manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ZORN INSTRUMENTS
  6. •
  7. Measuring Instrument
  8. •
  9. ZORN INSTRUMENTS ZFG 3.0 User manual

ZORN INSTRUMENTS ZFG 3.0 User manual

Other manuals for ZFG 3.0

2

This manual suits for next models

2

Other ZORN INSTRUMENTS Measuring Instrument manuals

ZORN INSTRUMENTS ZORN D plus User manual

ZORN INSTRUMENTS

ZORN INSTRUMENTS ZORN D plus User manual

ZORN INSTRUMENTS ZFG 3.1 User manual

ZORN INSTRUMENTS

ZORN INSTRUMENTS ZFG 3.1 User manual

ZORN INSTRUMENTS ZFG 3000 GPS User manual

ZORN INSTRUMENTS

ZORN INSTRUMENTS ZFG 3000 GPS User manual

ZORN INSTRUMENTS ZFG 3.0 User manual

ZORN INSTRUMENTS

ZORN INSTRUMENTS ZFG 3.0 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Guide
Light Weight Deflectometer
• ZFG 3.0
• ZFG 3.1
• ZFG 3000
According to German Technical Test
Specification for Soil and Rock in Road
Construction TP BF-StB Part B 8.3
You can find detailed operating instructions
online at www.zorn-instruments.com or follow
this direct download link.
Read the operating instructions carefully, especially the safety instructions,
before using the Light Weight Deflectometer!
(for further regulations see on the back)
Subject to change without prior notice.
Status: 01/2021
• ZFG 3.0
• ZFG 3.1
• ZFG 3000
3. Measurement Procedure
Preparation
• Place the load plate fully and horizontally on the flat test surface.
• Place the loading device on the load plate.
• Connect the electronic measuring device to the load plate via the measuring cable.
You can find the detailed operating instructions online at: www.zorn-instruments.com
Performing the Measurement
• Switch on the electronic measuring
device with the <On/Off> key.
• For devices with GPS module: After 30
seconds, the GPS receiver is logged in
and the coordinates are displayed.
• When an SD card is inserted, your
measurement results are saved
automatically and only on the SD card.
You can also perform your measure-
ments without an SD card. In this case,
the measurement results are saved on
the internal memory (flash).
• According to the test specification, a
total of six measuring impacts must be
performed: three impacts for preloa-
ding and three impacts for the measu-
rement.
• Unlock the transport safety lock.
• Start the measurement using the <OK>
key. The currently set test mode
appears (e.g. 300 mm/ 10 kg).
• Lift the drop weight and latch it into the
notching device at the upper stop.
• Align the guide rod of the loading
device vertically. Use the level as a
guide (depending on the model,
either at the top of the handle or
directly on the notching device).
• When the beep sounds and the
display prompts you to do so, unlatch
the drop weight and let it hit the
spring element. After the first impact,
catch the drop weight again at the
catch handle and latch it again.
• First perform the three impacts for
preload, then perform the three
impacts for measurement.
• After the last impact, there is a
double beep. Put down the drop
weight.
• Lock the transport safety lock.
• The display shows the three measu-
red settlement amplitudes.
• Press the <OK> key to end the
measurement.
Display of the measurement results
• You can read the date, time, average settlement, s/v value and the Evd value.
• You can use the <Mode> key to call up the settlement curves on the display.
• The display also shows the sequential number of the data set.
• Press the <OK> key again to start a new measurement.
• Note: You can cancel any measurement with the <On/Off> key. Then the measure-
ment will not be saved.
Drop Weight
Lever for Transport
Safety Lock
Spring Element in
Bellows
Tilt Protection
Centering Cone
Carrying Handle
Sensor Connector
Catch Handle
Handle
Level
Head Limit Stop
with Release
Mechanism
Guide Rod
Catch for Transport
Safety Lock
Bearing Plate
Mounting Pin with Sensor
ZFG 3.0 ZFG 3.1 ZFG 3000
1. Safety Instructions
To prevent accidents and
damage to the device, secure
the device when transporting
with the transport safety lock!
Check your Light Weight
Deflectometer for damage
before each use and only use it
if it is not damaged.
Only plug in the measuring
cable when the drop weight is
on the ground and the electro-
nic measuring device is
switched off.
Do not touch under the drop
weight when it is latched on
top!
Wearing protective work shoes
is recommended.
During the measuring process,
make sure that the transport
safety lock is removed.
To avoid injuries, only grip the
drop weight device by the
triangular catch handle!
If the Light Weight Deflectome-
ter is not in use, the drop
weight must be at the lower
end of the guide rod.
Use only recommended batte-
ries or original rechargeable
batteries for the electronic
measuring device.
Protect the printer at all times
from external influences such
as moisture and soiling, e.g.
sand and dust.
Only use the supplied charger
to recharge the ZFG 3000 or
the printer for the ZFG 3.0 or
ZFG 3.1.
2. Light Weight Deflectometer | Details
ZFG
Print Mode
ON
OFF
OK
ZFG 3.1
www.zorn-instruments.de
Printing the Measurement Results
• If available, you can print out your measurement results with the appropriate printer.
• You can print the log if you connect the electronic measuring device (ZFG 3.0, 3.1) to the
printer and press the <Print> key.
• You can also print out the logs stored on the SD card as often as you like at a later date.
You can find the detailed operating instructions online at: www.zorn-instruments.com
ZORN INSTRUMENTS GmbH & Co. KG
Benzstr. 1 | 39576 Stendal | Germany
Phone: +49 3931 / 25 27 3-0
Fax: +49 3931 / 25 27 3-10
eMail: info@zorn-instruments.com
Web: www.zorn-instruments.com
Care and Maintenance
• After each measurement process,
remove any debris, such as soil, sand,
clay or dust from the bearing plate with
the mounting pin and the loading
device with the drop weight using a
dry cloth.
• Remove stubborn dirt with methylated
spirits or kerosene. Do not use oils or
grease!
• Transport and store the drop weight
device protected from shock or impact,
dry and with the transport safety lock
engaged.
• Remove damp objects (e.g. cleaning
rags) from the device and from the
transport case.
• Avoid direct sunlight on the device.
• Regularly check the drop height
indicated on the calibration record and
the calibration plate.
• Have your Light Weight Deflectonmeter
calibrated once a year by a recognized
testing laboratory.
• Information on calibration points can be
found in the detailed operating instruc-
tions and online on our website at
www.zorn-instruments.com.
Regulations international (examples)
Austria: RVS 08.04.04 (March 2008)
Switzerland: VSS 70 313 (July 2019)
Belgium: SB 250 versie 4.1, 4.16.2 (April 2019)
Spain: UNE 103807-2:2008 (July 2008)
USA: ASTM E2835 - 11(2015)
China: TB 10001-2016 (Design Guidelines Railroad
Substructure)
Russia: N° 52068-12 (State Register of Approved
Measuring Instruments)