YewdaleDefiant 980003 Installation manual

yewdale.co.uk
Part no: 980003
Programming Instructions
for YewdaleDefiant® motor
(980003)
Programming Instructions
for YewdaleDefiant® motors
(980003)

YewdaleDefiant® programming instructions Part no: 9800032
Programming:
Applications:
Press PROG for
1 second.
Press PROG.
Motor will beep
Charger
8.4DC 1.0A
Solar Panel
Built in lithium battery Built in lithium battery
Fully charged within 4 hours. Please
remove battery charger after full charge.
In direct sunlight battery is fully
charged within 2 days.
Application 1: Lithium Battery Power Application 2: Lithium Battery Power
Motor will shunt once. Press UP. Motor shunts once again.
Programming is complete.
Change direction: (of travel if required)
Press STOP on the transmitter
for 5 seconds.
Motor will shunt once. Press DOWN. Motor shunts once again.
Programming is complete.
Programming Instructions
YewdaleDefiant®7.4v DC Solar Powered Tubular Motor (980003)
with inbuilt radio receiver, transformer and electronic limit stop

Call: +44 (0)1268 570900 Fax: +44 (0)1268 732509 Email: [email protected] Visit: www.yewdale.co.uk 3
First limit position setting:
Other limit position settings:
Press PROG on the
transmitter for 1
second.
Move the motor to the
desired position.
Press PROG on the
transmitter for 1
second.
Press PROG for 1 second
to save the limit position.
(If there’s no other action within 30 seconds. the motor will exit from the limit position preparation automatically)
(If there’s no other action within 30 seconds. the motor will exit from the limit position preparation automatically)
Motor will shunt once
to indicate limit stop
setting mode.
Press PROG on the
transmitter for 1 second.
Press UP adjusting the
motor to the required
position to set the UP
limit positionas first
limit. Or press DOWN to
set the DOWN limit stop
as the first position.
Motor will shunt
once to indicate limit
setting mode.
Motor shunts once
again. The limit setting
has been saved.
Motor shunts once
again. The limit setting
has been saved.

YewdaleDefiant® programming instructions Part no: 9800034
Programming Instructions
YewdaleDefiant®7.4v DC Solar Powered Tubular Motor (980003)
with inbuilt radio receiver, transformer and electronic limit stop
Delete the limit stop position (please note: the first limit position can’t be deleted)
Let the motor run to the
limit stop position that is to
be deleted.
Press PROG for
7 seconds.
Motor will shunt
once to indicate limit
setting mode.
Within 7 seconds the motor will
shunt once again. The preset
limt position is now cleared.
Limit position fine tuning:
Adjust to the
required position.
Press PROG for 1 second to save
the limit position.
(If there’s no other action within 30 seconds. the motor will exit from the limit position preparation automatically)
Press PROG for 1
second.
Motor will shunt once to
indicate limit setting mode.
Let the motor run into the
limit stop position that needs
fine tuning.
Motor shunts once again. The
fine tune setting has been
saved.

Call: +44 (0)1268 570900 Fax: +44 (0)1268 732509 Email: [email protected] Visit: www.yewdale.co.uk 5
Limit position setting:
1.A maximum of six dierent limit stop positions can be set. The furthest two
positions are called the UP and DOWN limit stop positions. The others are
called the middle limit stop positions;
2.When the first limit position is in the UP limit stop position (as below
illustration), all other limit positions can only be set below this position; the
same applies when setting the first DOWN limit stop position, all other limit
stop positions can only be set above this position;
3.Every limit stop position can be fine-tuned or deleted separately (The first
limit stop position can only be fine-tuned but can’t be deleted separately. It
can only be deleted by resetting the memory);
4.The motor will stop at the next limit stop position after accepting an UP/
DOWN instruction. When it reaches the UP limit stop position, any additional
UP instruction is cancelled out; when it reaches the DOWN limit stop
position, the DOWN instruction is also cancelled;
5.Pressing either the UP/DOWN button twice on the transmitter within 1
second will instruct the motor to go directly to the UP/DOWN limit stop
position without stopping at any middle limit stop.
The third limit stop position
The first limit stop position (Up limit position)
The third limit stop position
The third limit stop position
The second limit stop position
All the other
limit positions
can be set below
the first limit
position

