Yasun YS-MBE01 Operating and maintenance manual

yASUN 岩尚科技
i
Foreword
Thank you for purchasing YASUN Technology Patch Type Heart Rate Monitor,
YS-MBE01, YS-MBE07. Please read and understand the contents of this instruction
manual carefully before using the product.
Product Name: Heart Rate Monitor
Model: YS-MBE01, YS-MBE07
Application: For real time heart rate monitoring.
Date of manufacture: see label.
Use period: 3 years
Manufacturer: Shenzhen Yasun Technology Co., Ltd.
Address: Room 305, 3rd Floor, Block A, Building 1, Huiye Science and Technology Park,
Tangjia Community, Guangguang Road, Fenghuang Street, Guangming District,
Shenzhen
Revision date of this instruction manual: May 8, 2020,
Version: A/4S

目录
ii
Company Contact Information:
Company Name: Shenzhen Yasun Technology Co., Ltd.
Address: Room 305, 3rd Floor, Building A, Building 1, Huiye Science and Technology
Park, Guanguan Road, Tangjia Community, Fenghuang Street, Guangming District,
Shenzhen Postcode: 518055
CS Telephone: 4001882836
Email: [email protected]
IoT Cloud Platform: https://yasunhealth.com
Statement
This publication, including all photos and illustrations, are protected by law, and all
copyrights belong to Shenzhen Yasun Technology Co., Ltd. (hereinafter referred to as
"the company"). This document may not be photocopied, reproduced or translated into
other languages without the prior written permission of the manufacturer. Pictures in this
manual are only for reference.

yASUN 岩尚科技
iii
Content
1、SAFETY PRECAUTIONS .......................................................................................................5
2、PRODUCT INTRODUCTION ...................................................................................................6
2.1 PRODUCT FEATURES .....................................................................................................6
2.2 APPLICATION AREA ...................................................................................................... 7
2.3 CONTRAINDICATIONS ................................................................................................... 7
2.4 PRODUCT COMPOSITION .............................................................................................. 8
3、PRODUCT USE INSTRUCTION ...................................................................................11
3.1 DEVICE ON/OFF ......................................................................................................... 11

目录
iv
3.2 APP SOFTWARE ..........................................................................................................12
3.2.1 APP software download, install and uninstall.................................................12
3.2.2 Register log in ....................................................................................................13
3.2.3 Sign out .............................................................................................................. 14
3.2.4 Connect Heart Rate Monitor ..............................................................................14
3.3 LOW BATTERY WARNING ............................................................................................ 15

yASUN 岩尚科技
5
When using the heart rate monitor device, please observe the following precautions:
This product is not suitable for babies weighing less than 10kg!
This product is not suitable for strong magnetic environment and shall not be shared with strong magnetic
equipment such as nuclear magnetic resonance.
This product shall not be shared with strong electrical equipment such as cardiac pacemakers, cardiac defibrillators
and electrical stimulators.
Please use the special YASUN self-adhesive stickers that comes with the device,other tapes cannot be used with this
device.
The user needs to wear the product in strict accordance with the method and position specified in this instruction
manual, otherwise the detection data may be incorrect.
Do not apply violent impact to this product and its accessories to avoid product damage.
1、Safety Precautions

6
This product should be prevented from entering water or getting close to heat or fire sources to avoid product
damage or battery top cover explosion accidents.
The maintenance of this product must be carried out by the manufacturer or professional technicians authorized by
the manufacturer in writing.
Do not disassemble and replace parts without permission.
When using the YASUN APP, please observe the following precautions:
This product needs to use the APP for device connection data transmission and work. Please do not uninstall or
change the YASUN APP software at will to avoid software failure or data loss. The APP software is free to use, and
the manufacturer provides users with free consultation and upgrade services.
Operation Condition: Temperature: +5℃~+45℃; Humidity: ≤95%; Air Pressure: 70kPa~106kPa
Storage Condition: Temperature: +5℃~+45℃; Humidity: ≤95%; Air Pressure: 70kPa~106kPa
2、Product Introduction
2.1 Product Features

yASUN
This product is a wearable patch monitoring device that can directly collect the heart rate. Heart rate monitoring
needs to be displayed and stored through the designated APP software and cloud client software. This product
collects dynamic heart rate, transmits them to the mobile terminal multi-parameter detection APP through Bluetooth,
and performs real-time display and data storage of heart rate waveform and heart rate locally on the mobile terminal.
The mobile terminal multi-parameter detection APP sends the ECG data to the cloud for analysis and storage in real
time.Ultra-small , ultra-light, easy to use, comfortable to wear, unlimited life, remote real-time monitoring and
many other advantages. The main unit and the battery top cover can be separated, and the two randomly configured
battery top covers can be used alternately, which can achieve long-term monitoring and heart rate data recording.
For the monitoring and recording of human body heart rate. Model YS-MBE01 can be used for arrhythmia,model
YS-MBE07 can be used to detect the location of the precordial leads, which can be used for arrhythmia and partial
myocardial ischemia. This product is not suitable for infant aircraft, vehicles, ambulances, field ambulances,
disaster relief, individual sports, sports events, family, work, study, travel, bathing, rest, sleep, etc.
Use with caution for those with skin allergies.This product is not suitable for babies weighing less than 10kg!
2.2 Application Area
2.3 Contraindications
Image2.1 YS-MBE01 Front Side

