?
Federal regulaons require manufacturers to calculate cooling capacity based on a specic test procedure, which was changed just this year.
Models manufactured before 2017 were tested under a dierent procedure and cooling capacity is measured dierently than in previous models.
So, while the BTUs may be lower, the actual cooling capacity of the air condioners has not changed.
WHAT IS SACC?
SACC is the representave value of Seasonally Adjusted Cooling Capacity, in Btu/h, as determined in accordance with the DOE test procedure at
tle 10 Code of Federal Regulaons (CFR) 430, subpart B, appendix CC and applicable sampling plans.
Model ARC-1030WN ARC-1230WN ARC-1230WNH
Operaonal Modes Cool / Fan / Dry Cool / Fan / Dry Cool / Fan / Dry / Heat
Cooling Capacity 12,000 BTU | SACC 10,000 BTU 14,000 BTU | SACC 12,000 BTU 14,000 BTU | SACC 12,000 BTU
Heang Capacity - - 12,000 BTU
Coverage Area 500 sq. . 600 sq. . 600 sq. .
Fan Speed Connuous | Auto | Low |Medium | High Connuous | Auto | Low |Medium | High Connuous | Auto | Low |Medium | High
Noise Level 42.5 / 49.5 / 53.5 42.5 / 49.5 / 53.5 42.5 / 49.5 / 53.5
Temperature Range 60-86°F 60-86°F Cooling: 60-86°F | Heang: 60-86°F
Timer Up to 24 hours Up to 24 hours Up to 24 hours
Refrigerant R32 R32 R32
Power Consumpon 1266W 1293W 1298W
Amps 11.8 11.9 12.0
Power Supply 115V/60Hz 115V/60Hz 115V/60Hz
Net Weight 72.8 lbs 75 lbs 77.2 lbs
Gross Weight 81.6 lbs 83.8 lbs 84.9 lbs
Unit Dimensions 19.5” W x 16.7” D x 32.5” H19.5” W x 16.7” D x 32.5” H19.5” W x 16.7” D x 32.5” H
INTRODUCTION TO INVERTER TECHNOLOGY
As pioneers in the air comfort space, we are introducing next generaon technology currently used only in high eciency ductless mini-split air
condioners. The Inverter technology will be featured in our NEX line of portable air condioners. By ulizing this much more ecient technolo-
gy, Whynter’s Inverter variable-speed system allows the compressor to opmize eciency and power consumpon together, while maintaining
a specied output.
This allows for a much quieter operaon and signicantly reduced energy con-
sumpon. The Inverter technology system potenally reduces energy usage by
more than 40% while the new hose-in-hose design delivers more than double
the cooling output. Below are the advantages of inverter technology:
•At least 40% - 50% cheaper to run as it consumes less power
•Quicker to achieve desired temperature
•Quieter operaon
•No temperature uctuaons
•No voltage peaks from compressor
HOSE-IN-HOSE COOLING SETUP
The innovave two-hose in one design and the sealed boom structure ensure no
heat leakage. This cooling setup extracts and exhausts air from the outdoor, so the
indoor space reaches an independent and balanced cool air circulaon. As a result,
the enre room can be cooled down quickly and eecvely.
Page 7

