Zip 94574 User manual

805280 v1.10 04.20 Filter Mixer Tap_AU Page 1 of 8
Installation instructions
Zip
Filter Mixer Tap
AFFIX PRODUCT LABEL HERE

Page 2 of 8 805280 v1.10 04.20 Filter Mixer Tap_AU
Install the Filter
The filter (A) should be mounted as close as
possible to the front of the cupboard, to allow for
ready and easy access during filter changes.
1. Usually the side of the cupboard, near the door, is
most suitable.
2. Using the two screws provided, screw the filter
head to the inside of the cupboard, allowing
260mm minimum between the underside of the
filtration head and any obstructions (shelves, etc.)
3. Write the installation date on the filter cartridge.
4. Align the tabs of the filter cartridge with the
filter housing and insert it into the socket. Turn the
cartridge a quarter turn to the right until it stops
and locks into position. See page 5.
5. Check correct direction of flow on the filter head.
Install the plumbing fittings
Refer to Fig.2. Connect the 1/2” tee piece to the
cold water supply.
Fit the two 1/2” nipples to the tee piece.
Connect the 350kPa PLV/double non-return valve
to one nipple. NOTE: The flow direction arrow is
shown on the body of the valve.
Fit the connector and strainer to the other nipple.
Check the mesh strainer is orientated as per fig.2.
Fit a connector and strainer to the hot water supply.
Apply plumbing tape where required.
Read these Warnings First
Installation Instructions
• Please read all installation requirements, installation procedures and precautions before installing
any Zip Filter Mixer Tap.
• Never attempt to install any Zip Filter Mixer Tap without reading all of the applicable instructions.
• These products ares not intended for use by persons (Including Children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliances by a person responsible for their safety.
• Children should be supervised to ensure they do not play with the product.
• The product is for indoor use only and must not be exposed to the elements of nature.
• All plumbing connections must be made in accordance with AS/NZS3500.
• Before installing, ensure there is cold water supply with a minimum working pressure of 70 kPa and
a maximum working pressure of 700 kPa. (A 350 kPa limiting pressure valve is supplied)
• Cold water supplied must not exceed 38°C.
• Hot water supplied to the mixer must not exceed 70°C.
A
Fig.1
Stem-ended braided
hose to filter
PLV valve
1/2” nipple
1/2” Tee piece
1/2” nipple
Blue braided
hose to tap
Connector & strainer
Isolation valve to
cold water supply
Fig.2
Red braided
hose to tap
Connector &
strainer
Isolation valve
to hot water
supply

805280 v1.10 04.20 Filter Mixer Tap_AU Page 3 of 8
Install the Filter Mixer Tap
1. Position the Filter Mixer Tap at the back of the sink where there is a
minimum 45 mm wide flat area. Make sure the selected position allows the
spout to overhang the sink bowl.
The cutout size is 35 mm. Mark the centre of the new filter mixer tap
position on the sink with a centre punch.
2. Drill out the centre of the hole to allow the screw of a sheet metal
punch to pass through the sink. Use a 35 mm sheet metal hole punch to
neatly open up the hole.
3. Remove the nut and washer from the base of the Filter Mixer Tap, and
pass the hoses through the hole until the Filter Mixer Tap sits upright
within the hole. When fitting to a thin work surface, use the white plastic
stabilising clamp supplied, to improve the support of the tap.
4. Orientate the Filter Mixer Tap so that the activating levers are parallel to
the wall of the kitchen. Slide on the washer and nut from beneath the sink,
and tighten the nut to secure the Filter Mixer Tap firmly into place.
5. One blue braided and one red braided hose hangs from the bottom of
the Filter Mixer Tap. The blue braided hose connects to the tee piece via the
connector and strainer, which is connected to the mains isolation valve for
cold water, see Fig.3. The red braided hose connects to the mains isolation
valve for hot water, via a second connector and strainer.
6. Screw the brass connector with JG fitting into the remaining outlet on the
bottom of the mixer tap.
7. Connect one of the stem-ended braided hose from the PLV valve to the
inlet of the filter head, see Fig.4.
8. Connect the other stem-ended braided hose from the outlet of the filter
head to the straight JG connector at the bottom of the Filter Mixer Tap (see
Fig.3 & Fig.4).
Take care when bending braided hoses, to prevent kinking or crushing on a
bend. Please be careful to ensure the colour and connection of the braided
hoses on the Filter Mixer Tap are correct.
Do not connect the hoses in any other arrangement than that described
here. The filter cartridge and the Filter Mixer Tap have directional flow
connections that will not work if connected incorrectly. Incorrect
installation will void any product warranty.
NOTE: the flow direction of the filter housing is indicated on the filter
housing, see Fig.4.
John Guest fittings
Insertion and removal details for JG fittings using plastic tubing.
1. Cut the tube squarely with a sharp knife or tube cutter. Shake out and
remove any swarf or debris.
2. Push this end of the blue tube firmly into the John Guest socket on the
(lower) outlet side of the filter head. It must push in at least 10 mm.
3. Test the connection by trying to pull the tube out. If it comes out, re-
insert it so that it won’t come out when pulled against.
4. To remove the tube, press the collet into the fitting and at the same time
pull back on the tube.
Installation Instructions
Fig.5
Note: the direction arrows are
marked on the filter head.
Inlet
Fig.4
Outlet
Blue braided hose
Isolation valve -
cold water mains
Red braided hose
Isolation valve -
hot water supply
Stem-ended
braided hoses
Fig.3

