LED PAR LIGHT(infrared control)
Model: YR-P0319SIR
(R4/G5/B5/W5)
Con

tents
Section 1.Getting Started
Unpacking
Safety Instruction
Section 2. Set Up
Installation
Controlling Board
Machine Connection
Section 3. Troubleshooting
Troubleshooting
Section 4. Reference
Control Menu
DMX Protocol
Specification
Section 5. IR Controller

Section 1. Getting Started
Unpacking
Safety Instruction
Unpacking
1pc Fixture
1pc User Manual
1pc Power switchable Cable
1pc Signal Cable
IR controller
Thanks for using our LED PAR LIGHT range. Carefully unpack the box and check the
contents to ensure that all parts are present and in good conditions. If anything looks as if it
has been damaged in transit, notify the shipper immediately and keep the packing material for
inspection. Again, please save the carton and all packing materials. If a fixture must be
returned to manufacturer, it is important that the fixture be returned in the original
manufacturer box and packing.

Safety Instruction
Please conserve this manual as operation guidance. If you sell this product to other user, please
make sure that they also receive this user manual.
Always make sure that you are connecting to the proper voltage and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
The fixture is intended to indoor use only. To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable, explosive or corrosive materials surrounded
in 0.5 meter while operating.
The unit must be installed in a location with adequate ventilation, at least 50CM away from
adjacent surfaces. Be sure that no ventilation slots are blocked.
Do not operate at ambient temperatures higher than 104℉(40℃).
Safe wire should be used to install machine. Bearing of safe wire should be 3 times of the
machine weight. Complimentary signal cable transmits signals to 20 unit fixtures at most. Signal
amplifier is a must to connect more fixtures. Sectional area of complimentary power cable is 1㎡.
In daisy chain model, it allows to connect to 4 fixtures at most.
Always disconnect from the power source before servicing or replacing fuse/lamp and be sure to
replace with same fuse/lamp size and type. Cut off power before moving, repairing and cleaning
the machine.
Secure fixture using a safety chain and carrying handles. Never carry the fixture by its cord.
In case of failure or misfunction occurred, stop using the unit immediately.
Repairs carried out by unskilled people can lead to damage or malfunction. Buy the same spare
parts/components from manufacturer directly.
To avoid electric shock, all fixtures must be connected to circuits with a suitable ground. Make
sure the power cord is never crimped or damaged. Do not power on and power off the fixture in a
short time. For your safety, do not touch fixture when running.
When use DMX controller, please make sure that there is no interference sources(e.g. intercom,
high frequency radio waves and radiation source)
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please
contact your local distribution or after-sale service center.
本公司有权对此份产品说明书进行修改,恕不另行通知。
Our company reserve right to revise this user manual without notice!
Innovation | Efficiency | Dedication | Harmonious
For your safety,please read this user manual carefully before
operation. The machine should be operated by qualified engineer!

Section 2. Set Up
Installation
Controlling Board
Machine Connection
Installation
This machine should be mounted through the screw holes of truss. Safety wire is a must to
fix fixture well. Make sure truss and safety wire have strong load capacity to bear 3 times
weight than fixture at least. This machine should be installed by qualified technician.

Controlling Board AND Front display panel
1. Display
Display menu and selected function.
2. Button
MENU
switch menu function
UP
On function: page up
On numerical value: increase value
DOWN
On function: page down
On numerical value: reduce value
ENTER
Settle selected function and value
3. DMX signal input
Control model by DMX signal,please use 3pin XLR signal cable.
4. DMX Signal output
Transfer DMX signal to next model, please use 3pin XLR signal cable.
5. Power PLUG
Connect to obtain power (attention:please use connect to stated voltage.)
Specification:
Voltage:AC110V-240V
Frequency:50/60Hz
Rated Power:80W
LED: 3WX19pcs (RED 4/GREEN 5/BLUE5/WHITE5)
Control:DMX512
Beam angle: 30°
Channel: 9/5 channels (switchable)
Control Mode:DMX 512, AUTO, SOUND, IR CONTROL, MASTER/SLAVE
Level of Protection: IP22
Stock: Clean and Dry place
Running Temp.: 0°C~40°C
Weight: 1.1kg
Size: 19*16*14cm (excluding bracket)