ACCESSORIES
Image Accessory Qty
Foam Seal B
(Adhesive) 2 pieces
Foam Seal C
(Non-Adhesive) 2 pieces
Security Bracket 1 set
Drain Hose 1 piece
Power Cord
Buckle 1 piece
Bolt 1 piece
Remote Control 1 set
Drain Hose
Adaptor 1 piece
WINDOW KIT INSTALLATION
Bolt
Window slider A
Screw
ABC
Window slider B
Window slider B
Bolts
Window slider A Window slider C
Image Accessory
Descripon
Qty
Hose-in-hose
(Air intake hose &
exhaust hose)
1 set
Air outlet adapter 1 piece
Exhaust Connector
Module A B C*
1 piece
each
Window Slider A 1 piece
Window Slider B 1 piece
Window Slider C 1 piece
Foam Seal A
(Adhesive) 2 pieces
Adjustable Window Slider Opon
1. Measure the window opening where the window kit will be in-
stalled.
2. Assemble as many sliders as necessary to t the window. If the
window opening is less than the minimum length of a single slider,
use the slider that has the hole in it and cut it to the correct length.
Make sure not to cut the end that has the hole as this is necessary
to aach the exhaust hose adapter.
3. Use the window slider bolts to secure the window sliders at the
correct length.
Hoses Connector Modules (For Sliding Window)
Assemble the exhaust adapter module for sliding windows using the
exhaust connector screw as shown. The window slider is eccentric so
the exhaust adapter must be installed away from the wall.
Hose-in-hose
1. Rotate the exhaust hose gently backwards.
2. Pull out the exhaust hose away from the wall.
NOTE: To ensure proper funconing, DO NOT overextend or bend the
hose. Make sure that there is no obstacle around the air outlet of the
exhaust hose (in the range of 500mm) in order for the exhaust system
to work properly. All illustraons in this manual are for explanaon
purposes only. Your air condioner may be slightly dierent. The ac-
tual shape shall prevail.
ABC
Page 8

WINDOW KIT INSTALLATION
1. Cut adhesive foam seals A and B to the correct lengths and aach them to the window frame as shown.
2. Insert the window slider kit into the window opening and close the window the secure it in place.
3. Cut the non-adhesive foam seal C to match the width or height of the window and insert it between the panes of
glass as shown to prevent outside air from entering the window.
NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following
two installaon methods.
Hung Window or Sliding Window Installaon
Page 9

WINDOW KIT INSTALLATION
Hung Window or Sliding Window Installaon
NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following
two installaon methods.
4. If desired, install the security bracket with 2 screws as shown.
5. For a hung window, aach the air outlet adapter onto the exhaust hose and rotate it 90° to secure it in place. For a
sliding window, aach the exhaust adapter onto the exhaust hose.
6. For a hung window, aach the air outlet adapter onto the window slider kit. For a sliding window, aach the
exhaust adapter onto the window slider kit.
Page 10

CONTROL PANEL
DISPLAY ICONS
Wireless feature (Wi-Fi enabled models only)
Illuminates to show wireless connection is activated.
Operation Mode Indicator Lights
Illuminates to show current mode operation.
LED Display
Shows the set temperature in °F or °C and the Auto-timer settings. While on FAN modes, it shows the room temperature.
Fan Speed Indicator Lights
Illuminates to show the set fan speed.
Sleep Indicator Light
Illuminates when Sleep Mode is activated.
Filter Indicator Light
The LED will illuminate after 250 hours of operation. This feature is a reminder to clean the Air Filter for more efficient operation.
CONTROL BUTTONS
Swing / Wireless Mode
Auto-swing
Press to start the auto swing feature. When the operation is ON, press the SWING button to stop the louver at a desired angle.
Turn on Wireless connection mode
To turn on Wireless connection mode on, press and hold the swing button for 3 seconds and the LED display will show “AP” for 3
seconds. Follow the instructions on the Wi-Fi setup manual and the latest app version available for your phone operating system.
Turn off Wireless connection mode
Once the wireless connection mode is successful, press and hold the swing and down buttons for 3 seconds and the LED display
will show “OF” for 3 seconds.
Connection Successful
If the connection is successful within 8 minutes, the unit will exit wireless connection mode automatically and the wireless
indicator will illuminate.
Connection Failed
If the connection has failed within 8 minutes, the unit will exit Wireless connection mode automatically.
NOTE: When you restart the wireless functions, it will take a period of time to connect to the network automatically. Always be
sure your wireless connection is working properly and there is a valid internet connection for Wi-Fi functionality to work.
Timer
Press to program timer delayed switch ON or OFF function.
Modes
Press to change modes. Controls the functions modes: AUTO, COOL, DRY, FAN, and HEAT*.
*only for ARC-1230WNH
Page 11

