!- The permitted limit values have been exceeded.
4. Safety regulations
By using the XCRiPad2/3/4, it is assumed that the user has observed the generally
applicable safety regulations and that he/she has read the EC Declaration of
Conformity to prevent any incorrect use of the device.!The following must be
observed without fail:
- It is prohibited to use a display protection film.
- The iPad2/3/4 should not be removed from the rubber casing. A broken
warranty label indicates that the intrinsic safety of the device is no longer
guaranteed.!
- The specially designed nylon case should not be removed in the Ex-area.!
- The iPad2/3/4 should not be charged in the Ex-area.
- It must be ensured that the device is not taken into, or used in, hazardous
areas classified as C1D1 or zone 0, 1 or 20, 21, 22.
- Do not submerge the XCRiPad2/3/4 under water.
- Do not use or unplug the headset port in hazardous areas.
Failure to observe these safety instructions will result in expiration of the C1D2 /
ATEX Zone 2 Intrinsic Safety rating.
5. Ex-data
Classification: Class I, Division 2, Group A-D T6
Classification: ATEX Zone2, Ex ic IIC T5 Gc
Approved for Zone 2, Intrinsic Safety (ic), explosion group IIC (explosive gases,
vapors or mist), temperature class T5.
!