XPower P-815I User manual

Model: P-815I
Cold-Air Rooftop Blower
Owner’s Manual
XPOWER Manufacture, Inc.
220 Clary Avenue
San Gabriel, CA 91776, USA
Tel: 626-285-3301, Fax: 626-285-3302
www.xpower.ws READ AND SAVE THESE INSTRUCTIONS


The XPOWER P-815I Cold Air Rooftop Blower is part of XPOWER Manufacturer's series of inflatable blowers.
XPOWER inflatable blowers are professional grade and multifunctional. With a internal sealed motor, the P-815I
blower is specially designed for weather proof indoor/outdoor uses.
Features:
• Low power draw with a high velocity air flow up to 3,600 CFM
• Quiet motor and lightweight.
• Easy carrying handle and stackable up to 3 units high.
• Easy and quick to disassemble for thorough cleaning and service.
• 20’ power cord length.
• Easy cord wrap on handle.
• Luggage handle and wheels available (optional) for easy mobility.
• Easy installation with included inflatable adapter.
• Durable and rugged housing.
• Weather proof Indoor/Outdoor use.
• 4 airflow positions (0°, 20°, 45°, 90°).
Inflatable blowers
can be stacked
(up to 3) on
their sides for
storage.
NOTICE:
Stacking feature
is not secure for
transportation.
45°
BLOWER
STORAGE

1. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
2. Complete Adapter Assembly (Fig. A)
3. Plug the electrical cord into the power outlet.
4. Carefully place the Inflatable Blower unit on a stable, flat dry surface.
5. Turn the switch to select desired speed, while making sure unit operates normally.
6. The inflatable blower in operation must be supervised at all times.
Durable and easy to operate with an effective balance of static pressure and airflow, the P-815I is suitable for
a variety of applications. As a multifunctional blower, the P-815I also functions to move air and to dry floors,
walls, furniture, etc.
Blower
Adapter
Fig.A
a) Aach Inflatable Adapter to Blower.
b) Tighten the screws on both sides of the Adapter to make sure
both Blower and Adapter are connected properly.

1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit
with wet hands or while standing in water.
2. To avoid risk of injury, do not direct air flow at face or any part of body.
3. To reduce the risk of fire or electric shock, do not use the Inflatable Blower with any solid-state
speed control device.
4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification
and / or install GFCI receptacle if necessary.
5. Do not operate any Inflatable Blower with a damaged cord or plug. Discard the unit or return it to an
authorized service facility for examination and/or repair.
6. Unplug the Inflatable Blower from the power supply before moving, servicing or cleaning.
7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or
similar coverings. Place the power cord away from traffic area to prevent tripping.
8. Do not allow children to play with or around an Inflatable Blower at any time.
9. Do not move or carry an Inflatable Blower while unit is operating.
10. All Inflatable Blowers in operation must be supervised at all times.

1) To keep the Inflatable Blower clean, use a damp cloth to wipe the surface of the housing; do not
immerse in liquid
2) When not in use, unplug and store the Inflatable Blower in a dry indoor place out of reach of children.
3) Always disconnect the Inflatable Blower from its source before performing any maintenance or cleaning.
Inflatable Blower
vibrates
Inflatable Blower
not running
Plug in the Inflatable Blower; check circuit breakerNo power input
Switch not turned on
Inflatable Blower fan wheel jammed
Intake or exhaust blocked
Accumulation of dirt on fan blades
Turn on switch
Remove material jamming fan wheel
Clean Inflatable Blower fan blades
Turn unit off and allow to cool,
then remove blockage

A set of Filters is available for the Inflatable Blower models which will help prevent small debris and
dust from entering the unit. To clean the filters: Remove the filters from the unit and wash with warm
soapy water, rinse with clean water and let dry thoroughly before reinstalling.
Filters (Optional)
Installation:
Filters snaps into the air inlets.
Note:
The filter I is for Motor Side,
The filter II is for Fan Side
Filter Removal:
Pull the filters off the unit.
Note:
After cleaning make sure the
filters are dry before
reinstalling.
Voltage / Frequency 115V / 60Hz Amps 8
Power 1 HP Rated Airflow (on high) 3600
Overheang Protecng Thermally Speeds one
Cord Length 20 Housing PP
Unit Weight 26.1 Lbs Unit Size 17.5" x 21" x 18.5"

