Z-Wave PAT13-C User manual

Refrigerator Multi-Sensor
PAT13 -A/B/C/D
The refrigerator temperature sensor PAT13 has temperature and
door/window , 2 sensors function in one, based on Z-Wave
T
technology.
It is the Z-Wave
T
plus product, it support the security, OTA... Those
newest features of the Z-Wave
T
technology. Z-Wave
T
is a wireless
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-Wave
T
network
with other Z-Wave
T
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
The device adopt the Z-Wave
T
500 series chip, when your Z-Wave
T
network system is all made by Z-Wave
T
500 series devices. The
network system will have the advantages as below.
•Concurrent multi-channel support reduces external interference.
•Better RF range, improve about 10 meters in indoor.
•Support 100 Kbps transmit speed, speed up communication.
Specification
Rated DC3V (CR123A)
RF distance in. 40 indoor,
100 outdoor line of sight,
RF Frequency
868.40 Hz, 869.85 Hz(EU)
908.40 Hz, 916.00 Hz(US)
920.9 Hz, 921.7 Hz,
923.1 Hz(TW/SG/Thai/KR)
RF aximum Power +10dBm (Peak), -10dBm (Average)
Dimension 85(L)x 28(W)x23(H) mm
Weight 80g
IP classification IP20; indoor use
Operation temperature -10 to 40° C
Humidity 85%RH max
agnetic gap 25mm (open to close); 30mm (close
to open)
Temperature Detect Range -30 to 80°C
Cable type 28AWGx 4C OD: 3.0mm, 2 meters,
-40 to 80 °C
Specifications are subject to change and improvement without
notice.
1

Troubleshooting
Symptom Cause of Failure Recommendation
The device can not
join to Z-Wave™
network
The device may in a Z-
Wave™ network.
Exclude the device
then include again.
For Instruction to http:// www.philio-tech.com
Function Compare A/B/ C/D
Door/Window Temperature Temperature
Sensing Accuracy
PAT13-A V V ±0.3
PAT13-B V ±0.3
PAT13-C V V ±0.4
PAT13-D V ±0.4
Overview
Overview
2

Add to/Remo e from Z-Wa e
TM
Network
There are one tamper keys in the back side of the device, It can add,
remove, reset or association from the Z-Wave
T
network.
In the first time, add the device into the Z-Wave
T
network. First,
make sure the primary controller is in the add mode. And then power
on the device, just take out the insulation ylar in the back side of the
device. The device will auto start SmartStart mode. You should key in
first five digit to increment SmartStart process,or you can scan QR
code. And if it included, You will see the LED light ON one second.
Notice: Including a node ID allocated by Z-Wave
T
Controller means
“Add” or “Inclusion”. Excluding a node ID allocated by Z-Wave
T
Controller means “Remo e” or “Exclusion”.
Function Description
Add
1. Have Z-Wave
T
Controller entered inclusion mode.
2. Pressing the tamper key three times within 1.5
seconds to enter the inclusion mode.
3. After add successful, the device will wake to
receive the setting command from Z-Wave
T
Controller about 20 seconds.
Remove
1. Have Z-Wave
T
Controller entered exclusion
mode.
2. Pressing tamper key three times within 1.5
seconds to enter the exclusion mode.
Node ID has been excluded.
Reset
Notice: Use this procedure only in the e ent
that the primary controller is lost or
otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4
th
pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.
SmartStart
1. Product has a DSK string , you can key in first five
digit to increment SmartStart process,or you can
scan QR code.
Ex:mydsk
10209-46687-52248-13629-04783-07465-15776-
56519
2. SmartStart enabled products can be added into a
Z-Wave network by scanning the Z-Wave QR
Code present on the product providing SmartStart
inclusion. No further action is required and the
SmartStart product will be added automatically
within 10 minutes of minutes On in the network
vicinity.
*notice1:The QR code can be found on the device
PAT13 or on the box.
Association This machine provides two groups of nodes. Each
group can set 4 Nodes.
Group 1: Used for returned events.
Report type:
1.Notification report
2.Sensor multilevel report
3.Device Reset Locally Notification
4.Battery Report
3

