Yaesu GS-232B User manual

~~YAESU
GS-232B
Computer Control Interface
for
Antenna
Rotators
YAESU
COMPU
I
EM
CONTROLLER
GS-232B
o
POWER
=1
.0.0
VERTEX STANDARD CO., LTO.
4-8-8 Nakameguro. Meguro·Ku
Tokyo
153---8644,
Japan
VERTEX STANDARO
us
Headquarters
10900
Walker
SHeet. Cypress,
CA
90630,
USA.
YAESU EUROPE B.V.
PO. Box 75525. 1118
ZN
SChlphol
The
Netherlands
YAESU
UK
LTO.
Unit 12, Sun Valley Business Park, Wmnall Close
Winchester, Hampshire.
8023
OLB,
U.K.
VERTEX STANDARD HK LTD.
Unit
5,
20/F., Seaview Centre, 139·141
HOI
Bun Road.
Kwun Tong Kowloon, Hong Kong

ill
ill
ill
Fl
...
I"l
....
~
...
-•
____
'''f!!!!!:
jL1
"-
-
Ij---:ii
I
:_
£.11
111
0..-.
-
"----~.
£ -
:-
ill
.-
...
H
ill
-
iliiiiii;;=
-.'

GS-232B Computer Control Interface
for
Yaesu
Antenna
Rotators
The
GS-232B
provide digital control
of
most models
of
Yaesu
antenna
rotators"
frolll
the
serial
port
of
an
external
personal
computer.
The
GS-2328
contains its
O\\ln
microprocessor
with
a
to-
bit
analog-to-digital (A-D) converter
and
EEPROM. The
async
serial line
can
be
configured
for
serial
data
rates
from
1200
to
9600 baud. The
GS-232B
has
aD8-9 "male" con-
nector
for
connection
to
the (RS-232 )
COM
port
of
your
computer.
Purchase
or
construct
a
"straight"
type
serial
cable.
ensuring
it
has
the
correct gender
and
number
of
pins for
connection
to
your
system.
Firmware
on
(he
G5-2328
SUppOr1S either direct keyboard
control,
or
commands
frol11
programs written specifically
10
support
it
(software
is
not
supplied
by
Yaesu).
In
addi-
lion
to
reading
and
setting
antenna
angle
and
rotation
speed,
the
firmware
includes
clocked
positioning
routines
(0
auto-
matically
step
the
antenna
through
up
to
3800
angles
at
pro-
grammable
intervals,
such
as
for
tracking
band
openings
or
satellites
(with
an
elevation
rotator).
Please read this lIlanual carefully
to
install the
GS-232B.
Ifalso installing aG-400,
G-SOOA
or
G-SSO
with
the
GX-
500
Automatic Control Adapter, follow
the
procedures
in
the
GX-SOO
manual before installing the
GS-232B.
x
G-800DXA/G-1
000DXAlG-2800DXA
Azillluth
Rotator.
G-800DXC/G-1000DXC/G-2800DXC
Azillluth
Rotator.
G-400
Azimuth
Rotator.
G-SOOA/G·SSO
Elelation
Rotator.
G-S400B/G-S600B/G-SSOO
A7-El
Rotator.
and
ahmc
A/imuth
and
Elc\ation
rotator
combination.
G-400
Azimuth
Rotator
and
G-SOOA/G-SSO
Ele\
ation
Rota-
tor
requires
olle
GX-500
Automatic
Control
Adapter
each.
1

en
Z
o
-
~
u
-
...
-
U
Lol
C-
OO
2
GE
ERAL
Po\\cr Requirements: DC
12
V.
70
mA
Case
Size: 4.3" (W) x0.8'"
(H),
5.4"
(D)
(110x21
x
138
mill)
Weight (approx.): 13.4 oz. (380 g)
Semiconductors
M
ieroproeessor:
PIC 18C452
(includes
10
bits
AD
eomener)
EEPROM:
24LC256
Serial Comms: RS-232C
voltage
le\'els.
1200 to 9600 baud, 8data bits,
1stop bit, no parity
Overnow
ConI.: Hardware Control (CTS
pan)
CONNECTOR
PINOUT
Serial
I/O:
9-pin DB-9 connector
(RS-232C
connector)
Pin
2 - 1xData
Pin
3 -
Rx
Data
Pin
5 -
Signal
Ground
Pin
7 - Rl S
Pin 8- T
Rotator
Control:
5-pin
connector
(El
connector)
Pin I -
UP
switch (open collector)
Pin 2-DOW switch (open collector)
Pin
3 - analog output (0.5 -4.5
V.
four steps)
Pin 4 - analog input (0-5V elevation)
Pin 5-analog ground
5-pin
connector
(AZ.
connector)
Pin 1- RIGHT
s"itch
(open collector)
Pin 2-LEFT switch (open collector)
Pin
3 - analog output (0.5 -4.5
V.
four steps)
Pin 4-analog input (0-5V azimuth)
Pin
5 -
analog
ground

