Wizard ON-S5700-48GP-4TF User manual

Model : ON-S5700-48GP-4TF
48 * Gigabit Port + 4 * 10G SFP Port +
1 * Console Port + 1 * Mini-usb Console port +
1 * USB 2.0 (300W) Layer 3 Managed PoE switch
Introduction to the installation manual
The Product User's Manual mainly introduces the software and hardware parameters,
installation methods, and precautions during the installation process of ON-S5700-
48GP-4TF switch.
This manual includes the following sections:
Chapter 1: Product introduction. Briefly describe the basic functions and features of the
switch, detailed hardware and software specifications, and appearance information.
Chapter 2: Hardware Connections. Guide the connection and precautions between the
switch and other devices.
Chapter 3: Product Installation. Guide the hardware installation method and precautions
of the switch.
Chapter 4: Product Packaging and Use Recommendations

Chapter 1 Product Introduction
1.1 Product Introduction
ON-S5700-48GP-4TF layer 3 management switches are designed for small and
medium enterprises (SMEs), large enterprises and Internet service providers
(ISPs).They have high performance, flexibility, fault tolerance and advanced software
capabilities to maximize commercial value.
ON-S5700-48GP-4TF switch features 48
gigabit Ethernet RJ45 ports and 10 Gb SFP + ports, advanced security features and
advanced quality of service (QoS), can be used as a core, distributed or access layer
switch, has high port density, switch stack and manageability, and is an ideal choice for
a variety of commercial network applications.
1. 2 Product Features
Full Gigabit Ethernet port
48 full Gigabit RJ45 POE network ports, and 4 10 Gigabit SFP fiber ports, breaking the
traditional 100 megabit limit, data transmission is not stuck
Broadcom high-end chip, performance is more stable and powerful
Broadcom high-end chip can greatly improve network data processing rate
Support DHCP
Support DHCP server, DHCP relay, DHCP Snooping
Support Apollo cloud platform one-stop management
Support cloud platform to visualize management of switches and PDs connected to the
PD, making operation and maintenance management easier

1.3 Product Software and Hardware Specifications
Chip Broadcom high performance chipset
Flash 16MB
Memory 256MB DDR
48 x 10/100/1000Mbps RJ45 POE ports
4x 10GSFP+ Fiber ports
Ports
1Console ports,1 Mini USB console port, 1 USB 2.0
Mode:Storage/ forwarding
Total Bandwidth:176Gbps
Transmission Rate:131Mpps
Performance
Mac address: 16K
Surge proof ±6KV
ESD Contact:±6KV Non-contact:±8KV
Power in 100-240V/50-60Hz (300W)
Dimension
(L×W×H)
440mm×365mm×44mm
Software Features
Support hardware watchdog, restore factory Settings, system and
port LED
Support global information, statistics, log information
Support user management, alarm management, configuration
management
Support port rate, duplex, flow control, maximum frame length
configuration
Basical
Functions
Support port mirroring, port speed limit, port energy saving
Apollo Cloud one Support three management methods: local management, cloud

management, mobile management
stop
management
prevention in advance; Real-time map, fast fault location; Cloud
operation, maintenance, configuration, upgrade batch
processing; Multi-user, multi-dimensional authority, hierarchical
control; AI blessing, intelligent scheduling; Business analysis and
decision making; Open interface, customer business import;
Support for automatic identification, management and acquisition
of information about the downlink device
IEEE 802.3: Ethernet media access control (MAC) protocol
IEEE 802.3i:10BASE-T Ethernet
IEEE 802.3u:100BASE-TX Fast Ethernet
IEEE 802.3ab:1000BASE-T Gigabit Ethernet
IEEE 802.3z:1000BASE-X Gigabit Ethernet(Fiber)
IEEE 802.3ad: Standard method for performing link aggregation
IEEE 802.3x: traffic control
IEEE 802.1p: LAN layer 2 Qos/Cos protocol on traffic priority
(multicast filtering function)
IEEE 802.1q:VLAN Bridge operation
IEEE 802.1d:STP spanning tree
IEEE 802.1s:MSTP Multiple spanning tree
IEEE 802.1w:RSTP Fast spanning tree
IEEE 802.1x: Access control and authentication
Protocol
standard
G.8032:ERPS Ethernet loop protection switch
Support Layer 3 interface
Support IPv4、IPv6 Address configuration
Layer 3 interface
Support ARP configuration

