Yuanxin Electric YX2000 User manual

YX3000 Senseless Vector Type Inverter Manual
- 0 -
Yuanxin Electric Tech Co., Limited
User's Guide ( Edition V4.1)
YX2000/3000/3300 Sensorless Vector Type
Inverter

YX3000 Senseless Vector Type Inverter Manual
- 1 -
Preface
Thank you for choosing Yuanxin Electric Tech CO., Limited of the YX3000.
YX3000 series vector control inverter is mainly positioned as a high-end market for OEM
customers and the specific requirements of fan and pump load applications, its flexible
design, both embedded SVC and VF control in one, can be widely used for speed control
accuracy, torque response speed, low-frequency output characteristics and other situations
with higher requirements.
This user manual supplies a detailed description of YX3000 series vector control inverter
includes product characterization, structural features, parameter setting, operation and
commissioning, inspection maintenance and other contents. Be sure to carefully read
through the safety precautions before use, and use this product on the premise that
personnel and equipment safety is ensured.
IMPORTANT NOTES
◆To illustrate the details of the products, pictures in this manual based on products with
outer casing or safety cover being removed. When using this product, please be sure to
well install outer casing or covering by the rules, and operating in accordance with the
manual contents.
◆The illustrations this manual for illustration only and may vary with different products
you have ordered.
◆The company is committed to continuous improvement of products, product features
will continue to upgrade, and the information provided is subject to change without notice.
◆If you are using have questions; please contact our regional agents or our customer
service center. Customer Service Tel: 400-88-2657
◆The company's other products please visit our website. http://www.yuanxindrive.com

YX3000 Senseless Vector Type Inverter Manual
- 2 -
Contents
Chapter 1 Safety Precautions
1.1 Safety Considerations -------------------------------------------------------------(4)
1.2 Precaution ------------------------------------------------------------------------------(8)
Chapter 2 Models and Specifications
2.1 Models -----------------------------------------------------------------------------------(12)
2.2 Specifications --------------------------------------------------------------------------(13)
2.3 Parts of Inverter -----------------------------------------------------------------------(16)
2.4 Dimensions -----------------------------------------------------------------------------(17)
2.5 Optional Parts--------------------------------------------------------------------------(24)
Chapter 3 Installation and Wire Connection
3.1 Installation -------------------------------------------------------------------------------(27)
3.2 Removing and Mounting Front Cover of Inverter-------------------------------(28)
3.3 Wire Connection -----------------------------------------------------------------------(28)
3.4 Main Circuit Wiring --------------------------------------------------------------------(29)
3.5 Basic Wiring Diagram -----------------------------------------------------------------(31)
3.6 Control Circuit Terminal Wiring -----------------------------------------------------(32)
3.7 EMC Installation Instruction ---------------------------------------------------------(39)
Chapter 4 Running of Inverter
4.1 Running of Inverter --------------------------------------------------------------------(42)
4.2 Operation and Using of the Control Panel----------------------------------------(45)
4.3 Inverter power---------------------------------------------------------------------------(53)
Chapter5 Function Parameter Table
5.1 Symbol Description --------------------------------------------------------------------(55)
5.2 Function Code Table ------------------------------------------------------------------(55)
5.3 State Monitoring Parameter Table--------------------------------------------------(73)

YX3000 Senseless Vector Type Inverter Manual
- 3 -
5.4 Terminal Monitoring State-------------------------------------------------------------(75)
Chapter 6 Function Code Description
6.1 Basic running function parameter ( P0 Group) ---------------------------------(76)
6.2 Frequency Setting Function Parameter (P1 Group)-- -------------------------(84)
6.3 Start/Brake Function Parameter (P2 Group)----- -------------------------------(87)
6.4 Auxiliary Running Parameter (P3 Group)----------------------- -----------------(89)
6.5 Terminal Control Function Parameter (P4 Group)------------ -----------------(98)
6.6 Protection Function Parameter (P5 Group)---------------- --------------------(114)
6.7 Fault Record Function Parameter (P6 Group)------------ --------------------(117)
6.8 Close Loop Running Control Function Parameter (P7 Group)-- ---------(118)
6.9 PLC Running Parameter (P8 Group)---------------------------- ----------------(126)
6.10 Swing Frequency Function Parameter (P9 Group)------ ------------------(131)
6.11 Vector Control Parameter (PA Group)--------------------- --------------------(135)
6.12 Factory Function Parameter (PF Group)--------------- ----------------------(137)
Chapter 7 Troubleshooting
7.1 Fault Alarm and Troubleshooting ------------------------------------------------(138)
7.2 Fault Record Search----------------------------------------------------------------(142)
7.3 Fault Reset ----------------------------------------------------------------------------(142)
Chapter 8 Preservation and Maintenance
8.1 Preservation and Maintenance --------------------------------------------------(143)
8.2 Periodic Preservation and Maintenance----------------------------------------(143)
8.3 Warranty of Inverter-----------------------------------------------------------------(144)
Chapter 9 Serial Port Communication Protocol of RS485
9.1 Communication Overview----------------------------------------------------------(145)
9.2 Communication Protocol Specification-----------------------------------------(145)
9.3 The ASCII Communication Protocol---------------------------------------------(147)