SUPPLIED
ACCE
SORIES
oControl
cable
for
the
Azimulh
Rotator
X1
I
pc
("'5-pil1" -
"Mill-DIN"
cablc)
oControl
cable
for
the
AziEL
Rotator
x
:!
_I
pc
("'DlIal 5-pil1" -
"DIN"
cable)
o
DC
cable
w/coaxial plug I
pc
ollook &
loop
fasteners
(for mounting) I
pc
xI: G-800DXA. G-1000DXA. G-2800DXA,
G-800DXC, G-1000DXC,
al1d
G-2800DXC
X2: G-5400B, G-5600B,
and
G-5500
AVAILABLE
OPTIONS
GX-500
COl1trol
Adaplcr
(Check wilh
YOllr
dealer)
C-1000
COl1l1ecliol1
Cable
(for SOX
series
Azuirnuth
Rotator)
NC-72B/C/F/U"
AC
Ada
pier
x3:
"B"
suffix
is
for
use
wilh
117
VAC,
"C"
suffix
is
for
lise
with 220-240
VAC,
"F"
suJJix
is
for
lise
willl 220 VAC, or
"U"
suffix
is
for
use
with 230 VAC
3

During installation. a
personal
computer
\\ilh
a
serial
POfl
and
terminal
software
is
required
to
calibrate
trimmers
on
the
COlltroller
and
on
the
Control
Intcrf..,cc.
An) simple
in-
teractive terminal
program
can
be
used
-
it
anI)
has
to
trans-
mit
keystrokes
as
lyped,
and
display
characters
received
from
the GS-232B.
POWER
&
CONTROL
CONNECTIONS
DXA
01'
DXC Series Azimuth
Rotator
oConnect Ihe supplied DC cable
10
asource
of
12
VDC.
The
red lead
connccts
10 the Posilive
(+)
DC
terminal.
and
the
black
lead
conneCls
10
the
egalive
(-)
DC terminal. The GS-232B requires
70
mAo
The
supplied
cable has a
SOO-mA
fasl-blow fuse. Use only
the
same
Iype
fuse
for
replacemenl.
o
Plug
the
coaxial
power
connector
into
the
DC
12V
jack
on Ihe GS-232B rear panel.
oConnect the supplied Control cable ("S-pin" -
"Mini,
DIN")
belween the EXT CONTROL
connector
on
Ihe
rOlalor's
controller
and
AZ
connector
all
the
renr
panel
of
the GS-232B (Figure I).
4
•
•i
j"
5
•
..
•0[
..
>
:!
..
~
~
l?-
I?-
~
~
Figure 1
OXA
or
DXC
series
';' Azimuth
Rotator
60:> o
00
0 0
~r
.!
~"'i'!.-:
~~
.",.-
-~l·
10
ii3qf-.--
[[5
r

