manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wisi
  6. •
  7. Receiver
  8. •
  9. Wisi VALUE LINE LR 26 R User manual

Wisi VALUE LINE LR 26 R User manual

Other Wisi Receiver manuals

Wisi MULTISYSTEM DY 64 1810 User manual

Wisi

Wisi MULTISYSTEM DY 64 1810 User manual

Wisi Micro Node User manual

Wisi

Wisi Micro Node User manual

Popular Receiver manuals by other brands

Televes ZAS HD SAT user manual

Televes

Televes ZAS HD SAT user manual

Realistic DX-75 Operating and service instructions

Realistic

Realistic DX-75 Operating and service instructions

Saris 4620 Assembly instructions

Saris

Saris 4620 Assembly instructions

Mini DTR 206C PVR user manual

Mini

Mini DTR 206C PVR user manual

RF Elements TwistPort manual

RF Elements

RF Elements TwistPort manual

Denon DN-200WS user guide

Denon

Denon DN-200WS user guide

Yamaha RX-V467 owner's manual

Yamaha

Yamaha RX-V467 owner's manual

Russound SaphIR 858 instruction manual

Russound

Russound SaphIR 858 instruction manual

Quasonix RDMS Firmware update procedure

Quasonix

Quasonix RDMS Firmware update procedure

Pioneer XV-HTD1 Service manual

Pioneer

Pioneer XV-HTD1 Service manual

ATZ HDMI-V2-44HE150 manual

ATZ

ATZ HDMI-V2-44HE150 manual

Sony XNV-770BT MyTomTom Specifications

Sony

Sony XNV-770BT MyTomTom Specifications

Grundig STR 7122 TWIN Service manual

Grundig

Grundig STR 7122 TWIN Service manual

Creative Blaster Modem user guide

Creative

Creative Blaster Modem user guide

Panduit ATLONA AT-OME-RX11 installation guide

Panduit

Panduit ATLONA AT-OME-RX11 installation guide

VOLTCRAFT UTPS-40 operating instructions

VOLTCRAFT

VOLTCRAFT UTPS-40 operating instructions

JVC KW-ADV794 instructions

JVC

JVC KW-ADV794 instructions

Litelink VT-1001 operating instructions

Litelink

Litelink VT-1001 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Betriebsanleitung
Operating instructions
LR 26 R Optischer Receiver ortsgespeist
Optical Receiver local feed
411 xxx a
EN 50 083-1ff
Servicearbeiten dürfen nur vom Fachpersonal durchgeführt werden.
Netzspannungsführende Teile beachten! Spannungsfrei schalten
Services and repairs should only be carried out by experts.
Pay attention to live parts or wires! Switch off power supply.
Redundant opical receiver
Automatic level control (opt, ALC) for constant
output level
All functions controlled via microprocessor
All settings via handset OK 41 / 41 A or web
interface
SNMP remote interface
Redundanter optischer Empfänger
Automatische Pegelregelung (opt, ALC) für
konstanten Ausgangspegel
Microprozessor gesteuerte Funktionen
Alle Einstellungen mittels Handset OK 41 / 41 A
oder Web-Interface
SNMP-Remote-Interface
WISI VALUE LINE
Parametereinstellungen mit Handset / Parameter settings with handset
Anschluß
Deckel abschrauben.
Handset an Buchse “RJ-45” einstecken.
Betriebsspannung anschließen.
Parameter-Menü
▲▼ Tasten — Parameter wählen.
►Taste — Weiter zum Parameter-Untermenü.
◄Taste — Zurück.
Parameter-Untermenü
◄► Tasten — Anzeige oder zu ändernden Wert wählen.
Cursor blinkt unter dem Wert z.B. 89
▲▼ Tasten — Wert ändern.
Speichern: Nach dem Beenden aller Einstellungen, die Taste
◄mehrmals drücken, bis die Anzeige: “saving data to EEPROM”
erscheint. Danach sind alle Werte gespeichert.
Left Right
Down
Up
W I S I L R 2 6
1 . 00V 0
R
Connection
Unscrew the cover.
Plug the handset into socket “RJ-45”.
Connect the supply voltage.
Parameter menu
▲▼ keys — Select parameter.
►key — Open parameter sub-menu.
◄key — Back.
Parameter sub-menu
◄► keys — Select display or value to be changed.
Cursor blinks under the value, e.g. 89
▲▼ keys — Change the value.
Saving: after completion of all settings, press the key ◄
several times until “Saving data to EEPROM” is displayed. All
settings are now saved.

