WilTec 51713 User manual

© by WilTec Wildanger Technik GmbH Seite 7
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Operation Manual
Oil changer
ARTIKEL 51713
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities please contact us.

© by WilTec Wildanger Technik GmbH Seite 8
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
The information contained in this document is subject to change without prior notice.
No part of this document can be copied or duplicated in another form without the prior
written consent of WilTec Wildanger Technik GmbH. The WilTec Wildanger Technik
GmbH assumes no liability for any errors in this user manual or the connection dia-
gram.
Although WilTec Wildanger Technik GmbH has made every effort to make sure that
this user manual is complete, accurate and updated, errors cannot always be avoided.
In the event of problems with this user manual please complete and send this form
back to us.
FAX-notification (+++49 2403 55592-15),
from: ________________________________________
Name: ________________
Firm:_____________________
Tel/Fax:__________________
I would like to report the following mistakes:
___________________________________________________________________
Customer Service WilTec Wildanger Technik GmbH
e-mail: service@WilTec.info
Tel:++ +49 2403 55592-0

© by WilTec Wildanger Technik GmbH Seite 9
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury by
means of fire or electric shock we urge that our clients take some basic safety
precautions when using this device. Please read the operation instructions care-
fully and make sure you have understood its content.
Always use a grounded power connection with the appropriate mains voltage. You can find the
corresponding mains voltage on the type plate. If you have any doubts about the connection
being grounded, have it checked by a qualified professional. Never use a faulty electric cable.
The electric part of the device contains no parts that can be inspected or serviced by
the user. Leave the maintenance, adjustment and repair to qualified technical person-
nel. In case of unauthorised intervention the 2-year warranty is no longer valid! Keep
these operation instructions safe.
TECHNIQUE DATA:
Operating pressure 8-10 bars.
Degree of vacuum 0-0.8bar negative
Tank capacity 24L
Waste liquid engine oil and gear oil
Diameter of Extration probes:
Nr Abmessungen Material Anzahl Durchluss
1 Φ6×4×720 PVC 2 0.6L/min
2 Φ6×4×900 PVC 1 0.6L/min
3 Φ8×6×720 PVC 2 1.6L/min
Nr Messure Material Number Flow Rate
1 Φ6×4×720 PVC 2 0.6L/min
2 Φ6×4×900 PVC 1 0.6L/min
3 Φ8×6×720 PVC 2 1.6L/min
Package contents:
Please inspect and look for damages from shipping when package is first received. If
the unit is damaged in any way, please contact customer service and include pictures
if possible.
In the package, you will find:
a) One 3024 oil extractor.
b) Probes 5 pieces.
c) Operation Instruction
Time for the depression at 8-10 bar is 2-3 min.
Air-consumption is 200 lt /min.

© by WilTec Wildanger Technik GmbH Seite 10
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
1. TANK DEPRESSION
a. Close all cock, beside cock〝3〞.
b. Connect compressed air (8-12 bars) position〝A〞.
c. Open gradually cock〝9〞up to the max. depression (0.58-0.60 cm/Hg)
d. Close cock〝9〞and disconnect air-compressed-hose.
2. OIL SUCTION
-Connect the correct probe and use the oil-changer, opening the cock 〝8〞
3) TANK EMPTYING
-Connect air compressor with position” 5”, then open value “12” gradually for mak-
ing tank pressure reaching 1 bar.
-If necessary, turn off value “12” after achieving 1 bar pressure
-Put ejection pipe into the oil drum, then turn on the value”6”.
-Turn off value “6” after emptying of underside oil tank .
5. SAFTY DEVICE
A safety valve will release pressure when pressure is over 30PSI during ejection.
6. TROUBLE SHOOTING
A:Vacuum meter don’t work
a) Check the air pressure: standard air pressure through “inlet valve "should be
115PSI; Air consumption is 200L/Min.
b) Make sure all the valves are on the correct place.
c) Check vacuum operator-to-tank seal.
B:There is a figure showed on the vacuum meter but the machine don’t aspirate
a) Check extraction hose-to-probe seal.
b) Temperature of waste oil is too low.
c) Make sure that extraction pipe open.
d) Make sure that extraction pipe do not block off and probe don’t touch the bot-
tom of tank.
7. ORDINARY MAINTENANCE
d) Check leakage of the machine regularly.
a) Pipe to pipe connection should be close together.
b) It’s necessary to release the waste oil as soon as possible in case of the
corroding of tank.
8、NOTES
a) Application for oil change with probe: for plastic probe big suction capacity
0.42Gallon/min, small one 0.16 Gallon/min.
b) If you work for suction oil for a long time, please check the adapter ofthe probe
for leakage.
c) For TOYOTA and CAMEY automobile there’s a problem with the probe oper-
ation. You’d better unscrew drain bolt to release instead of using probe.
d) Names of Parts:
N.B.: It is not allowed to fill the tank over the max level,
which is indicated on the pipe on the side of the b
arrel.

© by WilTec Wildanger Technik GmbH Seite 11
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
1. Extraction Probes 2. Silencer 3. Cock(3/4”)
4. Ejection Connector 5.Air inlet valve(Ejection) 6. Cock(1/2”)
7. Extraction connector 8. Cock(1/4”) 9.Cock(1/4”)
10. Vacuum Gauge 11. Safety valve 12. Cock(1/4”)
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part of
this instructions manual require the written permission of WilTec Wildanger Technik
GmbH.
7
8
12
6
4
3
1
2
5
9
10
11
A