TheThinDoor/WindowContact(2GIG‐DW14‐433)isdesignedforuse
ondoors,windows,andotherobjectsthatopenandclose.It
communicateswiththecontrolpanelusingthe433MHzfrequency.
Whenthemagnet(whichismountednearthesensor)movesaway
fromorclosertothedoorcontact’ssensor,signalsaretransmittedto
thecontrolpanel.Thedoorcontactalsohasanexternalinputthat
acceptsconnectionsfromNormally‐Closed(NC)drycontactdevices.
Foraddedprotection,itisalsoequippedwithacovertamper.
Figure 1 ThinDoor/WindowContact—SensorandMagnet
Box Contents
Verifythatthepackageincludesthefollowing:
•1—ThinDoor/WindowContact
•1—RareEarthMagnet
• 2—PhillipsHeadScrews
•2—3‐Volt(3V)LithiumCoinBatteries
•2—AdhesiveFoamTape
•1—12in(30cm)WireLead
Testing the Thin Door/Window Contact
Beforemountingthedoorcontactatthedesiredlocation,performa
walktesttoverifythatitcanestablishgoodRadioFrequency(RF)
communicationswiththecontrolpanel.
NOTE: TofullytesttheThinDoor/WindowContact,seethe
controlpanel’sInstallationandProgrammingGuide.
Mounting Guidelines
Usetheseguidelineswheninstallingthedoorcontactforinternal
switchusage:
•MountSensorswithin100ft(30m)oftheControlPanel.
Althoughthetransmittermayhavearangeof350ft(106.7m)
openair,thesensorlocationcanhaveasignificanteffecton
range.Inopen/unobstructedsituations,thetransmitterrange
maybegreater.Inadversewirelessconditions,changingthe
sensororientationmayleadtoimprovedrange.
•MountSensorsatLeast4.7in(12cm)AbovetheFloor.
Placingsensorsslightlyabovefloorlevelhelpstominimize
possiblesensordamage.
•Singlevs.DoubleDoorInstallation.Forsingle‐door
installation,mountthesensoronthedoorframeandthe
magnetonthedoor.Fordouble‐doorinstallation,mountthe
sensorontheleast‐useddoorandthemagnetonthemost‐
useddoor.
•DoNotExposeSensorstoMoistureorExtremeTemperature.
Itisbesttomountsensorsinadrylocationwherethe
operatingtemperaturedonotexceed32°to120°F(0°to49°
C).
•KeepSensorsandMagnetsAwayfromMetal/Metallic
Surfaces.Tokeepsensorsandmagnetsawayfrommetalor
metallicsurfaces(forexample,foilwallpaper),itis
recommendedthatyouusespacers(notincluded).Youshould
alsoavoidmountingsensorsinareaswherethereisalarge
quantityofmetalorelectricalwiring(forexample,neara
furnaceorinautilityroom).
•AlignMagnetwithSensor.Makesurethealignmentarrowon
themagnetpointstothecenteralignmentmarkonthesensor
(seeFigure1ThinDoor/WindowContact—Sensorand
Magnet).
Mounting the Thin Door/Window Contact
Usethefigurebelowasaguidelinewhenmountingthedoorcontact.
Instep7below,youhavetheoptiontomountthedoorcontactwith
anexternalinputwireforanNCdrycontactdevice.
Figure 2 ThinDoor/WindowContact—BackplateandBatteryCompartment
Tomountthedoorcontact:
1Atthetopofthesensor,pressdownonthecliptounlockthe
sensor’sbackplate.Then,gentlypulldownonthebackplateto
removeit.
2Onthebackplate,drill‐throughtopandbottommountingholesif
needed(seeFigure2ThinDoor/WindowContact—Backplateand
BatteryCompartment).
3Holdingthebackplatelocation,placethebottommountinghole
asfollows:
•SingleDoorInstallation.Atthedesiredlocationonthedoor
frame.
•DoubleDoorInstallation.Atthedesiredlocationontheleast‐
useddoor.
AThinDoor/WindowContactSensor
BThinDoor/WindowContactMagnet
CAlignmentMarksonSensor
DAlignmentArrowonMagnet
AAccessholeforexternalinputwire(onbackplate)
BTopandbottommountingholes(onbackplate)
CExternalinputwirejack(onsensor)
DTamperswitch(onsensor)
E3‐Volt(3V)lithiumcoinbatterycompartments(onsensor)
FMetalclipsforremovingbatteries(onsensor)

