manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zamel
  6. •
  7. Surge Protector
  8. •
  9. Zamel EXTA PMM-02 User manual

Zamel EXTA PMM-02 User manual

Popular Surge Protector manuals by other brands

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

Philips

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

M-system MMA instruction manual

M-system

M-system MMA instruction manual

CyberPower CSP600WSU user manual

CyberPower

CyberPower CSP600WSU user manual

UTP BALUN SP-VD08 user manual

UTP BALUN

UTP BALUN SP-VD08 user manual

ELAC ProteK PR91-W Setup guide

ELAC

ELAC ProteK PR91-W Setup guide

Tsubaki TSM4000M1 instruction manual

Tsubaki

Tsubaki TSM4000M1 instruction manual

CyberPower B1006T user manual

CyberPower

CyberPower B1006T user manual

QVS PP134C Specification sheet

QVS

QVS PP134C Specification sheet

Davis Instruments Radio Surge Protector user guide

Davis Instruments

Davis Instruments Radio Surge Protector user guide

CyberPower B300WRC1 user manual

CyberPower

CyberPower B300WRC1 user manual

M-system MGD-24 instruction manual

M-system

M-system MGD-24 instruction manual

Panamax MAX 5400-EX owner's guide

Panamax

Panamax MAX 5400-EX owner's guide

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

OBO Bettermann

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

CyberPower CSP604T user manual

CyberPower

CyberPower CSP604T user manual

CyberPower CSP706T user manual

CyberPower

CyberPower CSP706T user manual

Mitsubishi Electric LITOL LTM-125RF manual

Mitsubishi Electric

Mitsubishi Electric LITOL LTM-125RF manual

Intermatic PS3000 installation instructions

Intermatic

Intermatic PS3000 installation instructions

Siemens SICROWBAR 7VV3003 operating instructions

Siemens

Siemens SICROWBAR 7VV3003 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

POWER LIMITER PMM-02 USER’S MANUAL
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 32 210 46 65, Fax +48 32 210 80 04
www.zamel.com, e-mail: [email protected]
plik: pmm-02_instr_ext_gb | modykacja: 02.07.2019
APPEARANCE
FEATURES
TECHNICAL DATA
DESCRIPTION
PMM-02
Power input terminals: L; N
Rated supply voltage: 230 V AC
Supply voltage tolerance: -15 ÷ +10 %
Rated mains frequency: 50 / 60 Hz
Rated current load: 26 mA
Power supply indication: green LED
Power threshold setting: 0.1 ÷ 3 kW (with a rotary potentiometer)
Trip-on delay setting: 10 ÷ 90 s (with a rotary potentiometer)
Power overload indication: red LED
Power off delay: ca. 250 ms
Transmitter contact ratings: 1NO 16 A / 250 V AC1 4,000 VA
Wiring terminals: 4
Wiring size: 0.2 ÷ 2.50 mm2
Operating temperature: -20 to +60°C
Installation orientation: any
Enclosure installation type: DIN rail
Protection grade: IP20
Overvoltage category: II
Pollution class: 2
Dimensions: single module 90 × 17.5 × 66 mm
Weight: 0.077 kg
● Overload protection with a power
threshold setting.
● Electrical system overcurrent protec-
tion.
● Power supply indicator.
● Power overload indicator.
● Stepless trip-off delay setting.
● Wide power load control range.
● Resilient to transient power loads
above the set power threshold.
● Single-module enclosure.
● For installation on a DIN rail.
The PMM-02 power limiter auto-
matically isolates supply voltage from the
controlled power loads when they over-
load the set power threshold. The power
threshold can be set smoothly from 0.1
to 3 kW with a potentiometer. The power
threshold trip-on delay of the relay can be
set smoothly from 10 to 90 s.
Input (supply) terminals
Power supply indicator
Power overload indicator
Time off delay adjustment
Power threshold adjustment
Output (load) terminals
The device is designed for a
single-phase installation and
must be installed in accord-
ance with standards valid in a
particular country. Installation,
connection and control should be carried
out by a qualied electrician staff, who act
in accordance with the instruction manual
and the device functions. In case of cas-
ing dismantling, the guarantee is lost and
an electric shock may occur. Before instal-
lation make sure the connection cables
are not under voltage. The cruciform head
screwdriver 3,5 mm should be used to in-
stall the device. Improper transport, stor-
age, and use of the device inuence its
wrong functioning. It is not advisable to in-
stall the device in the following cases: if any
device part is missing or the device is dam-
aged or deformed. In case of improper func-
tioning of the device contact the producer.
CAUTION
Do not dispose of this device with
other waste! In order to avoid
harmful effects on the environment
and human health, the used device
should be stored in designated
areas. For this purpose, you can
dispose of household waste free
of charge and in any quantity to
a collection point set up, as well
as to the shop when you buy new
equipment.
CONNECTION RELAY CAPACITY
INNER DIAGRAM
TIME COURSE
MOUNTING, FUNCTIONING
1. Isolate from power the wiring system
to be connected with this product with
its circuit breaker, overcurrent device or
disconnector, as applicable.
2. Use a suitable tester to verify that the
isolated power input wiring is not live.
3. Install the PMM-02 on a DIN Rail in the
respective switchboard.
4. Connect the wiring to the terminals, see
the applicable wiring connection dia-
gram.
5. Turn on the power of the connected wir-
ing system.
6. Set the desired power threshold and
power load trip-off delay.
The control circuit limits the controlled
power load. When the total power load
demand on the controlled power line is be-
low the power threshold setting, the power
loads remain on the rated supply voltage.
When the power load demand exceeds the
power threshold setting, the power load line
is isolated from voltage (powering down the
controlled power loads). The supply voltage
is reapplied to the power loads to test the
power load value when the set trip-on delay
expires. Following this power load test, the
control circuit determines if the supply volt-
age should be reapplied or the power loads
left off. Fine-tune the power threshold after
approximately 40 minutes of operation.
APPLICATION
DIMENSIONS
PRODUCT FAMILY
WARRANTY CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
The power limiter can support a staircase lighting timer to form a timer-controlled lamp
power system with a power load limit. Having determined the power load demand in the
control system and with the power limiter’s power threshold set, the system prevents con-
nection and operation of illegal power loads with the control system. Hence, if there is a
power overload which exceeds the power threshold, the power limiter isolates the supply
voltage from the controlled power line and periodically retest the power demand for com-
pliance with the power threshold setting.
The PMM-02 is a model from the PMX range
of power limiters.
PMM-02 ASM-01
PMX - 02
Product version
Product type code
Enclosure type:
M – single-module
H – water-tight
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover:
a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products;
c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct
operation of products sold;
d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable;
e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy be-
tween the goods and the contract.
10s ÷ 90s 10s ÷ 90s 10s ÷ 90s
0,25s
0,25s
PMM-02 ASM-01