Z-Wave AC MASTER LITE User manual

ZXT-510
AC MASTER
Lite
INSTALLATION GUIDE


1
Table of Contents
Introduction ............................................................. 2
Product Overview.................................................... 3
Key Descriptions................................................................3
Features.............................................................................4
Z-Wave Glossary...............................................................4
Get Started ............................................................. 6
Step 1 Apply Power to ZXT-510 .......................................6
Step 2 Include ZXT-510 to a Z-Wave Gateway.................6
Step 3 Setup Automatic Status Report Association to Gateway
...........................................................................................7
Step 4 Setup Air Conditioner IR code...............................7
Other Setup Options through Configuration.............14
Support for Association Groups........................................17
Reset to Factory Default..........................................18
Mounting .................................................................18
Required tools and supplies..............................................18
CAUTION.......................................................................... 18
Mounting Location Tips.....................................................19
Mounting the ZXT-510...................................................... 19
Technical Specifications...........................................20
WARRANTY............................................................21
Regulatory information............................................. 22
IC Notice .................................................................23
Warnings................................................................. 23

3
Introduction
ZXT-510, AC Master, is a Z-Wave plus compliant Z-Wave-to-IR
Bridge to control split air conditioner by receiving Z-Wave
command and translating to Infrared command. With its
comprehensive built-In and cloud-stored IR database (library).
ZXT-510 can control different brands and models of air
conditioners worldwide.
ZXT-510 is a security enabled Z-Wave plus device. A security
Enabled Z-Wave Plus Controller must be used in order to
fully utilize the product.
ZXT-510 is a Z-Wave slave device, it depends on gateway to
setup particular AC brand with correct IR code. Different
gateway has dif- ferent user interface for setup.

4
Product Overview

5
Features
•Working as a Z-Wave thermostat
•Support classic inclusion and NWI
•Built-in air conditioner IR codes, as well as cloud-based IR
code library
•IR learning back up
•Built-in temperature sensor for room temperature report
•Working on battery (1 x CR123A batteries) or USB power
•Support firmware upgrades via Over-the-air (need Gateways
support)
Z-Wave Glossary
Device or Node
Devices and nodes are all terms to describe an
indi- vidual Z-Wave device. These are all
interchangeable when setting up your Z-Wave
network.
Inclusion
Add a Z-Wave device to the network.
Exclusion
Remove a Z-Wave device from the network.
Remove
To take a device out of a group, scene or
association group while that device still exists in
the same Z-Wave network.
NetworkWide
Inclusion
(NWI)
Network Wide Inclusion (NWI) enables both end-
user friendly, Plug and Play like Z-Wave
network instal- lation as well as professional
installation scenario where the inclusion
process, in terms of time will be reduced
significantly. NWI is a feature supported by a
new frame type named Explorer which enables
the Z-Wave protocol to implement Adaptive
Source Routing.

6
Z-Wave Network
A collection of Z-Wave devices is controlled by
prima- ry and secondary controllers operating on
the same system. A Z-Wave network has its own
unique ID code so that controllers not in the
network cannot control the system.
Primary Controller
The first controller is used to set up your devices
and network. Only the Primary Controller can be
used to include or remove devices from a
network. It is rec- ommended that you mark the
primary controller for each network for ease in
modifying your network.
FLiRS Mode
FLiRS is abbreviation for "Frequently Listening
Rout- ing Slave".
FLiRS mode is targeted for battery operated
applica- tions and will enter sleep mode
frequently in order to conserve battery
consumption. The response to Z-Wave
command is not as quick as Always Listening
Device. Normally there is 1-2 seconds latency.
Always
Listening
Mode
Always Listening Mode is targeted for AC power
op- erated applications and it can act as a
repeater, which will re-transmit the RF signal to
ensure that the signal is received by its
intended destination by routing the signal
around obstacle and radio dead spots. The
response to Z-Wave command is immediate.
Association
Association is used to organize nodes in
different groups allowing the device to identify
the nodes by a group identifier. The groups can
also be copied to other devices.

