manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bosch
  6. •
  7. Security Sensor
  8. •
  9. Bosch DS940 User manual

Bosch DS940 User manual

This manual suits for next models

1

Other Bosch Security Sensor manuals

Bosch ISC-BDL2-W12 User manual

Bosch

Bosch ISC-BDL2-W12 User manual

Bosch ISC-BDL2-WP6 User manual

Bosch

Bosch ISC-BDL2-WP6 User manual

Bosch Blue Line P1 User manual

Bosch

Bosch Blue Line P1 User manual

Bosch PMD 7 User manual

Bosch

Bosch PMD 7 User manual

Bosch RF835E User manual

Bosch

Bosch RF835E User manual

Bosch AVENAR detector4000 User manual

Bosch

Bosch AVENAR detector4000 User manual

Bosch TriTech+ Professional ISC-PDL1-WAC30G User manual

Bosch

Bosch TriTech+ Professional ISC-PDL1-WAC30G User manual

Bosch D-tect 150 Professional User manual

Bosch

Bosch D-tect 150 Professional User manual

Bosch RF920 User manual

Bosch

Bosch RF920 User manual

Bosch DS938Z Series User manual

Bosch

Bosch DS938Z Series User manual

Bosch D-tect 150 Professional User manual

Bosch

Bosch D-tect 150 Professional User manual

Bosch DS9360 User manual

Bosch

Bosch DS9360 User manual

Bosch RADION PIR RFPR-12 User manual

Bosch

Bosch RADION PIR RFPR-12 User manual

Bosch DS9360 User manual

Bosch

Bosch DS9360 User manual

Bosch Photobeam 3000 ISC-FPB1-W30DS User manual

Bosch

Bosch Photobeam 3000 ISC-FPB1-W30DS User manual

Bosch Truvo User manual

Bosch

Bosch Truvo User manual

Bosch FCA-350-B4 User manual

Bosch

Bosch FCA-350-B4 User manual

Bosch DS308EA User manual

Bosch

Bosch DS308EA User manual

Bosch ISC-CDL1-W15G User manual

Bosch

Bosch ISC-CDL1-W15G User manual

Bosch ISC-SM-90 User manual

Bosch

Bosch ISC-SM-90 User manual

Bosch ISN-SM-50 User manual

Bosch

Bosch ISN-SM-50 User manual

Bosch Photobeam 5000 Operating instructions

Bosch

Bosch Photobeam 5000 Operating instructions

Bosch DS820 Safety guide

Bosch

Bosch DS820 Safety guide

Bosch DS835I Series User manual

Bosch

Bosch DS835I Series User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DS940/DS940T
Passive Infrared Detector
Installation Instructions
1.0 Description
The DS940 is a high performance Passive Infrared (PIR) Motion Sensor which uses advanced signal processing to provide outstanding
catch performance and unsurpassed false alarm immunity. It is designed to detect movement in the interior of a structure by sensing the
Infrared energy emitted from the human body as it moves across the sensor’s field of view. When motion is detected the unit sends an alarm
signal to the control panel.
2.0 Specifications
•Input Power: 9-15 volts DC
•Current Draw: 17 mA @ 12 VDC (standby and maximum)
•Standby Power: Nointernalstandbybattery. For ULListedProd-
uct Installations, 4 hours (68 mAh) standby
power must be provided by the control unit or
by a Listed burglary power supply.
•Relay Form “A” Normally Closed (NC) contact set
rated for 125 mA@ 28 volts maximum DC, 18
volts maximum AC for resistive loads.
•Tamper: (DS940T only) NormallyClosed(withcoveron).
Contacts rated at 28 VDC, 125 mA max. Con-
nect tamper circuit to a 24hr. protection circuit.
•Temperature: -20° to +120°F (-29° to +49°C).
For UL Listed installations, the temperature
range is +32°F to +120°F (0°C to +49°C).
•Humidity: 0 - 85% non-condensing.
•Dimensions: 3 in. x 2.25 in. x 1.5 in. (HxWxD)
(7.6 cm x 5.7 cm x 3.8 cm)
•Options: B335 Swivel Mounting Bracket. Use of this
bracket may decrease the PIR range and in-
crease dead zones.
• Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at: http://www.boschsecurity.com/
datecodes/
.
3.0 Installation
3.1 Remove the cover using a
smallflat-bladescrewdriver.
3.2 Press the vertical adjust
tab toward the side of the
case and lift out the board.
3.3.
3.3.
3.4 Avoid.
3.3 Select a mounting location.
Mount the sensor where an
intruder will most likely cross
throughthecoverage pattern.
Bottom of Detector
Insert screwdriver here or here
LED
ON
7.5-9ft
3.3.
3.3.
3.5 Position the detector at the correct height.
7.5 - 9 ft.
(2.25 - 2.7 m)
Mount the detector 7.5 - 9 feet
(2.25 - 2.7 meters) above the floor
Moving Objects
Pets
Heat
Sources
Windows
and
Uninsulated
Walls
Air
Conditioning
Outlets
Direct Hot or
Cold
Drafts
Mounting
Outdoors
Direct Sunlight
2/11
DDS940/DS940T Installation Instructions
P/N: F01U035117-08 Page 2
© 2011 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, New York 14450
www.boschsecurity.com
3.10 If look-down is desired, peel away the look-down
mask. Do not remove the clear plastic lens.
5.0 Coverage Patterns
3.9 Select LED Operation
3.8 Wire the Detector.3.7 Install the board into the case.
Be sure the vertical adjust tab
aligns with the correct mounting
height.
4.0 Walk test the detector. This test should
beperformed at thetime of installationand
annuallythereafter.
Thisdetectorcontainsanenvironmental
stabilization circuit which requires
approximately 2 minutes after initial
power-up to warm up. During this time
the detector will not respond to any
movement.
Please wait 2 minutes after initial power-
up to perform any walk tests.
3.6 Mount the unit, using the appropriate
mountingholes.
LED
ON
7.5-9ft
7.5-9ft
OFF
ON
LED
ON
7.5-9ft
ON
Peel away
the mask
LED
ON
7.5-9ft
LED
ON
+
-
9-15
VDC Alarm
Contacts Tamper
Contacts
Normally Closed (NC) contacts
(DS940T
only)
Note:To avoid possible
circuit board
damage, use
only the
mounting
hardware
provided in the
appropriate
punch-out
mounting holes.
Corner Mount
Surface
Mount
Thinwall knockouts
for wiring
Don't overtighten the mounting screws
Cover may not attach correctly
Remove
Areas
if using the
B335 Bracket
Althoughgenerallynot required,if
maskingis desired,the lensdiagram
showsthe appropriate areasto be
masked(see shaded areaon the
DS940lens diagram).Usean
opaquematerial (suchas, electrical
tape)to mask thedesired areas.
1 234567891011
12 22
23 33
34 44
45 55
56 66
67 77
DS940 Lens
(inside view)
0
40
10
20
20
10
010
20
30
0
012
6
6
Meters
Feet
123
4
5
6
7
8
9
10
11
40
30
2010
0
0
0
10 123
0
7.5
Feet
Meters
Look
Down
67-
77 56-
66 45-
55 34-
44 23-
33 12-
22 1-
11