Support ND configuration
Supports RIP V1/V2, OSPFv1\OSPFv2 dynamic routing
Router Support static routing
Support DHCP server
Support DHCP relay
DHCP
Support DHCP Snooping
Support 4K numbers of VLAN
Support 802.1Q VLAN、MAC VLAN ,IP VLAN
VLAN
Voice VLAN
According IEEE 802.1dstandard
Support MAC address automatic learning and aging
MAC address list
Support static, dynamic, filtering address table
Password protection
Support user access based on port number, IP address, and
MAC address
Support HTTPS、SSL V3、TLS V1、SSH V1/V2
Support IP-MAC-PORT ternary binding
Support ARP protection, IP source protection, DoS protection
Support DHCP Snooping and DHCP attack protection
Support 802.1X authentication, AAA
Support port security, port isolation
Security
Support CPU protection
Support POE power limitation
Support POE chips status view
Support setting POE port priority
POE
Support setting POE supply period

Support AI POE
Support L2(Layer 2)~L4(Layer 4) Packet filtering
(ACL) Support port mirroring, port redirection, flow rate limiting, QoS re-
marking
Support 8 ports queues
Support port priority, 802.1P priority, DSCP priority
Support SP, WRR, WFQ priority scheduling algorithm
(QoS)
Supports automatic identification, management, and retrieval of
information about attached devices
Support STP(IEEE 802.1d),RSTP(IEEE 802.1w)and
MSTP(IEEE 802.1s) protocol
Spanning tree
Support loop protection, root bridge protection, TC protection,
BPDU protection, BPDU filtering
Support IGMP v1/v2 Snooping
Support fast leave
Support multicast VLAN
Multicast
Supports multicast filtering, packet statistics, and unknown
multicast discards.
Support multicast resist
Support broadcast resist
Storm resist
Support for unknown unicast resist
Support static link aggregation
Support dynamic link aggregation
Support IP, MAC, hybrid load balancing mode
Link aggregation
Max support 32 link aggregation groups
Support IPv6 Ping、IPv6 Tracert、IPv6 Telnet
IPv6 Support IPv6 SSH 、IPv6 SSL

Support web management(HTTP、HTTPS、SSL V3)
Support CLI(Telnet、SSH V1/V2、local ports )
Support SNMP V1/V2/V3
Support LLDP、RMON
Support ARP protection、IP source protection 、DoS protection
Support CPU monitor、Memory monitor
Support Apollo one stop management
Support system log, grading warning
Management
and maintenance
Support Ping, Tracert detection, cable detection
1.4 Product appearance
Front panel
Contains indicator light, RJ45 port as shown below
Indicator light
The working information of ON-S5700-48GP-4TF indicator is as shown in the following
table.
Indicator light Indicato
r light
instructi
on
normal status Abnormal and trouble shooting
PWR Indicator
light
Power
Indicato
r light
Yellow light
lighting
If the light does not illuminate, check
if the power supply of the external
power outlet is normal, and the
power adapter is connected correctly.

Link Indicator
light
Connec
tion
Indicato
r light
Yellow light
lighting
If the indicator is not light, check
whether the corresponding network
port is connected to the network
device, the network cable is
connected correctly, the network
cable meets the standard (the
maximum transmission distance of
Category 5 is 100 meters), whether
the network cable is damaged, and
whether the network device is
damaged.
SYS Indicator
light
System
Indicato
r light
Green light
flashing
If the light is off, the device does not
start normally, please restart after
power off.
10GIndicator
light (XG1-
XG4)
Connec
tion
indicati
on
Green light
lighting
If the indicator is not light, check
whether the corresponding interface
is connected to the network device,
the optical module is damaged, and
the network device is damaged.
RJ45ports
ON-S5700-48GP-4TF supports 48 10/100/1000Mbps adaptive RJ45 ports.
Rear panel
Includes: power outlet, power switch, ground terminal
SFP port
ON-S5700-48GP-4TF provides four 10 Gigabit SFP optical module
expansion slots for plugging into Gigabit SFP modules.
Console port
The Console port is used to connect to the serial port of a computer or

