1www.ltech.cn
50/60Hz
≤0.18A/115Vac ≤0.08A/230Vac
84%300mA 8 %500mA@ (at full load), 2 @ (at full load)
ta:-20~50°Ctc:90°C
-40~80°C/10~95%RH
±0.03%/°C(0-50°C)
PF>0.95/115Vac , PF>0.9C/230Vac(at full load) (at full load)
THD≤10%/230Vac(at full load)
C (Test twidth=130us tested under 50% Ipeak)/230Vacoldstart15A
L-N:2KV
Max.0.24mA
SE-12-100-500-W1D
≤48V
100-500mA
9-42Vdc
0.9W~12W
±5%
≤3600Hz
DALIDT6
115Vac/230Vac
100-240Vac
120-300Vdc
ErP
IEEE1789
CIESVM
DF
85g±10g
110×35×20mm(L×W×H)
Intelligent Tunable White LED Driver (Constant Current)
Housing made from SAMSUNG/COVESTRO's V0 flame retardant PC
materials.
Ultra small, thin and lightweight, screwless end cap.
Set the output current down to 1mA.
DALI bus standard IEC62386-101, 102, 207.
Class 2 LED driver, Safety Extra Low Voltage (SELV).
Soft-on and fade-in dimming function enhances your visual comfort.
T-PWM™ dimming technology allows quality and high-end lighting.
The whole dimming process is flicker-free with high frequency
exemption level.
Comply with the EU’s ErP Directive, networked standby<0.5W.
When there is no load, the output will be 0V to prevent damage to LEDs
due to poor contact.
Overheat, over voltage, overload, short circuit protection and
automatic recovery.
Suitable for ClassⅠ/Ⅱ/Ⅲindoor light fixtures.
Normal service life can reach 100,000 hours.
5-year warranty (Rubycon capacitor).
Set the DALI group, scene in the advanced DALI template.
Multiple current levels, wide voltage range, suitable for LEDs with
different power
Change the dimming interface, output current, DALI address and
other parameters on the NFC programmer or via the App, and sync
the parameters to the driver.
The certification icon represents undergoing certification applications only, and final certification qualification subject to actual product.
Overheat
Protection
Short circuit
protection
Over Load
protection
V
Over voltage
protection
Multi current
setting
Constant power
setting
DIM / CT
Technical Specs
Model
Dimming Interface
Output Feature
Output Type
Protection Grade
Insulation Grade
Isolation
Constant current
IP20
Class II (Suitable for class I/ II /III light fixtures)
Features
Dimming Range
Maximum output voltage(No-load)
Output Current Range
Output Voltage
Output Power Range
Current Accuracy
PWM Frequency
OUTPUT
LF Current Ripple
0~100%, down to 0.01%
<3%(Maximum current for non dimming state)
INPUT
Frequency
Input Current
Efficiency (Typ.)
Power Factor
THD
Inrush Current
Anti Surge
Leakage Current
Input Voltage
DC Voltage Range
AC Voltage Range
ENVIRONMENT
Working Temperature
Working Humidity 20~95%RH,non-condensing
Storage Temperature/Humidity
Temperature Coefficient
Vibration 10~500Hz, 2G 12min/1cycle, 72 min for X, Y and Z axes respectively
PROTECTION Overvoltage Protection
Overload Protection
Short Circuit Protection
Overheat Protection Intelligently adjust or turn off the current output if the PCB temperature ≥110°C. When the PCB temperature <90°C, automatically recover normal output
Automatically protect the device when voltage exceeds the no-load voltage. It can be recovered automatically
Automatically protect the device when the load exceeds 102% of the rated power. Automatically recover once load is reduced
Enter hiccup mode if short circuit occurs, and recover automatically
I/P-O/P: 100MΩ/500VDC/25°C/70%RH
Insulation Resistance
Withstand Voltage I/P-O/P: 3750Vac
SAFETY
&
EMC
SafetyStandards
EMC Emission
EMC Immunity
China
European Union
Korea
Russia
Germany
CB Member States
Australia
Europe
India
Britain
Canada
GB19510.1, GB19510.14
EN61347-1, EN61347-2-13, EN62384
KC61347-1, KC61347-2-13
IEC61347-1, IEC61347-2-13
EN61347-1, EN61347-2-13, EN62493
IEC61347-1, IEC61347-2-13
CCC
CE
KC
EAC
TUV
CB
RCM AS61347-1, AS61347-2-13
ENEC EN61347-1, EN61347-2-13, EN62384
UKCA BS EN 61347-1, BS EN 61347-2-13, BS EN 62493
BIS IS 15885 (PART 2/SEC 13)
CUL CSA C22.2 NO.250.13
UL UL 8750
America
EN61000-4-2,3,4,5,6,8,11, EN61547
CCC
CE
KC
EAC
GB/T17743, GB17625.1
EN55015, EN61000-3-2, EN61000-3-3, EN61547
KSC 9815, KSC 9547
IEC62493, IEC61547, EH55015
RCM EN55015, EN61000-3-2, EN61000-3-3, EN61547
CUL ICES-005
UKCA BS EN IEC 55015, BS EN IEC 61000-3-2, BS EN 61000-3-3, BS EN 61547
UL FCC PART 15B
China
European Union
Korea
Russia
Australia
Britain
Canada
America
Power Consumption
Flicker/Stroboscopic Effect
Standby power consumption
Networked standby <0.5W (After shutdown by command)
No-load power consumption <0.5W (When the lamp is not connected)
No standby mode
Meet IEEE 1789 standard/High frequency exemption level
Pst LM≤1.0,SVM≤0.4
Phase factor DF0.9
OTHERS Dimensions
Weight(N.W.)
DALI DT6
SE-12-100-500-W1D