I)OWER
&
CONTIWL
CONNECTIONS
5
Figure
3
jGX·500
",l,tlE'.
~mi~~fiT
To
EI
.....
lIlion
(
..•.•..
Controll.,
G-tOO/G-SOO
or
G-tOO/G-550
&air of
GX-SOO
Connect
Ihe
supphed
DC
cable
10
asource
of
12
VDC.
The red lead connects to the Positi\e (+)
DC
temtinal,
and
the
black
lead
connects
to
the
Negative
( ) D lerminal. The
GS-232B
requires
70
mAo
The
supplied cable has a
SOO-mA
fasl-blow fuse. Use
only
the
same
t)
pc
fuse
for
replacement.
Plug the coaxial poll'er connector into the DC 12V
jac~
on the
GS·232B
rear panel.
Connect the S-pin to S-pin cable (supplied \\ith
Ihe
GX·
500;
req""es
1"0
sets) belween the GX-500(s) and
GS-
232B
(Figure 3).
Figure 2
G-S"OOB/-S600B Az-El. Rotator
Connect the supplied DC cable
to
asource
of
12
VDC.
The red lead connects to
Ihe
Positive (+) DC lenninal.
and
the
blach
lead
connects
to
the
\Jegalivc
( ) DC terminal. The
GS-232B
requires 70 mA. 1
he
supplied cable has a
SOO-mA
fast-blow
fu
e.
Use onl)
the
same
t)
pc
fuse
for
replacement.
Plug the coaxial po\\er connector into
the
DC
12V
jack
on the
GS-232B
rear panel.
Connect the supplied Control cable ("Dual S-pin" -
"DI
")
bel\\een Ihe rotator's comroller and
GS-232B.
Be careful to malch the "AZ." and
'"EL"
labels
on
Ihe
cable
II'
ilh
the same labels
on
the rear panel
oflhe
GS-232B
(Figure 2).

POWER
&
CONTROL
CONNECTIONS
SDX Series Azimuth Rotator
oPrepare Ihe optional
C-1000
Connection Cable.
Remme
the
Top
Cover
from
the
controller.
oConnect
the
8-pin
connector orthe C-1000 Connection
cable
to
the
exposed
8-pin
connector
located
the
rear
left
corner
in
the
controlk:r.
o
Route
the
5-pin connector
or
the
C-1000
ollnection
cable
through
Qut
the
rubber
grommet
on
the
rear
panel
of
the controller.
and
connect
illO
the
AZ.
connector
011
the rear panel
of
the GS-232B (Figure
4).
oReplace the fop
Cmer.
ConnCCllhe
supplied
DC
cable
to
a
source
of
12
VDC.
The
red
lead
connects
to
the
Positive
(+)
DC
terminal.
and the
blac"
lead connects
10
the
cgati\c
( ) DC terminal
The
GS-232B requires
70
mAo
1he
;upplied
cable has a500-mA fast-blo\\ fllse.
Usc
onl)
the
sal1l~
')epe
fuse
for
replacement.
oPlug theconxial po\\ereOnneclOr into the DC 12V
jac~
on
the GS-232B rear panel.
Optional C-1000 Connection Cable
Output GrOmmtl ,~
C·1OOO
Conn.cllon
C.ble
Figure
4
ellposed
a_pin
Confle<:tOf
l~de
of
I~
Conlroller)
SOX series
Azimuth Rotator
6

COMPUTER
CONNECTION
With the
compuler
swilched
off, connect lhe DSUB-9
pin
Straighl
R
-232C
cable
10 lhe serial
P0rl
of
your
computer. lhen connect
the
olher
end
of
lhe
R-232C
cable
to the
RS-232C
connector
on the
rear
panel
of
lhe
GS-232B.
o
Tum
the
computer's power switch
on,
then
tum
the
GS-
232B's
pOller swilCh on.
Within
15
seconds
ofs\\ilhing
lhe
GS-232B's
po"er.
press the I
Jl
(Ef>lT"ER)
key several times to adjuslthe
GS-
232B's
data baud rate to the
Computers
data baud rate
Irthe
computer
is
su
ccs~lIl
to
selling
the
data
baud
rate.
the
computer's diaplay
will
hO\\ "Connect OK:'
Ifyou are usinga
G-400Azimuth
ROlator,
orG-5400BI
G-5600B
AL-EL
Rotator, press IP361 -
[Jl
(P, 3, 6,
and
Ef>lT"ER)
on the eomputer keyboard to disable the
450
0
rOlation eapabilily
of
the
GS-232B.
To reslore
450
0ro-
lalion eapability, press
IP45)
-
[Jl
(P,
4, 5. and
Ef>IT"ER)
on lhe eomputer keyboard.
7

