WilTec 51487 User manual

Operation Manual
51487
Read and follow the operating instructions and safet information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ
insignificantl .
Updating the documentation
If ou have suggestions for improvement or have found an irregularities please contact us.
© by WilTec Wildanger Technik GmbH Seite 5
http //www.WilTec.de
http //www.aoyue.eu
http //www.teichtip.de

The information contained in this document is subject to change without prior notice. No part of this
document can be copied or duplicated in another form without the prior written consent of WilTec
Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liabilit for an errors in
this user manual or the connection diagram.
Although WilTec Wildanger Technik GmbH has made ever effort to make sure that this user manual is
complete, accurate and updated, errors cannot alwa s be avoided. In the event of problems with this
user manual please complete and send this form back to us.
FAX-notification (+++49 2403 55592-15),
from ________________________________________
Name ________________
Firm _____________________
Tel/Fax __________________
I would like to report the following mistakes
_______________________________ ____________________________________
Customer Service WilTec Wildanger Technik GmbH
e-mail: service@WilTec.info
Tel:++ +49 2403 55592-0
Introduction
Thank ou for purchasing this qualit product. To minimize the risk of injury by means of fire or
electric shock we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you have understood its
content.
Always use a grounded power connection with the appropriate mains voltage. You can
nd the corresponding mains voltage on the type plate. If you have any doubts about the
connection being grounded, have it checked by a qualied professional. ever use a
faulty electric cable.
Do not inspect the electrical part of the pressure pond lter in a wet or damp environment
or when you are wet yourself and protect it from direct sunlight. Install this device in a
safe location so that nobody can step on the cable, fall over or damage it. Disconnect the
power plug before cleaning it and use only a damp cloth for cleaning. Avoid using
cleaning agents and make sure that no liquid enters the electrical part of the pump.
The electric part of the device contains no parts that can be inspected or serviced b the user. Leave
the maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised
intervention the 2- ear warrant is no longer valid! Keep these operation instructions safe.
© by WilTec Wildanger Technik GmbH Seite 6
http //www.WilTec.de
http //www.aoyue.eu
http //www.teichtip.de

This new digital flowmeter is suitable for filling stations as well as industrial and private use. The instal-
lation of the flowmeter is eas and without much effort. Cleaning and maintenance is possible without
much effort. The meter is intended for use in different countries. It is adjustable in four different units,
such as Liters (L) / Gallons (GAL) / Pints (PT) / Quarts (QT). The power suppl is ensured b two inter-
nal batteries (AAA).
Technical specifications
Connection BSPT / NPT 1“
Maximum pressure 0,25 MPa
Accurac ± 0,5%
Flow rate 38 – 380 l/min
Allowed media diesel, kerosene, gasoline
Temperature range -10~+60℃
Batter 2 x AAA
Stand-B Time Batter Ca. 2 ears
LCD displa Displa 6 digits
How it works
Reset counter to "0"
To reset the displa to 0, press and hold the "DISPLAY" button for one second.
Total Display
When ou press the "CALIBRATE" button, the total displa is displa ed. If this screen has reached a
total of 999,999, it is automaticall reset to 0.
Calibrate settings
Press and hold the "CALIBRATE" button for 3 seconds. Press "DISPLAY" or "CALIBRATE" for the de-
sired setting.
The displa is programmed so that the digital flowmeter returns to standb mode after 5 seconds of in-
activit .
Setting the unit
Press and hold the "CALIBRATE" button for 3 seconds. Now press the "DISPLAY" button five times,
and then press the "CALIBRATE" button to select from the various units.
Liters (L) / Gallons (GAL) / Pints (PT) / Quarts (QT)
Maintenance
The measuring instrument is almost maintenance-free. However, it is important that the rotor is free to
move. Keep the meter clean and free of impurities. If the rotor does not rotate freel , appl a penetra-
ting lubricant to the rotor, shaft and bearings. Remove an foreign objects or deposits from the rotor
with a soft brush or small sonde. Ensure that the turbine rotor or the turbines are not damaged.
Replace the batteries when "L Bat" is displa ed.
To ensure accurate readings, make sure that there is no air in the s stem and the minimum flow rate is
ensured.
© by WilTec Wildanger Technik GmbH Seite 7
http //www.WilTec.de
http //www.aoyue.eu
http //www.teichtip.de

Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2002/96/EC) were
implemented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out
wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the
domestic waste.
The compan WilTec Technik GmbH has been registrated in the German registr EAR under the
WEEE-registration number DE45283704.
Disposal of used electrical and electronic appliances
(intended for use in the countries of the European
Union and other European countries with a separate
collection s stem for these appliances).
The logo on the article or on its packaging points out
that this article must not be treated as normal
household waste but must be disposed to a rec cling
collection point for electronic and electrical waste
equipment. B contributing to the correct disposal of
this article ou protect the environment and the health
of our fellow men. Environment and health are
threatened b inappropriate disposal.
Materials’ rec cling helps reduce the consumption of raw materials.
Additional information on rec cling this article can be provided b our local communit , municipal
waste disposal facilities or the store where ou purchased the article.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and an commercial use, even in part of this instructions
manual require the written permission of WilTec Wildanger Technik GmbH.
© by WilTec Wildanger Technik GmbH Seite 8
http //www.WilTec.de
http //www.aoyue.eu
http //www.teichtip.de
Table of contents
Other WilTec Measuring Instrument manuals