YX3000 Senseless Vector Type Inverter Manual
- 4 -
Chapter 1 Safety Precautions
Safety Precautions
Safety signs in this manual:
DANGER: indicates the situation in which the failure to follow operating requirements
may result in fire or serious personal injury or even death.
CAUTION:indicates the situation in which the failure to follow operating requirements
may cause moderate or slight injury and damage to equipment.
Users are requested to read this chapter carefully when installing, commissioning and
repairing this product and perform the operation according to safety precautions as set forth
in this chapter without fail. YUANXIN will bear no responsibility for any injury and loss as a
result of any violation operation.
1.1 Safety Considerations
The use phase
Safety class
Considerations
Before
Installation
Danger
◆Do not install the product if the package is with
water, or component is missing or broken.
◆Do not install the product if the label on the
package is not identical to that on the inverter.
Caution
◆Be careful of carrying or transportation. Risk of
devices damage.

YX3000 Senseless Vector Type Inverter Manual
- 5 -
◆Do not use damaged product or the inverters
missing component .Risk of injury.
◆Do not touch the parts of control system with
bare hands. Risk of ESD hazard.
Installation
Danger
◆Installation base shall be metal or other
non-flammable material. Risk of fire.
◆Do not install inverter in an environment
containing explosive gases, otherwise there is
danger of explosion.
◆Do not unscrew the fixing bolts, especially the
bolts with red mark.
Caution
◆Do not leave cable strips or screws in the
inverter. Risk of inverter damage.
◆Install the product at the place with less
vibration and no direct sunlight.
◆Consider the installation space for cooling
purpose when two or more inverters are placed in
the same cabinet.
Wiring
Danger
◆Wiring must be performed by authorized and
qualified personnel. Risk of danger.
◆Circuit-breaker should be installed between
inverter and the mains. Risk of fire.
◆Make sure the input power supply has been
completely disconnected before wiring. Failure to
comply may result in personnel injury and/or
equipment damage.
◆Since overall leakage current of this equipment

YX3000 Senseless Vector Type Inverter Manual
- 6 -
may be bigger than 3.5mA, for safety's sake, this
equipment and its associated motor must be well
grounded so as to avoid risk of electric shock.
◆Never connect the power cables to the output
terminals (U,V,W) of the AC drive. Pay attention to
the marks of the wiring terminals and ensure
correct wiring. Failure to comply will result in
damage to the AC drive.
◆Install braking resistors at terminals (P+)and
(P-or PB) only. Failure to comply may result in
equipment damage.
Caution
◆Since all adjustable frequency AC drives from
YUANXIN have been subjected to hi-pot test
before delivery, users are prohibited from
implementing such a test on this equipment.
Failure to comply may result in equipment
damage.
◆Signal wires should to the best of the possibility
be away from main power lines. If this cannot be
ensured, vertical cross-arrangement shall be
implemented, otherwise interference noise to
control signal may occur.
◆If motor cables are longer than 100m, it is
recommended output AC reactor be used. Failure
to comply may result in faults.

YX3000 Senseless Vector Type Inverter Manual
- 7 -
Before
Power-on
Danger
◆Inverter shall be power-on only after the front
cover is assembled. Risk of electrical hazard.
Caution
◆Verify that the input voltage is identical to the
rated voltage of product, correct wiring of input
terminals R, S, T or L1, L2 and output terminals U,
V, and W, wiring of inverter and its peripheral
circuits, and all wires should be in good
connection. Risk of inverter damage.
After Power-on
Danger
◆Do not open the cover after power. Rick of
electrical hazard.
◆Do not touches any input/output terminals of
inverter with bare hands. Rick of electrical hazard.
Caution
◆If auto tuning is required, be careful of personal
injury when motor is running. Risk of accident.
◆Do not change the defaults of parameters. Risk
of devices damage.
During
Operation
Danger
◆Non-professionals shall not detect signals
during operation. Risk of personal injury or device
damage.
◆Do not touch the fan or the discharging resistor
to check the temperature. Failure to comply will
result in personal burnt.
Caution
◆Prevent any foreign items from being left in the
devices during operation. Risk of device damage.
◆Do not control start/stop of inverter by ON/OFF
of contactor. Risk of device damage.