YewdaleDefiant® programming instructions Part no: 9800036
Programming Instructions
YewdaleDefiant®7.4v DC Solar Powered Tubular Motor (980003)
with inbuilt radio receiver, transformer and electronic limit stop
Add the new transmitter:
Delete single channel memory:
Press STOP on the transmitter
for 5 seconds.
Press STOP on the transmitter
for 5 seconds.
Motor will shunt once.
Motor will shunt once.
Press UP on the new
transmitter.
Press PROG for 1 second.
Motor shunts once again.
The transmitter is stored.
Motor shunts once again. Single
channel has been deleted.
Delete all the memories:
Turn the motor o:
Press STOP for 5 seconds.
(After deleting all codes, the motor will be restored to factory setting)
Press PROG for 7 seconds
within 10 seconds of
pressing STOP.
Motor will shunt once.
Pres PROG on the
motor for 7 seconds.
Motor will shunt twice
within 7 seconds. The
memory has been deleted.
Motor will shunt once.
Motor will beep and
shunt once.
Motor will beep again after
7 seconds. The motor has
been turned o.

Call: +44 (0)1268 570900 Fax: +44 (0)1268 732509 Email: [email protected] Visit: www.yewdale.co.uk 7
Items Problems Cause Solution
1
After connecting power,
the motor doesn’t work
or works slowly
1. Connected with the wrong voltage
2. Overloading
3. Incorrect installation leading to
motor jamming
1. Change to the correct voltage
2. Choose suitable motor torque
3. Check the components
2
The motor stops
suddenly whilst
running
1. Motor has exceeded overheating
protection +130oC
2. Power was cut o
1. After the motor has cooled suciently, motor
will perform as required
2. The motor will resume once power is back on
Trouble Shooting:

Yewdale, Enterprise Way,
Wickford, Essex SS11 8DH
Call +44 (0)1268 570900
Fax +44 (0)1268 732509
Email [email protected]o.uk
Visit yewdale.co.uk
For more information on all
Yewdale products, please call
the sales department.
curtain track systems
yewdale.co.uk
see things differently
A concise approach to
a broad spectrum of
commercial curtain
track requirements with
simplistic control options
and designed for almost
every application.
®
cubicle and shower screens
yewdale.co.uk
see things differently
A dedicated range of privacy
and shower curtains with a
primary infection control
focus, providing an all-
encompassing solution to
increased levels of dignity.
®
cubicle and track systems
yewdale.co.uk
see things differently
The industry’s preferred
choice of maintenance
free privacy track systems
providing enhanced personal
welfare throughout the entire
healthcare and public sectors.
®
magnetic anti-ligature system
yewdale.co.uk
see things differently
The only fail-safe range of
exclusive anti-ligature products
designed to maximise the
safety of persons by removing
the death potential where
secure care is required.
®
fabric and blind systems
A comprehensive range
of window blind systems
designed with unique
technical features and to
the exacting specifications
that active commercial
environments demand.
yewdale.co.uk
see things differently
®
Table of contents
Other YewdaleDefiant Engine manuals
Popular Engine manuals by other brands

Infinitum
Infinitum Aircore EC Installation, operation & maintenance manual

Beckman Coulter
Beckman Coulter SW 41 Ti user manual

AMS
AMS XM540-W270-T/R Specifications

Ametek
Ametek dunkermotoren BG 75 SI Series instruction manual

Kyosho
Kyosho GXR28 instruction manual

Magnum
Magnum XL .52RFS operating instructions

Engine distributors
Engine distributors CSG 637 Operator's handbook

Mitsubishi
Mitsubishi 4G6 series Workshop manual

Nakanishi
Nakanishi BMS-4040-RGD-03M Operation manual

Duratrax
Duratrax TORQ16 Instruction

SEW-Eurodrive
SEW-Eurodrive MOVIMOT MMxD Series operating instructions

Hyundai
Hyundai L500 SERIES Installation and operation manual