3G SDI Frame Synchronizer
WARNING
Class 1 Laser Product
SDI Input
SDI OutputsFiber I/O (option)
12V Power Input
SDI Present
Power and
Prog. Settings LED
Module Settings
Module Reset (through hole under GPI)
Analog REF IN
REF Status LED
Module LEDs
The module has several LEDs included to indicate status. Function is
described below:
SDI Present LED
= Valid SDI Signal connected
= (out) Non valid SDI signal or signal missing
REF Status LED
REF Input is bi-level or tri-level analog sync (auto detect), and will cross lock and convert the
SDI output to the REF standard if there is a“mismatch” between the SDI in and REF.
= REF is present and matches the SDI input format
= REF is present but does not match the SDI input format. The SDI
output is being converted to match REF input standard
= (out) REF signal is not present / valid
Power / Status LED
= Power OK, and no internal programmed settings are present
= Power OK, and some internal programmed settings are active*
= Power OK, but the module switch settings have been overwritten
with the yelloGUI application. (Manual operation of any local switch
will revert module back to the physical switch settings, and will change
LED status back to yellow or green).
= (out) Power not present
* Some additional internal settings have been made using yelloGUI and the
LED indicates this by turning yellow. The module can be reset to factory default
using the yelloGUI application, or by using the reset switch on the side of the
module, which can be accessed though a hole with a paper-clip (or similar)
USB Port
The USB port is used for rmware updates and for PC/MAC control using
the yelloGUI software. Download yelloGUI from our website:
www.lynx-technik.com > support > downloads > yelloGUI software
Firmware updates are always provided free of charge and are available
via the yelloGUI.
Fiber I/O Options
The PVD 1800 can accommodate a
variety of ber SDI I/O options which are
detailed below. These are SFP sub
modules and simply plug into the side
of the module. These can be added at
any time.
USB
(for prog settings and
rmware updates)
GPI inputs
Delay Adjustment
Note: We also have a selection of higher power 80km CWDM ber options
if needed. Please visit our website or contact your LYNX Technik AG sales
representative for more details
SDI Fiber Transmitter Options
Model Description Power
OH-TX-1-LC / ST / SC SFP Fiber TX - Singlemode - LC, ST or SC conn. - 10km -5dBm (1310nm)
SDI Fiber Receiver Options
Model Description Sensitivity
OH-RX-1-LC / ST / SC SFP Fiber RX - Singlemode - LC, ST or SC connector -18dBm
SDI Fiber Transceiver Options
Model Description Power Sense
OH-TR-1 SFP Fiber RX/TX - Singlemode, LC Connector - 10km -5dBm -16dBm
OH-TR-0-850 SFP Fiber RX/TX - Multimode, LC Connector - 300m -5dBm -15dBm
SDI CWDM Fiber Transmitter Options
Model Description Power
OH-TX-4-XXXX CWDM SFP Fiber TX - Singlemode LC Conn. - 40km
XXXX=Wavelength. 18 according to ITU T G692.2
1270nm through 1610nm
-1dBm
SDI CWDM Fiber Transceiver Options
Model Description Power Sense
OH-TR-4-XXXX CWDM SFP Fiber RX/TX - Singlemode LC Conn. - 40km
XXXX=Wavelength. 18 according to ITU T G692.2
1270nm through 1610nm
-1dBm -20dBm
www.lynx-technik.com
Module LEDs
The module has several LEDs included to indicate status. Function is
described below:
SDI Present LED
= Valid SDI Signal connected
= (out) Non valid SDI signal or signal missing
REF Status LED
REF Input is bi-level or tri-level analog sync (auto detect), and will cross lock and convert the
SDI output to the REF standard if there is a“mismatch” between the SDI in and REF.
= REF is present and matches the SDI input format
= REF is present but does not match the SDI input format. The SDI
output is being converted to match REF input standard
= (out) REF signal is not present / valid
Power / Status LED
= Power OK, and no internal programmed settings are present
= Power OK, and some internal programmed settings are active*
= Power OK, but the module switch settings have been overwritten
with the yelloGUI application. (Manual operation of any local switch
will revert module back to the physical switch settings, and will change
LED status back to yellow or green).
= (out) Power not present
* Some additional internal settings have been made using yelloGUI and the
LED indicates this by turning yellow. The module can be reset to factory default
using the yelloGUI application, or by using the reset switch on the side of the
module, which can be accessed though a hole with a paper-clip (or similar)
USB Port
The USB port is used for rmware updates and for PC/MAC control using
the yelloGUI software. Download yelloGUI from our website:
www.lynx-technik.com > support > downloads > yelloGUI software
Firmware updates are always provided free of charge and are available
via the yelloGUI.
yellobrik
®
LYNXTechnik AG www.lynx-technik.com
GPI inputs
There are 4 GPI inputs provided
GPI 1 - Switches Fiber and Electrical inputs (dip switch 6 = ON)
GPI 2 - Freeze the SDI output
GPI 3 - (low) Enables “latch”mode
GPI 4 - (low) Disables “latch”mode
Delay Adjustment
A rotary control is provided to adjust the video output delay. A
maximum delay of 30 frames adjustable in frame / lines / pixels
increments is possible. Pressing (clicking) the rotary control cycles
between the 4 adjustment modes, which are indicated by the LEDs.
Connections
All connections are clearly indicated on the module. Electrical SDI and
REF IN connections are made using standard 75 Ohm BNC connectors.
The module supports 4 external GPI connections, these are contact
closure connections and are made using a standard RJ45 connector.
Connection details below.
Settings
A dip switch is provided for module
conguration.
Each switch function is described
below.
Technical Specifications
SDI Input 1 x 75 Ohm BNC electrical SDI input + 1 x optional fiber SDI input
Serial digital video SMPTE, 292M, 424M, 259M with automatic video
format and standard detection
10 bit 4:2:2 (Y,Cr,Cb)
Multi-standard input
SDTV (525/625)
720p and 1080p (23.98/24/25/29.97/30/50/59.94/60 Hz)
1080i (50/59.94/60 Hz)
Electrical Return Loss: > 15dB (270Mbit), > 10dB (2.97 Gbit)
SDI Outputs 2 x 75 Ohm BNC electrical SDI outputs. SMPTE, 292M, 424M, 259M
1 x optional fiber SDI output
Output follows input format
Timing Jitter: <0.2 UI @ 270Mbit/s, <1.0 UI @ 1.5Gbit/s, <2.0 UI @ 2.97Gbit/s
Alignment Jitter: <0.2 UI @ 270Mbit/s, <0.2 UI @ 1.5Gbit/s, <0.3 UI @ 2.97Gbit/s
Return Loss: >15dB (270Mbit), >10dB (2.97 Gbit)
Cable Equalization 270Mbit: Up to 340m (1.115ft) using Belden 8281
Cable Equalization 1.485Gbit: Up to 150m (492ft) using Belden 1694A
Cable Equalization 2.97Gbit: Up to 110m (360ft) using Belden 1694A
Fiber I/O Optional plug in SFP for optical SDI I/O (see fiber options table)
SMPTE 297M - 2006
Reference
Input
SDTV: Analog 525 or 625 bi-level sync
HDTV: All tri-level sync standards (exceptions 1080p 50/59.94/60Hz)
Cross lock compatible
SMPTE 274M, SMPTE 296M - 75 Ohm BNC connector
Video Delay Timing Adjustment: Up to 30 frames.
Manually adjustable in frame / line / pixel increments
GPI Connector RJ45 with4 x External GPI inputs:
GPI 1 is used for Electrical / Optical SDI changeover
GPI 2 is used for force a “freeze” of the signal
GPI 3 is used to enable the “latched” changeover mode
Power +12VDC @ 5.5W nominal - ( supports 7 - 24VDC input range )
Note. The depiction of the RJ45
connector and pin numbering is
made looking into the female
connector on the module.
1 = Freeze on TRS - When set to ON the SDI output will “freeze” when a TRS error
is detected on the SDI input
2 = Freeze Mode - Sets the freeze output to be the video image or test pattern
3= Output if no input - Sets what the SDI output is when there is no input signal
4 = Test Pattern - Turns the test pattern generator ON or OFF
5 = H-Flip - Flips the SDI output horizontally
6 = GPI Switch Inputs - When set to ON - GPI 1 will switch the SDI input between
electrical (GPI open) and Fiber (GPI closed) - this switch overrides the next
two switch settings
7 = Auto Input Select - If the main input is lost then the module automatically
switches to the other SDI input. The “main”input is determined by the
setting of the next dip switch
8 = Fiber Input - Switch SDI input between Electrical (OFF) and ber (ON)
When an LED is illuminated turning
the rotary control will adjust the
delay in the selected increments
(frames / lines / pixels).
The 4th mode is an “overview” mode and all 3 LEDs will be green if
there is no delay adjustment set (0) and yellow if the setting is not zero.
Turning the rotary control will have no eect in “overview” mode.
Power Lead Strain Relief
The module has a small hole in the case located above the power
connection. To prevent the power lead being accidentally pulled out,
use the supplied tie-wrap and secure the lead as shown below.
GPI 4 is used to disable the “latched” changeover mode