2Copyright © 2015 Nortek Security & Control LLC
Thin Door/Window Contact | Installation Instructions
IMPORTANT: Tominimizetheriskofpotentialsensordamage,
alwaysmountthesensorataminimumheightof4.7in(12
cm)fromthefloor.
4Usingthetwo(2)PhillipHeadScrews(provided),securethe
backplatethedoor(ordoorframe).
5Ensurethatthealignmentarrowonthemagnetislinedupwith
themiddlemarkonthesensor(seeFigure1ThinDoor/
WindowContact—SensorandMagnet).
6Usetheadhesive(provided)tosecurethemagnetasfollows:
•SingleDoorInstallation.Onthedoor.
•DoubleDoorInstallation.Onthemost‐useddoor.
IMPORTANT: Themagnetmustbenomorethan0.4in(1cm)
awayfromthesensor.
NOTE: Ifyouarenotusinganexternalinputwire,skipstep7
andcontinuewithstep8.
7Ifyouareusinganexternalinputwire,dothefollowing:
7a Threadtheexternalinputwirethroughthebase.
7b Insertthetwo‐pinconnectorintotheexternalinputwire
jackonthe(seePartCinFigure2ThinDoor/Window
Contact—BackplateandBatteryCompartment)cover.
8Replacethesensorbackplate.Ifapplicable,ensurethatthe
externalinputwireisconnectedtotheNCdrycontactdevice.
NOTE: TolearnhowtoprogramasensorintotheControlPanel,
seetheControlPanel’sInstallation&ProgrammingGuide.
Inserting and Replacing the Batteries
Toinsertorreplacethebatteries:
1Atthetopofthesensor,pushdownthecliptounlockthe
sensor’sbackplate.Then,gentlypulldownonthebackplateto
removeit.
2Placeasmallflatheadscrewdriverintheslotbetweenthemetal
clipandbattery(seePartFinFigure2ThinDoor/Window
Contact—BackplateandBatteryCompartment).
3Holdingdowntheraisedplasticedgeinthebattery
compartment,gentlytwistthescrewdrivertopopouteach
battery.
IMPORTANT: Alwaysdisposeand/orrecycleusedbatteriesin
accordancewiththehazardouswasterecoveryand
recyclingregulationsforyourlocation.Yourcity,state,or
countrymayalsorequireyoutocomplywithadditional
handling,recycling,anddisposalrequirements.
4Insertthereplacementbatteriesinthecompartment.Theplus
(+)signofbothbatteriesshouldbefacingupandtheminus(‐)
sidefacingdown.
WARNING: Failuretofollowthesewarningsandinstructions
canleadtoheatgeneration,rupture,leakage,explosion,
fire,orotherinjury,ordamage.Donotinsertthebattery
intothecompartmentinthewrongdirection.Always
replacethebatterywiththesameorequivalenttype(see
InsertingandReplacingtheBatteriesonpage2).Never
rechargeordisassemblethebattery.Neverplacethe
batteryinfireorwater.Alwayskeepbatteriesawayfrom
smallchildren.Ifbatteriesareswallowed,promptlyseea
doctor.
Specifications
Regulatory Information
Limited Warranty
ThisNortekSecurity&Controlproductiswarrantedagainstdefects
inmaterialandworkmanshipfortwo(2)years.Thiswarranty
extendsonlytowholesalecustomerswhobuydirectfromNortek
Security&ControlLLCorthroughNortekSecurity&ControlLLC’s
normaldistributionchannels.NortekSecurity&ControlLLCdoes
notwarrantthisproducttoconsumers.Consumersshouldinquire
fromtheirsellingdealerastothenatureofthedealer’swarranty,if
any.
TherearenoobligationsorliabilitiesonthepartofNortekSecurity
&ControlLLCforconsequentialdamagesarisingoutoforin
connectionwithuseorperformanceofthisproductorother
indirectdamageswithrespecttolossofproperty,revenue,or
profit,orcostofremoval,installation,orreinstallation.Allimplied
warrantiesforfunctionality,arevalidonlyuntilthewarranty
expires.ThisNortekSecurity&ControlLLCWarrantyisinlieuofall
otherwarrantiesexpressedorimplied.
NortekSecurity&ControlLLC
2GIG
1950CaminoVidaRoble,Suite150
Carlsbad,CA92008‐6517USA
FortechnicalsupportintheUSAandCanada:
855‐2GIG‐TECH(855‐244‐4832)
Email:2gigtechsupport@nortek.com
Visitwww.nortekcontrol.comfortechnicalsupporthoursofoperation
FortechnicalsupportoutsideoftheUSAandCanada:
Contactyourregionaldistributor
Visitdealer.2gig.comforalistofdistributorsinyourregion
77‐000014‐001Rev.D
WirelessSignalRange 350ft(106.7m),openair,withWireless
ControlPanel
CodeOutputs Alarm;AlarmRestore;Supervisory;Low
Battery;ExternalAlarm;ExternalRestore;
Tamper;Ta mperRestore
TransmitterFrequency 433.92MHz(crystalcontrolled)
UniqueIDCodes Overone(1)milliondifferentcode
combinations
SupervisoryInterval 70minutes
ExternalInput AcceptsN/Cdrycontactdevices
MagnetDimensions(LxWxH) 1.3x0.435x0.312in(3.3x1.1x0.79cm)
MagnetType RareEarth
SensorDimensions(DxH) 2.59x1.03x0.49in(6.58x2.62x1.24cm)
Weight(includingbattery&magnet) 1.1oz(31.2g)
HousingMaterial ABSPlastic
Color White
OperatingTemperatu re 32°‐120°F(0°‐49°C)
RelativeHumidity 5‐90%Non‐Condensing
Battery(included) Two(2)PanasonicCR2032orequivalent
Lithiumbatteries
Certification CEandRCM
Popular Lock manuals by other brands

Alarm Lock
Alarm Lock Trilogyx2: P/DL5300 quick guide

Manutan
Manutan A149197 user guide

Schlage
Schlage CM993 Series Installation instructions and information manual

Safety 1st
Safety 1st OutSmart HS270 user guide

Assa Abloy
Assa Abloy LOCWOOD 001TOUCH user guide

Tecnosicurezza
Tecnosicurezza TechMaster T9530/GR installation instructions