Woodway PPS Series User manual

Fall Protection System
Accessories for WOODWAY Slat-Belt Treadmills
from the Medical PPS Series
Original Version of the Woodway PPS Series Accessories
O erating Instructions
Version: 12/2015-v1.0en

Manufacturer:
WOODWAY GmbH
Steinackerstr. 20
95 6 Weil am Rhein
Germany
Tel.: +49 (0) 621 - 940 999 - 0
Fax.: +49 (0) 621 - 940 999 - 40
E-Mail: [email protected]
Web: www.woodway.de
Sales:
Tel. +49 (0) 621 - 940 999 - 10
E-Mail: vertrieb@woodway.de
Customer Service:
Tel. +49 (0) 621 - 940 999 - 14
E-Mail: service@woodway.de

Table of Contents
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
3
Table of Contents
1 Introduction ............................................................................................. 5
1.1 Operating Instruction Information ................................................. 5
1.2 Model Designations ...................................................................... 6
1.3 Limitation of Liability ....................................................................
1.4 Copyright ....................................................................................
1.5 Replacement Parts .......................................................................
1.6 Customer Service ......................................................................... 8
1. EC Declaration of Conformity ........................................................ 9
2 Safety .................................................................................................... 10
2.1 General ..................................................................................... 10
2.2 Description of Warning Notices ................................................... 10
2.3 Personnel Qualification and Responsibility .................................... 11
2.4 Intended Use ............................................................................. 12
2.5 Unauthorized Modes of Operation ............................................... 13
2.6 Safety Requirements for Chest-Shoulder Harnesses ...................... 13
2. Intended Use / Indications .......................................................... 14
2.8 Contraindications ....................................................................... 14
3 Technical Data ....................................................................................... 15
3.1 Name Plate ................................................................................ 15
3.2 Chest-Shoulder Harness.............................................................. 16
3.3 Technical Specifications .............................................................. 1
4 Transportation and Storage ..................................................................... 18
4.1 Safety Notices for Transportation ................................................ 18
4.2 Storage ..................................................................................... 18
5 Product Description ................................................................................ 19
5.1 Main Components ...................................................................... 19
5.2 Function Description ................................................................... 20
5.3 Chest-Shoulder Harness.............................................................. 21
6 Commissioning ....................................................................................... 22
6.1 General ..................................................................................... 22
6.2 Installation ................................................................................ 22
6.3 Chest-Shoulder Harness.............................................................. 23
6.3.1 Safety Buckle .................................................................. 24
6.3.2 Applying the Chest-Shoulder Harness ................................ 24
6.3.3 Connecting the Chest-Shoulder Harness with the Fall
Protection System .......................................................... 2
6.4 Adjusting the Fall Protection System ............................................ 28
6.5 Fall Protection Emergency Stop ................................................... 29
Maintenance and Cleaning ...................................................................... 31
.1 Cleaning .................................................................................... 31
.2 Maintenance Intervals ................................................................ 32
.2.1 Daily Maintenance ........................................................... 32
.2.2 Weekly Maintenance ........................................................ 32
.2.3 Annual Maintenance ......................................................... 32
.3 Chest-Shoulder Harness.............................................................. 33
.3.1 Maintenance .................................................................... 33
.3.2 Cleaning .......................................................................... 34

Table of Contents
4
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
8 Instruction Record .................................................................................. 35
9 Disposal ................................................................................................. 3
10 Table of Figures ..................................................................................... 38

Introduction
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
5
1Introduction
1.1 O erating Instruction Information
Read these accessories operating instructions before using the Woodway PPS Series
fall protection system in conjunction with a PPS slat-belt treadmill. These operating
instructions contain important information regarding safety, operation and
maintenance. Ensure these instructions are available to all persons who are
responsible for the operation and maintenance of the unit.
NOTE
These operating instructions and the Woodway PPS Series treadmill instruc-
tions must always be read before using the Woodway PPS Series fall protec-
tion system!
ATTENTION
Danger of Injury Through Im ro er A lication!
If the PPS fall protection system is not used in conjunction with a Woodway
PPS Series treadmill, or it was not installed by a trained expert, serious acci-
dents can occur.
►The Woodway PPS Series fall protection system may be used exclusively
with PPS treadmills!
►The installation may only be carried out by WOODWAY employees or au-
thorized experts.
One condition for safe commissioning is compliance with all safety and operating in-
structions.
CAUTION
Im ro er o eration can cause accidents!
Not using the Woodway PPS Series fall protection system as intended accord-
ing to the manufacturer's instructions can cause accidents and equipment
damage.
►These operating instructions must be completely read and understood be-
fore using the treadmill.
►Keep these instructions close at hand for all users of the device.
Read and observe the o erating instructions!
Read these instructions carefully before beginning any work on
the treadmill! It is a part of the device and must be kept acces-
sible at all times and in the immediate vicinity of the treadmill
for operating and maintenance personnel.
ATTENTION!

