XingKeChuang XKC-003K4 User manual

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
1/ 10
Pyroelectric Human Body Infrared Sensor Manual
XKC-003K4
table of Contents
1st. Overview.................................................................................................................................................................................... 2
2nd.Product Features ...................................................................................................................................................................... 2
3rd. Product Applications ............................................................................................................................................................... 2
4th.Technical Parameters................................................................................................................................................................ 3
5th. Product selection model........................................................................................................................................................... 3
6th. Installation method .................................................................................................................................................................. 4
7th. Product size and physical map................................................................................................................................................ 4
8th. Wiring instructions .................................................................................................................................................................. 6
9th. wiring diagramof various models.......................................................................................................................................... 7
10th. Installation and use instructions........................................................................................................................................... 8
11th.Product warranty terms and instructions ............................................................................................................................ 8
12th. Manual version..................................................................................................................................................................... 10
XKC-003K4-V1.6

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
2/ 10
1st. Overview
XKC-003K4 is an automatic control product based on infrared technology. It has high sensitivity, strong reliability, and
ultra-low voltage working mode. It is widely used in various automatic induction electrical equipment.
2nd.Product Features
1. Fully automatic sensing: when a person enters its sensing range, it outputs a high level, and when a person leaves the
sensing range, it automatically delays and closes the high level and outputs a low level.
2. Photosensitive control (optional, not set at the factory): photosensitive control can be set, no induction during the day
or when the light is strong.
3. Two trigger methods (selectable by jumper):
a. Non-repeatable trigger mode: After the high level is sensed, the output will automatically change from high to low after
the delay time is over.
b. Repeatable trigger mode: that is, after the sensing output is high, if there is a human body moving in its sensing range
during the delay period, its output will always remain high, and the delay will be high until the person leaves Change to
low level (the sensor module will automatically extend a delay period after detecting each activity of the human body and
use the time of the last activity as the starting point of the delay time);
4.With induction blocking time (default setting: within 1s): after each induction output (high level becomes low level), the
sensor module can set a blocking time period immediately, during which the sensor Does not accept any induction signal.
This function can realize the interval between "induction output time" and "blocking time", and can be applied to interval
detection products. At the same time, this function can effectively suppress various interferences generated during load
switching.
5.Wide working voltage range: the default working voltage is DC4.5V-20V.
6. Micro power consumption: quiescent current <200 microampere.
7. Output high and low level signal/NPN/relay output: it can be easily connected with various circuits.
8. The induction delay output time is adjustable (about 5-300 seconds), and the induction distance is adjustable (within 7
meters).
3rd. Product Applications
1. Human body induction lamps.
2. Human body induction toys.
3. Security products.
4. Industrial automation control,
5. Automatic induction electrical equipment.
6. Battery powered automatic control, etc.

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
3/ 10
4th.Technical Parameters
Operating voltage range
DC4.5-20V
Quiescent Current
<200uA
Output type
High and low level (high 3.3V/low 0V)/NPN/relay (normally
open/normally closed)/drive 2A LED
Trigger method
L can not be triggered repeatedly / H can be triggered repeatedly (default)
Delay time
Default 5S (5-300S adjustable)
Block time
The default is about 1S
Circuit board dimensions
32mm*24mm
Shell size
52L*36W*23H mm(Black), mounting holeΦ2.5
Lead wire length
≈28 cm
Sensing angle
<110 degree cone angle
Sensing distance
Within 7 meters
Operating temperature
-20~85℃
Sensing lens size
Diameter: 23mm (default)
5th. Product selection model
Serial
number
model
output signal
1
XKC-003K4-V
High and low level (high 3.3V/low 0V) output current
<3mA
2
XKC-003K4-N
NPN open collector output (normally open) load current
<300mA
3
XKC-003K4-M
Relay dry contact output (normally open) contact maximum
current 3A
4
XKC-003K4-MC
Relay dry contact output (normally closed) contact
maximum current 3A
5
XKC-003K4-LED2A
Can directly drive LED, drive maximum current 2A

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
4/ 10
6th. Installation method
(Wall installation icon)
(Ceiling installation icon)
7th. Product size and physical map
XKC-003K4-V
XKC-003K4-N
XKC-003K4-M
XKC-003K4-MC
XKC-003K4-LED2A
1. Note: Shell size 51.5mm(L)*52.6mm(W)*32.5mm(H) (The following is the size drawing of model
003K4-V/NPN/M/MC)

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
5/ 10
2. The following is the size drawing of model XKC-003K4-LED2A

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
6/ 10
8th. Wiring instructions
Adjust the distance potentiometer to rotate clockwise, the sensing distance is reduced (about 3 meters); on the contrary,
the sensing distance is increased (about 7 meters);
Adjust the delay potentiometer to rotate clockwise, the induction delay is shortened (about 5S); on the contrary, the
induction delay is extended (about 300S).

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
7/ 10
9th. wiring diagram of various models
1. Product
external
diagram
1. The negative pole of the black wire
power supply;
2.OUT yellow wire signal output;
3. Red wire power supply positive;
4.L can not trigger the port repeatedly;
H can trigger the port repeatedly;
5.CDS photoresistor;
6.Time delay adjustment;
7.Distances distance adjustment.
2. DC load
circuit
diagram
3. AC load
circuit
diagram
Relay normally open output (dry contact signal), that is, the relay is off when there is no induction, and the relay is
closed when there is induction.