7
Get Started
•Open the box
•ZXT-510 AC Master x 1pc
Step 1 Apply Power to ZXT-510
•1 x CR123A battery or micro USB
•ZXT-510 will detect the first applied power source to decide
what Z-Wave device role it will be in after included into the
Z-Wave gateway: battery= sleeping device (FLiRS mode).
USB power = always awake device (Always Listening
mode), refer to Z-Wave Glossary for more information.
•Once the ZXT-510 is included into a Z-Wave network, the
working mode (sleeping or awake) cannot be changed,
unless it is exclud- ed and re-apply the power.
•ZXT-510 can be included and operated in any Z-Wave
network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters
regardless of Vendor to increase reliability of the network.
Step 2 Include ZXT-510 to a Z-Wave Gateway
Step
Procedure / Description
Status Indicator
1
Refer to your primary controller to
enter into the Inclusion Mode or
Exclusion Mode
2
When it is prompted to enter it,
please triple click the “PROG”
button within 1 second.
Green Indicator
flashes
TWICE then
stay off

8
Notes:
1. It is recommended to perform the Remove (Exclude)
procedure before per- forming an Add (Include) procedure.
2. Red Indicator flashes TWICE then stay off to represent the
Add / Remove pro- cess failed, please repeat the above
step again.
3. If the Add (Include) process fails, try Remove (Exclude) and
/or resetting the AC Master to Factory Default and repeat
the above step.
Step 3 Setup Automatic Status Report Association to
Gateway
Please consult your Gateway suppiler for more detail. Normally,
User can ignore this step during the setup.
ZXT-510 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate
with the primary controller (Gateway/Hub/Controller) for AC
Master Status change report, refer to below for report details:
•Current Room Temperature (report in precision of 0.5°C or
1°F) (It will be according to Configuration Parameter 39
setting to decide the trigger level)
•Current Battery Level (Only apply in Low Battery Warning
hap- pened)
•Device Reset Locally Notification (Only report when the AC
Master has been triggered the RESET TO DEFAULT)
Step 4 Setup Air Conditioner IR code
•The UI of set up the IR code varies from different gateways. If
gate- ways have dedicated UI for the IR code setup please
refer to the gateway UI and ignore the below steps.
•If your gateway does not have dedicated UI for ZXT-510 IR
code setup, but support Z-Wave thermostat Command Class

9
and Con- figuration Command Class. You may refer to below
steps to setup the IR code using the configuration options in
your gateway

1
0
Step
Procedure / Description
Status Indicator
1
Refer to your primary controller
user manual, enter to the browser
page that can input the Configuration
parameter.
2
Input parameter number “27” and
parameter value (refer to brand and
code list in hardcopy or download
softcopy from our website). Then
complete the Configuration process.
Green Indicator will
turn on. If fail, Red
Indi- cator will flash
TWICE.
3
Go back to the control page of AC
Master on the gateway’s Browser
and try the function such as (Cool,
Temperature Set). If the Air
Conditioner does not respond to the
command you set on the Gate- way
(Cool, Heat, Auto, Temperature Set,
etc….), repeat Step 2 and 3 to Select
the next IR Code on the search list.
Green Indicator
flashes
ONCE
every time i f
receives a
command from
Gateway
Important Information
•Different brand or model of air conditioner has different function. For
exam- ple, some air conditioner only support temperature set from
18°C - 30°C, if user set 17°C on gateway, AC Master will not respond.
•There are more than 1 code for each brand, some does not support
Heat, if User selected a code that does not support Heat but Original
air conditioner supports Heat Function, please continue to try next
code until the correct one is selected.
•You can record down your Device Code for future reference after
setting up the AC Master correctly.
•It is not allowed to set up the IR Code when the Battery Level equal or
below to 50%
AC Device programmed to your AC Master
Code Number :

