XFARM xNode Soil User manual

GUIDA RAPIDA
ALL’INSTALLAZIONE
QUICK GUIDE
TO INSTALLATION
GUÍA RÁPIDA
DE INSTALACIÓN
xNode
Soil
Soil Pro
Multilevel
xCam
Leaf
ITALIANO
ENGLISH
ESPAÑOL
Tutorial
xfarm.ag/tutorial

2

3
Index
Indice
Índice
ENGLISH
ITALIANO
ESPAÑOL
xNode
xNode
xNode
xNode + Soil Pro
xNode + Soil Pro
xNode + Soil Pro
Sensor Installation Depths
Profondità di Installazione dei sensori
Profundidad de instalación del sensor
xNode + xLeaf
xNode + xLeaf
xNode + xLeaf
xNode installation
Installazione xNode
Fijación del xNode
xNode + SoilWatch 10
xNode + SoilWatch 10
xNode + SoilWatch 10
xNode + Multilevel Sentek
xNode + Multilevel Sentek
xNode + Multilevel Sentek
xNode + xCam
xNode + xCam
xNode + xCam
xNode conguration
Congurazione xNode
Conguración de xNode
4
16
28
18
30
19
31
20
32
21
33
33
21
7
9
10
22
34
14
26
38
6
8
9
11
23
35

4
It uses LoRa modulation on
868 Mhz frequencies and
requires xSense to function.
The range of xNode LoRa can vary between 500 to over 2000 m,
depending on the conditions in which it is installed and the type of xSense
used.
Maximum range is when xNode LoRa and xSense are in ‹sight› and there
are no obstacles between them.
xSense
Minimum
recommended
height: 1,5/2 m
Max 2000 m
xNode LoRa
To connect the sensors to xSense

5
It works on a cellular network
and can be used individually
and independently.
Each xNode Cellular contains a cellular module (2G, 3G, 4G) to send the data
collected by the sensors to the xFarm platform.
xNode Cellular
To connect the sensors independently
Minimum
recommended
height: 1,5/2 m
EN

6
In the case of xNode and SoilWatch 10 installation (surface or surface +
depth) follow the diagram for eld installation.
xNode + SoilWatch 10
Sensors and eld installation
SoilWatch 10 of surface
Installation xNode + SoilWatch 10
SoilWatch 10 surface + depth
SUP SUP
INF
xNode
SoilWatch 10
surface
Distance to
pole: 15 cm
Minimum 50 cm of
protection
Corrugated for sensor
recovery
Soil Soil
SoilWatch 10
depth
SUP
INF
Corrugated pipe to
protect cables from
animals

7
xNode + Soil Pro (Teros 10, Teros 12)
Sensors and eld installation
xSoil Pro of surface
Installation xNode + Soil Pro
xSoil Pro surface + depth
xNode
SoilWatch 10
surface
Distance to
pole: 15 cm
Minimum 50 cm of
protection
Corrugated for sensor
recovery
Soil Soil
SoilWatch 10
depth
SUP SUP INF
In the case of xNode and Soil Pro (Teros 10, Teros 12) installations (surface or
surface + depth) follow the diagram for eld installation.
SUPINF
Corrugated pipe to
protect cables from
animals
EN

8
Multilevel Sentek 30/60/90 cm
xNode + Multilevel Sentek
Sensors and eld installation
Installation xNode + Multilevel Sentek
In the case of xNode and Multilevel installation, follow the diagram for eld
installation.
7,5 - 15 cm
xNode
Soil Soil
Corrugated pipe to
protect cables from
animals

9
xNode + Multilevel Sentek
In the case of xNode installation with
xCam, simply attach it to the same pole
using the vertical bracket, choosing the
framing that best suits the crop.
After the rst switch-on of xNode, the
xCam will take a photo to determine the
correct framing.
Citrus
Pomegranate
Olive
Kiwi
Apple
Pear
Cherry
Peach
Plum
Grape
15 15 20
Maize
Tomato 10 10 1530
35
Crop Sensor
surface (cm)
Sensor
depth (cm)
Depth
(cm)
Depth
(cm)
Dual Sensor
[Underground/Exterior Irrigation]
Single Sensor
[External Irrigation]
Single Sensor
[Underground Irrigation]
xNode + xCam
Sensors and eld installation
Sensor Installation Depths

10
xNode + xLeaf
Sensors and eld installation
In case of xNode installation with xLeafs it
will be necessary to x it to the pole with
the bracket and clamps provided.
The sensor must be cleaned periodically using a cloth moistened with just
water.
If the sensor is used in extremely sunny areas with unusually high radiation
loads, the application of McNett UV protection is recommended.
To apply McNett UV Technology:
• Clean the sensor with water and a clean, soft cloth.
• Spray a soft cloth with UV Tech spray.
• Wipe both sides of the sensor surface with a damp cloth to apply
protection
xLeaf (foliar wetting sensor)
Cleaning and Maintenance
Install sensor and wire at a minimum of 1 metre from the ground with the tip
pointing North and the raised part upwards.