 



























 

 
 
   



 



  
20.10.10 Maurer

WISI communications GmbH & Co. KG
Empfangs und erteiltechnik
Postfach 1220
D 522 Niefernschelbronn
G\HWENTWICKLNG\1_HWEntwicklungNeu\1_WISIArtikel\1_Artikel A bis Z\LR\
LR26\LR26R\1_Entwicklungsordner\LR26R_BSB.vsd




power
amp
Testpoint
20 dB

fuse
C
equalizer
0 – 15 dB
attenuator
0  15 dB
AGC
Handset
interface
amp

LED
RX 1
amp
pigtailed PIN
amp
pigtailed PIN AGC
LED
RX 2
RLevel
detector
redundancy
switch
RJ45, WEB
Interface/
Monitoring
Technische Daten / Specifications
Downstream
Wellenlänge / Wavelength 1290 - 1600 nm
Optische Rückflußdämpfung / Optical return loss > 40 dB
Faser / Fiber single mode 9 / 125 µm
Optischer Anschluß / Optical connector SC / APC
Ausgangs-Rückflußdämpfung / Output return loss > 18 dB (-1,5 dB / oct.)
Übertragungsbandbreite / Transmission bandwidth 47 - 1006 MHz
Optischer Eingangspegel für geregelten Ausgangspegel -7...+3 dBm
Optical input level for controlled electrical output level
Geregelter Ausgangspegel (ALC=on, OMI=5%) 112 dBµV
Controlled output level
Dämpfungssteller / Attenuator adjustable 0-15 dB
-Einstellschritte / Adjustment steps 0.5 dB
Entzerrer einstellbar / Equalizer adjustable 0-15 dB
-Einstellschritte / Adjustment steps 0.5 dB
xxx / Amplitude response (O-E) < ± 1 dB
Empfindlichkeit / Sensitivity < 5.5 pA / √Hz
Summenstörabstände (42 ch, CENELEC, flat, Poptin < 0 dBm) 111 dBµV
Distorsion products for
-CTB, CSO > 60 dB
Summenstörabstände (42 ch, CENELEC, 9 dB slope, Poptin < 0 dBm ) 114 dBµV
Distorsion products for
-CTB, CSO > 60 dB
HF-Testpunkt am Ausgang / RF test point at output - 20 dB
Handset-Einstellungen / Handset functions
Konfiguration Dämpfung / Attenuation 0-15 dB
Configuration Entzerrer / Equalizer 0-15 dB
ALC-Regelung / ALC control on / manual
ALC offset -3...+3 dB
Redundanz-Modus / Redundancy mode auto / manual
Redundanz Schaltposition / Redundancy switch position rec.1 / rec.2
Überwachung Optischer Pegel Eingang 1 und 2 / Optical level input 1 and 2, HF-Pegel / RF level,
Monitoring Versorgungsspannung / Supply voltage, Temperatur / temperature,
Dämpfungssteller / Attenuator settings, Entzerrer / Equalizer settings
Allgemeines / General
Betriebsspannung / Operating voltage 180-265 V AC
Leistungsaufnahme / Power consumption < 20 W
Anschlüsse / Connectors PG11
Schutzklasse / Protection class IP 24
Abmessungen / Dimensions 232 x 145 x 86 mm
Max. Luftfeuchte, nicht kondensierend / Max. humidity non condensing 95 %
Betriebstemperatur / Operating temperature -20°C...+55°C
Lagertemperatur / Storage temperature -25°C...+75°C
EMV / EMC EN 50083-2
04/11
WISI Communications GmbH & Co. KG
Empfangs- und Verteiltechnik
Wilhelm-Sihn-Straße 5-7, 75223 Niefern-Öschelbronn, GERMANY
Tel . 07233 / 66-292, Fax. 66-320, http://www.wisi.de
excellence in digital ...
Technische Änderungen und Druckfehler vorbehalten!
Technical Modifications reserved. WISI cannot be held
liable for any printing error.