YOKOGAWA XS110A User manual

User’s
Manual
IM01W06D01-01EN
1st Edition
XS110A
Wireless Communication Module
IM01W06D01-01EN

CONTENTS
Toc-1
1. Introduction .............................................................................................1-1
1.1 Safe Use of This Product ......................................................................................1-4
1.2 Radio Waves.........................................................................................................1-4
1.3 Warranty................................................................................................................1-5
2. Notes on Handling ...................................................................................2-1
2.1 ChecktheModelandSpecications ....................................................................2-1
2.2 Transport ..............................................................................................................2-1
2.3 Storage .................................................................................................................2-1
2.4 Selecting the Installation Location ........................................................................2-2
2.5 Restrictions on Use of Radio Transceivers ..........................................................2-3
2.6 Explosion Protected Instrument............................................................................2-3
3. Component Names .................................................................................3-1
4. Installation ................................................................................................4-1
5. Operation .................................................................................................5-1
6. Maintenance .............................................................................................6-1
6.1 Replacing the Battery............................................................................................6-1
6.2 Handling the Battery .............................................................................................6-4
7. GeneralSpecications...........................................................................7-1
7.1 STANDARD SPECIFICATIONS ..........................................................................7-1
7.2 SoftwareSpecications .......................................................................................7-2
7.3 MODEL AND SUFFIX CODES.............................................................................7-3
7.4 OPTIONAL ACCESSORIES ................................................................................7-3
7.5 Outline ..................................................................................................................7-4
7.6 Regulatory Compliance Statements.....................................................................7-5
Revision Information ........................................................................................i
1st Edition: July 2020
All Rights Reserved, Copyright © 2020, Yokogawa Electric Corporation

1-1
<Introduction>
IM 01W06D01-01EN
1. Introduction
Thank you for purchasing XS110A Wireless Communication Module. This
manual provides important information and installation and maintenance
instructions for using the XS110A Wireless Communication Module
(Hereinafter, it is described as XS110A.) correctly and safely.
The XS110A can be connected to an XS-series Measurement Module.
The battery mounted on the XS110A supplies power to the connected
Measurement Module.
The function description, setting, operation, and maintenance of the XS-series
are described in the Sushi Sensor Series Software Edition (IM01W06C01-
01EN), so be sure to read it and use it correctly.
TheSushiSensorSeriesSoftwareEdition(PDFles)candownloadfromour
company home page (http://www.sushisensor.com/).
Table 1.1 Related Documents
Document Name Document No.
GeneralSpecications
XS110A Wireless Communications Module
GS01W06D01-01EN
User's Manual
Sushi Sensor Series Software Edition
IM01W06C01-01EN

1-2
<Introduction>
IM 01W06D01-01EN
nRegarding This Manual
• Thismanualshouldbeprovidedtotheenduser.
• Thismanualandtheidenticationtagattachedonthepackingbox
are essential parts of the product; keep them in a safe place for future
reference.
• Thecontentsofthismanualaresubjecttochangewithoutpriornotice.
• Allrightsreserved.Nopartofthismanualmaybereproducedinanyform
without Yokogawa’s written permission.
• Yokogawamakesnowarrantyofanykindwithregardtothismanual,
including,butnotlimitedto,impliedwarrantyofmerchantabilityandtness
for a particular purpose.
• Ifanyquestionarisesorerrorsarefound,orifanyinformationismissing
fromthismanual,pleaseinformthenearestYokogawasalesoce.
• Thespecicationscoveredbythismanualarelimitedtothoseforthe
standardtypeunderthespeciedmodelnumberbreak-downanddonot
covercustom-madeinstruments.Whenproductswhosesuxcodeor
optional codes contain code “Z” and an exclusive document is attached,
please read it along with this manual.
• Pleasenotethatchangesinthespecications,construction,orcomponent
partsoftheinstrumentmaynotimmediatelybereectedinthismanualat
the time of change, provided that postponement of revisions will not cause
dicultytotheuserfromafunctionalorperformancestandpoint.
nSafety,Protection,andModicationofthisProduct
• Thisproductisdesignedtobeusedbyapersonwithspecialized
knowledge.
• Toprotecttheoperator,product,andsystemcontrolledbytheproduct,
observe the safety precautions described in this manual. If users handle
contrary to these instructions, we cannot guarantee safety.
• TheModicationoftheproductisstrictlyprohibited.
• Repairormodicationtothisinstrumentbycustomerwillcausea
malfunctionofexplosionprotectfunctionandhazardoussituation.Ifyou
needtorepairormodication,pleasecontactthenearestYokogawaoce.