Introduction
6
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
WOODWAY GmbH accepts no liability for accidents, equipment damage and conse-
quences of equipment failure that are a result of failure to follow the operating
instructions. In addition, the local accident prevention regulations and general
safety conditions for intended use of the treadmill apply.
The manufacturer reserves the right to make technical changes in the context of
improving the performance properties and further development without prior notice.
Illustrations are for basic understanding and may differ from the actual design of
the device.
Accessories from other suppliers have further safety regulations and guidelines.
These must also be observed.
1.2 Model Designations
The fall protection system must be selected according to the associated PPS model:
•ST PPS 43 Med (Med-i)
•ST PPS 55 Med (Med-i)
•ST PPS 0 Med (Med-i)
•ST PPS 43 Ortho
•ST PPS 55 Ortho
•ST PPS 0 Ortho
•ST PPS 43 Plus
•ST PPS 55 Plus
•ST PPS 0 Plus
The fall protection system is an accessory and may only be used in combination
with treadmills from the Woodway medical PPS series.
The following designates which fall protection systems and treadmill models
(PPS series) may be used in combination:
Model Designations
Fall Protection Systems Woodway PPS Series Treadmills
ST PPS 43 Med (Med-i) PPS 43 Med (Med-i)
ST PPS 55 Med (Med-i) PPS 55 Med (Med-i)
ST PPS 0 Med (Med-i) PPS 0 Med (Med-i)
ST PPS 43 Ortho PPS 43 Ortho
ST PPS 55 Ortho PPS 55 Ortho
ST PPS 0 Ortho PPS 0 Ortho
ST PPS 43 Plus PPS 43 Plus
ST PPS 55 Plus PPS 55 Plus
ST PPS 0 Plus PPS 0 Plus
Observe the
instructions!

Introduction
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
1.3 Limitation of Liability
All information and instructions in this manual have been compiled in accordance
with applicable standards and regulations, the current state of technology and our
knowledge and experience.
WOODWAY GmbH accepts no responsibility for damages resulting from:
•Disregarding the operating instructions.
•Improper use.
•Use by non-authorized persons.
•Use of replacement parts which were not approved by WOODWAY GmbH.
•Unauthorized modifications to the device or accessories.
The WOODWAY GmbH general terms and conditions and delivery conditions
apply, as well as the legal regulations valid at the time of contract establishment.
1.4 Co yright
The release of the operating instructions to third parties without the written permis-
sion of WOODWAY GmbH is prohibited.
NOTE
All contents, text, drawings, images or other illustrations are copyright pro-
tected and are subject to intellectual property rights.
Any misuse is punishable by law!
Duplication in any manner or form - including excerpts - as well as use and/or
communication of the content are not permitted without written permission from
WOODWAY GmbH.
1.5 Re lacement Parts
WOODWAY GmbH recommends the use of original replacement parts. Original
replacement parts have particular qualities and ensure reliable and safe operation;
•Developed for specific use with the device.
•Manufactured in high quality and excellence.
•Ensure the legal warranty period.
(excluding wear parts) or other reached agreements.
NOTE
The use of NON-original replacement parts may change the characteristics of
the device and interfere with the safe use!
WOODWAY GmbH does not accept liability for damages resulting from this.
Wear parts are considered hazardous waste! After being replaced, wear parts must
be disposed of according to country-specific waste laws.
For further information on disposal, see section 8 page 35.
Dis osal!

