6
Reset to the factory settings
The device can be reset to the original factory settings using one of the following methods:
Method 1: Remove the device from the Z-Wave network
Method 2: Six consecutive clicks on button (B)
Method 3: Set parameter 61 to value 0 - FACTORY RESET (see paragraph 0).
INFO: If the reset is performed while the device is still part of a network, it notifies the other devices that
it has been removed (Device Reset Locally Notification).If WiDom Universal Relay Switch receives a
removal notification from another device, it will delete the removed device from its own associations.
Including the device into an existing Z-Wave network
WiDom Universal Relay Switch can be included and operated in any Z-Wave network with other Z-Wave
certified devices from any other manufacturers. As constantly powered node WiDom Universal Relay Switch
will act as repeater regardless of the vendor in order to increase reliability of the network.
The device supports both the Network Wide Inclusion mechanism (which offers the ability to be included in a
network even if the device is not in the direct range of the controller) and Normal Inclusion.
By default, if the device is not included in any network, as soon as it is powered the Network Wide Inclusion
procedure starts and lasts for about 1 minute. The procedure can be reactivated at the next device restart or
by pressing the (R) button.
If the used controller does not support the Network Wide Inclusion functionality, the device may be included in
the network through Normal Inclusion by pressing the (B) button once or three times or alternatively by pressing
the external switch once.
INFO: During the inclusion procedure activated by a single click on the external switch, the system also
automatically determines the switch type (See parameter No. 62).
Excluding the device from a Z-Wave network
Only a controller can remove a device from the network. WiDom Universal Relay Switch is compatible with all
Z-Wave certified controllers. After the exclusion function has been activated from the controller, the device can
be removed, putting it in Learning Mode by pressing the (B) button once or three times or more conveniently
by using the external switch after having enabled the learning mode activation from external switch (see
parameter N°65).
Request network update
If there is a SUC (Static Update Controller) or SIS (SUC ID Server) in the network, a network update can be
requested by pressing the external switch four times.
Associations
WiDom Universal Relay Switch can control other devices like other relays or dimmers. WiDom Universal Relay
Switch supports 5 association groups:
Group 1: devices that will be notified of changes in its status
Group 2: devices that will be controlled by a single click on the external switch
Group 3: devices that will be controlled by a double click on the external switch
Group 4: devices that will be controlled by a triple click on the external switch
Group 5: devices that will be controlled by hold on the external switch
TIP: WiDom Universal Relay Switch can control up to 16 devices for each group. To avoid network
delays, we recommend limiting the amount of associated devices to no more than 5 per group.