DXNDXC/SDX
SERIES
AZIM
TIl ROTATOR
z
o
-
~
Cl:l
~
U
Azimuth Offset ull
oFrom the Controller panel. sel lhe Rotator fully counter-
clock\\ise
(sella
0
).
oPres
[0]
-
[.1l
(Ihe letter
"oh.'·
and
"ENTER')
on Ihe
computer keyboard 10 activate the azimuth calibration
routine. The computer display should show
"are
you
sure?"
Press
IYI
-
[.11
(',y"
and
"ENTER')
on Ihe computer
"ej·
board. 1he compulerdisplay should sho\\ "Completed."
and
sa\e
the calibration data and exit
the
azimuth cali-
bration routine.
Azimuth A-D Calibration
:J From the Controller panel. el the ROlalor fully c1ock-
\\ ise (10 lhe righl).
:J Press
[F]
-
l.1l
("F"
and
"ENTER")
onlhe
computer
ke)-
board to activate the Control Interface's azimuth A-D
converter calibration
rOlltine.
The computer's display
should show
"AZ=S80:'
where
"88B"
is athree-digit
number which indicates
the
azimuth heading
in
degrees.
:J Adjust lhe OUT
VOL
ADJ
potenliomeler on onlrol-
ler rear panel
so
as
to gel areading
of
"450"
on
the
computer's displa). This reading ("450 degrees") cor-
responds to the actual beam heading you established
\\hen
)Oll
pointed the azimuth rotator
to
the East.
:J Press
l.1l
("ENTER") on lhe
compuler
keyboard
to
exit
the
azimuth
A-D
convcr1cr calibration routine.
8
Imprtant
Note!
If)our
controller's indicator needle start')
from
apoint other than 0 (
011h)
(such
<Iii
the
defaLlh
setting
of
the
USA
version). align the slarting point
of
the controller's indicator needle
100
(North) before calibration.
When finish the calibration, set the controller's indicator needle to
the
desired point. Refer
to
lhc rotator's
u\cr
manual for details regarding the indicator needle alignment

G-400
AZIMUTI-I
ROTATOR
Azimuth
Offset
Null
o
From
the
Controller
panel.
sct
lhe
Rotator
fully
countcr-
clock\\ ise
(get
to
0°).
oPress
[0]
-
[..II
(I
he letler
"oh:'
and
"ENTER")
on the
computer
keyboard
to
activate
the
azimuth
calibration
routine.
The
computer
display
shollid
show
"are
you
sure?"
oPress
[Vj
-
f.J]
("V" and
"ENTER")
on the computer
key-
board. The computer displa, should show
''Completed:'
and
save
(he
calibration
data
and
exit
the
azimuth
cali-
bration
routine.
Azimuth
A-D
Calibration
oFrom
the
Controller panel.
set
the
Rotator fully clock-
wise
(to
the
right).
oPress
[F
J-
[..I]
("F" and
"ENTER")
on
the computer key-
board
to
activate
the
Control Interface's
azimuth
A-D
converter
calibration rOlltine.
The
computer's display
should
show
"AZ=aaa."
where
"088"
is
athree-digit
number
which
indicates
the
azimuth
heading
in
degrees.
oAdjust the FULL
SCALE
ADJ
on the
GX-500
so as
to
gel
a
reading
of"180"
on
the
computer's
display.
This
reading
("180
degrees")
corTcsponds
to
the
actual
beam
ht:ading
)Oll
eSlablished
when
yOll
pointcd
the
azimuth
rolator
(0
the
Soulh
(the
fully
clockwise
seuing).
Press
[JI
("ENTER")
on the computer keyboard
to
exit
the
azimuth
A-I)
convener calibration routine.
9

G-5400B/-5600B Az-EL
ROTATOR
z
o
-
~
CQ
-
...J
<
U
10
Azimuth
Offset
~ull
o
From
the
Controller
panel,
set
the
Rotator
full)
counter-
clockwise (set
to
0°).
DPress
[OJ
-
l.JJ
(the leller
"oh:'
and
"ENTER")
on
the
computer "cyboard
to
activate
the
azimuth
calibration
routine.
The
cam
pUler
display
should
sho\\
"are
you
sure?"
DPress
[V]
-
[.JJ
("'Y"
and
"ENTER")
on the computer ke}-
board. The computerdispla) should show"Completed:'
and
save
the
calibration
data
and
c\it
the
azimuth
cali-
bration routine.
Azimuth
A-D
Calibration
o
From
the
Controller
panel,
set
the
AL.il11uth
ROlator
full)
c1ocl,\\ ise (to the right).
Press
[F]
-
l.JJ
("F"
and
"ENTER")
on the cornputer key-
board
to
activate
the
Control
Interface's
a7imuth
A-D
con\crter calibration
routine.
The computer's displa)
should
sho'\-
"AZ=ooa:' \\here "oaa" is athree-digit
number
\\
hich
indicates
the
azimuth
heading
in
degrees.
DAdjust the
OUT
VOL ADJ potentiometer
on
the "Azt-
MUTH"
(leO) side
of
the Controller rear panel
so
as
to
get
a
reading
or"180" olllhe
computer's
displa~.
This
read·
ing
("180
degrees")
corresponds
to
the
actual
beam
head-
ing)
au
established
\\hen
)OU
pointed
the
a7imuth
rota-
tor
to
the
outll.
DPress
[.JJ
("ENTER") on the computer
~e}
board to
e,it
the
alillluth A-D comerter calibration routine.

