YOSensi YO Pure Pro User manual

YO Pure Pro
User guide v1.3

YO Pure Pro User guide v1.3
page 2/42
Release notes
Released
Version
Key changes
05.09.2022
1.0
Initial release.
31.01.2022
1.1
Parameter description changed, overview description
changed, added new figure describing threshold of
measurements. Added configuration instructions using
Yosensi Management Platform for firmware 3.4.0 and newer.
Changed chart for CO sensor.
26.04.2023
1.2
Minor layout changes, text errors fixed, changed chart for
CO sensor – Figure 6, improved readability, added PMx
sensor marking on Figure 1, Measured Values descriptions
changed, changeable sensor information added and possible
senstype parameter value fixed, Figure 25, 22, 19 update,
new device parameters (v3.3.0).
25.10.2023
1.3
Added configuration with Yosensi Mobile App.
www.yosensi.io

YO Pure Pro User guide v1.3
page 3/42
Content
Release notes 2
Content 3
Product description 4
Overview 4
Physical interfaces 6
LEDs 6
Buttons 6
USB-C 6
Specifications 7
Physical 7
Operating conditions 8
Measured values 9
PM2.5, PM4 and PM10 10
CO sensor 10
CO2 sensor 11
TVOC sensor 11
Atmospheric Pressure 12
Illuminance 12
Temperature and relative humidity 13
Sound Pressure Level 14
Installation 15
Package contents 15
Safety precautions 15
Installation guide 16
Operation 22
IoT system components 22
Device configuration 23
Configurable parameters 23
Parameter descriptions 27
Outlier detection mechanism 27
Configuration via CLI 30
Configuration node via Yosensi Management platform 31
Configuration node with Yosensi mobile app 32
Connecting node with network 33
Yosensi Management Platform configuration 33
Adding a node manually 33
Adding node via Bluetooth 36
Payload description 37
Compliance statements 40
www.yosensi.io

YO Pure Pro User guide v1.3
page 5/42
Product description
Overview
The YO Pure Pro device measures indoor environmental conditions, including concentrations of
particulate matter (PM2.5, PM4, PM10), carbon monoxide (CO), carbon dioxide (CO2), and total
volatile organic compounds (TVOC). The included sensors also monitor atmospheric pressure,
illumination, temperature, humidity, and noise level. YO Pure Pro may be ordered with the default CO
sensor or customised to measure instead 03, ETOH, H2S, SO2, or NO2.
Figure 1 Device top view.
www.yosensi.io

YO Pure Pro User guide v1.3
page 6/42
Figure 2 Device side views.
Device sticker placed on the bottom of the device enclosure contains information about model,
version, LoRaWAN region and 3 parameters important in case of device identification and
configuration:
-DEV EUI: 64-bit unique device identifier in a LoRaWAN network,
-DEV ADDR: address required to connect via ABP activation type to LoRaWAN,
-BLE MAC: bluetooth physical address.
Figure 3 Device sticker.
www.yosensi.io

YO Pure Pro User guide v1.3
page 7/42
Physical interfaces
LEDs
YO Pure Pro is equipped with RGBW LED to indicate the operating status and also battery charging
diode – both placed next to the USB-C connector (see Figure 2).
DIODE STATUES INTERPRETATION
BEHAVIOUR
COLOUR
DEVICE STATUS
Single flash
Green
General: device is working correctly (power and memory).
Single flash
Red
General: device is working incorrectly (power and memory).
LoRaWAN communication: failed to receive an
acknowledgement from LoRaWAN Server within specified
timeout.
Single flash
White
LoRaWAN communication: LoRaWAN frame sent\confirmation
from LoRaWAN Server after receiving the frame.
Slow flashing
Blue
BLE communication: connection to the device via BLE
(configuration).
Rapid flashing
Blue
LoRaWAN communication: connecting to LoRaWAN network.
Constant
Orange
General: battery charging process in progress.
Buttons
YO Pure Pro is equipped with one reset button placed next to the RGBW LED diode (see Figure 2).
USB-C
YO Pure Pro is equipped with a USB-C connector used for powering the device placed next to the
battery charging diode (see Figure 2).
www.yosensi.io