CONTROL PANEL
CONTROL BUTTONS
Up and Down buttons
Adjusts set temperature 1°F | 1°C increments or timer hours (0 - 24 hours).
NOTE: This unit is capable of displaying set temperature in Fahrenheit or Celsius. To convert from one to another, press and hold
the Up and Down buttons for 3 seconds.
Fan
Press to change fan speed. Controls the 5 fan speeds and mode: Continuous, Auto, Low, Medium, and High.
NOTE: In Auto and Dry mode, the fan speed control is disabled Continuous Fan Mode. Press and hold to select continuous fan
speed. The fan speed will keep on operating in a continuous speed based on the last fan speed setting.
Sleep Mode
Press to activate Sleep mode. Press SLEEP button again to stop the sleep operation.
NOTE: This feature is not available in FAN or DRY mode.
Filter
Press SLEEP button for 3 seconds to initiate the filter feature.
Power
Press to turn the air conditioner on and off.
ERROR CODES
E1 - Room temperature sensor error
Unplug unit and restart in 5 minutes
E2 - Evaporator sensor error
Unplug unit and restart in 5 minutes
E3 - Condenser sensor error
Unplug unit and restart in 5 minutes
E4 - Display panel sensor error
Unplug unit and restart in 5 minutes
P1 - Water reservoir full
Drain water from the unit
Page 12

OPERATION INSTRUCTIONS
BEFORE USING YOUR APPLIANCE
•Remove the exterior and interior packing
•Before connecng the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possi-
bility of a malfuncon in the cooling system from handling during transportaon
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF button on the remote
control
COOLING MODE
In this mode, the air condioner cools and dehumidies the room. To acvate this funcon mode, press the MODE
buon unl the COOL indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3
minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust
out the hot air. The temperature seng range of this air condioner is from 60°F / 16°C to 86°F / 30°C. To set the temperature,
press the + or - buons. This air condioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambi-
ent temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air condioner.
To set the fan speed, press the FAN buon. In cooling mode, the dierence in noise level between the fan speeds is not very no-
ceable when the compressor is on. Try seng the unit to Fan only mode, you should be able to hear the dierence between high
and low fan speed sengs.
DRY (DEHUMIDIFYING) ONLY MODE
In this mode, the air condioner only dehumidies the room, the compressor will acvate intermiently depending on the ambient
temperature and the fan speed is set to LOW. To acvate this funcon mode, press the MODE buon unl the DRY indicator light
is displayed. Please note that when switching funcon mode, there will be an approximately 3 minute transion me. In dehumidi-
fying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumid ies.
To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be re-circulated into the
room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan
speed is set at Low.
NOTE: When using dehumidifying mode, venng the exhaust hose to the outside is not required. If vented, the warm air is exhaust-
ed to the outside and cooling within the room may occur. Addionally, if the exhaust hose is not vented, the unit may require more
frequent draining. Also, the air condioner does not have a humidistat in which a specic humidity level can be set.
AUTOMATIC MODE
When you set the air condioner in AUTO mode, it will automacally select cooling or fan only operaon depending on what
temperature you have selected and the room temperature is close to the unit. The fan speed is automacally selected and cannot
be changed .To operate the unit in Auto mode when the unit is on, press the MODE button until the AUTO indicator light comes on.
HEAT MODE (*only for ARC-1230WNH)
This air condioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor
unit. In this mode, the air condioner heats the room. To acvate this funcon mode, press the MODE buon unl the HEAT indi-
cator display comes on. When the heang mode is set, the compressor will start in approximately 3-5 minutes. The heang tem-
perature seng range of this air condioner is from 60°F - 86°F / 16°C - 30°C . To set the temperature, press the UP and DOWN
buons. To set the fan speed, press the FAN buon.
FAN ONLY MODE
In this mode, only the fan of the air condioner runs and circulates the air in the room. To acvate this funcon mode, press the
MODE buon unl the FAN indicator light comes on. In this funcon mode, the temperature cannot be set. Subsequently, set the
desired fan speed by pressing the FAN buon. When using FAN only mode, venng the exhaust hose to the outside is oponal.
Page 13