1-3
<Introduction>
IM 01W06D01-01EN
• Thefollowingsafetysymbolsareusedinthismanual:
WARNING
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,could
resultindeathorseriousinjury.
CAUTION
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,mayresult
inminorormoderateinjuryorphysicaldamage.Itmayalsobeusedtoalert
against unsafe practices.
IMPORTANT
Indicates that operating the hardware or software in this manner may
damage it or lead to system failure.
NOTE
Draws attention to information essential for understanding the operation
and features.
nTrademarks
• SushiSensorisaregisteredtrademarkofYokogawaElectricCorporation.
• Theregisteredtrademarksortrademarksoftherespectivecompaniesin
the text do not bear the mark of TM or ®.

1-4
<Introduction>
IM 01W06D01-01EN
1.1 Safe Use of This Product
• Usersofexplosionprotectedinstrumentsshouldreferrstto“2.6Explosion
Protected Instrument”.
• Theuseofthisinstrumentisrestrictedtothosewhohavereceived
appropriate training for the device.
• Takecarenottocreatesparkswhenaccessingtheinstrumentorperipheral
devicesinahazardouslocation.
• Repairormodicationtothisinstrumentbycustomerwillcausea
malfunctionofexplosionprotectfunctionandhazardoussituation.Ifyou
needtorepairormodication,pleasecontactthenearestYokogawaoce.
1.2 Radio Waves
Thisproductisdesignatedasacerticationofconstructiontypeasawireless
facilityfor800MHzbandand900MHzbandlow-powerdatacommunication
system of the Radio Act.
Refer to “7.6 Regulatory Compliance Statements” for detail.
• AreaCode2:RegionalparameterisEU868andfrequencyis863to
870MHz*1.
• AreaCode3:RegionalparameterisUS915andfrequencyis902to
928MHz*2.
• AreaCode4:RegionalparameterisAS923andfrequencyis919to
925MHz*2.
*1: SwedenandGreecedonotallowfulluseofthe863to870MHzband.
Detail of the restrictions, refer to EC Decision 2006/771/EC (as amended).
*2: Availablefrequencybandsvarydependingonthecountry.

1-5
<Introduction>
IM 01W06D01-01EN
IMPORTANT
• Duetothedesignatedcerticationofconstructiontype,usersmaybe
subjecttolegalpunishmentincaseofdisassemblingormodifyingthis
product.
• PreventinginterferencewithotherwirelessstationsIndustrial,scientic,
andmedicalequipment,aswellaslocalwirelessstations(license
required)andspeciclowpowerwirelessstations(licensenotrequired)
foridentifyingmobileobjectsusedinfactoryproductionlines,usethe
samefrequencybandasthisproduct.
• Checkthatlocalwirelessstationsandspeciclow-powerwireless
stations are not being used in the vicinity before using this product.
• Ifthisproductcausesradiointerferenceinalocalwirelessstation,stop
the emission of radio waves immediately. For details on how to prevent
radiointerference,contactourserviceoce.
1.3 Warranty
• Thewarrantyshallcovertheperiodnotedonthequotationpresentedtothe
purchaser at the time of purchase. Problems occurring during the warranty
period shall basically be repaired free of change.
• Ifanyproblemsareexperiencedwiththisproduct,thecustomershould
contact the Yokogawa representative from which this product was
purchasedorthenearestYokogawaoce.
• Ifaproblemariseswiththisproduct,pleaseinformusofthenatureof
the problem and the circumstances under which it developed, including
themodelspecicationandserialnumber.Anydiagrams,dataandother
information you can include in your communication will also be helpful.
• Thepartyresponsibleforthecostofxingtheproblemshallbedetermined
by Yokogawa following an investigation conducted by Yokogawa.