YO Pure Pro User guide v1.3
page 8/42
Specifications
Physical
Figure 4 Dimensions of the device.
PHYSICAL SPECIFICATION
Dimensions
Height: 45 mm
Width: 130 mm
Depth: 146 mm
Colour
White
Mounting method
Horizontal
Vertical (can be screwed to the wall)
Enclosure material
ABS (FR)
Level of protection
IP40
Weight
260 g
www.yosensi.io

YO Pure Pro User guide v1.3
page 10/42
Measured values
MEASUREMENT RANGES
Parameter
Measurement range
Accuracy
PM2.5 pre-calibrated
0 to 1000 μg/m3
±10 μg/m3at 25°C
Recommended working
conditions: 10° to 40°C
(all PMx measurements)
PM4
0 to 1000 μg/m3
±25 μg/m3at 25°C
PM10
0 to 1000 μg/m3
±25 μg/m3at 25°C
CO (default)
0 to 1000 ppm
±15% of reading
Recommended working
conditions: -20°C to 40°C
(default and all optional
sensors)
SO2(optional)
0 to 20 ppm
±15% of reading
ETOH (optional)
0 to 800 ppm
±15% of reading
H2S (optional)
0 to 10 ppm
±15% of reading
NO2(optional)
0 to 20 ppm
±15% of reading
O3(optional)
0 to 5 ppm
±15% of reading
CO2
0 to 40 000 ppm
±(40 ppm+5%) from 400 ppm
to 5000 ppm
Recommended working
conditions: -10° to 60 °C
Total volatile organic
compounds (TVOC)
pre-calibrated
0 to 20 mg/m3
±15% of reading
Atmospheric pressure
10 to 1200 hPa
±1.5 hPa at 25°C
Illuminance
0 to 120 klx
±10% at 25°C
Sound Pressure Level
45 to 110 dB SPL
-42 dBV/Pa
Relative humidity
0% to 100%
±2% (20% to 80%)
Temperature
-40°C to 125°C
±0,2°C (from 5°C to 60°C )
www.yosensi.io

YO Pure Pro User guide v1.3
page 11/42
PM2.5, PM4 and PM10
The particulate matter (PM) sensor informs users about the quantity of particles in diameters equal
to or less than 2.5 μm, 4 μm, and 10 μm, respectively. Additional information about surrounding air
pollution may be obtained by analyzing these measurements.
Figure 5 Example of PM2.5 monitoring chart.
CO sensor
Monitoring the CO concentration value is considered a critical indoor environmental parameter
because of its odourless character and the potential for serious impact on human health when levels
exceed a threshold. Collected data is used to inform the proper amount of ventilation for an indoor
environment.
Figure 6 Example of CO monitoring chart.
www.yosensi.io

YO Pure Pro User guide v1.3
page 12/42
CO2sensor
Monitoring the CO2level is an important indoor environment parameter that affects human health.
High levels within a short duration can cause, for example, poor concentration, loss of attention, and
an increased heart rate.
Figure 7 Example of CO2monitoring chart.
TVOC sensor
TVOC (total volatile organic compounds) is an important indicator of indoor hygiene and air quality.
This sensor measures the amount of compounds that can affect human health and comfort.
Figure 8 Example of TVOC monitoring chart.
www.yosensi.io

YO Pure Pro User guide v1.3
page 13/42
Atmospheric Pressure
By tracking changes in atmospheric pressure it's possible to predict how the value/difference might
affect human mood.
Figure 9 Example of atmospheric pressure monitoring chart.
Illuminance
Illuminance sensor measures the value of light intensity. It can tell if there's a proper amount of light
in the room.
Figure 10 Example of illuminance monitoring chart.
www.yosensi.io

YO Pure Pro User guide v1.3
page 14/42
Temperature and relative humidity
Temperature and relative humidity are measured by sensors placed inside the device enclosure.
These measurements can be used to monitor ambient conditions (see recommended conditions).
Figure 11 Example of temperature monitoring chart.
Figure 12 Example of relative humidity monitoring chart.
www.yosensi.io

