1. Product introduction:
Thank you for purchasing metal standalone access controller/card reader, This
product adopts is a touching, induction card to open the door of the entrance guard
al-in-one, there are many features as follow:
Support four option: ID style, IC style, Non-waterproof style, waterproof style optional.
All-metal case design(Zinc alloy). Organic glass panel (Acrylic touch screen).
8000 user capacity for storing and reading to provide a powerful security, the high-grade
Built-inmicroprocessor with strong anti-interference ability, high safety and areliability.
Data copy and backup to the same series if access control.
Circumscribed humanized tamper alarm function.
Can be used as card reader or standalone access controller.
Extend wiggins dummy: WG2/34 input and output.
Can set up management cards (Deleted card and added card…)
Active and passive lock signal output.
Imported double point relay output signal port.
Suooprt three opening way: password, credit card, card+password.
Extending function: external memory, tamper alarm, extended voice ect.
2. Function characteristics:
"0"
Modify programming code and set master card
"1"
Add card type user
"2"
Add password type user
"3"
Add password & card type user
"4"
Delete single user
"5"
Delete all user
"6"
Modify users password
"7"
Modify delayed open door
"8"
System initialization
"9"
Set general opening password, add and delete card
"*"
Press"
*", enter "123456" or swipe systematic Master card directly
Get to programming mode

3. Technical parameters
NO
Specification
Parameter
1 Reading distance 5-10cm
2 Working temperature -20
℃
-70
℃
3 Working humidity 0-95%
4 Static electricity ≤50mA
5 Working voltage DC 12 V
6 Static current 50mA
4. Function setting method
4.1 the facorty default settings
The initial opening password 7890, programming code 123456.
4.2 quick operation settings
(1), Swipe the main card, enter the programming system state
(2), Swipe added card, enter the add user state
(3), Swipe deleted card, enter the delete user state
4.3 modify the programming code and set up the master card
A, press * Programming code # 0 The new password #
The new password #
Note: A beeping said succedd (password length for 1-8 code).
B,Press * Programming code # 0 Swipe card
Note: A beepiing said setting the main card successfully.
4.4 Add card type users
press * Programming code # 1 Four user id # Read the card
Note: The four user id is random, user id automatically add 1 when continue read card.
4.5 add password type users
press * Programming code # 2 Four user id The user password #
Note: Four user id ( For example: 1 enter 0001), the user password length for 0-4.
A beeping said add user password type user operation is successful. You can add
password type continuously with continue to input the user code.
(when opening the door, please input programming code and user password end with # )
4.6 add card+password type users
press * Programming code # 3 Four user id Four user password #

Swipe card
Note: A beeping said add card+passwrod user operation is successful, you can add
Card + password type user continuously with ti input the user id.
(opeing the door process: First swipt card, Second a green light flashing,Third input user
password ends with # )
4.7 delete a single users
press * Programming code # 4 Enter the user id or credit card #
press * Programming code # 4 credit card #
press * Programming code # 4 Enter the 10 user card number #
Note: it can be operated continuously in the condition of programming.
4.8 delete all users
press * Programming code # 5 Input programming password or main card #
Note:A beeping said delete all user operation is successful.
4.9 modify the user password
press * Programming code # 6 Four user code Four new password #
Note: It can be operated continuously in the condition of programming.
4.10 modify the door delay time
press * Programming code # 7 Enter delay time #
Note: The delay time is 0-255 seconds. The default is 3 secoonds.
4.11 system initialization
press * Programming code # 8 Enter programming code or swipe master card
#
Note: A beeping said initial success, that clear all settings.
4.12 set management card ( increased card & deleted card )
press * Programming code # 9 Swipe card
A, the first one is to set increased card, the second is to set deleted card.
B, this feature is convenient to increase & delete user’s card.
C, press * to active increased card adding users or deleted card removing users.
4.13 set up the general password to open the door
press * Programming code # 7 Enter 4 password #
( The initial opening password is 7890, enter 0000 to cancel it. )

4.14 exit programming
Press * to exit programming, automatically quit after 10s no operated instruction.
4.15 tamper alarm closed and opened
A, Cancel the alarm enter password to cancel the alarm temproarily.
B, Close the Tamper alarm function swipe deleted card 3 times
C, Open the Tamper alarm function swipe added card 3 times
5. Jumper Setting of access controller
5.1. J1 of active and passive output signal settings:
When 1 & 2 connected, COM NC NO used as the switch quantity output signal,
When 2 & 3 connected,shorting sircuit COM & GND as the active output signal.
5.2. J2 Reset Setting:
Short circuit J2, then power on the controller can initialized the programming code.
(Note:RESET Setting won’t wipe data )
6. Data copy
1. TXD connect RXD , RXD connect TXD to the same type access control.
2. Press copy code * 13825256 # to the main access controller which with date.
3. The green light flashing on both of the access controller.
4. A beeping sound on the main access coontroller, it means successful operation .
7. Transformation between Access controller and card reader
7.1. Access control model( Initial setting is access control model) :
2. GLED connect to GND , 2nd power on the machine.
3. The green light flasing ( don’t waiting until it alarm), disconnected GLED & GND .
4. A alarm sound means the machine convert to access controller.
7.2. Card reader model (WG26 output):
1. D0 connect to GND , 2 power on the machine.
2. The green light flasing ( don’t waiting until it alarm), disconnected D0 & GND .
3. A alarm sound means the machine convert to WG26 card reader.
7.3. Card reader model ( WG34 output):
1. D1 connect to GND , 2 power on the machine.

2. The green light flasing ( don’t waiting until it alarm), disconnected D1 & GND .
3. A alarm sound means the machine convert to WG34 card reader.
8. Wiring diagram
8.1. Common power supply diagram
Figure 1
Note: Please change the operating mode when use access control machine as
access control rader, TXD and RXD is Data copying interface, two hosts can be
copied each other, when access wiring should set two TXD and RXD reverse
operation.
8.2 Special Power connecting program

Figure 2
Note: Please change the operating mode when use access control machine as
access control rader, TXD and RXD is Data copying interface, two hosts can be
copied each other, when access wiring should set two TXD and RXD reverse
operation.
9. Wiring diagram
Red +12V 12V+DC regulated power input
Black GND 12V-DC regulated power input
Yellow NO Relay normally open end ( connect positive electric lock)
Grey COM Relay publick end, connect GND
Purple NC Relay closed end ( connect positive electric lock)
Brown BTN Exit button one end ( the other end connected GND)
Black GND 12V-DC Regulated power input
Green D0 WG D0
White D1 WG D1
Blue LED Reader mode
Orange TXD Data copying interface
Pink RXD Data copying interface

10. Warm prompt
*Please do not to repair the machine, if any problem, please returm to factory
*Before installation on the wall, if you want to punch, please check wiring, and line pipe
Carefully for unnecessary trouble, etc. when drilling or fixing clamp please use safety
Glasses.
*It is without prior notice if instruction is likely to be different for product upgrades.
Table of contents