Group 2: Used for returned events.
Report type:
1.Basic Set
•Failed or success in add/remove the node ID can be viewed
from Z-Wave
T
Controller.
Notice 1: Always RESET a Z-Wave
T
device before trying to add it to a
Z-Wave
T
network
Z-Wa e
TM
Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
Press the tamper key once. The device will wake-up 10 seconds.
Z-Wa e
TM
Message Report
When the Door/Window triggered the device will report the trigger
event and also report the battery status and temperature.
In default the device will using Notification Report to represent the
trigger event.
* Door/Window Report: (PA13-A)
When the Door/Window Open, the device will unsolicited to send the
report to the nodes in the lifeline group.
Notification Report (V4)
Notification Type: Access Control(0x06)
Event: Door/Window Open(0x16)
And after the Door/Window Close clear, the device will unsolicited to
send the report to the nodes in the lifeline group.
Notification Report (V4)
Notification Type: Access Control(0x06)
Event: Door/Window Close (0x17)
* Tamper Report: (PAT13-A, PAT13-B)
The tamper key pressed over 5 seconds. The device will into the alarm
state. In that state, if the tamper key be released, the device will
unsolicited to send the report to the nodes in the lifeline group.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
* Temperature Report: (PAT13-A, PAT13-B)
When the Door/Window triggered or the temperature differential over 1
Fahrenheit (in default), the device will unsolicited to send the “Sensor
ultilevel Report” to the nodes in the lifeline group.
Sensor Type: Temperature (0x01)
Note: To disable send temperature report after the flood triggered,
please setting the configuration N0.5 bit5 to 1.
*** Temperature differential report ***
This function default is enabled, to disable this function by setting the
configuration NO.21 to 0.
In the default, when the temperature is changed to plus or minus one
degree Fahrenheit (0.56 degree Celsius), the device will report
temperature information to the nodes in the lifeline group.
The device will measure the temperature in every 10 seconds. And if
4

the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will always report in each measurement.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
•Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 10.
•Door/Window state report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 11.
•Low battery report: When the battery level is too low, every 30
minutes will report once.
•Temperature report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 13.
Notice: The configuration NO. 10, 11, 13 and 14 could be setting to
zero to disable the auto report. And the configuration NO. 20 could
change the tick interval, the default value is 30, if setting to 1, that
means the minimum auto report interval will be one minute. And please
notice if setting this value to zero, that means disable all of the timing
report except the low battery detection.
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.
PS: If the device already adding to the network, the device will
broadcast a node information once.
O er The Air (OTA) Firmware Update
The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper key once to start the update.
At that time,
please don't remo e the battery
, otherwise it will
cause the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the
device. Caution: After remove the battery, please wait about 30
seconds, and then re-install the battery.
Battery Installation
When the device report the low battery message. The user should
replace the battery to new one. The battery type is CR123A, 3.0V.
The way to open the front cover please press the top position, to
release the cover.
5

Replace the new battery and install the cover back.
1. Put the front cover bottom, and press down.
2. Push the front cover top.
Z-Wa e Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the
setting still keep, don't reset to factory default. Unless the user execute
the “RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no
effect.
N
O. Name Def.
Valid
A B Description
1Basic Set
OFF Level 0 All
Setting the BASIC command value.
When the flood trigger off(0x00),
send the BASIC CC to the group 2.
2Basic Set
ON Level 0xFF All
Setting the BASIC command value.
When the flood trigger on(0xFF),
send the BASIC CC to the group 2.
5
(*
Operation
ode
All 0 04 Operation mode. Using bit to
control.
6
1
1
2