Introduction
8
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
1.6 Customer Service
For service questions contact the following:
WOODWAY GmbH
Steinackerstr. 20
95 6 Weil am Rhein
GERMANY
Tel. +49 (0) 621 - 940 999 - 14
Fax. +49 (0) 621 - 940 999 - 40
Email: service@woodway.de
For faster processing of your request please have the following data and infor-
mation available:
•Information from the device nameplate (specific model/serial number).
•An accurate description of the circumstances.
•What action has already been taken?
When servicing the Woodway PPS Series fall protection system and connected
devices on site, all devices must be disconnected from the power supply by a
qualified electrician so that the device(s) cannot switch on accidentally.
The address of your local service provider can be obtained from the manufacturer.
After repair or re-commissioning, the actions listed under "Installation" and "Com-
missioning" are to be performed as during commissioning.
Contact:
Servicing:

Introduction
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
9
1.7 EC Declaration of Conformity
Fig. 1 EC Declaration of Conformity, PPS Fall Protection System

Safety
10
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
2Safety
2.1 General
The Woodway PPS Series fall protection system has been reliably designed, manu-
factured and tested according to the latest state of technology and is in safe and
technically perfect condition. Nevertheless, the device can cause risk to persons and
property if it is operated improperly.
For this reason the operating instructions should be read completely and safety in-
structions must be observed.
Warnings attached directly to the device must be observed and kept in a legible
condition.
Inappropriate use will result in the rejection of any liability or guarantee by
WOODWAY GmbH.
2.2 Descri tion of Warning Notices
Warning notices indicate potential hazards or safety risks. They are indicated in this
manual by a color-coded signal word panel (symbol with the appropriate signal
word).
All warning notices have the same design and the same standardized content de-
sign.
Sam le of a Warning Notice:
SIGNAL WORD
Warning Text, Ty e and Source of Danger
Description of the consequences of ignoring the danger.
►Measures, instructions and forbidden actions to avoid the hazard.
►Further measures...
Classification:
NOTE
NOTE or WARNING (no danger symbol).
No risk of injury, pertinent information and warning
against material damage.
CAUTION
CAUTION (with danger symbol).
Slight possibility of injury.
WARNING
WARNING (with danger symbol).
In a dangerous situation a serious accident is possible
with the possibility of injury or death.
DANGER
DANGER (with danger symbol).
In the event of an accident immediate danger of
death or serious injury.

Safety
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
11
2.3 Personnel Qualification and Res onsibility
WARNING
Danger Due to Im ro er Use!
Improper handling of the device can lead to serious personal injury and prop-
erty damage.
►The device may only be operated by persons who have received instruc-
tions from qualified service personnel.
►WOODWAY GmbH recommends the use of a training record (see appen-
dix) for proof of instructions.
The representative is the person or company that is responsible for setting up, use
and maintenance of the device.
The representative of the device is responsible for the regular maintenance and
testing as required by law. They are also obligated to provide adequate train-
ing/instruction to the operating personnel. WOODWAY GmbH recommends the
training be carried out by a trained and authorized WOODWAY dealer or service
partner.
Operators of medical devices are persons who use the device and have the "power
of control" over the device. This can be e.g. therapists, doctors, sports physicians or
any other supervisory personnel. The operator of a medical device is any person
who - regardless of their qualifications - independently uses a medical product in
the commercial sector.
The operator is personally responsible for the safety of the user (e.g. patient, test
subject). Due to the high degree of responsibility these persons have a special obli-
gation to provide information on all aspects of safety of the device and its intended
use.
ATTENTION
Com liance with the Legal Provisions of the Federal Re ublic of
Germany!
To protect the user, operators and representatives are required to consider
the following legal regulations and laws when using the device in combination
with a treadmill:
►MPG: Laws regarding medical products (Medical Devices Law)
►MPBetreibV: Regulation on the installation, operation and use of medical
devices (Medical Device Use Directive)
►MPSV: Regulation on the identification, evaluation and prevention of risks
associated with medical devices (Medical Device Safety Directive)
For further information on the national regulations for the use of this device, con-
tact your authorized WOODWAY dealer.
Re resentative:
O erator:

Safety
12
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
2.4 Intended Use
WARNING
Danger from Im ro er Use!
Any improper use and/or other use of the device can lead to dangerous situa-
tions with significant personal injury and/or property damage.
►Only use the Woodway PPS Series fall protection system for its intended
use.
►Woodway PPS Series fall protection systems may only be used in combina-
tion with the associated WOODWAY Medical PPS Series slat-belt treadmills.
►Read and observe all information in these instructions and in the Woodway
PPS Series treadmill instructions.
The fall rotection systems for WOODWAY Medical PPS Series slat-belt
treadmills are designed to revent falling and accidents.
The Woodway PPS Series fall rotection serves exclusively as a safety
system in case a atient falls. The ro e ull triggers the treadmill emer-
gency sto and the atient's body weight is held by the atient harness.
The operating instructions are an integral part of the device and are to be available
to all users at all times. The exact observance of the instructions is a prerequisite
for the intended use of the WOODWAY device.
Special attention must apply to these user groups. Compared to treadmill exercise
with healthy people the risk of injury is considerably higher with these users. Strict
adherence to and compliance with all safety instructions and operating information
is the highest priority.
The patient may only use the treadmill and the Woodway PPS Series fall protection
system under the supervision of a physician and/or therapist! The training program
must be medically prescribed and monitored.
ATTENTION
Claims to the manufacturer of any kind due to damage from improper use are
excluded.
The representative alone is liable for all damages resulting from improper use!
S ecial User Grou s!

Safety
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
13
2.5 Unauthorized Modes of O eration
The Woodway PPS Series fall protection system may only be used for the aforemen-
tioned purpose. Any additional uses may result in serious personal injury and/or
property damage.
The following restrictions and prohibitions must be strictly adhered to:
•The Woodway PPS Series fall protection system may not be used without prior
instruction by qualified personnel.
•Children may not use the device or be left near the device unattended.
•The use of the Woodway PPS Series fall protection system under the influence
of alcohol or drugs and/or narcotics is prohibited.
•The lifting of objects with the Woodway PPS Series fall protection system is
prohibited.
•The Woodway PPS Series fall protection system may not be used on animals!
•When being used in conjunction with a Woodway PPS Series treadmill, the
safety instructions in this manual and in the Woodway PPS Series treadmill
manual must be observed.
2.6 Safety Requirements for Chest-Shoulder Harnesses
The following instructions are to be observed for the safe use of chest-shoulder
harnesses:
•Never use the chest-shoulder harness differently than described in the operat-
ing instructions.
•The harness may only be used under the supervision of trained nursing and
support staff.
•The nursing staff (operator) must have the necessary expertise to select and
use the appropriate harness.
•Check the harness for the correct size and shape in relation to the patient, use
only the prescribed patient harnesses.
•Ensure that the harness is not too big for the patient. Otherwise there is a risk
that the patient will slip out or body parts will be crushed.
•Use only prescribed snaplinks.
•Check for safe condition of the harness before using it. The material must not
be torn and the seams must not be damaged.
•The recommended maximum load must not be exceeded.
•When selecting the size of the belt, the patient's physical condition is to be
considered.
•Always ensure that the belt is applied properly. Never leave the patient unat-
tended when in the harness.
•In case of obstructing equipment such as probes, catheters, etc., and/or the
patient has taken mind-altering drugs, the attending physician must give ap-
proval before the patient harness is used.
•For patients with decreased sensitivity or decreased pain threshold, the use
the harness is only permitted under a physician's direct supervision. The deci-
sion on the use of the belt must be made by the attending physician.
•The harness may not be used on patients with skin diseases or other infectious
diseases.
•Discontinue use immediately if the patient experiences nausea, dizziness, chest
or body pain.
•Persons may not be in the immediate vicinity of moving parts.
•Maintenance and repair work may only be performed by authorized specialists!

Safety
14
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
2.7 Intended Use / Indications
The Woodway PPS Series fall protection system and its individual models are acces-
sories for Woodway PPS series treadmills. The fall protection system may be used
exclusively in combination with medical PPS series treadmills.
Since the fall protection system is an accessory for the Woodway PPS series tread-
mills, the same indications apply, which have already been mentioned in the intend-
ed use of Woodway medical PPS Series slat-belt treadmills.
In addition, a fall protection system with emergency stop is recommended / re-
quired for the following medical fields of application:
•Performance Diagnostics (step test, ramp tests for maximum exertion of the
athlete).
•Running analysis with direction reversal.
•Insufficient safe distance behind the treadmill
(Less than 200 x 100 cm) or in front of the treadmill, if direction reversal is
used.
•Treadmills with running surfaces larger than 15 x55 cm.
•Therapy with children.
•Therapy with patients who can stand/walk but are prone to falling
(Due to age or illness / disability).
The use of fall protection is not required for everyday use in medical applications,
such as warming up for medical training therapy or cardiovascular training.
2.8 Contraindications
Since the fall protection system is an accessory for the Woodway PPS Series tread-
mills, the same contraindications apply, which have already been mentioned in the
intended use of Woodway medical PPS Series slat-belt treadmills.
Furthermore, use is prohibited under the following conditions:
•Body weight less than 200 kg (chest-shoulder harness sizes M and L)
•Body weight less than 100 kg (chest-shoulder harness size S)
•Body weight less than 15 kg (triggering force rope pull switches)
•Osseous instability in the chest area (non-consolidated fractures, unstable
spine, severe osteoporosis)
•Open skin lesions in the torso area.
The attending physician and competent therapist are responsible for assessing the
therapy capability and thus for making individual decisions for each patient, deter-
mining possible risks and side effects of therapy compared to their benefits.

