manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 2gig Technologies
  6. •
  7. Lock
  8. •
  9. 2gig Technologies 2GIG-DW14-433 User manual

2gig Technologies 2GIG-DW14-433 User manual

Copyright © 2015 Nortek Security & Control LLC 1
2GIG-DW14-433
THIN DOOR/WINDOW CONTACT
INSTALLATION INSTRUCTIONS
TheThinDoor/WindowContact(2GIG‐DW14‐433)isdesignedforuse
ondoors,windows,andotherobjectsthatopenandclose.It
communicateswiththecontrolpanelusingthe433MHzfrequency.
Whenthemagnet(whichismountednearthesensor)movesaway
fromorclosertothedoorcontact’ssensor,signalsaretransmittedto
thecontrolpanel.Thedoorcontactalsohasanexternalinputthat
acceptsconnectionsfromNormally‐Closed(NC)drycontactdevices.
Foraddedprotection,itisalsoequippedwithacovertamper.
Figure 1 ThinDoor/WindowContact—SensorandMagnet
Box Contents
Verifythatthepackageincludesthefollowing:
•1—ThinDoor/WindowContact
•1—RareEarthMagnet
• 2—PhillipsHeadScrews
•2—3‐Volt(3V)LithiumCoinBatteries
•2—AdhesiveFoamTape
•1—12in(30cm)WireLead
Testing the Thin Door/Window Contact
Beforemountingthedoorcontactatthedesiredlocation,performa
walktesttoverifythatitcanestablishgoodRadioFrequency(RF)
communicationswiththecontrolpanel.
NOTE: TofullytesttheThinDoor/WindowContact,seethe
controlpanel’sInstallationandProgrammingGuide.
Mounting Guidelines
Usetheseguidelineswheninstallingthedoorcontactforinternal
switchusage:
•MountSensorswithin100ft(30m)oftheControlPanel.
Althoughthetransmittermayhavearangeof350ft(106.7m)
openair,thesensorlocationcanhaveasignificanteffecton
range.Inopen/unobstructedsituations,thetransmitterrange
maybegreater.Inadversewirelessconditions,changingthe
sensororientationmayleadtoimprovedrange.
•MountSensorsatLeast4.7in(12cm)AbovetheFloor.
Placingsensorsslightlyabovefloorlevelhelpstominimize
possiblesensordamage.
•Singlevs.DoubleDoorInstallation.Forsingle‐door
installation,mountthesensoronthedoorframeandthe
magnetonthedoor.Fordouble‐doorinstallation,mountthe
sensorontheleast‐useddoorandthemagnetonthemost‐
useddoor.
•DoNotExposeSensorstoMoistureorExtremeTemperature.
Itisbesttomountsensorsinadrylocationwherethe
operatingtemperaturedonotexceed32°to120°F(0°to49°
C).
•KeepSensorsandMagnetsAwayfromMetal/Metallic
Surfaces.Tokeepsensorsandmagnetsawayfrommetalor
metallicsurfaces(forexample,foilwallpaper),itis
recommendedthatyouusespacers(notincluded).Youshould
alsoavoidmountingsensorsinareaswherethereisalarge
quantityofmetalorelectricalwiring(forexample,neara
furnaceorinautilityroom).
•AlignMagnetwithSensor.Makesurethealignmentarrowon
themagnetpointstothecenteralignmentmarkonthesensor
(seeFigure1ThinDoor/WindowContact—Sensorand
Magnet).
Mounting the Thin Door/Window Contact
Usethefigurebelowasaguidelinewhenmountingthedoorcontact.
Instep7below,youhavetheoptiontomountthedoorcontactwith
anexternalinputwireforanNCdrycontactdevice.
Figure 2 ThinDoor/WindowContact—BackplateandBatteryCompartment
Tomountthedoorcontact:
1Atthetopofthesensor,pressdownonthecliptounlockthe
sensor’sbackplate.Then,gentlypulldownonthebackplateto
removeit.
2Onthebackplate,drill‐throughtopandbottommountingholesif
needed(seeFigure2ThinDoor/WindowContact—Backplateand
BatteryCompartment).
3Holdingthebackplatelocation,placethebottommountinghole
asfollows:
•SingleDoorInstallation.Atthedesiredlocationonthedoor
frame.
•DoubleDoorInstallation.Atthedesiredlocationontheleast‐
useddoor.
AThinDoor/WindowContactSensor
BThinDoor/WindowContactMagnet
CAlignmentMarksonSensor
DAlignmentArrowonMagnet
AAccessholeforexternalinputwire(onbackplate)
BTopandbottommountingholes(onbackplate)
CExternalinputwirejack(onsensor)
DTamperswitch(onsensor)
E3‐Volt(3V)lithiumcoinbatterycompartments(onsensor)
FMetalclipsforremovingbatteries(onsensor)
2Copyright © 2015 Nortek Security & Control LLC
Thin Door/Window Contact | Installation Instructions
IMPORTANT: Tominimizetheriskofpotentialsensordamage,
alwaysmountthesensorataminimumheightof4.7in(12
cm)fromthefloor.
4Usingthetwo(2)PhillipHeadScrews(provided),securethe
backplatethedoor(ordoorframe).
5Ensurethatthealignmentarrowonthemagnetislinedupwith