XPOWER Limited Warranty (USA)
XPOWER’s Limited Warranty covers the unit (excludes POWER CORD) from defects in material
and crasmanship. The Warranty covers normal use for a term of one year from the original
date of purchase including parts, labor and one way shipping. Non-conguous states must pay
for roundtrip freight. A purchase receipt must be provided.
Important!
This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse,
disassembly, alteraon, corrosive chemicals, improper voltage, fire, flood, negligence,
accident, improperly or incorrectly performed maintenance or repair, or failure to perform
necessary maintenance or repair, or if the use of this product is not in compliance with the
instrucons and specificaons for its use
For Warranty service and parts replacement (US users only), you must:
A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorizaon) number.
B. Have original proof of purchase.
C. Use the original undamaged packaging or an industrial cerfied packaging method.
End user will be responsible to ship the unit (with RMA Number showing on the shipping
label) to the XPOWER Service Department. XPOWER to inspect, assess and advise the repairs
needed and the applicable cost, if any.
For users outside the US, please contact XPOWER Distributor in your country or region for
Warranty service and parts replacement.
Service

Parts List
Capacitor
1
3
5
7
9
11
13
15
2
6
8
10
12
14
15
16
16
Filters (optional) 16
Timer & Switch Plate
4-1
4-2
4-1 / 4-2 Switch Knob / Timer Knob
Sealed Motor

XPOWER Inflatable Blowers Series
Cold-Air Rooop
Blowers
Sky-Dancer
Blowers
High-Stac
Blowers
P-800I
P-830I
P-800HI
P-830HI
P-815I
BR-2C01A
BR-201A
BR-232A
BR-252A
BR-282A
BR-292A
BR-450
BR-450L
BR-460
BR-460L

Company Name / Contact Person / Title
State / Province Zip Country
Warranty Registration (for US user only)
For your product warranty, please complete and mail / fax this form to XPOWER MANUFACTURE, INC.
Address: 220 Clary Ave., San Gabriel, CA 91776. Tel: 626-285-3301 Fax: 626-285-3302
(For your convenience, register your product online at xpower.ws)


The XPOWER P-815I Cold Air Rooftop Blower is part of XPOWER Manufacturer's series of inflatable blowers.
XPOWER inflatable blowers are professional grade and multifunctional. With a internal sealed motor, the P-815I
blower is specially designed for weather proof indoor/outdoor uses.
Model: P-815I
Features:
• Low power draw with a high velocity air flow up to 3,600 CFM
• Quiet motor and lightweight.
• Easy carrying handle and stackable up to 3 units high.
• Easy and quick to disassemble for thorough cleaning and service.
• 20’ power cord length.
• Easy cord wrap on handle.
• Luggage handle and wheels available (optional) for easy mobility.
• Easy installation with included inflatable adapter.
• Durable and rugged housing.
• Weather proof Indoor/Outdoor use.
• 4 airflow positions (0°, 20°, 45°, 90°).
Inflatable blowers
can be stacked
(up to 3) on
their sides for
storage.
NOTICE:
Stacking feature
is not secure for
transportation.
45°
Cold-Air Rooftop Blower
BLOWER
STORAGE
Owner’s Manual
XPOWER Manufacture, Inc.
220 Clary Avenue
San Gabriel, CA 91776, USA
Tel: 626-285-3301, Fax: 626-285-3302
www.xpower.ws READ AND SAVE THESE INSTRUCTIONS

1. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
2. Complete Adapter Assembly (Fig. A)
3. Plug the electrical cord into the power outlet.
4. Carefully place the Inflatable Blower unit on a stable, flat dry surface.
5. Turn the switch to select desired speed, while making sure unit operates normally.
6. The inflatable blower in operation must be supervised at all times.
Durable and easy to operate with an effective balance of static pressure and airflow, the P-815I is suitable for
a variety of applications. As a multifunctional blower, the P-815I also functions to move air and to dry floors,
walls, furniture, etc.
Blower
Adapter
Fig.A
a) Aach Inflatable Adapter to Blower.
b) Tighten the screws on both sides of the Adapter to make sure
both Blower and Adapter are connected properly.

