XP Metal Detectors DEUS II RC User manual

1
6.0
161 HZ6.0
84
76
Press MENU > DISCRI > EXPERT . Choose 2 Tones - 3 Tones - 4 Tones - 5 Tones.
Press EXPERT to access the MULTI TONES screen.
Customize the sound partitioning of the discrimination range. A volume level (0 to
10) and a sound frequency (comparatively low- or high-pitched) is assigned to each
part of the discrimination range.
Press to choose the Tone. With , select the TONE BREAK (T. BREAK)
or the VOLUME (VOL) and set it using + and - .
Tones - Threshold and tones settings
B.CAPS
4 TONES
TONES
DISCRI 90
NOTCH 1
T.ID G.ID
EXPERT
TONE 1
T.BREAK
V1.0 of the introduces some new features/modifications described below :
Volume of the low-pitched tone (tone 1) is the same as the Iron Volume.
04
7
VOL
With Full Tones, the ground area is audible from -6.4. The discrimination setting acts
as a “tone break,” and the Iron Volume setting adjusts the volume of ground and
ferrous below the discrimination level.
B.CAPS
TONES
DISCRI 9005
FULL
TONES
NOTCH 1
T.ID G.ID
Full tones
EXPERT
6.0
----6.0
60
35 From Full Tones > EXPERT .
Customize the sound partitioning of the discrimination range for Full Tones and Ad-
just volume levels of each tone independently.
Press to choose the Tone. With , select the TONE BREAK (T. BREAK)
or the VOLUME (VOL) and set it using + and - .
Full tones - Threshold and volume settings
TONE 1
T.BREAK
7
VOL
84
the OFFSET FT feature allows the user to shift the “Full Tone” audio frequencies of
targets with a signature just above the Discrimination threshold, in order to better
differentiate them audibly from iron.
0 = no offset 5 = (default value) creates a little offset
40 = all targets above discrimination will sound with the same high tone.
B.CAPS
OFFSET FT
DISCRI 9005
NOTCH 1
T.ID G.ID
Offset Full tones (Only with Full Tones mode ON)
EXPERT
5
THRESHOLD
MENU 90
2
T.ID G.ID The tone of the Threshold (and the deepest / smallest targets) can be modified from
150 to 603 Hz. Press EXPERT and adjust it with -or +.
Threshold (Only with Pitch mode ON)
DISCRI IAR
SENSITIVITY
I 0
I 95
EXPERT
RC V1.0

2
offers a wide choice of programs using different frequency configurations :
• Eleven simultaneous multi-frequency programs, each with different combinations of frequencies and
internal parameter settings (see chapter Programs for the specific features of each one). The maximum
frequency used by FMF programs can be configured by the user : 14 kHz - 24kHz or 40 kHz.
To help you better adapt to your soil and desired targets, the offers you the possibility to limit the
frequency band used from above. For example : You can configure your machine with 24kHz limit to be
less sensitive to very small conductors and more stable in difficult ground conditions. Selecting the 14kHz
limit can help focus on high conductors while reducing the crackling from some ferrous targets. Selecting
the 40kHz limit will remain the most versatile option because it selects the widest frequency range, which
will be more sensitive to a wider range of targets, non-ferrous targets close to ferrous and better perfor-
mance on some mineralized ground.
Frequency
FMF multi frequency programs
FREQ. MAX
SHIFT
MENU
78
T.ID G.ID
IRON VOLUME
REACTIVITY
I 3
I 2
90 Press -or + to select one of the 3 frequency limits.
If you are experiencing too much interference:
Press SHIFT then shift the frequencies and find the quietest band with -and
+or start an automatic scan by pressing SCAN .
40.0KHZ
Audio Filter
This function is to filter the audio and produce softer and more fluty sound, espe-
cially when target is at the detection limit. At depth the signal will be less scratchy.
In some situations, Audio Filter can gain a little extra depth.
On the beach: high levels like 2 to 4 can be combined with a low reactivity (0 to 1).
In land: lower levels like 1 or 2 are suggested to help recognize the short iron blips.
At 0: The Audio Filter is deactivated.
AUDIO FILT.
AUDIO
78
T.ID G.ID
90
AUDIO TYPE
EQUALIZER
1
Audio Type
HIGH SQUARE
The High Square sound has a richer and clearer harmonic compared to the standard Square, especially
on deep or small targets which are higher and more identifiable. When combined with the Pitch tone, the
strong targets near the coil are lower and softened compared to the standard Square tone.
This function turns on/off the visual target IDs for targets that fall below the discrimi-
nation setting, for example when FE TID is set OFF you only see the TIDs above the
discrimination adjustment even if you keep the Iron Volume ON.
Ferrous T.ID
GO TERRAIN
FE. T.ID
SETTINGS 90
T.ID G.ID
FREQ. SCAN
V1.0
ADDENDUM