Page 4 of 8 805280 v1.10 04.20 Filter Mixer Tap_AU
Installation Instructions
Fill the system
1. Turn on the water supply. Check the connections for leaks. Repair
any found.
The filter and tubing are full of air until purged, and the filter
cartridge requires flushing when first installed.
2. Open the Filter Water lever on the Filter Mixer Tap for a minimum
of five minutes, until all of the air has been purged from the system,
and the filter cartridge has time to become fully flushed (10L).
Every time the filter cartridge is replaced, repeat this procedure of a
five minute flush to flush the new cartridge properly.
NOTE: When flushing the system, some black particles may be
released into the water. This is normal. The water will become clear
after the first few litres.
Open and flush the cold and hot water supply of the mixer tap.
Complete the installation
Leave these instructions with client.
Issue Cause Recommended solution
No water at outlets Water not connected Connect and turn on water
Poor flow at outlet Blocked filter Replace filter
Troubleshooting
All service work must only be carried out by a suitably qualified and experienced service person.
Before calling for service, check the water supply is turned ‘ON’ and OK.
Call Zip in Australia on 1800 ZIP TAP (1800 947 827) for assistance, service, spare parts or enquiries.
Service
Cleaning
Never use strong, corrosive or abrasive cleaning materials on the Zip Filter
Mixer Tap. Wipe the outer surfaces clean with a sponge or a soft cloth using a
mild soap and water.
Filter Water
Lever
Mixer Lever
Fig.6

805280 v1.10 04.20 Filter Mixer Tap_AU Page 5 of 8
Filter Replacement
Operation
In the upright position, the tap is off.
For filtered water, rotate filtered water lever 90° forward as
shown in Fig.9.
Filtered water will be dispensed (within the rated capacity for)
as long as you rotate the lever.
For mixed water, first open the Mixer by swinging the lever 25°
away from the centre, then rotate 45° forward or reverse from
vertical axis.
Water will continue to flow until the lever is returned to the
upright position.
FILTER CARTRIDGE
REPLACEMENT
1. ROTATE
2. PULL DOWN
1. INSERT
2. ROTATE
REMOVE FILTER
INSERT FILTER
Not changing cartridges when required may cause the water to become
biologically unsafe. If the Filter Mixer Tap has not been used for more
than 12 hours, thoroughly flush water through.
For safe operation, the filter cartridge should be replaced at least every 6-12
months, or earlier if you notice a persistent reduction in water pressure from
the tap, or an unpleasant taste or odour in the water. Use only a Zip filter
cartridge to match that of your Filter Mixer Tap. Replacement cartridges can
be obtained through plumbing suppliers or directly from Zip.
Replacing a Zip Filtration cartridge is as easy as 1-2-3.
1. Unplug the old cartridge
2. Plug in the new cartridge.
3. Purge the filter system by flipping the Filter Mixer Tap lever open (on) for a
few minutes until the water runs clear (10 litres).
High sediment water areas
Zip Filter Mixer Tap 94574 is a single filter system suitable for areas in which
water supply sediment is not a problem. In areas with heavy sediment
contamination, you may wish to replace your 0.2 micron filter with a 3
micron filter, at first filter change. Refer to page 7 for cartridge kit numbers.
Fig.7
Fig.8
Fig.9
1. swing the
lever 25°
away from
the cetre
2. rotate 45°
forward or
reverse