1
1
IR Code Learning
Step
Procedure / Description
Status Indicator
1
Refer to your primary controller
user manual, enter to the browser
page that can input the Configuration
parameter
2
Look up Below mapping table for
learn- ing, and decide the IR setting
you intend to learn next.
3
Open the Gateway’s Configuration
Brow- er page input parameter
number “25” and parameter value
(according to below Mapping Table),
then complete the Con- figuration
process.
Then Green
Indicator still turns
ON for in- dicating
the IR Code
Learning Start
4
Aim the Original Air Conditioner
Remote at AC Master according to
below position within 1-3cm Press
“Power ON“ button on the Original
Air Conditioner Remote. If the
Learning is failed, repeat Step 3 to
step 4 To learn next IR code, repeat
Step 2 to step 4.
Successful:
Green Indicator
flashes
TWICE
Unsuccessful:
Red Indicator
flashes TWICE.
5
Once you fi the IR Code
Learning, please go to Configuration
setting page on the Gateway
browser and input pa- rameter
number “27” and parameter value “000”
to select the dedicated AC code
number“000” for learning.
Green Indicator
flashes
ONCE
every time if
receives a
command from
Gateway

1
2
Tips
•Make sure your Original Remote is in Power OFF Status.
•Make sure your Original Remote set FAN Speed to AUTO
and FAN SWING to AUTO/ON
•Press and Hold the Power Key on Original Remote UNTIL
AC Mas- ter indicate Successful or Not.
•User need at least Learn the OFF (Parameter Value 0),
and one Temperature Mode (Parameter Value 2 ~ 28) to
complete the us- age model.
•Keep away from Incandescent Light or Direct Sunlight
during learning.
•Make sure IR Transmitter of your Original Remote alight
with learning diode of AC Master, you may also slight adjust
closer or further away the distance of two devices. Some of
Remotes the IR transmitter in hidden behind lens and may
not installed center of remote.
•Make sure the power is good on both devices, especially
the Original remote. Use Fresh Batteries in both devices
recommend- ed. ZXT-510 will not implement the learning
process if the bat- tery level Equal or below 50% .

1
3
IR Learning Mapping Table (Parameter Number 25)
Parameter
Value (Storage
Location)
Thermostat Command & IR Setting
Storage in Celsius
Unit
Storage in Fahrenheit Unit
0
OFF
OFF
1
ON (RESUME)
ON (RESUME)
2
17°C COOL
63°F COOL
3
18°C COOL
64°F COOL
4
19°C COOL
66°F or 67°F COOL
5
20°C COOL
68°F or 69°F COOL
6
21°C COOL
70°F or 71°F COOL
7
22°C COOL
72°F or 73°F COOL
8
23°C COOL
74°F or 75°F COOL
9
24°C COOL
76°F COOL
10
25°C COOL
77°F or 78°F COOL
11
26°C COOL
79°F or 80°F COOL
12
27°C COOL
81°F or 82°F COOL
13
28°C COOL
83°F or 84°F COOL
14
29°C COOL
85°F COOL
15
30°C COOL
86°F COOL
16
17°C HEAT
63°F HEAT
17
18°C HEAT
64°F HEAT
18
19°C HEAT
66°F or 67°F HEAT
19
20°C HEAT
68°F or 69°F HEAT
20
21°C HEAT
70°F or 71°F HEAT
21
22°C HEAT
72°F or 73°F HEAT

1
4
22
23°C HEAT
74°F or 75°F HEAT
23
24°C HEAT
76°F HEAT
24
25°C HEAT
77°F or 78°F HEAT
25
26°C HEAT
79°F or 80°F HEAT
26
27°C HEAT
81°F or 82°F HEAT
27
28°C HEAT
83°F or 84°F HEAT
28
29°C HEAT
85°F HEAT
29
30°C HEAT
86°F HEAT
30
DRY MODE
DRY MODE
31
AUTO MODE
AUTO MODE
32
FAN MODE
FAN MODE

