OPERATION
1. Make BGM signalinputfrom Aterminalwhile EMC signalinputfrom Bterminalon therearpanel. Wealso
canmake A, B togetherwithshortcircuit ifthereisnoneofappropriativeEMCamplifier.
2. Pin1 ~10 of ALARMIN”portare live terminalsof CH1~CH10 respectivelywhilepin11~25 are com.
+5 ~24V / 0V level ofalarmsignalisavailable. If ACTIVELEVEL set at High,positivesignalisvalid;
whilesetat Low,0V (grounded)signalisvalid. Everychannelwill beswitchedto Bwhilealarmsignalisfed
to ALARMIN, and the Switchindicator will flashesquickly.
3. Clickdownany Switching key toswitchchannelswhichyou want.
4. Angrounded Alarm signalwill besentoutfrom ALARMOUT”whileany alarmsignalappearson
“ALARMINPUT”.
SPECIFICATIONS
Channels 10, switchable
Inputcapacity 70 ~100 V,10 A
Outputcapacity 70 ~100 V,5 A/ CH
ALM10 CHs;+5~+24 V/ 0 according topresetting
Protection AC fuse ×1
PowerRequirement AC 220 –240 V/50~60 Hz
Dimensions 485×88×378 mm
Gross weight 6.5 kg
Netweight 5.2 kg
Specificationsaresubject tobechangedwithout notice.