1-6
<Introduction>
IM 01W06D01-01EN
nThe purchaser shall bear the responsibility for
repair costs, even during the warranty period, if the
malfunction is due to:
• Improperand/orinadequatemaintenancebythepurchaser.
• Malfunctionordamageduetoafailuretohandle,use,orstorethisproduct
inaccordancewiththedesignspecications.
• Useofthisproductinquestioninalocationnotconformingtothestandards
speciedbyYokogawa,orduetoimpropermaintenanceoftheinstallation
location.
• Failureordamageduetomodicationorrepairbyanypartyexcept
Yokogawa or an approved representative of Yokogawa.
• Malfunctionordamagefromimproperrelocationofthisproductinquestion
after delivery.
• Reasonofforcemajeuresuchasres,earthquakes,storms/oods,
thunder/lightening, or other natural disasters, or disturbances, riots,
warfare, or radioactive contamination.

2-1
<Notes on Handling>
IM 01W06D01-01EN
2. Notes on Handling
The XS110A is fully factory-tested before shipment. When the XS110A is
delivered, check the appearance for damage.
Thissectiondescribestheprecautionsrequiredtohandlethisproduct.Before
use, read this section thoroughly. For information about other items, refer to the
relevant sections.
2.1 ChecktheModelandSpecications
Themodelnameandspecicationsarewrittenon
the nameplate attached to the case. Verify that the
specicationindicatedinthe“ModelandSuxCode”in
GeneralSpecications“GS01W06D01-01EN”complies
withthespecicationswrittenontheordersheet.
2.2 Transport
To prevent damage while in transit, leave the XS110A in the original shipping
container until it reaches the installation site.
2.3 Storage
When an extended storage period is expected, observe the following
precautions.
(1) Chooseastoragelocationthatsatisesthefollowingrequirements.
• Alocationthatisnotexposedtorainorwater.
• Alocationsubjecttoaminimumofvibrationorimpact.
• Thefollowingtemperatureandhumidityrangearerecommended.
- Temperature: –40 to 85°C (–40 to 185°F)
- Humidity: 0 to 100% RH (non-condensation)
(2) When storing the XS110A, repack it carefully in the packaging that it was
originally shipped with.
(3) Preferably remove the batteries for storage. For maximum battery life, the
storage temperature should not exceed 30°C.
F01.ai
XS110A

2-2
<Notes on Handling>
IM 01W06D01-01EN
NOTE
When storing this product over a long period, it is recommended to put
the instrument in OFF Mode to conserve the battery. For details on how to
switch to OFF Mode, refer to “IM 01W06C01-01EN”.
2.4 Selecting the Installation Location
This product is designed to withstand severe environmental conditions.
However, to ensure that it will provide years of stable and accurate
performance, take the following precautions when selecting the installation
location.
nWireless Communication
Install where are no obstacles for radio waves such as walls or pipes around
the product as possible.
nAmbient Temperature
Avoidlocationssubjecttowidetemperaturevariationsorasignicant
temperature gradient. If the location is exposed to radiant heat from plant
equipment,provideadequatethermalinsulationand/orventilation.
nAmbient Atmospheric
Do not install the product in a location with a corrosive atmosphere. If this
cannotbeavoided,ensurethereisadequateventilation.
nShock and Vibration
It is designed to be resistant to shock and vibration. However, it is
recommendedthattheXS110Abeinstalledinalocationthatissubjecttoa
minimum amount of impact and vibration.