8
The composition of the patch type dynamic heart rate
monitor recorder YS-MBE01 (image2.1/ image2.2)and
YS-MBE07(image2.1,image2.5): YS-MBE01
host(image2.3B) / YS-MBE07 host(image2.5/
Image2.3B) ,double-side self-adhesive tape(image2.8/
Image2.9), charging device (2 in 1 charging connector and
battery removal device,image2.10 / image2.11) ,
YS-MBE01 / YS-MBE07 battery cover (image2.3A/ image 2.6 ),
2.4 Product Composition
Image2.2 YS-MBE01 Back Side

yASUN
and equipped with special YASUN multi-parameter detection
APP monitoring software.
Image2.3A YS-MBE01 Battery Cover
Image 2.3B YS-MBE01Host Side
Image 2.5 YS-MBE07 back side

10
Image 2.6 YS-MBE07 Battery Covers
Image2.8 double-side self-adhesive tape A
for YS-MBE01 and YS-MBE07
Image 2.9 double-side
self-adhesive tape B for
YS-MBE07

yASUN
After wearing the heart rate monitor YS-MBE01 and YS-MBE07, open the mobile multi-parameter detection APP,
3、Product Use Instruction
3.1 Device On/Off
Image2.10 Charging Device
Image2.11 Charging Device

12
press and hold the power switch button of the recorder for 3 seconds, and release. YS-MBE01, YS-MBE07 monitor
host vibrates 3 times, and the blue light flashes, indicating that the recorder has been activated and heart rate
monitoring has started. Make sure that the mobile terminal WIFI, or 4G, or 5G is connected, and the heart rate data
has been remotely transmitted to the cloud server in real time. The on/off
key is shown on the side of the product YS-MBE01 and YS-MBE07.
The multi-parameter detection APP is suitable for Android Andriod 6.0
version, Huawei HarmonyOS 2.0 version, Apple iOS 12.0 version, with
Bluetooth, WIFI, 4G, or 5G wireless communication function, and mobile terminals with storage space greater than
2G.Apple iOS mobile phone, Android Andriod, HarmonyOS smart phone APP software download, installation and
uninstallation: For users of Android Andriod, Huawei HarmonyOS mobile phone, Apple iOS mobile phone, please
enter "multi-parameter detection" in the APP Store search box, click the install button, then This multi-parameter
detection APP is automatically installed. Find the APP icon on the mobile phone desktop, long press the upper left
corner to display the delete button, as shown in Figure 4.3C, click to uninstall the APP.。
3.2 APP Software
3.2.1 APP software download, install and uninstall
Image 4.1 YASUN APP

yASUN
Scan code to download and install APP software: Users can also scan code to download and install, as shown in
image 4.4
Open the mobile phone WeChat or browser, find the QR code scanning
function, and perform the QR code scanning operation below, then you can
download and install.
3.2.2 Register log in
Open the multi-parameter detection APP, and the user should log in before
using the APP. The user login interface is shown in Figure 4.4A. There are
4 ways to log in. The login process of each login method is as follows:
1. Mobile phone number login
Enter the correct mobile phone number and verification code, click [Login], and after [Login Successful] is
displayed, it will automatically enter the main interface of the APP. If the mobile phone number is not registered,
the user will be automatically registered.
2. Experience login
Image 4.4

14
Click [Experience Login], after displaying [Login Successful], it will automatically enter the main interface of the
APP. The experience account is logged in according to the unique identification code of the mobile phone number,
one mobile phone for one account.
3. Login with account and password
Click [Password Login] to jump to the [Account and Password Login Page] as shown in Figure 4.3B, enter the
correct account and password, click [Login], and after [Login Successful] is displayed, it will automatically enter
the main interface of the APP.
3.2.3 Sign out
Click the main menu button in the main menu item of the APP, select the [Settings] main menu, and click [Logout]
in the settings list to log out normally. After logging out, when you reopen the APP, you need to log in again; if you
only close the APP without logging out, you can use the APP normally without logging in when you open it again.
3.2.4 Connect Heart Rate Monitor
Connect the dynamic heart rate recorder, transmit the information collected by the device to the cloud platform
service for processing, and return the processing results to the APP interface. To complete this function, you first
need to establish a Bluetooth connection with the acquisition device to obtain data.

yASUN
The patch-type monitor can work continuously for no less than 72 hours when the internal battery is fully charged.
When the remaining battery power of the SMD multi-parameter recorder drops to 15%, the multi-parameter
detection APP will automatically pop up a prompt box of "Please replace the battery in time". When the remaining
battery power of the SMD multi-parameter recorder is lower than 10%, The patch multi-parameter recorder will
automatically shut down, and the multi-parameter detection APP will automatically pop up a prompt box to prompt
the device to shut down.
European agent information:
eVatmaster Consulting GmbH
Bettinastr. 30,60325 Frankfurt am Main,Germany
contact@evatmaster.com
3.3 Low battery warning

16
Warranty Card
Please fill in the warranty card carefully and send it to the after-sales service center of Shenzhen Yanshang Technology Co., Ltd. for
registration within one week. During the warranty period, if you need technical advice or the instrument fails (human errors and
accidents do not belong to this category), please contact the after-sales service center. Products beyond the warranty period or users
with special service requirements are welcome to consult the after-sales service center of Shenzhen YASUN Technology Co., Ltd.
Personnel who are not authorized and trained by the company are not allowed to start the machine for maintenance.
Name
Model
Item
Date

yASUN
User Name
Warranty
Contact Info.
Tel.
Address

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in
portable exposure condition without restriction.