6000 Series alf-Mask
Respirators
Data Sheet
The table above lists the filters and typical industrial
applications.
The 6000 Series half masks can be used in a variety of
different filter / product options :
• Gas and vapour ilters - The 6000 Series filters fit directly
onto the 6000 Series half masks.
• Particulate ilters - The 2000 Series particulate filters fit
directly on to the 6000 Series half masks. The 5911 / 5925 /
5935 particulate filters may be used on their own with platform
603 & retainer 501.
Main Features
The 6000 Series Respirators are used with twin lightweight filters
which are fitted by a simple bayonet attachment system,
providing an economical and flexible choice. The respirators can
also be used with the 3M S-200 Supplied-Air System for increased
convenience and flexibility.
• Lightweight
• Flexible system (gas / vapour and / or particulate filters
plus Supplied-Air option)
• ypo-allergenic facepiece material
• Easy to use
• Well balanced
• 3 sizes (6100 - small, 6200 - medium, 6300 - large)
• Low maintenance
• Economical
Applications
Particulates
3
FILTER
5911 P1 R
5925 P2 R
5935 P3 R
2125 P2 R
2135 P3 R
6035 P3 R
(EN143:2000)
2128 P2 R
2138 P3 R
(EN143:2000)
6038 P3 R
(EN143:2000)
INDUSTRY
Pharmaceutical
Powdered Chemicals
Construction, Quarrying
Ceramics
Refractory Materials
Foundries, Agriculture
Woodworking, Food Industry
Welding, Paper Industry
Brewing,
Chemical Processing
Typical Smog, Inks and Dyes
Aluminium
Welding
Agriculture
Pharmaceutical
HAZARD
Particulates (Fine
Dusts and Mists)
Particulates and
nuisance levels of
Organic Vapours
and Acid Gases
Particulates,
ydrogen Fluoride
Gas up to 30ppm
and relief from
Ozone, Organic
Vapours and Acid
Gases below WEL
FILTER
6051 A1
6055 A2
(EN14387:2004)
6054 K1
(EN141:2000)
6057 ABE1
(EN141:2000)
6059 ABEK1
(EN141:2000)
6075 A1 &
formaldehyde
(EN141:2000)
6096 gP3
(EN141:2000)
HAZARD
Organic
Vapours
Ammonia
Organic
Vapours, Inor-
ganic and
Acid Gases
Organic
Vapours, Inor-
ganic Gases,
Acid gases
and Ammonia
Organic
Vapours and
Formaldehyde
Mercury and
particulates
INDUSTRY
Anywhere conventional paints are
used (subject to usage conditions)
Vehicle manufacture
Aircraft manufacture and refur-
bishment
Boat building
Ink and Dye manufacture and
use
Adhesive manufacture and use
Paint and varnish manufacture
Resin manufacture and use
Manufacture and Maintenance of
refrigeration equipment
Agrochemicals
As 6051 but also:
Electrolytic processes
Acid cleaning
Metal Pickling
Metal Etching
As 6057 and 6054
As 6051 but also:
ospitals and Laboratories
Laboratories and particulate appli-
cations
Gas/vapour
• A combination o gas / vapour and particulate ilters - The
5911 / 5925 / 5935 particulate filters can be used with 6000
Series gas / vapour filters using retainer 501.
Note: the 6098 or 6099 filters should not be used with the
6000 Series half masks.
• Supplied-air mode using the 3M S-200 Respirator System
(For information on the Supplied-Air System and applications
please see the 3M S-200 Data Sheet).
Approvals
The 3M 6000 Series half masks and 6000/5000/2000 Series
filters have been shown to meet the Basic Safety Requirements
under Article 10 and 11 B of the European Community Directive
89/686, and are thus CE-marked.