DMX protocol
DMX512 Channel Chart:(5CH)
CH
Function
Specification
CH1
Dimmer
R G B W color from dark to bright
CH2
R dimmer
Red color from dark to bright
CH3
G dimmer
Green color from dark to bright
CH4
B dimmer
Blue color from dark to bright
CH5
W dimmer
White color from dark to bright
DMX512 Channel Chart:(9CH)
CH
Function
Specification
CH1
Dimmer
R G B W color from dark to bright
CH2
R dimmer
Red color from dark to bright
CH3
G dimmer
Green color from dark to bright
CH4
B dimmer
Blue color from dark to bright
CH5
W dimmer
White color from dark to bright
CH6
Strobe
7 color flash speed, from slow to fast
CH7
Color mix
Seven color mix
CH8
Auto
0-60: shade ;61-120: skip ;121-180:
shade+skip ;181-240: flash by sound ;
241-255: skip by sound
CH 9
Auto Speed
DMX8 Channel auto speed & sound
volume adjust(from slow to fast)
Machine Connection
Cable Connectors
Cables must have a male XLR connector on one end and a female XLR connector on the
other end.
A word on termination: DMX is a resilient communication protocol,
however errors still occasionally occur. Termination reduces signal errors, and therefore best
practices include use of a terminator in all circumstances. If you are experiencing problems
with erratic fixture behavior, especially over long signal cable runs, a terminator may help
improve performance.
To build your own DMX Terminator: Obtain a 120-ohm, 1/4-watt
resistor, and wire it between pins 2&3 of the last fixture. They are also readily available from
specialty retailers.
Master-Slave control model:
Set up one fixture as Master fixture(triggering),other fixtures as slave
fixtures(receiving trigger signals).Set up all fixtures same address value or
following DMX controller performance(Attention: all fixtures use the same DMX
Maximum 8 PCS fixtures connected by Daisy chain connection.

channel-7 or 11CH)
Section 3. Troubleshooting
Section 4. Reference
Control Menu
DMX Protocol
Specification
Control Menu
No.
Manual
Function Specification(Press” ENTER”)
1
r— —
r000 to r255 : from dark to bright
2
g— —
g000 to g255: from dark to bright
3
b— —
b000 to b255: from dark to bright
4
n— —
n000 to n255: White from dark to bright
The 4 color’s
different
brightness
can mix out
all kinds of
color
5
C— —
C000 to C255:7 color shade speed,from
slow to fast
6
J— —
J000 to J255:7 color skip speed,from
slow to fast。
7
FS— —
FS00 to FS09:choose flashing color
8
F— —
F000 to F255:flash speed,from slow
to fast
9
LS— —
LS00 to LS09:choose color
10
L— —
L000 to L255:7 color from dark to bright。
11
U— —
U00 to U255 :sound active speed, from
slow to fast
12
A— —
A000 to A255:auto speed, from slow to
fast
13
d9CH
DMX 9 channel mode, should connect
with DMX controller
14
d5CH
DMX 5 channel mode, should connect
with DMX controller
Probable cause(s)
Remedy
No power to fixture
Check power cables
Primary fuse blown
Replace fuse
No response from
fixture when power
is applies
Secondary fuse
blown
Replace fuse
Controller not
connected
Connect controller
Incorrect
addressing of the
fixtures
Check address setting on fixture and controller
Bad data link
connection
Inspect cables and correct poor connections
and/or broken cables.
Conflict between
tracking and vector
control
Eliminate scene cross-fade on controller
Data link not
terminated
Insert termination plug in output of last fixture
Fixture resets but
does not respond
correctly to
controller(DMX
mode operation)
Defective fixture or
2 devices
transmitting on link
Bypass fixtures one at a time until normal
operation is regained:unplug both connectors and
connect them directly together
Colors cannot be
mixed
Random color
mixing is on
Turn off random color mixing
Fixture does not
reset correctly
Electronic or
mechanical failure
Contact service technician
Lamp missing or
blown
Disconnect fixture and replace lamp
No light, lamp cuts
out intermittently,or
burns out too
quickly
Fixture or lamp is
too hot
Allow fixture to cool. If problem persists,contact
service technician

Section 5.IR controller
up
down
off
on
RED
GREEN
BLUE
WHITE
COLOR1
COLOR2
COLOR3
STROBE
COLOR4
COLOR5
COLOR6
COLOR
CHANGE
COLOR7
COLOR8
COLOR9
FLADE
COLOR10
COLOR11
COLOR12
SOUND
Controlled by IR only
OFF- LED OFF
ON – ALL LED FULL BRIGHT
COLOR CHOOSE AREA- CHOOSE THE COLOR YOU WANTED
UP/DOWN- PRESS IT TO CHANGE THE BRIGHTNESS OF THE COLOR OR
SPEED OF STROBE/COLOR CHANGE/FLADE OR DETECTION SENSE OF
SOUND ACTIVE.
Change to DMX controller
Please ON and press UP/DOWN to change the DMX address of par light. And edit the
program by the DMX controller. (default setting is lead to d---)
Importance- IR controller is recommended control distance 5meters MAX.
Table of contents
Other YELLOWRIVER Dj Equipment manuals

YELLOWRIVER
YELLOWRIVER YR-1190 User manual

YELLOWRIVER
YELLOWRIVER YR-W0372T User manual

YELLOWRIVER
YELLOWRIVER YR-W1004H User manual

YELLOWRIVER
YELLOWRIVER YR-COB5002 User manual

YELLOWRIVER
YELLOWRIVER YR-IP1007H User manual

YELLOWRIVER
YELLOWRIVER YR-W0384T User manual

YELLOWRIVER
YELLOWRIVER YR-W1036Q User manual

YELLOWRIVER
YELLOWRIVER YR-IP350 User manual

YELLOWRIVER
YELLOWRIVER YR-S4001 User manual