manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wisi
  6. •
  7. Receiver
  8. •
  9. Wisi VALUE LINE LR 26 R User manual

Wisi VALUE LINE LR 26 R User manual

Other Wisi Receiver manuals

Wisi Micro Node User manual

Wisi

Wisi Micro Node User manual

Wisi MULTISYSTEM DY 64 1810 User manual

Wisi

Wisi MULTISYSTEM DY 64 1810 User manual

Popular Receiver manuals by other brands

Greenheck 06 null

Greenheck

Greenheck 06 null

Garmin GA 23 Owner's manual and reference guide

Garmin

Garmin GA 23 Owner's manual and reference guide

Aiphone PS-12F instructions

Aiphone

Aiphone PS-12F instructions

IMES TCS-01CA-PMI Original Operating Instruction

IMES

IMES TCS-01CA-PMI Original Operating Instruction

BWI Eagle AIR-EAGLE SR Product information bulletin

BWI Eagle

BWI Eagle AIR-EAGLE SR Product information bulletin

AMIMON AMN12310 WHDI datasheet

AMIMON

AMIMON AMN12310 WHDI datasheet

Dual DMCPA79BT Installation & owner's manual

Dual

Dual DMCPA79BT Installation & owner's manual

Sound Associates SA652P Operation manual

Sound Associates

Sound Associates SA652P Operation manual

Sherwood NewCastle R-772 Service manual

Sherwood

Sherwood NewCastle R-772 Service manual

Audio A10-RX Series user guide

Audio

Audio A10-RX Series user guide

AllSee PushShare PSRV1.1 user manual

AllSee

AllSee PushShare PSRV1.1 user manual

DEMAG DRC-DR D2 operating instructions

DEMAG

DEMAG DRC-DR D2 operating instructions

Teleco TVRCL868A02 manual

Teleco

Teleco TVRCL868A02 manual

Bosch RF3222E installation instructions

Bosch

Bosch RF3222E installation instructions

Kramer 631R user manual

Kramer

Kramer 631R user manual

Xpress xmc10 installation guide

Xpress

Xpress xmc10 installation guide

JVC KD-MR1BTS instruction manual

JVC

JVC KD-MR1BTS instruction manual

Omega Engineering UWTC-REC3 user guide

Omega Engineering

Omega Engineering UWTC-REC3 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Betriebsanleitung
Operating instructions
LR 26 R Optischer Receiver ortsgespeist
Optical Receiver local feed
411 xxx a
EN 50 083-1ff
Servicearbeiten dürfen nur vom Fachpersonal durchgeführt werden.
Netzspannungsführende Teile beachten! Spannungsfrei schalten
Services and repairs should only be carried out by experts.
Pay attention to live parts or wires! Switch off power supply.
Redundant opical receiver
Automatic level control (opt, ALC) for constant
output level
All functions controlled via microprocessor
All settings via handset OK 41 / 41 A or web
interface
SNMP remote interface
Redundanter optischer Empfänger
Automatische Pegelregelung (opt, ALC) für
konstanten Ausgangspegel
Microprozessor gesteuerte Funktionen
Alle Einstellungen mittels Handset OK 41 / 41 A
oder Web-Interface
SNMP-Remote-Interface
WISI VALUE LINE
Parametereinstellungen mit Handset / Parameter settings with handset
Anschluß
Deckel abschrauben.
Handset an Buchse “RJ-45” einstecken.
Betriebsspannung anschließen.
Parameter-Menü
▲▼ Tasten — Parameter wählen.
►Taste — Weiter zum Parameter-Untermenü.
◄Taste — Zurück.
Parameter-Untermenü
◄► Tasten — Anzeige oder zu ändernden Wert wählen.
Cursor blinkt unter dem Wert z.B. 89
▲▼ Tasten — Wert ändern.
Speichern: Nach dem Beenden aller Einstellungen, die Taste
◄mehrmals drücken, bis die Anzeige: “saving data to EEPROM”
erscheint. Danach sind alle Werte gespeichert.
Left Right
Down
Up
W I S I L R 2 6
1 . 00V 0
R
Connection
Unscrew the cover.
Plug the handset into socket “RJ-45”.
Connect the supply voltage.
Parameter menu
▲▼ keys — Select parameter.
►key — Open parameter sub-menu.
◄key — Back.
Parameter sub-menu
◄► keys — Select display or value to be changed.
Cursor blinks under the value, e.g. 89
▲▼ keys — Change the value.
Saving: after completion of all settings, press the key ◄
several times until “Saving data to EEPROM” is displayed. All
settings are now saved.