2-3
<Notes on Handling>
IM 01W06D01-01EN
2.5 Restrictions on Use of Radio Transceivers
IMPORTANT
Althoughthisproducthasbeendesignedtoresisthighfrequencyelectrical
noise, if a radio transceiver is used near this product or its external wiring,
thisproductmaybeaectedbyhighfrequencynoisepickup.Totestthis,
start from a distance of several meters and slowly approach this product
with the transceiver while observing the measurement loop for noise
eects.Thereafterusethetransceiveroutsidetherangewherethenoise
eectswererstobserved.
2.6 Explosion Protected Instrument
2.6.1 ATEX Intrinsic Safety
Technical data:
• Certicatenumber:DEKRA20ATEX0024X
• Applicablestandards:ENIEC60079-0:2018,EN60079-11:2012
• Exmarking: II 2 G Ex ib IIC T4 Gb
• Ambienttemperature:–40to75°C(–40to167°F)*
*:Additionally,limitedbytheambienttemperaturerangeoftheequipmentconnectedtoXS110A.
• Electricalparameters:
Connector
Uo=6.88V,Io=1.54A,Po=0.3W,Co=10μF,Lo=3μH
• Enclosure:IP66/IP67whenaccordancewithEN60529whencombined
withcertiedequipment.
Certicationinformation:
WARNING
Amodicationoftheequipmentwouldnolongercomplywiththe
constructiondescribedinthecerticatedocumentation.

2-4
<Notes on Handling>
IM 01W06D01-01EN
Control drawing:
F02.ai
XS110A
Wireless communication module
Hazardous Location
IS Apparatus
Uo: 6.88 V
Io: 1.54 A
Po: 0.3 W
Co: 10 µF
Lo: 3 µH
Ui ≥ Uo
Ii ≥ Io
Pi ≥ Po
Ci ≤ Co
Li ≤ Lo
20
Connector
Specicconditionsofuse:
Precautionsshallbetakentominimizetheriskfromelectrostaticdischargeof
non-metallic parts.
WARNING
• POTENTIALELECTROSTATICCHARGINGHAZARD–SEE
INSTRUCTIONS
• DONOTOPENWHENANEXPLOSIVEATMOSPHEREISPRESENT
• USEONLYSPECIFIEDBATTERY–SEEINSTRUCTIONS
Installation:
TheequipmentmustbeinstalledinaccordancewithEN60079-14,local
requirements,andthecontroldrawing.

2-5
<Notes on Handling>
IM 01W06D01-01EN
Operation:
WARNING
• Whentheequipmentisusedinhazardouslocations,avoidanyactions
which generate electrostatic charges, such as rubbing with a dry cloth.
• WhenusingSushiSensorAPPtotheexplosionprotectedinstrument,
the Android device must comply with the following.
WhenusingtheNFClinkinanon-hazardousarea,themaximum
magneticeldstrengthgeneratedbytheAndroiddeviceis18[A/m
(r.m.s.)] or less (Compliant with ISO / IEC 14443).
WhenusingNFClinkinahazardousarea,onlyAndroiddevices
conrmedbyYokogawaElectricCorporationcanbeused.
If additional information and approvals for Android device are
required,contactaYokogawarepresentative.
Maintenance and repair:
WARNING
OnlypersonnelauthorizedbyYokogawaElectricCorporationcanrepair
theequipment.
Replacing the Battery:
WARNING
Be sure to replace the battery in a safe location. Doing so in an explosive
area could cause an explosion.
Use the following batteries.
TL-5930/S,SL-2780/S(Tadiran)orSB-D02(Vitzrocell)

2-6
<Notes on Handling>
IM 01W06D01-01EN
2.6.2 IECEx Intrinsic Safety
Technical data:
• Certicatenumber:IECExDEK19.0027X
• ApplicationStandard:IEC60079-0Ed.7.0(2017),
IEC60079-11Ed.6.0(2011)
• EXmarking:ExibIICT4Gb
• Ambienttemperature:–40to75°C(–40to167°F)*
*:Additionally,limitedbytheambienttemperaturerangeoftheequipmentconnectedtoXS110A.
• Electricalparameters:
Connector
Uo=6.88V,Io=1.54A,Po=0.3W,Co=10μF,Lo=3μH
• Enclosure:IP66/IP67whenaccordancewithIEC60529whencombined
withcertiedequipment.
Certicationinformation:
WARNING
Amodicationoftheequipmentwouldnolongercomplywiththe
constructiondescribedinthecerticatedocumentation.
Control drawing:
F03.ai
XS110A
Wireless communication module
Hazardous Location
IS Apparatus
Uo: 6.88 V
Io: 1.54 A
Po: 0.3 W
Co: 10 µF
Lo: 3 µH
Ui ≥ Uo
Ii ≥ Io
Pi ≥ Po
Ci ≤ Co
Li ≤ Lo
20
Connector