A set of Filters is available for the Inflatable Blower models which will help prevent small debris and
dust from entering the unit. To clean the filters: Remove the filters from the unit and wash with warm
soapy water, rinse with clean water and let dry thoroughly before reinstalling.
Filters (Optional)
Installation:
Filters snaps into the air inlets.
Note:
The filter I is for Motor Side,
The filter II is for Fan Side
Filter Removal:
Pull the filters off the unit.
Note:
After cleaning make sure the
filters are dry before
reinstalling.
1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit
with wet hands or while standing in water.
2. To avoid risk of injury, do not direct air flow at face or any part of body.
3. To reduce the risk of fire or electric shock, do not use the Inflatable Blower with any solid-state
speed control device.
4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification
and / or install GFCI receptacle if necessary.
5. Do not operate any Inflatable Blower with a damaged cord or plug. Discard the unit or return it to an
authorized service facility for examination and/or repair.
6. Unplug the Inflatable Blower from the power supply before moving, servicing or cleaning.
7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or
similar coverings. Place the power cord away from traffic area to prevent tripping.
8. Do not allow children to play with or around an Inflatable Blower at any time.
9. Do not move or carry an Inflatable Blower while unit is operating.
10. All Inflatable Blowers in operation must be supervised at all times.
Voltage / Frequency 115V / 60Hz Amps 8
Power 1 HP Rated Airflow (on high) 3600
Overheang Protecng Thermally Speeds one
Cord Length 20 Housing PP
Unit Weight 26.1 Lbs Unit Size 17.5" x 21" x 18.5"

1) To keep the Inflatable Blower clean, use a damp cloth to wipe the surface of the housing; do not
immerse in liquid
2) When not in use, unplug and store the Inflatable Blower in a dry indoor place out of reach of children.
3) Always disconnect the Inflatable Blower from its source before performing any maintenance or cleaning.
Inflatable Blower
vibrates
Inflatable Blower
not running
Plug in the Inflatable Blower; check circuit breakerNo power input
Switch not turned on
Inflatable Blower fan wheel jammed
Intake or exhaust blocked
Accumulation of dirt on fan blades
Turn on switch
Remove material jamming fan wheel
Clean Inflatable Blower fan blades
Turn unit off and allow to cool,
then remove blockage
XPOWER Limited Warranty (USA)
XPOWER’s Limited Warranty covers the unit (excludes POWER CORD) from defects in material
and crasmanship. The Warranty covers normal use for a term of one year from the original
date of purchase including parts, labor and one way shipping. Non-conguous states must pay
for roundtrip freight. A purchase receipt must be provided.
Important!
This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse,
disassembly, alteraon, corrosive chemicals, improper voltage, fire, flood, negligence,
accident, improperly or incorrectly performed maintenance or repair, or failure to perform
necessary maintenance or repair, or if the use of this product is not in compliance with the
instrucons and specificaons for its use
For Warranty service and parts replacement (US users only), you must:
A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorizaon) number.
B. Have original proof of purchase.
C. Use the original undamaged packaging or an industrial cerfied packaging method.
End user will be responsible to ship the unit (with RMA Number showing on the shipping
label) to the XPOWER Service Department. XPOWER to inspect, assess and advise the repairs
needed and the applicable cost, if any.
For users outside the US, please contact XPOWER Distributor in your country or region for
Warranty service and parts replacement.
Service

Parts List
Capacitor
1
3
5
7
9
11
13
15
2
6
8
10
12
14
15
16
16
Filters (optional) 16
Timer & Switch Plate
4-1
4-2
4-1 / 4-2 Switch Knob / Timer Knob
Sealed Motor
Company Name / Contact Person / Title
State / Province Zip Country
Warranty Registration (for US user only)
For your product warranty, please complete and mail / fax this form to XPOWER MANUFACTURE, INC.
Address: 220 Clary Ave., San Gabriel, CA 91776. Tel: 626-285-3301 Fax: 626-285-3302
(For your convenience, register your product online at xpower.ws)

XPOWER Inflatable Blowers Series
Cold-Air Rooop
Blowers
Sky-Dancer
Blowers
High-Stac
Blowers
P-800I
P-830I
P-800HI
P-830HI
P-815I
BR-2C01A
BR-201A
BR-232A
BR-252A
BR-282A
BR-292A
BR-450
BR-450L
BR-460
BR-460L
Table of contents
Other XPower Blower manuals

XPower
XPower BR-430 Series User manual

XPower
XPower P-800I User manual

XPower
XPower BR-18LZ User manual

XPower
XPower X-600 User manual

XPower
XPower P-200T User manual

XPower
XPower P-250AT User manual

XPower
XPower P-200AT User manual

XPower
XPower BR-450 Series User manual

XPower
XPower BR-272A User manual

XPower
XPower PL-700A User manual