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
8/ 10
The relay normally closed output (dry contact signal) means that the relay is closed when there is no induction, and the
relay is open when there is induction.
10th. Installation and use instructions
1. After the sensor is powered on, there is about one minute of initialization time, during which the module will output
0-3 times at intervals, and enter the normal standby state after one minute.
2. When installing, try to avoid interference sources such as lights directly on the lens on the surface of the module to
avoid introducing interference signals to cause misoperation; try to avoid flowing wind in the use environment, which
will also cause interference to the sensor.
3. Pay attention to the direction angle during installation, otherwise it will affect the sensing distance. The sensing
window of the sensor is as parallel as possible to the direction of the most human activity, so as to achieve a better sensing
effect.
4. When the ambient temperature rises close to the surface temperature of the human body during use (30-32°C), the
detection distance will be slightly shorter, which is a result of the influence of temperature factors.
11th.Product warranty terms and instructions
(A) .Warranty service
1. Warranty period maintenance: from the date of purchase, the product host has a one-year free warranty. The company
has the right to decide to repair or replace the faulty part. If it is replaced, the replacement part may be a new device or a

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
9/ 10
repair product of the same category, function, and quality. The replaced faulty part belongs to the company; the product
Resale and repair do not affect the warranty period. Products that have been repaired or replaced continue to enjoy the
original remaining warranty period service. If the warranty period is less than three months after the repair, the repaired or
replaced part shall be shipped from the date of delivery Warranty for three months; all products of the company are
guaranteed for repair.
2. Loss upon arrival (DOA) replacement: From the day of purchase, you can enjoy a free replacement service within 7
days. Products with the following problems are defined as DOA equipment: the packing and packing list do not match
after the first unpacking of the product; some or all of the components cannot be used normally after the first unpacking
of the product (surface scratches or other things that do not affect the function of the device) Defects are not included);
other hardware failures identified by our company’s engineers remotely or locally.
(B). Applicable limitations of warranty
For the following situations, the company does not assume warranty responsibility:
1. The product is out of warranty; the surface of the product is fragile and damaged; the appearance of the product is
seriously damaged, installation/use in abnormal environment, unauthorized disassembly and repair/modification, external
power supply damage and other abnormal damage;
2. Damage caused by incorrect installation and use of the product by the user not following the requirements of the
manual;
3. Damage caused by natural disasters and human negligence (fire, lightning, flooding, impact, etc.).
(C) .Accessories and consumables are not covered by the warranty.
(D) .Non-free warranty service
Within two years of product purchase, for non-warranty product (including components) failures and damages, you can
choose paid maintenance services (free labor costs), and we will charge the transportation cost of repairing parts and
accessories according to the actual situation.
(E). Ways to obtain warranty service
It is recommended that you contact the dealer who purchased this product to obtain the warranty service. For the
warranty, please present a valid warranty card (the dealer’s stamp is required to take effect) or the purchase
invoice/receipt: if you can’t show it, the product’s free warranty period 12 months from the product shipment date, and
the latest DOA application deadline is 7 days from the product shipment date.
(F). Statement
1. The copyright of this manual belongs to Shenzhen Xingkechuang Technology Co., Ltd. (Xingkechuang) and its
authorized licensors. Shenzhen Xingkechuang Technology Co., Ltd. (Xingkechuang) reserves all rights.
2. Without the written permission of the company, no unit or individual may excerpt or copy part or all of the contents of
this manual, and shall not spread it in any form.
3. The customer recognizes that the purpose of the design and production of the company's products does not involve use
in products related to life support or other systems or products used in other dangerous activities or environments.
Personal injury or death, property or environmental damage due to product failure (collectively referred to as high-risk
activities). The company's products are artificially used in high-risk activities, and the company does not guarantee it and
is not liable to customers or third parties.

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
10 / 10
4. Due to product version upgrades or other reasons, the contents of this manual may change. Xingkechuang reserves the
right to modify the contents of this manual without any notice or prompt. This manual is only used as a guide.
Xingkechuang makes every effort to provide accurate information in this manual. However, Xingkechuang does not
guarantee that the contents of the manual are completely free of errors. All statements, information and suggestions in this
manual do not constitute any express or Implied guarantee.
5. Not all models are available in all countries/regions.
Please keep this manual properly. Before using the product, please read this manual carefully. When using the product,
please be sure to operate in accordance with this manual. The company is not responsible for injuries and accidents
caused by operations that do not follow this manual.
(G).Environmental protection This product meets the design requirements for environmental protection.The storage, use
anddisposal should comply with relevant national laws and regulations.Seek to proceed.
12th. Manual version
Version
Release date
V16
September 28, 2020
Table of contents
Other XingKeChuang Security Sensor manuals
Popular Security Sensor manuals by other brands

Reer
Reer EOS2 Installation, use and maintenance

Schonstedt
Schonstedt XTpc Series instruction manual

theben HTC
theben HTC thePrema P360-101 UP WH user guide

SubSurface Instruments
SubSurface Instruments AquaTrac user manual

Chamberlain
Chamberlain Protector System manual

Bircher
Bircher TopScan G3 Translation of the original instructions