OPERATION INSTRUCTIONS
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This funcon mode enables a delayed switch ON or delayed switch OFF of the air condioner. The me (hours) delay can be set,
enabled and disabled.
SETTING SWITCH OFF TIMER
With the air condioner operang in any funcon mode, press the TIMER buon. The TIMER OFF light will come on. Then set the
desired me delay OFF hours by pressing the UP and DOWN buons. The me increments are at 0.5 hour to up to 10 hours, fol-
lowed by 1 hour increment up to 24 hours. When the delay me set has elapsed, the air condioner switches o. To cancel the
delayed switch o funcon, turn o the air condioner or adjust the me set-ng to 0.0.
SETTING DELAYED SWITCH ON TIMER
With the air condioner is o, press the TIMER buon. The TIMER ON light will come on. Then set the desired me delay ON hours
by pressing the UP and DOW N buons. The me increments are at 0.5 hour to up to 10 hours, fol-lowed by 1 hour increment up
to 24 hours. When the delay me set has elapsed, the air condioner switches on. To cancel the delayed switch on funcon, turn
on the air condioner or adjust the me seng to 0.0.
I SENSE FUNCTION
The remote control serves as a remote thermostat allowing for the precise and comfortable temperature control. With this tech-
nology, an ecient temperature sensor is integrated in the remote control. To acvate the I SENSE funcon, press I SENSE buon
on the remote control. Once this funcon is acvated, the remote control will send the temperature signal to the air condioner
every 3 minutes interval unl you press the I SENSE buon again. The air condioner will automacally cancel the I SENSE feature
if it does not receive the signal during any 7 minutes interval.
NOTE: The I SENSE feature is not available in DRY and FAN mode. Shiing the operang mode or turning o the unit will cancel the
Follow Me feature automacally. The remote control needs to be within 26 feet reach of the indoor unit for the I SENSE mode to
work appropriately.
SLEEP MODE
In this mode, the air condioner gradually increases the set temperature in cooling mode, decreases the noise level and conserves
energy. In Economy and cooling mode, the set temperature is increased by 1°C/ 2°F in the rst 30 minutes. The temperature will
then increase by another 1°C/ 2°F aer an addional 30 minutes. This new temperature will remain the same for 7 hours. To ac-
vate this funcon mode, press the SLEEP buon unl the SLEEP indicator light comes on.
NOTE: This feature is not available in FAN or DRY mode.
AUTO RESTART
In the event of a power outage, the air condioner restarts at the previously set funcon mode and sengs when power is re-
stored.
CONTROLLING THE AIR FLOW DIRECTION
The louvers can be controlled to Auto-Swing or in a xed direcon. To control the air ow direcon by Auto-Swing, press the
SWING buon. To set the louvers in a xed angle or direcon, press SWING buon while on Auto-Swing mode when desired angle
is chosen.
NOISE LEVEL
Portable air condioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reecng o
hard surfaces such as a oor or wall can make the sounds seem louder than they actually are.
•The compressor may make a pulsang or high-pitched sound
•Water running from the evaporator to the water tank may make a splashing sound
•Refrigerant owing may make a gurgling sound
•Fan sound may come from front and back air vents
COMPRESSOR LOCK OUT
This portable air condioner is opmized to operate in an ambient temperature of 64°F – 90°F. The compressor circuit has an auto-
mac 3 minute me delayed start if the unit is turned o and on quickly. This prevents over-heang of the compressor and possi-
ble circuit breaker tripping.
Page 14

