Wintex Agro WINTEX 1000 User manual

P A G E | 1
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
1. DESCRIPTION OF WINTEX CONTROL SYSTEM FOR THE WINTEX 1000
1 2 3 4 5 678
910 11 12 13 14 15 16
1: Extra rotation / no rotation 9: Operation mode
2: Up / plus 10: Not in use
3: Preset depth 11: Down / minus
4: Escape 12: Menu / ENTER
5: Reset 13: Not in use
6: Not in use 14: Enable manual functions
7: Probe up / down 15: Rotation + STOP
8: Not in use 16: START + HOME

P A G E | 2
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
2. CONNECTION AND STARTUP
Connect all plugs and cables of the control system according to the mounting manual.
At the first startup of the Wintex 1000 after mounting the control system, take place on the driver’s seat. Press “MANUAL” key and flip the
“PROBE” switch downwards until the probe reaches the ground.
Go to the test menu by pressing the “MENU” key. The screen will now show “Setup Menu”. Press the arrow down key, and the “Test Menu” will
appear. You can now read the current depth (e. g. 52 cm) of the soil sampler. You need to remember this value for the next step.
Press the arrow down and the “MENU” key simultaneously until the display shows “code”. Use the arrow keys to select “17” and press “MENU”.
You have now entered the “Setup Menu”. Scroll down to “Offset”and select the current depth from the previous step (e. g. 52 cm).
The soil sampler is now ready to use.

P A G E | 3
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
3. START SCREEN
Under normal use the display will show the current depth at the top line. The next line shows the operation mode of the soil sampler / what the soil
sampler is currently doing - “probe up”, “probe down”, “rotation” or “ready” when the sampling process has ended.
There is a counter at the bottom on the right which counts the number of sticks in each sample. The counter can be reset to 0 by pressing
“RESET”. You can get access to this function from the start screen, and then press the arrow down key.
You can also see the total amount of sticks taken. This value cannot be reset.
4. SETTINGS: DEPTH ADJUSTMENT, NUMBER OF SAMPLES
In the “Setup Menu” you can preset and adjust a number of settings.
Press “MENU”. The display will now show “Setup Menu”
Press “MENU” to adjust the depth and / or the number of sticks for each sample.
You can shift between settings by using the arrow up and arrow down keys.
The settings can be adjusted by holding the “MENU” key down until the number of the display flashes. Then adjust the figure by using the
arrow up or the arrow down keys. When you have entered the preferred number, press “MENU” (enter) again, and the setting is saved.

P A G E | 4
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
Adjusting the depth
Go to the “Setup Menu”. Scroll down until the “Depth” appears on the display. Adjust the depth by using the arrow up and down keys.
Once the correct depth is set, press “MENU”. The setting is now saved and will appear on the start screen.
Number of samples
Go to the “Setup Menu”. Scroll down until the “Samples per box” appears on the display. “Samples per box” is the number of sticks you
need for each sample. Determine the number of sticks for each sample by using the arrow keys (arrow up for rising the numbers, arrow
down for lowering the numbers).
When the soil sampler has taken the entered number of sticks, it will not take another sample before you press “RESET”for a few seconds.
By entering the number 99, you can disable this function, and the soil sampler will sample indefinitely.
5. ROTATION
Rotation stop
To make sure that the probe stops at the correct angle every time, you need to adjust the “Rotation stop height”. This is the point where
the soil sampler gets the signal to stop rotation to make sure that the probe is in the right position before it reaches the soil box. This setting
will differ according to the soil sampler, the hydraulics and the soil conditions.
Go to the “Setup Menu”. Scroll down to “Rotation stop height” and adjust the number with the arrow keys.

P A G E | 5
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
Rotation mode
The standard setting of the soil sampler is that the probe goes down, rotates once and then goes up again. If you press the key with the
rotation symbol, the LED of the key will light up. The probe will now carry out an extra rotation before going up. If you hold the key with the
rotation symbol down for five seconds, the LED will blink slowly, and the probe will not carry out an extra rotation.
6. MANUAL USE OF THE SOIL SAMPLER
If you press the “MANUAL” key with the green letters, you can access all functions in green letters at the flip switches (“probe up”, “probe
down” and” rotation”) manually.

P A G E | 6
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
7. TAKE THE SAMPLE
When all values are set, stay clear of the soil sampler and flip the “START / HOME” switch towards “START”. The soil sampler will now take a
complete soil sample.
Stop the soil sampler
If the soil sampler should fail to go down to the determined depth, or if you should encounter a problem during sampling, you can either activate
the emergency stop, or you can flip any of the switches on the control unit to stop the soil sampler. When flipping the “START / HOME” switch to
“HOME”, the soil sampler will return into the start position.
8. TEST MENU
By entering the test menu, you can see the current
-power supply
-depth of the probe,
and you can also monitor and see the control system’s
-keys
-flip switches
-LEDs
Enter the test menu by pressing the “MENU” key. The screen will now show “Set up Menu”. Press the arrow down key, and the “Test Menu” will
appear.
Press ”MENU” again, and you will now have access to the above-mentioned content.

P A G E | 7
Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
Current power supply, pressure and depth Monitor keys
Monitor switches Monitor LEDs
The next lines show the inputs and outputs. In the event of an issue, your local dealer might need this information to trouble shoot.
Other manuals for WINTEX 1000
2
Table of contents
Popular Control System manuals by other brands

Comm Box
Comm Box Joey Micro Programming & installation manual

Carbide 3D
Carbide 3D Shapeoko PRO Assembly guide

sugar-valley
sugar-valley Vistapool installation guide

A/DA
A/DA Platinum Elite installation manual

FRONIUS
FRONIUS Power Control Box operating instructions

SITGroup
SITGroup Proflame instruction manual

WatchDog
WatchDog 3452H product manual

Landi Renzo
Landi Renzo LAMBDA CONTROL SYSTEM/2 Installation and adjustment manual

Delta
Delta DE212-2S GLOBAL DSD Operation and installation manual

Samson
Samson Trovis 6400 Mounting and operating instructions

ABB
ABB LVS Digital FC610 user manual

KAR-TECH
KAR-TECH CAN RANGER III installation manual