G-S400B/-S600B Az-EL
ROTATOR
Elevation Offset Null
From
the
Controller
panel.
set
the
L1cvation
Rotator
to
the "Ien-' horizon (do\\n. set
to
0
).
oPress
[021
-
[JI
(Ihe leiter
"oh:'
"2:'
and
"ENTER")
on
the
computer
keyboard
to
activate
the
elevation
calibra-
tion
routine.
The
computer
display
should
show
"are
you
sure?"
oPress
[Y]-
[JI
(
..
y"
and
"ENTER")
on the computer
~e)
board. The computerdispla) should sho\\ "Completed:'
and
sme
lhe
calibration
data
and
e\it
the
ele\ation
cali-
bration
rOluine.
Elevation A-D
Calibration
o
From
the
Controller
panel.
set
the
Elc\ation
Rotator
to
full
scale (180 :"right" horizon).
oPress
[F2j
-
[JJ
(F.
2.
and
ENTER)
on the computer key-
board
to
activate
the
Control
Interface's
elevation
A-D
converter
calibration
routine.
The
computer
will
display
"AZ=888EL=eee,"
where
"eee"
is
athree-digit
num-
ber
\\
hich
indicates
the
elevation
heading
in
degrees.
For
the
purposes
Oflhis alignment,
you
may
ignore
the
(azimuth)
"88a"
numbers.
Adjust the OUT VOL
ADJ
potentiometer
on
the
"El-
EVATION"
(right) side
of
the Controller rear panel so as to
get
a
reading
0["180"
on
the
computer's
display.
This
reading
("180 degrees")
corresponds
to
the
actual
beam
heading
you
established
when
you
pointed
the
elevation
rotator
10
the
180
0
position.
oPress
[JI
("'ENTER")
on
the
computer keyboard
10
exit
the
elevation
A-D
converter
calibration
routine.
;z
o
-
~
Cl:i
-
....:l
<
U
lJ

C-5500 Az-EL
ROTATOR
z
o
-
~
Cl:i
-
.....:l
<t:
U
12
Azimuth
Offset lull
o
From
the
Controller
panel.
set
the
Rotator
full)
counter-
clockwise (se,
'0
0°).
Press
101
-
l.J]
('he letter ··oh." and "EmER") on
'he
computer
keyboard
to
activate
the
azimuth
calibration
routine.
The
computer
display
ShOlIId
show
"are
you
sure?"
oPress
Iy]
-IJI
(Hy"
and "EmER") on 'he compUler key-
board. The computerdispla)' should
sholV
"Completed,"
and
save
the
calibration
data
and
exit
the
azimuth
cali-
bration routine.
Azimuth A-D
Calibration
oFrom
the
Controller panel.
sel
the
Azimuth Rotator fully
clockwise
(to
the
right).
oPress
IF]
-
1..11
(F and ENTER) on
'he
computer
ke)-
board
10
activate
the
Control
Interface's
azimuth
A-D
converter
calibration
rOlltine.
The
computer's
display
should
show
"AZ=aBB," \\herc
"8Ba"
is
athree-digit
number
which
ind
icates
the
azimuth
heading
in
degrees.
oAdjus, the
OUT
VOL ADJ potentiometer on the
"AZI-
MUTH"
(left)
side
of
the
Controller
rear
panel
so
as
to
get
a
reading
of"450"
on
the
computer's
display.
This
read-
ing
("450:
360 degrees +
90
degrees") corresponds
to
the
actual
beam
heading
you
established
when
you
pointed
the
azimuth
rolatar
fully
clockwise,
oPress
1..11
("EmER") on the compu,er keyboard
'0
exit
the
azimuth
A-D
converter
calibration
rOlltine.