N
O. Name Def.
Valid
A B Description
)
0 Bit0: Reserve.
0 Bit1: Reserve.
0 Bit2: Disable the door/window
function.
0
Bit3: Setting the temperature
scale.
0: Fahrenheit, 1:Celsius
0 Bit4: Reserve.
0
Bit5: Disable the temperature
report after event triggered.
(1:Disable, 0:Enable)
0 Bit6: Reserve.
0 Bit7: Reserve.
7
(*
)
Customer
Function All 0 0 Customer function switch, using
bit control.
0 Bit0: Reserve.
0 Bit1: Reserve.
0 Bit2: Reserve.
0
Bit3: Disable send out BASIC OFF
after the door/window event
cleared. (1:Disable, 0:Enable)
0 Bit4: Reserve.
0 Bit5: Reserve.
0 Bit6: Disable to report battery
state when the device triggered.
(1:Disable, 0:Enable)
N
O. Name Def.
Valid
A B Description
0 Bit7: Reserve.
10
Auto
Report
Battery
Time
12 0 ~
127
The interval time for auto report
the battery level.
0 means turn off auto report.
The default value is 12. The tick
time can setting by the
configuration No.20.
11
Auto
Report
Door/Win
dow State
Time
12 0 ~
127
The interval time for auto report
the door/window state.
0 means turn off auto report
door/window state.
The default value is 12. The tick
time can setting by the
configuration No.20.
13
Auto
Report
Temperat
ure Time
12 0 ~
127
The interval time for auto report
the temperature.
0 means turn off auto report.
The default value is 12. The tick
time can setting by the
configuration No.20.
20 Auto
Report
Tick
Interval
30 0 ~
0xFF
The interval time for auto report
each tick. Setting this
configuration will effect
configuration No.10, No.13, No.14
and No.15.
Units of one minute.
Caution1:
Setting to 0 means
turn off all auto report function.
Caution2
: The value is unsigned
byte, the range is from 0x00 ~
7

N
O. Name Def.
Valid
A B Description
0xFF.
21
Temperat
ure
Differenti
al Report
10 ~
127
The temperature differential to
report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will
detect every 10 seconds.
And when the temperature is over
140 degree Fahrenheit, it will
continue report.
Z-Wa e Supported Command Class
Command Class Version Required Security Class
Z-Wave Plus Info 2 None
Battery 1 ighest granted Security Class
Notification 8 ighest granted Security Class
Association 2 ighest granted Security Class
Configuration 1 ighest granted Security Class
Manufacturer Specific 2 ighest granted Security Class
Version 3 ighest granted Security Class
Sensor Multilevel 11 ighest granted Security Class
Wake Up 2 ighest granted Security Class
Association Group Info 1 ighest granted Security Class
Powerlevel 1 ighest granted Security Class
Device Reset Locally 1 ighest granted Security Class
Security 0 1 None
Security 2 1 None
Firmware Update Meta Data 4 ighest granted Security Class
Supervision 1 None
Transport Service 2 None
Basic 1 ighest granted Security Class
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the instructions.
Choosing a Suitable Location
1. The suitable ambient temperature for the module/device is
0°C~40°C.
2. Do NOT place the module/device direct under sunlight, in a humid
place or in any location where they may contact moisture, dirt, dust.
3. Do NOT place the module/device where exists combustible
substances or any source of heat, fires, radiators, boiler etc.
8

Disposal
This marking indicates that this product should not
be disposed with other household wastes throughout
the EU. To prevent possible harm to the
environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return
your used device, please use the return and
collection systems or contact the retailer where the
product was purchased. They can take this product
for environmentally safe recycling.
Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City
24257, Taiwan(R.O.C)
w ww.philio-tech.com
FCC Interference Statement
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of
the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for
help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to
operate this equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
Warning
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
your health and well-being.
When replacing old appliances with new once, the retailer is legally
obligated to take back your old appliance for disposal at least for free
of charge.
9
This manual suits for next models
3