themiddlemarkonthesensor(seeFigure1ThinDoor/
WindowContact—SensorandMagnet).
6Usetheadhesive(provided)tosecurethemagnetasfollows:
•SingleDoorInstallation.Onthedoor.
•DoubleDoorInstallation.Onthemost‐useddoor.
IMPORTANT: Themagnetmustbenomorethan0.4in(1cm)
awayfromthesensor.
NOTE: Ifyouarenotusinganexternalinputwire,skipstep7
andcontinuewithstep8.
7Ifyouareusinganexternalinputwire,dothefollowing:
7a Threadtheexternalinputwirethroughthebase.
7b Insertthetwo‐pinconnectorintotheexternalinputwire
jackonthe(seePartCinFigure2ThinDoor/Window
Contact—BackplateandBatteryCompartment)cover.
8Replacethesensorbackplate.Ifapplicable,ensurethatthe
externalinputwireisconnectedtotheNCdrycontactdevice.
NOTE: TolearnhowtoprogramasensorintotheControlPanel,
seetheControlPanel’sInstallation&ProgrammingGuide.
Inserting and Replacing the Batteries
Toinsertorreplacethebatteries:
1Atthetopofthesensor,pushdownthecliptounlockthe
sensor’sbackplate.Then,gentlypulldownonthebackplateto
removeit.
2Placeasmallflatheadscrewdriverintheslotbetweenthemetal
clipandbattery(seePartFinFigure2ThinDoor/Window
Contact—BackplateandBatteryCompartment).
3Holdingdowntheraisedplasticedgeinthebattery
compartment,gentlytwistthescrewdrivertopopouteach
battery.
IMPORTANT: Alwaysdisposeand/orrecycleusedbatteriesin
accordancewiththehazardouswasterecoveryand
recyclingregulationsforyourlocation.Yourcity,state,or
countrymayalsorequireyoutocomplywithadditional
handling,recycling,anddisposalrequirements.
4Insertthereplacementbatteriesinthecompartment.Theplus
(+)signofbothbatteriesshouldbefacingupandtheminus(‐)
sidefacingdown.
WARNING: Failuretofollowthesewarningsandinstructions
canleadtoheatgeneration,rupture,leakage,explosion,
fire,orotherinjury,ordamage.Donotinsertthebattery
intothecompartmentinthewrongdirection.Always
replacethebatterywiththesameorequivalenttype(see
InsertingandReplacingtheBatteriesonpage2).Never
rechargeordisassemblethebattery.Neverplacethe
batteryinfireorwater.Alwayskeepbatteriesawayfrom
smallchildren.Ifbatteriesareswallowed,promptlyseea
doctor.
Specifications
Regulatory Information
Limited Warranty
ThisNortekSecurity&Controlproductiswarrantedagainstdefects
inmaterialandworkmanshipfortwo(2)years.Thiswarranty
extendsonlytowholesalecustomerswhobuydirectfromNortek
Security&ControlLLCorthroughNortekSecurity&ControlLLC’s
normaldistributionchannels.NortekSecurity&ControlLLCdoes
notwarrantthisproducttoconsumers.Consumersshouldinquire
fromtheirsellingdealerastothenatureofthedealer’swarranty,if
any.
TherearenoobligationsorliabilitiesonthepartofNortekSecurity
&ControlLLCforconsequentialdamagesarisingoutoforin
connectionwithuseorperformanceofthisproductorother
indirectdamageswithrespecttolossofproperty,revenue,or
profit,orcostofremoval,installation,orreinstallation.Allimplied
warrantiesforfunctionality,arevalidonlyuntilthewarranty
expires.ThisNortekSecurity&ControlLLCWarrantyisinlieuofall
otherwarrantiesexpressedorimplied.
NortekSecurity&ControlLLC
2GIG
1950CaminoVidaRoble,Suite150
Carlsbad,CA92008‐6517USA
FortechnicalsupportintheUSAandCanada:
855‐2GIG‐TECH(855‐244‐4832)
Email:2gigtechsupport@nortek.com
Visitwww.nortekcontrol.comfortechnicalsupporthoursofoperation
FortechnicalsupportoutsideoftheUSAandCanada:
Contactyourregionaldistributor
Visitdealer.2gig.comforalistofdistributorsinyourregion
77‐000014‐001Rev.D
WirelessSignalRange 350ft(106.7m),openair,withWireless
ControlPanel
CodeOutputs Alarm;AlarmRestore;Supervisory;Low
Battery;ExternalAlarm;ExternalRestore;
Tamper;Ta mperRestore
TransmitterFrequency 433.92MHz(crystalcontrolled)
UniqueIDCodes Overone(1)milliondifferentcode
combinations
SupervisoryInterval 70minutes
ExternalInput AcceptsN/Cdrycontactdevices
MagnetDimensions(LxWxH) 1.3x0.435x0.312in(3.3x1.1x0.79cm)
MagnetType RareEarth
SensorDimensions(DxH) 2.59x1.03x0.49in(6.58x2.62x1.24cm)
Weight(includingbattery&magnet) 1.1oz(31.2g)
HousingMaterial ABSPlastic
Color White
OperatingTemperatu re 32°‐120°F(0°‐49°C)
RelativeHumidity 5‐90%Non‐Condensing
Battery(included) Two(2)PanasonicCR2032orequivalent
Lithiumbatteries
Certification CEandRCM