The portable air condioner can be switched on by the remote control. To transmit signals from the remote control to the air
condioner, point the front part of the remote handset towards the control panel on the air condioner. Recepon of the signal
is conrmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.
NOTE:
•Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences
•Electronic and uorescent lamps may interfere with the signal transmissions between the remote control and the air condi-
oner
•Remove the baeries if the remote control is not used for long periods
1Mode indicator Displays the current selected mode (Auto, Cool, Dry, Heat* or Fan)
2Wireless indicator Displays when the remote is turned on, and disappears when it is turned o
3Timer On indicator Displays when TIMER ON is set
4Timer O indicator Displays when TIMER OFF is set
5Swing indicator Displays auto-swing feature is turned, and disappears when it is turned o
6Temperature/Timer display (h) Displays the set temperature or timer setting when using ON/ OFF functions
"h (hours)" indicator is shown when timer settings are activated
7Remote Control indicator Displays when the remote is turned on and disappears when it is turned o
8Temperature Scale indicator Displays temperature scale Fahrenheit or Celsius
9Lock sengs indicator Indicated all the current sengs are locked
10 Sleep Feature indicator Displays when SLEEP funcon is acvated
11 I Sense Feature indicator Displays when I SENSE funcon is acvated
12 Fan Speed indicator Displays the current selected fan speed
13 Up buon Increases set temperature/me
14 Down buon Decreases set temperature/me
15 Mode buon Controls the function modes: Auto, Cool, Dry, Heat* and Fan
*only for ARC-1230WNH
16 Power buon Turns the unit On and O
17 Fan Speed buon Controls the fan speeds: Auto, High, Medium, or Low
(Connuous mode cannot be set using the remote control)
18 Swing Feature buon Press to stop or start louver auto-swing feature
19 Sleep Feature buon Starts or stops louver movement and set louver angle
20 Timer ON buon Enables the Timer On
21 I Sense Feature buon Press to iniate I SENSE feature
22 Lock sengs buon Press I SENSE and TIMER OFF buons to lock current sengs
23 Timer OFF buon Enables the Timer O
24 LED Display buon Press this buon to turn on and turn o the display on the indoor unit
25 Temperature Scale buon Press to change Temperature Scale (Fahrenheit | Celsius)
REMOTE CONTROL
Page 15

REPLACING THE REMOTE BATTERIES
This remote control comes with two AAA baeries. Place the baeries in the re-
mote control before use.
Slide the back cover from the remote downward to expose the baery com-
partment.
Insert the baeries, ensure to match the (+) and (-) symbols on the ends of
the baeries with the symbols inside the baery compartment.
Slide the baery cover back into place.
Notes:
•The air condioner will not respond if curtains, doors or other materials block
the signal from the remote control to the unit.
•Prevent any liquid from contact with the remote control. Do not expose the
remote control to direct sunlight or heat.
•If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air condioner may not funcon properly. Use
curtains to prevent the sunlight from falling on the receiver.
•Do not mix old and new baeries or baeries of dierent types.
•Do not leave the baeries in the remote control if it is not going to be used for more than two months.
REMOTE CONTROL
CARE AND MAINTENANCE
SAFETY PRECAUTIONS
•Always unplug the unit before cleaning or servicing.
•DO NOT use ammable liquids or chemicals to clean the unit.
•DO NOT wash the unit under running water. Doing so causes electrical danger.
•DO NOT operate the portable air condioner if the power supply was damaged during cleaning. A damaged power cord must
be replaced with a new cord. Contact Whynter Customer Support for more informaon.
WATER DRAINAGE
When the internal drain pan becomes full the appliance will beep 8 mes and the digital display will show error code P1. The air
condioning or dehumidifying acon will stop but the fan may connue to operate. Ensure that the appliance is turned o and
unplugged and that it is close to a oor drain before seng up any drain opon.
A. Drain Plug
Remove the drain plug and allow the water to completely
drain. Replace the boom drain plug, pressing rmly to ensure
a ght t and no leaks.
B. Connuous Drain
During dry mode, install connuous drain opon so that the
appliance will automacally drain collected water. Remove the
upper drain plug and aach the drain hose that was provided
with the appliance. Place the open end of the drain hose over
the receptacle that the appliance will drain into; this could be a
basement oor drain, a sink or similar. Ensure that there are no
kinks or bends in the drain hose and that it goes straight down
toward the oor. The connuous drain is acvated by gravity
only. If the hose is not posioned directly downwards, water
will not drain correctly.
Page 16