 



























 

 
 
   



 



  
20.10.10 Maurer

WISI communications GmbH & Co. KG
Empfangs und erteiltechnik
Postfach 1220
D 522 Niefernschelbronn
G\HWENTWICKLNG\1_HWEntwicklungNeu\1_WISIArtikel\1_Artikel A bis Z\LR\
LR26\LR26R\1_Entwicklungsordner\LR26R_BSB.vsd




power
amp
Testpoint
20 dB

fuse
C
equalizer
0 – 15 dB
attenuator
0  15 dB
AGC
Handset
interface
amp

LED
RX 1
amp
pigtailed PIN
amp
pigtailed PIN AGC
LED
RX 2
RLevel
detector
redundancy
switch
RJ45, WEB
Interface/
Monitoring
Technische Daten / Specifications
Downstream
Wellenlänge / Wavelength 1290 - 1600 nm
Optische Rückflußdämpfung / Optical return loss > 40 dB
Faser / Fiber single mode 9 / 125 µm
Optischer Anschluß / Optical connector SC / APC
Ausgangs-Rückflußdämpfung / Output return loss > 18 dB (-1,5 dB / oct.)
Übertragungsbandbreite / Transmission bandwidth 47 - 1006 MHz
Optischer Eingangspegel für geregelten Ausgangspegel -7...+3 dBm
Optical input level for controlled electrical output level
Geregelter Ausgangspegel (ALC=on, OMI=5%) 112 dBµV
Controlled output level
Dämpfungssteller / Attenuator adjustable 0-15 dB
-Einstellschritte / Adjustment steps 0.5 dB
Entzerrer einstellbar / Equalizer adjustable 0-15 dB
-Einstellschritte / Adjustment steps 0.5 dB
xxx / Amplitude response (O-E) < ± 1 dB
Empfindlichkeit / Sensitivity < 5.5 pA / √Hz
Summenstörabstände (42 ch, CENELEC, flat, Poptin < 0 dBm) 111 dBµV
Distorsion products for
-CTB, CSO > 60 dB
Summenstörabstände (42 ch, CENELEC, 9 dB slope, Poptin < 0 dBm ) 114 dBµV
Distorsion products for
-CTB, CSO > 60 dB
HF-Testpunkt am Ausgang / RF test point at output - 20 dB
Handset-Einstellungen / Handset functions
Konfiguration Dämpfung / Attenuation 0-15 dB
Configuration Entzerrer / Equalizer 0-15 dB
ALC-Regelung / ALC control on / manual
ALC offset -3...+3 dB
Redundanz-Modus / Redundancy mode auto / manual
Redundanz Schaltposition / Redundancy switch position rec.1 / rec.2
Überwachung Optischer Pegel Eingang 1 und 2 / Optical level input 1 and 2, HF-Pegel / RF level,
Monitoring Versorgungsspannung / Supply voltage, Temperatur / temperature,
Dämpfungssteller / Attenuator settings, Entzerrer / Equalizer settings
Allgemeines / General
Betriebsspannung / Operating voltage 180-265 V AC
Leistungsaufnahme / Power consumption < 20 W
Anschlüsse / Connectors PG11
Schutzklasse / Protection class IP 24
Abmessungen / Dimensions 232 x 145 x 86 mm
Max. Luftfeuchte, nicht kondensierend / Max. humidity non condensing 95 %
Betriebstemperatur / Operating temperature -20°C...+55°C
Lagertemperatur / Storage temperature -25°C...+75°C
EMV / EMC EN 50083-2
04/11
WISI Communications GmbH & Co. KG
Empfangs- und Verteiltechnik
Wilhelm-Sihn-Straße 5-7, 75223 Niefern-Öschelbronn, GERMANY
Tel . 07233 / 66-292, Fax. 66-320, http://www.wisi.de
excellence in digital ...
Technische Änderungen und Druckfehler vorbehalten!
Technical Modifications reserved. WISI cannot be held
liable for any printing error.