Woosung RC400 User manual

Thank you for purchasing the dual purpose RC400 Wired Digital Door Key / Digital Touch Pad.
1 COMPOSITION & SPECIFICATIONS
Wired Digital Door Key (RC400)
Mounting screws (4x16)
Mounting template
Connection wire
1EA
2EA
1EA
1EA
User’s Manual 1 copy
Power supply
Relay contact capacity
Operating temperature
Type
Power consumption
International Protection
DC 12~30V, AC 12~24V
DC30V / 1A
-20℃~50℃
ISO14443A(Mifare) / 13.56MHz
300mA Under
IP54 (water proof)
CompositionSpecification
Digital
Wired Door Key (RC400)
User Guide
2 DIMENSION
Unit : mm
3 OPERATION CHECK & CAUTION
5 CONTACT TIME
4 HOW TO USE
1. Be sure to connect DC12 ~ 30V / AC12 ~ 24V.
2. When it powers on, the LEDs will be displayed sequentially: once all LEDs have been displayed, “beep” sound is heard.
3. Since this system is capacitive touch type, it will not respond to a gloved hand.
①②③④ ⇒ ①②③④ ⇒ # ⇒ ① ⇒ # ⇒ Access card (Serial registration is possible) ⇒ # ⇒ * (end)
①②③④ ⇒ ①②③④ ⇒ # ⇒ ① ⇒ # ⇒ Card address(0001~0500) ⇒ Card ⇒ # ⇒ * (end)
Example) Serial registration : if the first address is [0100], next address is [0101] automatically increase.
①②③④ ⇒ ①②③④ ⇒ # ⇒ ③ ⇒ # ⇒ Card address (4digit or serial delete) ⇒ # ⇒ * (end)
4)
[Contact Time]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑤ ⇒ # ⇒ 01~60 (01~60sec.) ⇒ # ⇒ * (end)
Example) Setup 2sec : 0+2, 20sec : 2+0 (Default value: 2sec)
5)
[All Card Delete]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑥ ⇒ # (end)
6)
[All Password Delete]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑦ ⇒ # (end)
7)
[Card or Password Delete]
Card : ①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑧ ⇒ # ⇒ Access Card (Serial possible) ⇒ # ⇒ * (end)
Password : ①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑧ ⇒ # ⇒ Password ⇒ # ⇒ * (end)
8)
[Toggle mode contact change]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ②ⓞ ⇒ # ⇒ Set value (ⓞ~①) ⇒ # (end)
Set value - ⓞ : Normal , ① : Toggle mode (Default value : ⓞ)
9)
[Operation mode setting]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ⑨ ⇒ # ⇒ Set value (ⓞ~①) ⇒ # ⇒ * (end)
Set value - ⓞ:NO, ①: NC (Default value : ⓞ)
10)
[Touch switch mode setting]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ①① ⇒ # ⇒ Set value (ⓞ~①) ⇒ # (end)
Set value - ⓞ: touch switch mode is activated, ①: touch switch mode is deactivated (Default value : ⓞ )
For more detailed information, please refer to the back page “setting touch function to active”
11)
[Illumination brightness setting]
①②③④ ⇒ ①②③④ ⇒ # ⇒ ①② ⇒ # ⇒ Set value ⓞ~⑨) ⇒ # ⇒ * (end)
Set value -ⓞ: Illumination OFF, ⑨: The highest degree of brightness (Default value : ② )
In case brightness of the illumnination is set at off, press touch pad then the numbers will be appeared.
12)
[System number change]
①②③④ ⇒ ①②③④ ⇒ # ⇒ * ⇒ # ⇒ # ⇒ Number in use ⇒ # ⇒ New Number ⇒ # (end)
System number must be 4 digits (Default value : 1234)
13)
[System Initialization]
①②③④ ⇒ ①②③④ ⇒ * ⇒ # ⇒ Initializing ⇒ Exit after the LEDs blink. ⇒ (end)
①②③④ ⇒ ①②③④ ⇒ # ⇒ ② ⇒ # ⇒ Password(4digit) ⇒ # ⇒ * (end)
(Serial registration)
Power (DC 12~30V, AC 12~24V)
Yellow
Yellow
White
White
Gray
Gray
External Input
Output Contact
2)
[Password Registration]
3)
[Card address Delete]
1)
[Card Registration]
6 EM LOCK WIRING
Output Contact
EM Lock
Adapter
Wiring
Wired Digital
Door Key
20
41
150
3 GENERAL INFORMATION
Unfasten the screw,
and use a flat blade (⊖)screwdriver
to disassemble it,
as shown in the figure below.
Water proof pad (Silicone rubber)
Between outside gaps
Screw for
disassembling
/assembling
Lower case
Connection
wire hole
Mounting screws
Disassembling the upper case
Water proof pad (Silicone rubber)
(When assembling the product,
the water proof pad should
not be twisted)
: Error : Touch : Acon / Set
Upper case
Button
※ Use after removing the protective film
*

Digital
Wired Door Key (RC400)
User Guide [Setting Touch function to active]
button => password (4 digits) => password (4 digits) => #
(whenever a change is made, this function toggles between Enabled (active) and Disabled (inactive)
[Caution!] To use touch feature set the Touch function menu on 1) firstly.
[Setting Touch Function to inactive]
button => password (4 digits) => password (4 digits) => #
(whenever a change is made, this function toggles between Enabled (active) and Disabled (inactive)
[Caution!] To use touch feature set the Touch function menu on 1) firstly.
[Open a door]
Password (4 digits) ⇒ # (If more than 4 digit password is entered,
j
ust the last four digits should be identical (right) with your preset
password to open the door.)
Password (4 digits) → #
Key in the following digits
1234 → 1234 → # → 1 → #
Access Card (Serial registration is possible)
OR
Card address(0001~1000) → Access Card
# → * (End)
# → * (End)
Key in the following digits
1234 → 1234 → # → 2 → # Insert 4 digit keycode password
[Note] Serial registration (If the first address will be [0100], next address is [0101] automatically increase.)
[Card registration] Card type : ISO 14443 (Mifare)
[Password registration]
indicator will appear and
the door key will be operating.
[WARNING & CAUTION]
If operator touch the key pad with a
gloved hand, it may cause malfunctioning.
Fragile Be careful not to expose it to falling.
[How to block external input]
password (4 digits) -> *
[Note] Disconnect the input of white line which is external
input. Door is opened and automatically released.
is blinking twice and
setting is completed.
Enter your password (4 digits),
and press the
Password (4 digits) →
Password (4 digits) → #
Pressing button,
mark blinks. Touching it, mark
pops up and it operates.
mark pops up, number
marks disappear, and the
Touch switch function is set.
Password (4 digits) →
Password (4 digits) → #
Pressing button, mark
blinks and the total numbers appear.
mark disappears and
Touch switch function releases.
Button
Button
*key.
Table of contents