other terminal to manage or configure the switch.
Power socket
The power supply to the switch ON-S5700-48GP-4TF must be 100-
240V~ 50/60Hz AC power.
Chapter 2 Hardware Connection
2.1 Connecting RJ45 port
Connect the switch and the RJ45 port of the peer network device with a
network cable.
2.2 Connecting SFP Ports
The SFP port of ON-S5700-48GP-4TF supports only 10 Gigabit fiber modules.
It is recommended to use standard SFP module products.
The process of installing a fiber module on a switch is as follows:
1、Grasp the fiber module from the side and insert it smoothly along the
SFP port slot of the switch until the fiber module is in close contact with the
switch;
2、Confirm the Rx and Tx ports of the fiber module when connecting.
Insert one end of the fiber into the Rx and Tx ports to ensure that the Tx and

Rx ends of the interface are correctly connected, and the other end of the
fiber is connected to another device.
3、After power-on, check the status of the corresponding indicator. If the
indicator is on, the link is up. If the indicator is off, the link is down. Check the
line and confirm that the peer device is enabled.
Note:
It is not allowed to excessively bend the fiber, and its radius of curvature should be no
less than 10cm ;
Ensure the cleanliness of the fiber end face;
Please do not look directly into the fiber optic connector with your eyes, as this may
cause eye damage.
2.3 Check before power-on
Check that the power supply of the power outlet meets the switch specifications.
Check that the power supply, switch, and rack are properly grounded.
Check whether the switch is connected to other network devices.
2.4 device initialization
The switch will automatically initialize after the power is turned on and the power switch
is turned on.
The indicator light will appear as follows:
1、After the power is turned on, the power indicator remains steady. When SYS
enters the flashing state, the system runs normally.
2、The indicator of each port indicates the connection status of each port,
indicating that the switch has started to work normally.
Chapter 3 Product Installation
3.1 Installation Precautions
Note: To avoid damage to the equipment and personal injury caused by improper
use, please observe the following precautions.
safety precautions

power supply remains off during the installation process. Wear an ESD-preventive
wrist strap and ensure that the ESD-preventive wrist strap is in good contact with the
skin to avoid potential safety hazards.
Switch only can work normally under the correct power supply. Please confirm
that the power supply voltage matches the voltage indicated by the switch.
Before powering on the switch, please make sure that the power circuit is not
overloaded, so as not to affect the normal operation of the switch and cause
unnecessary damage.
To avoid the risk of electric shock, do not open the case while the switch is
working, even if it is not charged, do not open it yourself;
Before cleaning the switch, first pull out the power plug of the switch. Do not wipe
with a moist fabric. Do not use liquid to clean.
humidity
In order to ensure long-term stable operation of the switch and prolong its service life,
please maintain a certain temperature and humidity in the environment. Too high or too
low ambient humidity is likely to cause leakage, deformation and even corrosion of metal
parts. If the temperature is too high, the aging process of the insulation material will be
accelerated, which will seriously affect the service life of the equipment. The normal
operation and storage temperature / humidity of this series of switches are as follows
Environmental description temperature Relative humidity
Working Temperature 0℃~40℃10%~90% RHNon-
condensing
Storage Temperature -40℃~70℃5%~90% RHNon-
condensing
elevation
Products with this mark are only suitable for safe use in areas below 2000m above sea
level .
dustproof
Dust falling on the surface of the switch can cause electrostatic adsorption and poor
contact of the metal contacts. Although the device itself has made certain measures in

