XPOtool SK-9 User manual

Operation Manual
Pressure Switch for House Water Systems SK-9
50622
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

https://www.XPOtool.com Item 50622 Page 2
The Tool Experts
08 2022-1
The information contained in this document may alter at any time without previous notice. It is prohibited
to copy or spread any parts of this document in any way without prior written allowance. All rights re-
served.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.
Send an e-mail to:
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
To return orders for exchange, repair, or other purposes, please use the following address. Attention!
To allow for a smooth execution of your complaint or return, it is important to contact our customer
service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

https://www.XPOtool.com Item 50622 Page 3
The Tool Experts
08 2022-1
Introduction
Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients
take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.
Keep these operation instructions safe.
Safety regulations
•Always use an earthed power supply with the correct line voltage. The corresponding mains
voltage can be found on the nameplate. If you have any doubts as to whether the connection is
earthed, have it checked by a qualified specialist. Never use a defective power cord.
•Do not open this device in a damp or wet environment or when you are wet yourself and protect
it from direct sunlight.
•Install the device in a protected location so that no one can step on, fall over and/or damage
cables.
•Ensure that there is sufficient cooling by the ambient air and avoid heat build-up.
•Before cleaning this device, pull the power plug and only use a damp cloth for cleaning. Avoid
using cleaning agents and make sure that no liquid penetrates the device.
•There are no user serviceable parts inside this device. Leave maintenance, adjustment, and
repair to qualified specialists. In the case of external interference, the 2-year warranty period
expires! Keep these operating instructions in a safe place.
Technical data
Voltage (V)
220–240
Max. current (A)
10
Phases
1 (phase and neutral at the same time)
Max. operating pressure (㍴)
6
Pressure setting range (㍴)
1.4–4.1 (continuously adjustable)
Starting pressure setting range (㍴)
1.4–2.8 (continuously adjustable)
Connections (㎜)
13 (¼″) (internal thread)
Operation temperature (℃)
0–55
Colour
Black
Protection class
IP44 (splashproof)
If your pump has an output of more than 1.1 kW, you should connect a commercially available power
protection device or a corresponding power relay. With a 380 V power protection, 380 V/400 V three-
phase pumps can also be controlled.

https://www.XPOtool.com Item 50622 Page 4
The Tool Experts
08 2022-1
Max. pressure setting
Pressure range 1–5 bar
Factory setting
1.4–2.8 bar
Nominal current
16 A
Nominal voltage
230 V
Min. pressure setting
Setting
•Loosen the differential pressure nut (2).
•Set the switch-on pressure (1).
•Screw in the differential pressure nut (2) up to the switch-off pressure.
Dimensions and pieces
Switch-on pres-
sure (1)
Differential pressure (2)
Motor
Mains
Earth

https://www.XPOtool.com Item 50622 Page 5
The Tool Experts
08 2022-1
Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were imple-
mented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out
wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the
domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEE-
registration number DE45283704.
Disposal of used electrical and electronic appliances
(intended for use in the countries of the European Un-
ion and other European countries with a separate col-
lection system for these appliances).
The logo on the article or on its packaging points out
that this article must not be treated as normal house-
hold waste but must be disposed to a recycling collec-
tion point for electronic and electrical waste equipment.
By contributing to the correct disposal of this article you
protect the environment and the health of your fellow
men. Environment and health are threatened by inap-
propriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste
disposal facilities, or the store where you purchased the article.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction
manual require the written permission of WilTec Wildanger Technik GmbH.
This manual suits for next models
1
Table of contents
Other XPOtool Switch manuals
Popular Switch manuals by other brands

p5
p5 FutureNow FNIP-8x16A Installation and operation manual

Raritan
Raritan SwitchMan SW2-USB Quick installation and setup guide

Allied Telesis
Allied Telesis Rapier 48w Installation and safety guide

DOLD
DOLD NE 5020 operating instructions

SP Controls
SP Controls SP-SW5100-VUHD quick start guide

Speaka Professional
Speaka Professional 1082615 operating instructions

StarTech.com
StarTech.com StarView SV221DVIDD Instruction guide

Dataprobe
Dataprobe iBoot-G2 instructions

Graff
Graff E-9947 Instructions for assembly and use

Transition Networks
Transition Networks SM TAT4X Series quick start guide

QuietCool
QuietCool IT-AF-SMT owner's guide

SEKURYX
SEKURYX CK4-P208 quick start guide