YO Pure Pro User guide v1.3
page 16/42
Installation
Package contents
1. Device (without batteries).
2. Warranty card.
3. Mounting bracket.
4. Battery lock.
5. External power supply connector.
Safety precautions
SAFETY PRECAUTIONS
SYMBOL
DESCRIPTION
Device is marked with a symbol saying that electrical and electronic products
may not be mixed with unsorted household waste. Remember that batteries
used to power the device must be treated at a specialized treatment facility.
Remember about possible electrostatic discharge when replacing battery,
connecting input or doing some other operations near inside electronics.
Battery powered (Li-ion) as this may cause damage. The equipment should be
kept in a controlled environment. CAUTION: Batteries are at risk of exploding
if incorrectly replaced. Replace only with the same or equivalent type as
recommended by the manufacturer. Discard used batteries according to the
manufacturer’s instructions.
Be careful while handling the device – dropping it may cause damage that will
affect the sensors and other electronics inside.
When installing the device on the wall remember to wear adequate protective
equipment.
To maintain the level of protection device cover screws must be properly
tightened. Device shouldn’t be used without cover.
Any actions inside the device's enclosure (excluding replacing batteries) must
be performed by trained personnel only.
Clean the device only with damp cloth.
www.yosensi.io

YO Pure Pro User guide v1.3
page 17/42
Device is intended for indoor use.
Installation guide
I. The device can be powered via a USB-C connector, an external power supply, or Li-Ion 18650
batteries.
1. USB-C connector 5 V DC. Plug the USB-C cable into the socket on the enclosure. If the
LED indicating the status of the device flashes blue, then the device is successfully
connected to the power supply.
Figure 14 Connecting USB-C cable to the device.
2. Power supply 6-30 V DC or 5-21 V AC. Remove the protective cap located at the bottom
of the enclosure to access the socket. Screw the external power supply wires into the plug of
the connector. Next, insert the connector into the socket located at the bottom of the
device. If the device status LED flashes blue, then the device is successfully connected to
the power supply.
www.yosensi.io

YO Pure Pro User guide v1.3
page 18/42
Figure 15 Connecting the power supply to the device.
3. Backup batteries Li-Ion 18650. Remove the three screws located on the bottom of the
device’s enclosure (3 out of 6 places marked with +) to remove the top of the enclosure.
Remove the battery lock and insert two Li-Ion 18650 batteries.
IMPORTANT! Align the batteries with the correct +/- polarity before re-inserting the
battery lock. When the batteries are inserted correctly, the charging process begins, and the
battery charging LED illuminates orange.
Figure 16 Inserting two batteries into the device.
II. There are 3 ways to install the device:
www.yosensi.io

YO Pure Pro User guide v1.3
page 19/42
1. Place on a desk. Install the rubber feet (installed by default) and connect the power supply.
Figure 17 Installation of the rubber feet for a desk placement.
1. Mount on a wall.
A. Screw the mounting nuts into the enclosure (see Figure 18).
Figure 18 Screw the mounting nuts into the device for a wall installation.
B. Install the mounting bracket on the wall using screws (see Figure 19). Screw the
bracket to the wall using your preferred mounting holes.
www.yosensi.io

YO Pure Pro User guide v1.3
page 20/42
C. When using a 6-30 V DC or 5-21 V AC power supply, the centre plastic circle labelled
PUSH must be snapped out of the mounting bracket before installation. Next, route
the cable through the centre hole of the bracket.
Figure 19 Install the wall-mount bracket onto the device.
D. Attach the device to the mounting bracket by first fitting the mounting nuts on the
device into the mounting holes of the bracket. Next, turn the device clockwise (see
Figure 20) until aligned to its final orientation (see Figure 21).
Figure 20 Turn the device clockwise after inserting into the bracket for mounting on a wall.
www.yosensi.io
Other manuals for YO Pure Pro
1
Table of contents
Other YOSensi Security Sensor manuals
Popular Security Sensor manuals by other brands

Theben
Theben TIMEGUARD PDSM362AB Installation & operating instructions

PCB Piezotronics
PCB Piezotronics M108A04 Installation and operating manual

SECOLink
SECOLink BK4 installation manual

System Sensor
System Sensor OSI-RIE Series manual

Wieland
Wieland Gesis KNX P CO installation manual

Varian
Varian ProStar 325 UV-Vis Service manual

Guardall
Guardall DTX 15 installation guide

hager
hager EE82 Series Setup instructions

PCB Piezotronics
PCB Piezotronics ICP W138A10/-0031 Installation and operating manual

STEINEL PROFESSIONAL
STEINEL PROFESSIONAL True Presence COM1 Information

Det-Tronics
Det-Tronics X5200 instructions

Nivel System
Nivel System RD700 DIGITAL instruction manual