anti-static, when the static electricity exceeds a certain intensity, it will still cause fatal
damage to the electronic components on the internal circuit board. To avoid the static
electricity affecting the normal operation of the device, please pay attention to the
following:
1、Regular dust removal to keep indoor air clean;
2、Make sure that the equipment is well grounded to ensure the smooth transfer
of static electricity.
interference
Electromagnetic interference will affect the electronic components such as capacitors
and inductors inside the device by means of capacitive coupling, inductive coupling,
impedance coupling, etc. To reduce the adverse effects caused by electromagnetic
interference, please pay attention to the following:
1、The power supply system takes necessary measures against grid interference;
2、The switch should be away from high-frequency, high-power, high-current
equipment, such as wireless transmitters;
3、Take electromagnetic shielding measures when necessary.
lightning protection needs
When a lightning strike occurs, a strong current is generated in an instant, and the air in
the discharge path is instantaneously heated to 20,000 degrees Celsius, and an
instantaneous large current is enough to cause fatal damage to the electronic
device. For better lightning protection, please note the following:
1、Confirm that the rack is in good contact with the ground;
2、Make sure the power outlet is in good contact with the ground;
3、Reasonable wiring to avoid internal induction lightning;
4、When using outdoor wiring, it is recommended to use a signal lightning arrester.
Installation rack requirements
Regardless of whether the switch is installed in a rack or other horizontal workbench,
please note the following:

1、Verify that the rack or table is stable, strong, and capable of withstanding
a weight of at least 5.5 kg;
2、Confirm that the rack itself has a good cooling system, or keep the room well
ventilated;
3、Make sure the rack is well grounded, and the distance between the power
socket and the switch is less than 1.5 meters.
tool preparation
The Phillips screwdriver, electrostatic wrist strap, and cable fiber may be used during
installation.
3.2 Product Installation
19 inch standard rack mount
ON-S5700-48GP-4TF is designed to fit the standard 19-inch rack and can be easily
mounted to the rack. The specific installation steps are as follows::
1、Check the grounding and stability of the rack;
2、Install the two L-shaped brackets in the accessories on both sides of the switch
panel and fix them with the screws provided in the accessories.
3、Place the switch in the proper position in the rack and support it by the bracket.
Fix the L-bracket to the guide groove fixed at both ends of the rack with screws to
ensure that the switch is installed on the rack stably and horizontally.

Note:
Good grounding of the rack is an important guarantee for anti-static, anti-leakage,
lightning protection and anti-interference of the equipment. Therefore, ensure that the
grounding wire of the rack is properly installed.
The equipment installed in the rack is generally from bottom to top to avoid overload
installation;
Avoid placing other heavy objects on the surface of the switch to avoid accidents;
Ensure heat dissipation and air circulation.
3.3 login management interface
Step1、Connect the sw to the computer
Step 2、Change the computer IP to 192.168.254.X (2~254), and the Subnet
mask is 255.255.255.0

Step3、Turn on the browser , input 192.168.254.1, and click Enter
Step4 、Enter the web manage UI, Input the Username and PW, both are admin
and log in
Step5、You already entered the web management UI of the switch and can
start to configure the switch

.
Chapter 4, packing list and recommendations for use
4.1Open the package and check the list below.
Objects Quantity Remark
Switch 1 pc \
Power cable 1 pc Support power to SW
Hook 2 pcs To installation
Warranty Card 1 pc To After sale service
Manual 1 pc To guide the user
4.2 Suggestions
1. For safety reasons, non-professionals should not open the product
case;
2. Pay attention to the danger of strong electricity and safe protection
when the product is powered on;
3. Please select the correct power adapter to supply power to the
switch. Confirm whether it meets the switch requirements before use;
4. Do not use the switch in a humid environment to prevent water from
entering the fuselage through the casing, resulting in damage to the
machine.;
5. Please turn on the power after the line connection is completed;
6. W hen the product is powered on, please do not plug and unplug the

cable if it is not special.;
7. Do not use the switch in places with excessive dust and
electromagnetic radiation. Do not use the switch in a place that is hot and not
ventilated.;
8. Please do not place heavy objects on the switch to avoid
accidents.;
9. It is recommended to use the switch indoors. It is recommended to
add a waterproof box when using it outdoors.。
Note: The pictures in the manual are for reference only, whichever is
subject to the actual product.
Table of contents
Other Wizard Switch manuals
Popular Switch manuals by other brands

A-Neuvideo
A-Neuvideo ANI-4KHPN instruction manual