G-5500 Az-EL
ROTATOR
Elevation Offset Null
o
Press
[02]
-[JI (the leiter
"oh,"
"2," and "ENTER")
on
the
computer
keyboard
to
activate
the
elevation
calibra-
tion
routine.
The
computer
display
should
show
"are
you
sure?"
o
Press
[YI
-lJJ
("Y"
and
"ENTER")
on
Ihe
compuler key-
board. The computer display should show "Completed,"
and
save
the
calibration
data
and
exillhe
elevation
cali-
bration
rOlltine.
Elevation
A-D
Calibration
o
From
the
Controller
panel,
set
the
Elevation
Rotator
to
full
seal
(180 :
"right"
horizon).
o
Press
[F2]
-[JJ
(F,
2,
and
ENlffi)
on
the computer key-
board
to
activate
the
Control
Interface's
elevation
A-D
converter
calibration
routine.
The
computer
will
display
"AZ=aaaEL=eee,"
where."eee"
is
athree-digit
num-
ber
which
indicates
the
elevation
heading
in
degrees.
For
the
purposes
of
this
alignment,
you
may
ignore
the
(azimuth)"
aaa" numbers.
oAdjust the
OUT
VOL
ADJ
potentiometer
on
the
"EL-
EVATION" (right) side
oflhe
Controller rear panel
so
as
10
gel
a
reading
0["180"
on
the
computer's
display.
This
reading ("180 degrees") corresponds to the actual
beam
heading
you
established
when
you
pointed
the
elevation
rDlalor
to
the
180
0
position.
o
Press
IJI ("ENTER")
on
the
compUler keyboard 10 exit
the
elevation
A-D
converter calibration routine.
I:

G-SOO
ELEVATION
ROTATOR
/4
Elcvation Offsct Null
aPress
[02]
-
[-ll
(the letter
"oh:'
"2,"
and
"ENTER")
on
the computer kc) board to activate the elC\3tion calibra-
tion rOlltine. The computer display should show
"are
you
sure?"
aPress
[YI
-
[-ll
("Y" and
"ENTER")
on
the computer
key-
board. The computerdisplay should show "Completed,"
and
save Ihe calibration data and exit the elevation cali-
bration routine.
Elcvation A-D
Calibration
oFrom the ontroller panel, sct the Elevat
ion
Rotator
to
full
scale (180°: "right" horizon).
oPress [F2] -
[-l]
(F,
2,
and
ENTER)
on
the computer
key-
board to activate the
Controllnlerfacc's
elevation
A-D
converter calibration routine. The computer
will
display
"AZ=888EL=eee," where
"eee"
is
athree-digit nUI11-
ber which indicates the elevation heading
in
degree.
For
the
purposes
of
this alignment, you
l11a~
ignore
the
(azimuth)
"B88"
nLllllbers.
oAdjust the OUT VOL
ADJ
potentiometer on the GX-
500
so as
to
gel areading
of"180"
on the computer's
display. This reading ("180 degrees") corresponds 10
the
actual beam heading you established when
yOll
pointed
the
elevation rotator
to
the
180
0position.
oPress
l-lJ
{"ENTER")
on the computer keyboard
to
exit
the elevation
A-D
converter calibration routine.
z
C
-
!-
<l
0:
a:
-

z
o
~
~
0..
o
GE
If)
Oll
\\
ish,
you
can
mOllnt the
GS-232B
on
lap
of
your
Ro!ntor Controller
lIsing
the
1\\'0 supplied hook-and-Ioop
r~sleller
strips. Just remove
the::
backing from one side
of
e<lch
strip. and press into place
on
the
bottom
of
the
GS-
2328.
Then remove the backing frollllhe other side. and
press the
GS-232B
into place on
the
Controller.
ERAL
After installation and calibration. the Control Interface can
accept
cOl11mands
entered directly
from
the keyboard,
or
from
aprogram writlcn specifically
10
sllpport
it
(not sup-
plied
by
Yaesu).
For briefslIllllll<lries
or
the
cOll1mands
rec-
ognized b)
Ihe
Conlrollnterface, press
IHj-
[..II
for alist
ofazilllllih commands. or IH2J -[JI for elevations
COI11-
mands. Keep
in
mind Ihat all cOlllmands require that the
ENTER
key
be
pressed
allerthe
command letler (or "DOh"
be
sent by acontrol program), although
we
will
not
rcpcat
(his
\\hcn discussing
the
commands.
Also
note that any com-
mand
letter
may
be sent
in
either upper or lower casc. The
info
screcns shown
on
the next page
will
be returned
by
the
Control Intcrfacc.
Most cOlllmands have two versions: OIlC for azimuth. and
one
for
elevation. Commands are
not
echoed by
the
Control
IllIcrfacc. but acarriage return character ("DOh")
is
rcturned
oller evel) cOlllllland, and also aline
feed
e1m,"eler ("OAh")
if
the
command invoked returned data. Invalid commands
cause
..
?>"
to
be
relurned
and
the input buffer cleared. Note
that
all
angles arc
in
degrees, beginning with zero at the
most cOlllllerclock\\
ilic
azimUlh (or hori7ontal elevation).
Angles sent
to
the Control Interface
mUsl
be 3digils long
(Icn-Iero-padded).
J:

Co
1
lAND
LIST
z
o
~
w
p..
o
In
the
follO\\ing
cOlllmand
dc!)criptlon~.
the
elevation
ver-
sion
or
each command. \,here there
is
one. ihO'\11
in
pa-
rentheses (but don't
t)
pc
the parentheses). Remember that
elevation commands require the
G-5400B.
G-5600B
or
G-5500
AvE
IRotators.
or
the
GX-500 adapter and the
G-
500
or
G-550
Elevation Rotator.
0(02)
Off\el
cnlib,,";o/l for the Azimulh (Elevalion) :preset
rOla-
tor
manual!)
fully
counter-c1ock\\
isc
("len"
horizon
for
el-
evalion), send command, and press
[V)
-
[J]
("Y"
and
"ENTER")
on
the
computer
keyboard
to
store
setting.
H(H2,
H3)
Returns
list
of
commands
(see
page
19
and
20).
F
(F2)
FilII
Sc:ale
Calih,"titJII:
preset
rotator
manually
to
full
scale.
send command. adjust
OUT
VOL
ADJ
"immer
on
rcar
of
controller (or
GX-500
elevalion adapter) until
the
retumed
data
is
"+180
or
+450"
("+Onn+180"
forele\alion). Press
[J)
("ENTER")
on
Ihe
compuler keyboard 10 exit
the
calibm-
lion
routine.
R(U)
Start
lurning
the
rotator
to
the
right
(up)
Slart
turning
the
rotator
to
the
left
(do\\n).
A(E)
Stop
azimuth
(elevation)
rotation.
s
SlOp:
cancel
current
command
before
completion.
C(8)
Return current azimuth (ele\ation) angle
in
the
form
"AZ=aaa" ("EL=eee" for "B" command) degrees.
C2
Return
azimuth
and
elevation
("AZ..=888
EL=eee", \\here
"888"
azimuth."
eee"
elevation).
P36
Switch
the
azimuth
angle
to
360
degree
mode.
P45
Switch
the
al'imuth
angle
10450
degree
mode.
z
Toggle
the
staning
point
of
the
azimuth
indicator
needle
bel\\een"
(Nonh)"
and
"5
(South):'
This
command
is
ignored
\\hcn
the
rolalor
is
set
to
"450
degree
mode."
/6
L
(0)