YX3000 Senseless Vector Type Inverter Manual
- 8 -
Maintenance
Danger
◆Maintenance and inspection can only be
performed by professionals. Risk of
personal injury.
◆Maintain and inspect devices after
power is off. Risk of electric hazard.
◆Repair or maintain the AC drive only ten
minutes after the AC drive is powered off.
This allows for the residual voltage in the
capacitor to discharge to a safe value.
Failure to comply will result in personal
injury.
◆All pluggable components can be
inserted or pulled out only when power has
been turned off.
◆Set and check the parameters again
after the AC drive is replaced.
1.2 Precautions
1.2.1 Motor Insulation Inspection
When the motor is used for the first time or when the motor is reused after being kept, or
when periodical inspection is performed, insulation inspection shall be conducted with motor
so as to avoid damaging the inverter because of the insulation failure of the motor windings.
The motor wires must be disconnected from the inverter during the insulation inspection. It is
recommended to use the 500V mega meter, and the insulating resistance measured shall be
5MΩ at least..
1.2.2 Motor Thermal Protection

YX3000 Senseless Vector Type Inverter Manual
- 9 -
If the motor rating does not match that of the inverter, especially when the rated power of the
inverter is higher than that of the motor, adjust motor protection parameters in the inverter or
install thermal relay to protect motor.
1.2.3 Operating with the Frequency Higher than Grid Power Frequency
Output frequency of YX3000 is 0.00Hz ~500Hz. If YX3000 is required to operate above
50.00Hz, please take the endurance of mechanical devices into consideration.
1.2.4 Mechanical Vibrations
Inverter may encounter mechanical resonance point of the load device at certain output
frequencies which can be avoided by setting the skip frequency parameters of the inverter.
1.2.5 Motor Heat and Noise
Since output voltage of inverter is PWM wave and contains a certain amount of harmonics,
so that the temperature, noise and vibration of the motor will be higher than those when the
inverter runs at grid power frequency.
1.2.6 Voltage-sensitive device or capacitor on output side of the AC drive
Do not install the capacitor for improving power factor or lightning protection
voltage-sensitive resistor on the output side of the AC drive because the output of the AC
drive is PWM wave. Otherwise, the AC drive may suffer transient overcurrent or even be
damaged.
1.2.7 Contactor at the I/O terminal of the AC drive
When a contactor is installed between the input side of the AC drive and the power supply,
the AC drive must not be started or stopped by switching the contactor on or off. If the AC
drive has to be operated by the contactor, ensure that the time interval between switching is
at least one hour since frequent charge and discharge will shorten the service life of the
capacitor inside the AC drive.
When a contactor is installed between the output side of the AC drive and the motor, do not

YX3000 Senseless Vector Type Inverter Manual
- 10 -
turn off the contactor when the AC drive is active. Otherwise, modules inside the AC drive
may be damaged.
1.2.8 Applied with the Rated Voltage
Apply YX3000 with the rated voltage. Failure to comply will damage inverter. If required, take
a transformer to boost or step-down voltage.
1.2.9 Do Not Apply a 3-Phase Input Inverter to 2-Phase Input Applications
Do not apply a 3-phase input FR inverter to 2-phase input applications. Otherwise, it will
result in faults or damage inverter.
1.2.10 Lightning Protection
YX3000 has integrated lightning over-current protection device which has certain
self-protection capacity against the lightning. Additional protection devices have to be
installed between inverter and power supply in the area where lightning occurs frequently.
1.2.11 Altitude De-rating
In places where the altitude is above 1000 m and the cooling effect reduces due to thin air,
it is necessary to de-rate the AC drive. Contact YUANXIN for technical support.
80%
90%
100%
1000 2000 3000 4000
Iout
(米)
1.2.12 some special usages