UNIT CLEANING
CLEANING
•Unplug the appliance before cleaning or servicing.
•Clean the cabinet with a lukewarm damp cloth and neutral
detergent. Dry the cabinet with a lint-free dry cloth.
•Do not use gasoline, paint thinner or other chemicals to
clean the appliance.
•Do not wash the appliance directly under a tap or using a
hose. It may cause electrical damage.
AIR FILTERS
The air lter should be cleaned every two weeks to ensure e-
cient performance. In households with animals, the air lters
may need to be cleaned more oen and the external grills may
need to be wiped to prevent blocked air ow.
To access the lter:
LONG-TERM STORAGE
Drain all water from the appliance.
Run the appliance on Fan mode for half a day in a warm room to dry the inside of the appliance and prevent mold formaon.
Turn o the appliance and unplug it, wrap the cord and bundle it with tape.
Remove the baeries from the remote control.
Clean the air lters and reinstall them.
Store the appliance in a cool, dark place. Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of
the appliance.
DISPOSAL
This appliance should not be treated as regular household waste. Check for local regulatory compliance regarding the approved
and safe disposal of this appliance.
ERROR CODES
P1 - water tray is full - aach drain hose and drain excess water
If any other error code appears on the display, unplug the air condioner and allow it to sit undisturbed for 5 minutes. If the error
code persists when the unit is plugged back in, please contact Whynter Customer Support.
CARE AND MAINTENANCE
Page 17
1. Switch off the air conditioner.
2. Hold the exhaust hose, push it backward slightly and then
lift it up.
3. Remove the filter from the unit.
4. Use a vacuum cleaner or tap lightly to remove loose dust
and dirt.
5. Rinse the filter thoroughly under warm running water (no
hotter than 100° F.)
6. Dry thoroughly before re-inserting the filter.

TROUBLESHOOTING
Many common portable air condioner problems are easily resolved. Try the troubleshoong suggesons below to see if
the problems can be resolved before having to contact the service department.
PROBLEM POSSIBLE CAUSES SOLUTIONS
The portable air condioner does not
turn on
•Power failure / outage
•The automac switch, line fuse, or
breaker has been tripped
•The power supply voltage is too low
•The power cord is damaged
•The L.C.D.I. power plug for the unit is
tripped
•The internal water reservoir is full and
‘P1” appears on display
•Restore the power supply
•Flip the switch / change the fuse /
turn the breaker back on. Also note
that you may have too many applianc-
es drawing power on one circuit, you
may need to move the other applianc-
es to another circuit
•Move the unit onto another circuit
with the correct voltage
•Call for service. Only authorized per-
sonnel should replace damaged power
cord or power plug
•Press the Reset buon on the L.C.D.I.
power plug
•Drain water from the air condioner
•Possible loose internal connecon.
•Please contact Whynter for service.
The unit turns on but the compressor
does not turn on (the fan runs but the
unit is not cooling)
•The room temperature is outside of
the operaonal tolerances of the unit
•The Cooling mode is not on
•The compressor has not turned on yet
because of its me delay
•The set temperature is too high
•The internal water reservoir is full and
‘P1” appears on display
•This unit is designed to work in ambi-
ent temperatures of 63°F to 90°F.
•Press the MODE buon unl the
COOL light is shown on the display.
•Give the compressor 3 minutes to
turn on aer the Cooling mode has
been selected.
•Set the air condioner to a lower tem-
perature.
•It is recommended to set the temper-
ature to at least 5°F of the ambient
temperature.
•Either manually drain the water by
removing the drain plug or allow the
unit to exhaust the water itself by run-
ning the fan only mode. Then cooling
will resume.
•Possible loose internal connecon.
•Please contact Whynter for service.
The air coming out of the unit is
not very cold, or the airow
volume is weak
•The lters are dirty or obstructed
•The air intake or exhaust is obstructed
•The unit is set in DRY or FAN mode
•The unit is set to low fan speed
•Clean the air lters
•Make sure there is at least 20" of
clearance from the air intake. Make
the length of the exhaust hose is as
short as possible
•Set the unit to the cooling mode
•Set the unit to a higher fan speed
Page 18