3
Prg 1 Prg 2 Prg 3 Prg 4 Prg 5 Prg 6 Prg 7 Prg 8 Prg 9 Prg 10 Prg 11 Prg 12
MENU
Discri -6.4 to
99 10 6.8 6.8 6.8 9.0 9.0 6 .1 - - 8.0 8.0 8.0
1 tone
100 to
993
Hz/
VOL 0
to 10
202/7 202/7 -/7 - 100/7 202/7 202/7 - - 150/7 202/7 202/7
2 tones 717/10 518/10 -/10 - 518/10 717/10 518/10 - - 440/10 518/10 518/10
3 tones - 644/10 -/10 - 644/10 - 644/10 - - - 644/10 644/10
4 tones ---/10---------
5 tones ---/10---------
PITCH 150 to
603 Hz ---362--------
Full Tones ON
/OFF --ON---------
B.caps 0 to 5 0 0 0 0 2 0 - - - 0 0 0
Notch 1 OFF or
00-00
to
99-99
OFF 23-24 23-24 23-24 23-35 OFF OFF OFF OFF OFF OFF OFF
Notch 2 ------------
Notch 3 ------------
Discri IAR 0 to 5 - - - - - - - 0 0 - - -
Silencer 0 to 7 2 1 2 2 5 2 2 - - 2 2 2
Sensitivity 0 to 99 95 90 90 90 90 93 90 95 95 93 95 95
Salt Sens 1 to 9 9 9 7
FMF
Frequency
MAX
14 to
40 kHz 40 40 40 40 24 14 - 40 24 14 24 40
Mono
Frequency
4 to 45
kHz ------16.5-----
Iron
Volume 0to10777777777777
Reactivity 0 to 5 2 2.5 3 3 2.5 2 2.5 2 1 1 0 0
Audio
Response 0 to 7 4 4 4 4 4 4 4 3 5 5 5 5
Threshold 0 to 20 - - - 0 - - - 0 0 - - -
GROUND
Grab /
Manual
60
to 90 ------90-----
Tracking ON/OFF OFF
Ground
Stability 1 to 3 2 2 2 2 3 2 - - - - - -
Magnetic
ground
Accept
/
Reject
---------REJECT REJECT REJECT
Audio
Type
PWM/
SQUARE/
HIGH SQR
PWM PWM PWM SQUARE SQUARE PWM PWM SQUARE SQUARE SQUARE PWM PWM
PINPOINT ON
/OFF AT OFF
GO TERR. PUSH/
AUTO PUSH
FREQ
SCAN
MANUAL /
AUTO MANUAL
GENERAL
SENSITIVE
SENSI FT
FAST
PARK
DEEP HC
DEUS MONO
GOLD FIELD
RELIC
DIVING
BEACH
BEACH SENS
RC V1.0

4
CUSTOM PROGRAMS SPEC
Prg 13 Prg 14 Prg 15 Prg 16 Prg 17 Prg 18 Prg 19 Prg 20 Prg 21 Prg 22 Prg 23 Prg 24
Source
Prg 1 to 12
MENU
Discri -6.4 to
99
1 tone
100 to
993
Hz/
VOL 0
to 10
2 tones
3 tones
4 tones
5 tones
PITCH 150 to
603 Hz
Full Tones ON
/OFF
B.caps 0 to 5
Notch 1 OFF or
00-00
to
99-99
Notch 2
Notch 3
Discri IAR 0 to 5
Silencer 0 to 7
Sensitivity 0 to 99
Salt Sens 1 to 9
FMF
Frequency
MAX
14 to
40 kHz
Mono
Frequency
4 to 45
kHz
Iron
Volume 0 to 10
Reactivity 0 to 5
Audio
Response 0 to 7
Threshold 0 to 20
GROUND
Grab /
Manual
60
to 90
Tracking ON/OFF
Ground
Stability 1 to 3
Magnetic
ground
Accept /
Reject
AUDIO
TYPE
PWM/
SQUARE/
HIGH SQR
PINPOINT ON
/OFF
GO TERR. PUSH/
AUTO
FREQ
SCAN
MANUAL /
AUTO
__________
__________
__________
__________
__________
__________
__________
__________
__________
__________
__________
__________
V1.0
Table of contents
Popular Remote Control manuals by other brands

Conrad Electronic
Conrad Electronic 2832827 operating instructions

IMMAX
IMMAX NEO Smart remote v2 Zigbee 3.0 user manual

Sirena
Sirena TRILUX SB4 Application Instructions

SHENZHEN FLYING INDUSTRY DEVELOPMENT
SHENZHEN FLYING INDUSTRY DEVELOPMENT S1U-DC06 manual

Niles
Niles RCA-TT installation guide

Hama
Hama BRS1 operating instructions