YX3000 Senseless Vector Type Inverter Manual
- 11 -
If wiring that is not described in this manual such as common DC bus is applied, contact the
agent or YUANXIN for technical support.
1.2.13 Cautions for Inverter Disposal
The electrolytic capacitors on the main circuit and PCBA may explode when they are burnt.
Emission of toxic gas may be generated when the plastic parts are burnt. Please dispose
inverter as industrial wastes.
1.2.14 Adaptable Motor
The standard adaptable motor is adaptable four-pole squirrel-cage asynchronous induction
motor or PMSM. For other types of motor, select a proper AC drive according to the rated
motor current.
The cooling fan and rotor shaft of non-variable-frequency motor are coaxial, which results in
reduced cooling effect when the rotational speed declines. If variable speed is required, add
a more powerful fan or replace it with variable-frequency motor in applications where the
motor overheats easily.
The standard parameters of the adaptable motor have been configured inside the AC drive. It
is still necessary to perform motor auto-tuning or modify the default values based on actual
conditions. Otherwise, the running result and protection performance will be affected.
The AC drive may alarm or even be damaged when short-circuit exists on cables or inside
the motor. Therefore, perform insulation short-circuit test when the motor and cables are
newly installed or during routine maintenance. During the test, make sure that the AC drive is
disconnected from the tested parts.

YX3000 Senseless Vector Type Inverter Manual
- 12 -
Chapter 2 Models and Specifications
2.1 Models
YX3000 series inverter has 2 kinds of voltage levels, 220V and 380V. The Power range is
from 0.4KW to 450KW. Models of YX3000 series are shown in Table 2-1.
Table 2-1. Models description
Voltage level
Models
Rated
capacity
(
KVA
)
Rated
output
Applicable
motor(KW)
220V
Single
phase
YX3000-2S0004G
1.1
3.0
0.4
YX3000-2S0007G
1.5
4.7
0.75
YX3000-2S0015G
2.8
7.5
1.5
YX3000-2S0022G
3.8
10.0
2.2
220V
Three
YX3000-2T0015G
3.0
7.0
1.5
YX3000-2T0022G
4.0
10.0
2.2
380V
Three
phase
YX3000-4T0007G
1.5
2.5
0.75
YX3000-4T0015G
2.5
4.0
1.5
YX3000-4T0022G
YX3000-4T0022P
3.0
6.0
2.2
YX3000-4T0037G
YX3000-4T0037P
5.9
9.6
3.7
YX3000-4T0055G
YX3000-4T0055P
8.5
14.0
5.5
YX3000-4T0075G
YX3000-4T0075P
11
17.0
7.5
YX3000-4T0110G
YX3000-4T0110P
17
25
11
YX3000-4T0150G
YX3000-4T0150P
21.7
32
15
YX3000-4T0185G
YX3000-4T0185P
25.7
39
18.5
YX3000-4T0220G
YX3000-4T0220P
29.6
45
22
YX3000-4T0300G
YX3000-4T0300P
39.5
60
30
YX3000-4T0370G
YX3000-4T0370P
49.4
75
37
YX3000-4T0450G
YX3000-4T0450P
60
91
45

YX3000 Senseless Vector Type Inverter Manual
- 13 -
YX3000-4T0550G
YX3000-4T0550P
73.7
112
55
YX3000-4T0750G
YX3000-4T0750P
99
150
75
YX3000-4T0900G
YX3000-4T0900P
116
176
90
YX3000-4T1100G
YX3000-4T1100P
138
210
110
YX3000-4T1320G
YX3000-4T1320P
167
253
132
YX3000-4T1600G
YX3000-4T1600P
200
304
160
YX3000-4T1850G
YX3000-4T1850P
234
355
187
YX3000-4T2000G
YX3000-4T2000P
248
377
200
380V
YX3000-4T2200G
YX3000-4T2200P
280
426
220
Three
YX3000-4T2500G
YX3000-4T2500P
318
474
250
YX3000-4T2800G
YX3000-4T2800P
342
520
280
YX3000-4T3150G
YX3000-4T3150P
390
600
315
YX3000-4T3500G
YX3000-4T3500P
435
660
350
YX3000-4T4000G
YX3000-4T4000P
493
750
400
YX3000-4T4500G
YX3000-4T4500P
560
850
450
2.2 Specifications
Items
Specifications
Input
Rated Voltage
Single phase220V, three phase 200V, three phase
380V;50Hz/60Hz
Range
Voltage: ±20% voltage unbalance rate:<3%; frequency:
±5%
Output
Rated voltage
0~200V/220V/380V
Frequency
range
0Hz~500Hz
Frequency
resolution
0.01Hz
Overload
ability
150% rated current for1minute, 180% rated current for3 seconds