11
xNode + xLeaf Assembly and installation guide: eld conguration
Before xing xNode it will be necessary to place it in the xFarm App.
There are 2 ways to do this:
Or scan the QR code from your smartphone
Search for XFARM in the App Store or Google Play Store
METHOD 1 - QR Code
Scan the QR code on the back of the
device.
METHOD 2 - Serial Number
Enter the serial number found on the
back of the device manually in the
app.
Download the xFarm app to create your account and connect the
sensors

12
In the menu select Scan The camera will activate
and recognise the QR code
Complete all data and tap
Create Sensor
1) Scanning the QR code (recommended)
Step 1 Step 2
Step 3
xxxxxxxxxxxxxxxxxxxx
You can put the
location of the
sensor on the
map
Select the
type of sensor
connected to
xNode
Assembly and installation guide: eld conguration

13
In the menu select Sensors From the button select
New Sensor
2) Writing the Serial Number by hand
Step 1 Step 2
Step 3
Assembly and installation guide: eld conguration
Complete all data and tap
Create Sensor
You can put the
location of the
sensor on the
map
Select the
type of sensor
connected to
xNode

14
Fix the xNode at a height of no less
than 1.5 metres, above the crops and
with the photovoltaic panel facing
south.
Complete the installation by switching
on the xNode:
press the button on the side of the
device so that it remains pressed.
The LED light will remain on until it is
connected to the network, then it will
switch itself off.
If the connection fails, repeat the
operation by switching the xNode off
and on again after a few seconds.
Press once and
wait 2-3 seconds
for the LED to
start ashing.
OFF button
LED unlit
ON button
LED on
xNode Fixing and Commissioning
1,5 - 2,5 m
xNode
Assembly and installation guide: eld conguration
South

15

16
xNode LoRa
Per collegare i sensori a xSense
Usa la modulazione LoRa
su frequenze 868 Mhz e
necessita di xSense per poter
funzionare.
La portata di xNode LoRa può variare tra i 500 a oltre 2000 m, a seconda
delle condizioni in cui viene installato e dal tipo di xSense che si impiega.
La portata massima si ha quando xNode LoRa e xSense sono a “vista” e non
ci sono ostacoli tra di loro.
xSense
Altezza minima
consigliata:
1.5/2 m
Max 2000 m

17
Funziona su rete cellulare e può
essere usato singolarmente e in
modo indipendente.
Ogni xNode Cellular contiene un modulo cellulare (2G, 3G, 4G) per poter
inviare i dati raccolti dai sensori alla piattaforma xFarm
Altezza minima
consigliata:
1,5/2 m
xNode Cellular
Per collegare i sensori in modo indipendente
IT

18
In casi di installazione xNode e SoilWatch 10 (di supercie o
supercie + profondità) seguire lo schema per procedere all’installazione
in campo
xNode + SoilWatch 10
Sensori e installazione in campo
SoilWatch 10 di supercie
Installazione xNode + SoilWatch 10
SoilWatch 10 di supercie + profondità
SUP SUP
INF
xNode
SoilWatch 10 di
supercie
Distanza dal
palo: 15 cm
Minimo 50 cm di
protezione
Corrugato per recupero
sensore
Terreno Terreno
SoilWatch 10 di
profondità
SUP
INF
Tubo corrugato per
proteggere i cavi dagli
animali

19
xNode + Soil Pro (Teros 10, Teros 12)
Sensori e installazione in campo
xSoil Pro di supercie
Installazione xNode + Soil Pro
xSoil Pro di supercie + profomdità
xNode
Soil Pro di
supercie
Minimo 15 cm
dal palo
Minimo 50 cm di
protezione
Corrugato per recupero
sensore
Terreno Terreno
Soil Pro di
profondità
SUP SUP INF
In caso di installazione xNode e Soil Pro (Teros 10, Teros 12) (di supercie o
supercie + profondità) seguire lo schema per procedere all’installazione
in campo
SUPINF
Tubo corrugato per
proteggere i cavi dagli
animali
IT

20
Multilevel Sentek 30/60/90 cm
xNode + Multilevel Sentek
Sensori e installazione in campo
Installazione xNode + Multilevel Sentek
In caso di installazione xNode e Multilevel seguire lo schema per procedere
all’installazione in campo
7,5 - 15 cm
xNode
Terreno Terreno
Tubo corrugato per
proteggere i cavi dagli
animali
This manual suits for next models