Popular Lock manuals by other brands

DEVAISE Smart Lock Instruction

DEVAISE

DEVAISE Smart Lock Instruction

AmazonBasics B07T2C4791 manual

AmazonBasics

AmazonBasics B07T2C4791 manual

Easy Access EASYTOUCH 903 manual

Easy Access

Easy Access EASYTOUCH 903 manual

COMPX C8701 Dimensional drawing

COMPX

COMPX C8701 Dimensional drawing

JNF IN.28.501 quick start guide

JNF

JNF IN.28.501 quick start guide

Taymor Centinel 3 installation instructions

Taymor

Taymor Centinel 3 installation instructions

Piot PiTraveler K200 quick start guide

Piot

Piot PiTraveler K200 quick start guide

FISCHER 85872 operating instructions

FISCHER

FISCHER 85872 operating instructions

Speakman CPT-1000-TP instructions

Speakman

Speakman CPT-1000-TP instructions

Rittal DK 7030.222 Assembly and operating instructions

Rittal

Rittal DK 7030.222 Assembly and operating instructions

HTV NICO user manual

HTV

HTV NICO user manual

Dormakaba T900 installation instructions

Dormakaba

Dormakaba T900 installation instructions

Securam ProLogic B01 operating instructions

Securam

Securam ProLogic B01 operating instructions

XLOCK 220 instruction manual

XLOCK

XLOCK 220 instruction manual

SECO-LARM E-941SA-1K2PD installation manual

SECO-LARM

SECO-LARM E-941SA-1K2PD installation manual

FSH FCL0001 installation instructions

FSH

FSH FCL0001 installation instructions

lockin G30 user manual

lockin

lockin G30 user manual

TTI KR-120M user guide

TTI

TTI KR-120M user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.