YX3000 Senseless Vector Type Inverter Manual
- 14 -
Control function
Control
function
Modulation
modes
Optimized space voltage vector SVPWM modulation
Control mode
Sensorless vector control (with optimal low frequency
compensation)
Frequency
precision
Digital setting: The highest frequency×± 0.01% Analog
setting: The highest frequency ×±0.2%
Frequency
resolution
Digital setting: 0.01Hz; Analog setting: The highest
frequency× 0.1%
Start
frequency
0.40Hz~20.00Hz
Torque boost
Auto torque boost, manual torque boost 0.1%~30.0%
V/F curve
Five ways: constant torque V/F curve, 1 kind of user defined
V/F curve ,3 kinds of down torque curve(2.0/1.7/1.2times
the power)
Acc./Dec.
curve
Two ways: linear Acc./Dec.,S-curveAcc./Dec.;7 kinds of
Acc./Dec. time,
Time unit(minute/second) optional, max. time: 6000
minutes.
DC braking
DC braking start frequency:0~15.00Hz
braking time:0~60.0s braking current:0~80%
Energy
consuming
braking
Below 22KW drive built-in energy consuming braking unit,
external braking resistor is optional.
Jog running
Jog frequency range:0.1Hz~50.00Hz, JOG Acc./Dec. time:
0.1~60.0s
PI built-in
Easily constitute a close loop control system
Multi-stage
speed
running
Multi-stage speed running available through built-in PLC or
control terminals
Textile swing
frequency
Swing frequency available with preset and centre frequency
adjustable
Auto voltage
regulation
Keep a stable voltage automatically when the grid voltage
transients

YX3000 Senseless Vector Type Inverter Manual
- 15 -
Auto energy
saving
running
Saving energy by auto optimizing V/F curve according to the
load
Auto current
limiting
Auto current limiting to prevent frequent over current fault trip
Fixed-length
control
Inverter stops when reaches the preset length
Communicati
on
RS485 standard communication port available, support
MODBUS communication protocol of ASCII and RTU,
master-slave multi-machine interaction function available
Running
function
Running
command
channel
Control panel : control terminal :serial port :3 channels
switchable
Frequency
setting
channel
Control panel potentiometer setting: ▲、▼control panel
keys setting; Function code setting: Serial port setting;
Terminal up/down setting: Input Analog voltage setting: Input
Analog current setting: Input pulse setting; Combination ways
setting;
Above ways are switchable.
Switch input
channel
FWD/REV command: 8channels programmable switch
inputs, 35kinds of function can be set separately
Analog input
channel
4~20mA: 0-10V: 2 optional analog inputs
Analog
output
channel
4~20mA or 0~10V optional, setting frequency and output
frequency ,etc feature output
Switch/pulse
output
channel
Programmable open collector output: relay output :0~20KHz
pulse output:
Control panel
LED digital
display
Display setting frequency, output voltage, output current, etc.
External
meter display
Display output frequency, output current, output voltage, etc.
Key lock
All the keys can be locked

YX3000 Senseless Vector Type Inverter Manual
- 16 -
Parameter
copy
Function code parameters are able to be copied between
inverters when use remote control panel。
Protection function
Overcurrentprotection:overvoltageprotection:undervoltagepro
tection:overheating protection: overload protection, etc.
Optional parts
Braking unit: remote control panel: cable: panel mounting
feet, etc.
Environment
Environment
Indoors, free from direct sunlight, dust, corrosive gas, oil mist,
steam, water dropper salt, etc
Altitude
Lower than 1000m (derating is necessary above 1000m)
Ambient
temperature
-10℃~+40℃
Humidity
<90%RH, no condensation
Vibration
Lower than 5.9m/s (0.6g)
Storage
temperature
-20℃~+60℃
Structure
Protection
level
IP20(In the selection of state display unit or the keyboard
state)
Cooling
Forced air cooling
Installation
Wall mounted; Floor mounted
2.3 Parts of Inverter
Control cable exit
Control panel
Input
Mounting hole
Air intake
Front cover
Output

YX3000 Senseless Vector Type Inverter Manual
- 17 -
2.4 Dimensions
W
H
W1
H1
D
(a)、Inverters below 7.5KW

YX3000 Senseless Vector Type Inverter Manual
- 18 -
W
W1
H
H1
D
(b)、Inverters from 11KW to 90 KW

YX3000 Senseless Vector Type Inverter Manual
- 19 -
W1
H2
H1
D
W
H
(c)、Inverters from 110KW to 250 KW
This manual suits for next models
2
Table of contents