TROUBLESHOOTING
Many common portable air condioner problems are easily resolved. Try the troubleshoong suggesons below to see if
the problems can be resolved before having to contact the service department.
PROBLEM POSSIBLE CAUSES SOLUTIONS
The unit has worked for a long me, but
the room is not cold enough
• Windows or doors are open
• There are too many people in the
room
• There is direct sunshine into the room
• The room is a kitchen or with many
heat producing appliances
• There is a server in the room
• The room is too large
• Close all windows and doors
• You may need addional cooling or
another air condioner.
• Close curtains or blinds and try to
minimize the amount of direct sun-
light into the room.
• You may need addional cooling or
another air condioner.
The unit is very noisy • The unit is not level
• The surface underneath the unit is
uneven
• Low power voltage
• Make sure the unit is on hard, level
and stable surface.
• Move the unit to a locaon with a
level and hard oor.
• Make sure the wall outlet and support
the required power consumpon of
the air condioner and do not use an
extension cord.
The unit leaks water • The unit is lted or not leveled
• The water tank is full
• Make use the unit is leveled
• Drain water from the drain plug at the
back of the air condioner
Fan speed cannot be changed • Fan speed dierences are not very
noceable
• The fan speed dierence is not very
noceable when the compressor is on.
Try seng the unit to Fan only mode,
you should be able to hear the dier-
ence between high and low fan speed
sengs.
Page 19

ONE YEAR LIMITED PARTS WARRANTY
THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER product is warranted to the original owner, purchased from an authorized Whynter dealer within
the 48 U.S. connental states, for one year from the original purchase date against defects in material and work-
manship under normal residenal usage. Should your WHYNTER product prove defecve within one year from
the date of purchase, contact Whynter’s Customer Support team with the serial number and proof of purchase
to make a warranty claim. A Return Authorizaon number must be issued before returning any parts or prod-
ucts. Parts or products received without a Whynter issued Return Authorizaon number will be refused. Under
this warranty, Whynter will repair or replace any parts found defecve with new or remanufactured parts or ex-
change the defecve product with a new, refurbished, or remanufactured product at our discreon. All defecve
products and parts covered by this warranty will be repaired or replaced on a mail-in basis to Whynter’s Service
Center. This warranty is not transferable. Aer the expiraon of the warranty, the cost of labor and parts will be
the responsibility of the original owner.
Aer two months to one year, the customer will be responsible for the return freight cost to Whynter’s Service
Center. Please package the product carefully in its original packaging to avoid damage in transit. Whynter is not
responsible for damage resulng from shipper mishandling or improper packaging. Please retain the original box
and packaging materials.
THIS WARRANTY DOES NOT COVER:
•Acts of God, such as re, ood, hurricanes, earthquakes and tornadoes.
•Improper power supply such as power surge, low voltage, defecve household wiring or inadequate fuses.
•Use in commercial or industrial applicaons.
•Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a de-
fect in material or workmanship.
•Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and spe-
cial handling provisions in the instrucons.
•Damage to the nish of the case, or other appearance parts caused by wear.
•Damage caused by repairs or alteraons to the product by anyone other than authorized by the manufactur-
er.
•Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.
•Products sold AS IS or from an unauthorized reseller.
•Products that have had their serial numbers removed or defaced.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED
HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR-
POSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE
LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY
BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLU-
SION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO
THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
To obtain service or informaon, contact
Whynter LLC via email at support@whynter.com or call
866-WHYNTER.
Product contents and specicaons may change without noce.
Copyright © 2021
WWW.WHYNTER.COM
Other manuals for ARC-1030WN
1
This manual suits for next models
2
Table of contents
Popular Inverter manuals by other brands

Carbest
Carbest 825030 User instruction

Rishabh
Rishabh RADIUS AP V-S-50 k-AE -TL Installation & operation manual

SWH
SWH Solar Racking installation guide

Lenze
Lenze Teachware i7000 manual

YASKAWA
YASKAWA VS mini C Series instruction manual

Generac Power Systems
Generac Power Systems Quitesource QT036 Specifications