1
5
Important Information
After all learning completed, User can go back to the ZXT-
510 control page on the gateway for normal operation.
•On the Gateway UI, User can only use the Temperature
range from the mapping table, OFF, ON(RESUME),
COOL, HEAT, DRY MODE, AUTO MODE and FAN MODE.
•If User only learnt ON(RESUME), OFF, or part of the
settings according to the above table, ZXT-510 will send
the learnt data to the Air Conditioner only. For example,
User only learnt ON(RE- SUME), OFF, 22°C COOL, 24°C
HEAT, ZXT-510 will not send the IR Data to Air Conditioner
if User set 27°C Cool on the gateway.
•User can still use gateway to set up Scene and Schedule
with ZXT-510. For example, to have AC turn on at 23°C
every day at 7am, 25°C at 11pm. Just make sure the set
code is learnt.
•The learning mapping table is for split Air Conditioner, which
Re- mote Control is with LCD Display. For Window type Air
Condition- er (which Remote Control is without LCD
Display), the mapping table with temperatures do not apply,
due to different type of IR Control Protocol. However, User
may still use OFF, ON(RESUME), DRY, AUTO or FAN Key
for Learning.
•(Because the POWER key on the Original Remote (without
LCD Display) is toggle, user can choose either ON key or
OFF key to learn Power key. After Learning is done, press
once to turn on the Air Conditioner if the Air Conditioner is
OFF, press once to turn OFF if the Air Conditioner is ON)

1
6
Other Setup Options through Configuration
Functions
Paramete
r
Number
Parameter Value
Size
( bytes)
Learn IR code
25 (0x19)
Default: 0x0000
range: (0x0000 to 0x20)
refer to learning mapping table
2
Check IR
Code
Learning
Status
(Read Only)
26(0x1A)
Default: 0x00
range: 0 to 4 (0x00 to 0x04)
0(0x00) : Idle - IR Channel is
idle
1(0x01) : OK - the last learning
opera- tion was completed
successfully 2(0x02) : Learning -
ZXT-510 is busy processing
previous learning request 3(0x03) :
Full –All locations are being used.
4(0x04) : The last learning
request was failed
Note:The status value 0x01 and
0x04 will be reset to 0x00 after
ZXT-510 receives a get
command to this pa- rameter.
1
Set IR Code
number
from built-in
code library
27 (0x1B)
Refer to Code Finder Webpage.
2

1
7
Set Built-
in IR
Emitter
Control
( If there are
two or more
Air Condition-
ers with the
same code
set that are
used in the
same room,
user can
disable the
built-in IR
emitter and
use the exter-
nal IR emitter
cable to
control each
air
conditioner
32 (0x20)
Default:
0xFF 0 or
255 (0x00 or
0xFF)
0(0x00): Disable
255(0xFF): Enable (Default)
1
Control Air
Conditione
r “SWING”
function
33 (0x21)
Default: 0x01
Range 0 to 1 (0x00 or
0x01) 0(0x00) : Swing
OFF
1(0x01) : Swing Auto (Default)
1

1
8
Calibrate
temperature
reading
37 (0x25)
Temperature offset
value. 0(0x00) = 0°C
(Default) 1(0x01) = 1°C
2(0x02) = 2°C
3(0x03) = 3°C
4(0x04) = 4°C
5(0x05) = 5°C
255(0xFF) = -1°C
254(0xFE) = -2°C
253(0xFD) = -3°C
252(0xFC) = -4°C
251(0xFB) = -5°C
1
Set Auto
Report
Condition
Trigger
By Room
Temperatur
e change
30 (0x1E)
0(0x00) = Disable AUTO report
func- tion (Default)
(for saving battery life)
Auto report if room temperature
is different from last report.
1(0x01) = 1°F (0.5°C)
2(0x02) = 2°F (1°C)
3(0x03) = 3°F (1.5°C)
4(0x04) = 4°F (2°C)
5(0x05) = 5°F (2.5°C)
6(0x06) = 6°F (3°C)
7(0x07) = 7°F (3.5°C)
8(0x08) = 8°F (4°C)
1
Set Auto
Report
Condition
By
Time Interval
34 (0x22)
Auto report by the following
time interval.
1(0x01) = 1 Hr
2(0x02) = 2 Hrs
3(0x03) = 3 Hrs
4(0x04) = 4 Hrs
5(0x05) = 5 Hrs
6(0x06) = 6 Hrs
7(0x07) = 7 Hrs
8(0x08) = 8 Hrs (Default)
1