2-7
<Notes on Handling>
IM 01W06D01-01EN
Specicconditionsofuse:
Precautionsshallbetakentominimizetheriskfromelectrostaticdischargeof
non-metallic parts.
WARNING
• POTENTIALELECTROSTATICCHARGINGHAZARD–SEE
INSTRUCTIONS
• DONOTOPENWHENANEXPLOSIVEATMOSPHEREISPRESENT
• USEONLYSPECIFIEDBATTERY–SEEINSTRUCTIONS
Installation:
TheequipmentmustbeinstalledinaccordancewithIEC60079-14,local
requirements,andthecontroldrawing.
Operation:
WARNING
• Whentheequipmentisusedinhazardouslocations,avoidanyactions
which generate electrostatic charges, such as rubbing with a dry cloth.
• WhenusingSushiSensorAPPtosettheparameteroftheexplosion
protected instrument, the Android device must comply with the
following.
WhenusingtheNFClinkinanon-hazardousarea,themaximum
magneticeldstrengthgeneratedbytheAndroiddeviceis18[A/m
(r.m.s.)] or less (Compliant with ISO / IEC 14443).
WhenusingNFClinkinahazardousarea,onlyAndroiddevices
conrmedbyYokogawaElectricCorporationcanbeused.
If additional information and approvals for Android device are
required,contactaYokogawarepresentative.

2-8
<Notes on Handling>
IM 01W06D01-01EN
Maintenance and repair:
WARNING
OnlypersonnelauthorizedbyYokogawaElectricCorporationcanrepair
theequipment.
Replacing the Battery:
WARNING
Be sure to replace the battery in a safe location. Doing so in an explosive
area could cause an explosion.
Use the following batteries.
TL-5930/S,SL-2780/S(Tadiran)orSB-D02(Vitzrocell)

3-1
<Component Names>
IM 01W06D01-01EN
3. Component Names
Nameplate
Strap
hole
Battery holder
Battery holder
fixing screw
Cable
F04.ai
NFC
interface
Measurement
Module
mounting
screw
Case
Main
body
Front Back
Interior

4-1
<Installation>
IM 01W06D01-01EN
4. Installation
The XS110A does not include batteries when shipped from the factory. Install
the battery to the XS110A according to the procedure in Section 6.1. After
installing the battery, mount the XS110A on the Measurement Module. Refer to
the User’s Manual of the Measurement Module connected to the XS110A for
installation precautions.
RefertoChapter7"GeneralSpecications"fortheambientconditionsofthe
installation site.

5-1
<Operation>
IM 01W06D01-01EN
5. Operation
To perform the setting and status check of the product, use an Android device
with the NFC interface. Download Sushi Sensor App from Google Play.
Sushi Sensor App provides the following functions.
• Networksetting
• Sensorsetting
• Statuscheckofcommunication,sensor,batterylife,etc.
• SwitchtoOFFMode
For details, refer to “IM 01W06C01-01EN”.
CheckthermwareversionofMeasurementModulewithSushiSensorApp
andupdateittothelatestrmwarebeforeuse.

6-1
<Maintenance>
IM 01W06D01-01EN
6. Maintenance
6.1 Replacing the Battery
The XS110A can be replaced with a new battery. The XS110A does not include
batteries when shipped from the factory. Install the battery in the XS110A
according to the procedure in this section. If the XS110A is installed on the
Measurement Module, remove the XS110A according to the user manual of
the Measurement Module. Refer to 6.2 for the battery that can be mounted on
the XS110A.
Other manuals for XS110A
1
Table of contents
Other YOKOGAWA Wireless Module manuals