Technical Data
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
15
3Technical Data
3.1 Name Plate
The nameplate contains the device's main technical details. For service questions,
the technical information on the nameplate must be kept handy.
Fig. 2 Nameplate, PPS Fall Protection
1. Note to read and observe the operating instructions!
2. Device CE symbol
3. Serial number
4. Year manufactured
5. Max. body weight
6. Disposal note
. Name plate
8. Product description
9. Manufacturer name, address and logo, website
4
9
7
1
2
5
8
6
3

Technical Data
16
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
3.2 Chest-Shoulder Harness
On the inside of chest-shoulder harness there is a patch containing information on
the harness and instructions for care.
Fig. 3 Nameplate, Chest-Shoulder Harness
1. Manufacturer name, address and logo, website
2. Product description
3. Size specifying chest size
4. Max. body weight
5. Production code
6. Instructions for care
. Note to read and observe the operating instructions!
8. Year of manufacture (calendar week / year) with CE mark
1
8
2
3
4
5
6
7

Technical Data
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
1
3.3 Technical S ecifications
Technical s ecifications and PPS series fall rotection characteristics
Product description: Fall protection for WOODWAY Slatted Treadmills from the
Medical PPS Series
Name plate: ST PPS 43 Med (Med-i)
ST PPS 55 Med (Med-i)
ST PPS 0 Med (Med-i)
ST PPS 43 Ortho
ST PPS 55 Ortho
ST PPS 0 Ortho
ST PPS 43 Plus
ST PPS 55 Plus
ST PPS 0 Plus
Medical product class: I (according to appendix IX rule 1 directive 93/42/EWG)
Mode of operation: This device is designed for continuous operation.
Maximum user weight for fall protection 200 Kg
Maximum user weight for chest-shoulder
harness
Sz. S 100 Kg
Sz. M 200 Kg
Sz. L 200 Kg
Special design 200 Kg
Pull-rope switch triggering force ≥ 15 Kg
Minimum ceiling height Standard setting 260 cm
Lowest setting 250 cm
Maximum user height 210 cm
Chest-shoulder harness design Sz. S, chest size 40 – 65 cm, color markings, blue
Sz. M, chest size 65 - 90 cm, color markings, yellow
Sz. L, chest size 90 - 115 cm, color markings, red
Special designs on request
Fall-stop line length Individually adjustable
Access to patient On all sides
Device color white / black
The ST PPS Med/Ortho/Plus color should be identical with the
treadmill frame color
Dimensions assembled
ST PPS 43 Med (Med-i) 123 cm x 80 cm x 239 (249) cm (L x W x H)
ST PPS 55 Med (Med-i) 123 cm x 92 cm x 239 (249) cm (L x W x H)
ST PPS 0 Med (Med-i) 123 cm x 10 cm x 239 (249) cm (L x W x H)
ST PPS 43 Ortho 123 cm x 80 cm x 239 (249) cm (L x W x H)
ST PPS 55 Ortho 123 cm x 92 cm x 239 (249) cm (L x W x H)
ST PPS 0 Ortho 123 cm x 10 cm x 239 (249) cm (L x W x H)
ST PPS 43 Plus 123 cm x 80 cm x 239 (249) cm (L x W x H)
ST PPS 55 Plus 123 cm x 92 cm x 239 (249) cm (L x W x H)
ST PPS 0 Plus 123 cm x 10 cm x 239 (249) cm (L x W x H)
Ambient storage conditions
Ambient temperature: -10 to +50 °C
Atmospheric pressure: 500 to 1050 hPa
Relative humidity: 10 - 90 % (not condensed)
Ambient operating conditions
Ambient temperature: +10 to +40 °C
Atmospheric pressure: 800 to 1050 hPa
Relative humidity: 30 - 80 % (not condensed)
Weight
PPS series fall protection total weight: 53 kg to 59 kg (depending on design)