Popular Recording Equipment manuals by other brands

EMS CPC-PCIe user manual

EMS

EMS CPC-PCIe user manual

TIR ControlFX Director quick start guide

TIR

TIR ControlFX Director quick start guide

Fostex XR-7 owner's manual

Fostex

Fostex XR-7 owner's manual

eamlab MUSICA D101 user manual

eamlab

eamlab MUSICA D101 user manual

DRAKE PC1601 datasheet

DRAKE

DRAKE PC1601 datasheet

Beckhoff CX2500-0030 manual

Beckhoff

Beckhoff CX2500-0030 manual

Beckhoff CX1500-M510 manual

Beckhoff

Beckhoff CX1500-M510 manual

Pioneer DVR-RT502-S Service manual

Pioneer

Pioneer DVR-RT502-S Service manual

NST NVR32 user manual

NST

NST NVR32 user manual

Vestax VCM-100 owner's manual

Vestax

Vestax VCM-100 owner's manual

Digital Equipment DA10 manual

Digital Equipment

Digital Equipment DA10 manual

Ametek Gemco 2120 installation manual

Ametek

Ametek Gemco 2120 installation manual

IXXAT CAN@net II manual

IXXAT

IXXAT CAN@net II manual

Dometic WAECO MagicSpeed CBI 150 Installation and operating manual

Dometic

Dometic WAECO MagicSpeed CBI 150 Installation and operating manual

HP 7414A Operating and service manual

HP

HP 7414A Operating and service manual

Calrec SUMMA installation manual

Calrec

Calrec SUMMA installation manual

AirTools Voice Processor 2x quick start guide

AirTools

AirTools Voice Processor 2x quick start guide

dbx DriveRack 220i manual&nbsp;

dbx

dbx DriveRack 220i manual&nbsp;

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.