Read the operating instructions carefully before using the ZORN D plus!
• Dimensions: approx. 100 x 50 x 10 mm
• Weight: approx. 100 g
• Connection sensor: 6,35 mm stereo audio jack
• Connection mobile device: Bluetooth (Low Energy)
• Energy supply: Lithium Polymer Batterie (rechargeable)
• Control Indicator: two LEDs
• Languages: German/English
Technical Data
Quick Guide
ZORN D plus
The ZORN D plus is made for the wireless handling of your Light
Weight Deflectometer ZFG and serves the generation of com-
plete test reports on your Android or iOS device (from Android
5.1 and iOS 11.0 on).
Before using the ZORN D plus, also read the operating instruc-
tions for your Light Weight Deflectometer.
Latest version of the
D plus app loaded?
Following requirements are necessary for using the ZORN D plus:
• You need to have the ZORN D plus application on your mobile device.
• You can download the application from the Google Play Store or from the Apple App
Store for free. Alternatively, you can receive the download link for the ZORN D plus
application from us.
• Your mobile device must have a Bluetooth function. The Bluetooth function must be
enabled for the usage with the ZORN D plus.
• Your Light Weight Deflectometer needs to be calibrated together with the ZORN D
plus and they must carry the same serial number.
Please read the instruction manual of your Light Weight Deflectometer before
using your ZORN D plus.
• Protect the device against outside influences such as excessive direct solar radiation,
humidity and soiling!
• Only open the protection cap for charging the device!
• Only use the included charging cable or rather a cable of the same type for charging
the device!
1. Safety Instructions
2.3 Measurement Performance
• See point „2.2 Connection Establishment“
• After a measurement (3 preload impacts/ 3 load impacts), the app switches to display
mode. You can view your measurement result. Further measurements can be added by
clicking on the button "+" at the bottom right.
2.1 Preparation
• Assemble the loading plate and the loa-
ding device as it is described in the
according manual.
• Plug in the jack plug of the ZORN D plus
into the plug socket of the loading plate.
This plug socket also serves the connec-
tion between the loading plate and the
usual electronic device.
• Trough the magnets at the bottom of
your ZORN D plus you can place the
device skid-proof on the loading plate
easily.
• The built-in thermometer automatically
measures the environmental temperature.
2.2 Connection Establishment
• Turn on your ZORN D plus by pressing
the ZORN INSTRUMENTS logo. The right
blue LED underneath the ZORN INSTRU-
MENTS logo should blink quickly.
• Open the ZORN D plus application
on your mobile device. Tap on the
first button „Start measurements“.
• Automatically, the ZORN D plus applica-
tion starts to search for Bluetooth devices
in the environment. You can see your
ZORN D plus. Select the ZORN D plus for
connecting. The app now automatically
switches to measurement mode.
• The blue LED is now blinking significantly
slower.
2. Usage
A new window opens. Select the measu-
rement(s) to be transferred to the proto-
col. To do this, click on the gray tick in the
box in front of the respective measure-
ment.
This will then turn green.
Then press OK.
You can add project data in the next
screen. Click on "Print Protocol" to create
a PDF that you can save on your end
device.
2.4 Creating a test report
• Display the measurement results. Then click on the "Printer" icon and click on the measure-
ments that are to be included in the protocol (see above).
• You can then add project-specific information (e.g. contractor, client, project title, tester, test
point location, soil group, etc.).
• Then click on the "Print Protocol" button. You can save the created PDF on your device,
send it by e-mail or print it.
D plus App
01 / 57
Determination of the dynamic deflection
modulus in compliance with TP BF-StB Part
B 8.3 (2012) ASTM E2835-11 (2015)
Date/Time: 19.10.2023 : 11:53:10
Device type/Measuring type: ZORN D
plus/300 mm, 10 kg
1. Impact 164.7 mm/s 2.057 mm
2. Impact 164.7 mm/s 2.057 mm
3. Impact 164.7 mm/s 2.057 mm
Impact 1-3 Ø: 277.6 mm/s 1.391 mm
Temperature: 27 °C
ZFG Serial Number: 9726
s/v: 5.01 ms
Evd: 16.18 MN/m2
View Measurement
Lists all values (e.g. measurement point,
date, time, s/v, Evd, serial number etc.) of
the test point (scroll down if necessary).
Deflection Graph
Shows the three settlement curves of a
measuring process in comparison (course
of the settlement curves plus measured
values).
Switch back and forth between the
measured data.
Remarks
Space for individual comments/supple-
ments on the respective measurement.
Measurement location
Shows the location of the measurement
on a map.
Photo test location
Add your individual test point photo here
(one per measurement). You can take a
photo directly or select a photo from your
storage.
Sends the measure-
ment data as .zxz
files with an e-mail
program installed
on your end device.
You can process
this data in the
ZORN FG WebApp.
Click on the "+"
button to start a
new measurement.
Info
Here you will
find details on software
version, calibration date
and calibration factor
("D plus Info") and the
current operating
instructions.
2.5 Display of measured data
• If you would like to view the last measurements, press the "View measurements"
button on the start screen of the app.
• You can also create a test protocol from the saved measurement results at any time
afterwards.
• If you have saved several projects in the app, select the correct project in advance (see
below) in order to view the corresponding measurement data.
2.6 Create and display projects
• Click on "Project" on the start screen.
• Create a new project using the "New" button. You will then be asked to enter a name
for the project. Click on "OK" to confirm this. The new project is created. All following
measurements are saved under this project.
• If you would like to add new measurement data to a project that has already been
created, click again on the start screen on "Project". Select the project and press "OK".
The following measurements are saved under this project.
• To view the different measurements of the individual projects, please always select the
relevant project in advance. Only the measurements from this project will be displayed.
• Create various profiles that you can chose quickly and easily to create a protocol. To do
this, click on the "Profile" button in the corresponding window in which all project
details are displayed and select accordingly.
4. Profil
• During the charging process, the left-hand LED under the ZORN INSTRUMENTS logo
lights up red. If the charging process is complete, the LED lights up green.
• You can charge your ZORN D plus using the micro USB cable supplied.
5. Charging process
• You can open these via the "Settings" button on the start screen.
• Change the language, units, decimal places etc. as you wish.
3. Settings
Subject to change without
prior notice. Status: 11/2023
www.zorn-instruments.com
ZORN INSTRUMENTS GmbH & Co. KG
Benzstraße 1 | 39576 Stendal | Germany
Phone: +49 3931 / 25 27 3-0
Fax: +49 3931 / 25 27 3-10
eMail: info@zorn-instruments.com
Web: www.zorn-instruments.com