Transportation and Storage
18
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
4Trans ortation and Storage
4.1 Safety Notices for Trans ortation
Check the PPS fall protection system for damage upon arrival. Also check and com-
pare supplied accessories with the corresponding delivery note.
The manufacturer is not liable for damages and missing parts if this information was
not recorded in writing on the delivery note upon delivery of the unit. Damage or
defects must be reported to the carrier and to the responsible WOODWAY dealer
immediately.
WARNING
Risk of Injury by Machine Falling Over!
Improper transportation of the device may lead to it falling over and causing
injury or equipment damage.
►Only transport in compliance with the safety regulations.
►Carry the device components with at least two persons.
►Ensure stable center of gravity and steadiness in all described modes of
transportation.
If necessary, transport or relocation can be carried out by authorized WOODWAY
service partners.
For further information please contact WOODWAY customer service.
4.2 Storage
The device may only be stored in closed, dry rooms. It is absolutely necessary to
prevent contact with moisture (rain, fog, etc.)
The following environmental conditions are prescribed for transportation and stor-
age:
•Temperature: -10°C to +50°C
•Atmospheric pressure: 800 to 1050 hPa
•Relative humidity: 10 - 90% (not condensed)
WOODWAY Service:

Product Description
12/2015
Woodway PPS Series Accessories / Fall Protection Operating Instructions
19
5Product Descri tion
5.1 Main Com onents
The following figure shows the main components:
Fig. 4 Components
1. Height adjustment, on both sides (2 positions)
2. Bearing rope / pull cord
3. Suspension frame
4. Frame mounting bracket, on both sides
5. Rope pull switch with emergency stop and release
6. Mount to substructure
. Rope winding
8. Rope length adjustment via cable lock with pawl mechanism
9. Snaplink for chest-shoulder harness
1
3
2
4
6
8
9
5
7
1

Product Description
20
Woodway PPS Series Accessories / Fall Protection Operating Instructions
12/2015
5.2 Function Descri tion
Despite compliance with all safety requirements, there is till the risk of injury to the
user when using a treadmill. During intense exercises and practices, or prolonged
exercise duration, the user's constitution and concentration can decrease which in-
creases the risk of falling. There is an increased risk of injury from falling, especially
in rehabilitation where patients with various physical limitations use the treadmill.
To minimize the risk of injury on the treadmill, a fall protection system with
•a suspension frame,
•a chest-shoulder harness,
•and an emergency stop system
can prevent the user from falling. The use of a fall protection system can prevent
serious injury/abrasions which are caused by the impact of the whole body on the
moving running surface or backwards movement.
The additional integration of the fall protection system in the emergency stop
control circuit, causes the tread to stop immediately in case of a fall.
In addition to the emergency stop function, the fall protection system catches the
user in case of a fall.
The chest-shoulder harness is designed so that the body cannot tip forward. The
harness does not cut into the user or constricted the user's movement. The chest-
shoulder harness is available in sizes S, M, and L and is connected via a pull line
(rope) with emergency stop system on the suspension frame. If there is more than
15 kg force on the emergency stop system, the treadmill stops immediately. The
maximum body weight (working load) is 200 kg. The length of the line (rope) can
be individually adjusted to different body sizes.
ATTENTION
There is a risk of injury from not observing the weight limit!
If too little weight is applied the emergency stop will not be triggered! There
is a danger of injury!
►The PPS fall protection system may not be used below a weight of 15 kg.
Emergency Sto
Chest-Shoulder
Harness
This manual suits for next models
12
Table of contents
Popular Security Sensor manuals by other brands

System Sensor
System Sensor WFDEXP Installation and maintenance instructions

CRL JACKSON
CRL JACKSON 2085 installation instructions

ST
ST STM8T Application note

SEDEA
SEDEA no-531440-2211 installation instructions

Bosch
Bosch DS835I Series installation instructions

Edimax
Edimax AI-1001W V2 Quick installation guide

Hitachi
Hitachi SOR-NEC Installation and operation manual

Emerson
Emerson Machinery Health AMS EZ 1000 operating manual

Covidien
Covidien Nellcor PEDICAP Instructions for use

AJAX
AJAX LeaksProtect user manual

PCB Piezotronics
PCB Piezotronics ICP W105C02/038AG020AC Installation and operating manual

DoCash