CO
1\1ANI)
LIST
Xn
Select azimuth
rOlator
turning speed. ".here nI(slo\\est)
to
-I
(rastest). This command can
be
issued during rotation.
and lakes effect immediatel). There
is
no
equl\alem ror el·
c\ation.
Maaa
Turn to
888
degrees iuimuth, where
888
is
athree-digit
number bel\\een
"000"
and
"360"
or
"450"
(depending
on
rolatOr
t)
pc). Rotation starts
upon
c",cculion orlhe
COI11-
mand.
Msss
aaa bbb eee
rhis command. IOgether \\ith
Ihe
ITl
commnnd. provides
aUlomatic, timed
Irac~ing
of
moving objecls
or
propaga-
tion b) the Control IlHcrface itselr. This command stores
the time \'alue
ssssecond
to
\\ait bet\\cen '\Iepping
from
azimuth aaa to
bbb.
and then
to
ccc. etc. (rrom
"2"
to
as
man~
as
"3800" angles
ma~
be storcd
\\
itll
onc command).
ote
Ihat
lhis command
is
complelel) dinerent thalllhc
ITI
command
\\
ith
onl~
one parameter: \\hen multiple
paral11CICI3
arc
present. the liN
onl:
jc;
inlerpreted b)
the
("orllrolllllcrrace
a~
the
rotation
interval
sss.
not
all
angle.
Valid
ranges
are
"001"
to
"999"
lor sss.
and
"000"
to
"360"
or
"450"
(depend-
ing
on rolator type)
for
the
angles.
When
this
command
is
\t:nt,lllc parameters arc \Iored
in
the
COlllrollnlcrface\ RAM.
and
the
rotator turns
to
angle aaa
and
\\aits ror asubsequent
IT]
command
to
begin
the
actual
stepping. All
numbers
must
be
3digits. space-separated. Stored values remain
in
effeci
until
another
1M)
command
is
issued (Ihis may have
no
pa·
r<lInelers.
in
\\
hich
case
the
""?
>" error prompt
is
retumed,
but
memories
are
still
cleared). or
until
the
controller
is
tumed off
or b) loggling
the
GS-232B
off
and
on.
T
See
the
[M]
(above)
and
the
Iwl
(belo\\) command. tart
aut
matic stepping routinc (both alimuth and eievation):
turn rolalor 10 next sequentially memorized azimuth
(or
az-
el
pair.
ror
the
[wl command).
wait
sss sccond .
and
turn
to
nC\t
angle (or pair), cle. This command works only ira
long-
form 1M! or Iwj
has
been
is;ued
since
po\\er-up
or
the
lasl
rc'-)ct
z
o
-
~
""l
Q.,
o

z
o
-
~
I..:l
Q.,
o
18
COMMA
N
Retum serial number
of
current
I)
selected memorized point
lnnnnj. and
tOlal
number
of
memorized points
Immmmj.
in
the foml
=nnnrFmmmm.
Must be proceeded
b)
either a
10ng-fom'IMI or
Iwj,
and
a T command.
Used
only during
stepping (see
[T]
command).
The meaning
of
a"point" in this command fa
11
a
Vo,
ing
an
[M!
command
is
only
all
3timuth angle. so
in
this case nnnn
and
mmmm
can range lip
to
"3800"
(the limit defined in
the
EEPROM
xin the entral Interface). However. when
elevation
is
involved. a"point" following aIwJ command
is
represented by both an azimuth and
an
elevation angle.
in
which
case
nnnn
and
I1ll1lmm
can
range
lip
to
onl~
"1900."
since each "point"
is
apair
of
angles.
xI
he
EEP
RO
,t
m3)
be
'Hiuen
,,!tit
up
to
one
million
data points.
D
LIST
Eleva/ion Control Commands
1hese commands are ani) for az-el operation. Note that an
azimuth angle must always be supplied \\hen changing el-
evation. and
thaI
asetting poinl consists
ofa
pair
of
angles.
Waaa
eee
Turn to
BBB
degrees 31.imuth and
eee
degrees elevation.
\\here
BBB
is
athree-digit number between
"000"
and
"360"
or
"450"
(depending
on
rOlator
type) and
eee
is
a
three-digit number belween
"000"
and
"180."
Rotation
starts upon execution
of
the
command.
W
555
aaa
eee
aaa
555
...
This command
is
similar
[0
the
lMJ
cOnlmand: the first pa-
rameler
is
atime interval. and succeeding parameters are
anglcs.
\Vith
this
command. ho\\cver. angles are
in
3Lirnuth-
elevation pairs. each pair representing one antenna loca-
[ion.
At
most
"1900"
pairs can be sent and stofed
in
the
Control Interface.
As
\\
ith
the other commands. the time
intcnal range
is
limi[cd to
"001"
10
"999"
(seconds). azi-
mUlh
10
"000"
to
"360"
or
"450"
(depending
on
rolator
I)pe). and
ele\alionlo
"000"
to
"180:'
When
this command
is
sent. the rotators turn 10
the
titsl
BOB
,lLimu[h
parameter
and
the first eeeelevation parameter.
and
\\
ait
for asubsequent
ITI
command 10 begin
the
3ctual
stepping
(10
the
ne-.:t
azimuth-elevation pair). Stored
vallle~
Other manuals for GS-232B
2
Table of contents
Other Yaesu Recording Equipment manuals