Page 6 of 8 805280 v1.10 04.20 Filter Mixer Tap_AU
Filter Performance Data - 0.2 Micron
* The term “bacteriostatic” indicates that the
system limits the passage or growth of bacteria
that may already exist in the incoming water. It
does not mean that water leaving the system is
safer to drink than water entering the system.
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm at least 10,000
particles / mL 6,433,333/L ≥ 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L 99.9% /
<1/100 L 99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000 AS/NZS 3497
WM-0350001
Global-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm at least 10,000
particles / mL 6,433,333/L ≥ 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L 99.9% /
<1/100 L 99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi (0.7 - 8.6 bar), non-
shock
• Temperature: 35 -100°F (2-38°C)
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm at least 10,000
particles / mL 6,433,333/L ≥ 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L 99.9% /
<1/100 L 99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000 AS/NZS 3497
WM-0350001
Global-Mark.com.au
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified in NSF/ANSI Standard 42 and 53.
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO.42 - STANDARD NO.53 -
AESTHETIC EFFECTS HEALTH EFFECTS
Bacteriostatic Effects Chemical Reduction
Chemical Reduction Lead
Taste & Odor Mechanical Filtration
Chlorine Cyst
Mechanical Filtration
Nominal Particulate Class I
AS/NZS 3497
WM -0350001WM -0350001
Global-Mark.com.auGlobal-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm at least 10,000
particles / mL 6,433,333/L ≥ 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L 99.9% /
<1/100 L 99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000 AS/NZS 3497
WM-0350001
Global-Mark.com.au
Model Flow
Rate
Capacity Cartridge
Kit
0.2mic MicroPurity
Filter 1S
3.75 Lpm 4163 L 93701
0.2mic MicroPurity
filter 1.5S
5.678 Lpm 6813 L 93702
0.2mic MicroPurity
Filter 2S
5.678 Lpm 9463 L 93704