Popular Measuring Instrument manuals by other brands

Schmidt MK Series instruction manual

Schmidt

Schmidt MK Series instruction manual

HIOS HP-100 Operation manual

HIOS

HIOS HP-100 Operation manual

Electro-Sensors TR400 Installation & operation manual

Electro-Sensors

Electro-Sensors TR400 Installation & operation manual

Hydrotechnik Patrick operating instructions

Hydrotechnik

Hydrotechnik Patrick operating instructions

Desco Combo Tester X3 Installation, operation and maintenance

Desco

Desco Combo Tester X3 Installation, operation and maintenance

Agilent Technologies 86120C user guide

Agilent Technologies

Agilent Technologies 86120C user guide

Shimadzu TOC-V CPH user manual

Shimadzu

Shimadzu TOC-V CPH user manual

Rohde & Schwarz ESW-K55E user manual

Rohde & Schwarz

Rohde & Schwarz ESW-K55E user manual

PCB Piezotronics 3501B1260KG/M010LN manual

PCB Piezotronics

PCB Piezotronics 3501B1260KG/M010LN manual

Fluke 1630-2 user manual

Fluke

Fluke 1630-2 user manual

HT IRONMETER user manual

HT

HT IRONMETER user manual

Logitech Electronics 2000 MKII Series user guide

Logitech Electronics

Logitech Electronics 2000 MKII Series user guide

Fluke 43 user manual

Fluke

Fluke 43 user manual

LIMIT 1080-R operating manual

LIMIT

LIMIT 1080-R operating manual

Hach TOC-X5 user manual

Hach

Hach TOC-X5 user manual

Max G004 manual

Max

Max G004 manual

SPECTRO XEP05 Original operating instructions

SPECTRO

SPECTRO XEP05 Original operating instructions

RS PRO ILOM-508A instruction manual

RS PRO

RS PRO ILOM-508A instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.