805280 v1.10 04.20 Filter Mixer Tap_AU Page 7 of 8
Filter Performance Data - 3 Micron
* The term “bacteriostatic” indicates that the
system limits the passage or growth of bacteria
that may already exist in the incoming water. It
does not mean that water leaving the system is
safer to drink than water entering the system.
It is essential that the manufacture’s recommended installation, maintenance and filter replacement requirements be carried
out for the product to perform as advertised. See installation Manual for details.
NOTE: While the testing was performed under standard laboratory conditions, actual performance may vary.
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 for the reduction of
the substances listed below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 90.6%
Particulate Class II
particles 1 to <5μm at least 10,000
particles / mL ≥ 85% 97.1%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
*Tested using flow rate = 1.0 gpm; pressure = 60 ± 3 psig; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act /
New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1.5Z3S, ZENITH 1.5NZ3S, BIRKO 1.5B3S, ZIP 2Z3S,
ZENITH 2NZ3S
System Tested and Certified by NSF International
against NSF/ANSI Standard 42 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Filtration
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class II
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless
II(a) and II(b) are passed.
N/A
III Particulate Reduction Reduces cloudiness. N/A
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead N/A
Legend: = Pass N/A = Not Applicable
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down
• Use minimum length of tubing possible
• Flush to drain for 5 minutes at full flow
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi (0.7 - 8.6 bar),
non-shock
• Temperature: 35 -100°F (2-38°C)
MODEL Flow Rate (Lpm) Capacity
1.5Z3-S 3.75 Lpm 13248 L
2Z3-S 5.678 Lpm 17034 L
1.5NZ3-S 3.75 Lpm 13248 L
2NZ3-S 5.678 Lpm 17034 L
1.5B3-S 3.75 Lpm 13248 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when
shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or
of unknown quality without adequate disinfection before or
after the system.
• The contaminants or other substances removed or reduced
by this water treatment system are not necessarily in your
water.
• Check for compliance with state and local laws
and regulations.
• Tested under standard laboratory conditions as
specified above. Actual performance may vary
depending on influent water conditions.
The term "bacteriostatic" indicates that the system limits
the passage or growth of bacteria that may already exist in
the incoming water. It does not mean that water leaving the
system is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000 AS/NZS 3497
WM-0350051
Global-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm at least 10,000
particles / mL 6,433,333/L ≥ 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L 99.9% /
<1/100 L 99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi (0.7 - 8.6 bar), non-
shock
• Temperature: 35 -100°F (2-38°C)
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI *
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI Standard 42.
System Tested and Certified by NSF International
against NSF/ANSI Standard 42 for the reduction of:
STANDARD NO.42 -
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Filtration
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class II
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 for the reduction of
the substances listed below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 90.6%
Particulate Class II
particles 1 to <5μm at least 10,000
particles / mL ≥ 85% 97.1%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
*Tested using flow rate = 1.0 gpm; pressure = 60 ± 3 psig; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act /
New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1.5Z3S, ZENITH 1.5NZ3S, BIRKO 1.5B3S, ZIP 2Z3S,
ZENITH 2NZ3S
System Tested and Certified by NSF International
against NSF/ANSI Standard 42 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Filtration
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class II
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless
II(a) and II(b) are passed.
N/A
III Particulate Reduction Reduces cloudiness. N/A
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead N/A
Legend: = Pass N/A = Not Applicable
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down
• Use minimum length of tubing possible
• Flush to drain for 5 minutes at full flow
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi (0.7 - 8.6 bar),
non-shock
• Temperature: 35 -100°F (2-38°C)
MODEL Flow Rate (Lpm) Capacity
1.5Z3-S 3.75 Lpm 13248 L
2Z3-S 5.678 Lpm 17034 L
1.5NZ3-S 3.75 Lpm 13248 L
2NZ3-S 5.678 Lpm 17034 L
1.5B3-S 3.75 Lpm 13248 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when
shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or
of unknown quality without adequate disinfection before or
after the system.
• The contaminants or other substances removed or reduced
by this water treatment system are not necessarily in your
water.
• Check for compliance with state and local laws
and regulations.
• Tested under standard laboratory conditions as
specified above. Actual performance may vary
depending on influent water conditions.
The term "bacteriostatic" indicates that the system limits
the passage or growth of bacteria that may already exist in
the incoming water. It does not mean that water leaving the
system is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000 AS/NZS 3497
WM-0350051
Global-Mark.com.au
AS/NZS 3497
WM -0350001WM -0350001
Global-Mark.com.auGlobal-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L 4 mg/L /
5 mg/L ≥ 50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm at least 10,000
particles / mL 6,433,333/L ≥ 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L 99.9% /
<1/100 L 99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L 0.015 mg/L /
0.01 mg/L 0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
IMicrobiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria. N/A
II (b) Virus Removal Will remove or inactivate virus. N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000 AS/NZS 3497
WM-0350001
Global-Mark.com.au
Model Flow Rate Capacity Cartridge
Kit
3mic MicroPurity
filter 1.5S 3.75 Lpm 13248 L 93703
3mic MicroPurity
Filter 2S 5.678 Lpm 17034 L 93705

Page 8 of 8 805280 v1.10 04.20 Filter Mixer Tap_AU
Zip Water (Aust) Pty Ltd ABN 46 000 578 727
67-77 Allingham Street, Condell Park NSW 2200
Postal: Locked Bag 80, Bankstown 1885 Australia
P: (+612) 9796 3100 | 1800 ZIP TAP (1800 947 827)
zipwater.com
Zip products described in this publication are manufactured under one
or more patents and further patent applications are pending.
As Zip policy is one of continuous product improvement, changes to
specifications may be made without prior notice. Images in this booklet
have been modified and may not be true representations of the finished
goods.
© 2020 Zip Water (Aust) Pty Ltd
Table of contents
Other Zip Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

METHVEN
METHVEN Aio Shower Mixer with Fastflow installation guide

Stream33
Stream33 S331HKPO15-CH installation manual

Gessi
Gessi RIFLESSI 44879 manual

Hans Grohe
Hans Grohe Metris Select 2-Spray 73822 1 Series Installation/User Instructions/Warranty

Spectrum Brands
Spectrum Brands Pfister Saxton 016-GL1 Quick installation guide

Lefroy Brooks
Lefroy Brooks M1-5400 Installation, operating, & maintenance instructions