• Approval body for the facepieces:
DANTEST identification number 0200
• Body involved in Quality Assurance Assessment:
BSI/UL identification number 0086
Materials
• Facepiece - Thermoplastic Elastomer
• ead arness - Polyester / Cotton Elastic
• Inhale Valve - Natural Rubber
• Exhale Valve - Silicone Rubber
• Gasket - Silicone Rubber
• Filter Body (6000) - Polystyrene
• Filter Element (6000) - Activated/Treated Carbon
• Filter Material (5911 / - Polypropylene
5925 / 5935 and 2000
Series)
Maximum Product Weight:
- With filters 355 grams
- Without filters 85 grams
Standards
These products have been tested to the relevant European Standards as
shown below:
Facepiece EN140:1998 (6100, 6200, 6300)
Filter EN141:2000 (6054, 6057, 6059,
6075 & 6096)
EN14387:2004 (6051, 6055)
EN 143:2000 (2125, 2128, 2135,
2138, 5911, 5925, 5935, 6035,
6038)
Correct Usage
The 6000 Series facepieces when fitted with 6000 Series
gas/vapour filters may be used in concentrations of gases or
vapours (types specified by 3M) up to 10 times WEL or 1000 ppm
(5000 ppm for 6055) whichever value is lower (APF = 10)*.
Gas/vapour filters should not be used to protect the wearer
against a gas or vapour that has poor warning properties (smell
or taste).
• The 6000 Series facepieces when used in conjunction with the
5911 filter may be used in concentrations of solid and aqueous
aerosols up to 4 times WEL (APF = 4)*.
• The 6000 Series facepieces when used in conjunction
with the 5925, 2125, or 2128 filters may be used in
concentrations of particulates up to 10 times WEL
(APF = 10)*.
• The 6000 Series facepieces when used in conjunction
with the 5935, 2135, 6038, 6035, or 2138 may be used in
concentrations of particulates up to 20 times WEL
(APF = 20)*.
• The 6000 Series facepieces when used in conjunction with the
2128 and 2138 may be used to protect against ozone up to 10
times WEL (APF = 10)* and offer relief from nuisance odours
below the WEL.
• The 6000 Series facepieces when used in conjunction with the
2128 and 2138 may be used to offer relief from acid gases
below the WEL.
• The 6000 Series facepieces when used with the 6038 filter
may be used to protect against ydrogen Fluoride gas up to
30ppm and offer relief from Ozone, Organic Vapours and acid
gases below WEL.
*WEL - Workplace Exposure Limit.
Cleaning and Storage
1. Cleaning is recommended after each use. Remove the
gas/vapour and/or particulate filters.
2. Clean the facepiece (excluding filters) with 3M 105 face seal
cleaners or by immersing in warm cleaning solution, water
temperature not to exceed 50°C and scrub with soft brush until
clean. Add neutral detergent if necessary.
Do not use cleaners containing lanolin or other oils.
3. Rinse in fresh, warm water and air dry in a non- contaminated
atmosphere.
4. Respirator components, especially exhalation valve and seat,
should be inspected prior to each use. A respirator with any
damaged or deteriorated components should be discarded.
5. The cleaned respirator should be stored away from
contaminated areas when not in use.
Fitting Instructions
Fitting instructions must be followed each time the respirator is
worn.
1. Place the respirator
over the mouth and
nose, then pull the
harness over the
crown of the head.
2. Take the bottom
straps in both hands,
place them at the
back of the neck and
hook them together.
3. Tighten the top
straps first by pulling
on ends
to achieve a
comfortable and
secure fit.
4. Tighten bottom
straps using either
front or rear
adjustments.
(Strap tension
may be decreased by
pushing out on back
side of buckles).
5. Perform a positive
and/or negative
pressure fit check
(see overleaf).
05/2007 C 6000 MDS
Face Fitting
The negative pressure fit check is recommended when using the
6035, 6038 and 2000 Series filters; the positive pressure fit check
is recommended when using other filters.
Positive Pressure Face it Check
Place the palm of the hand over the exhalation valve cover and
exhale gently.
If the facepiece bulges slightly and no air leaks between the face
and the facepiece are detected, a proper fit has been achieved.
If air leakage is detected, reposition the respirator on the face
and/or readjust the elastic strap to eliminate the leakage.
Repeat the above facefit check.
Negative Pressure Face it Check
For the 2000 Series filters, press your thumbs into the central
indentation of the filters, inhale gently and hold your breath for
five or ten seconds.
For the 6035 and 6038 filters, pinch the filter between thumb and
fingers to seal the filter cover to the body of the filter, inhale gently
and hold your breath for five or ten seconds.
If the facepiece collapses slightly a proper fit has been achieved.
If air leakage is detected, reposition the respirator on the face
and/or readjust the elastic strap to eliminate the leakage.
Repeat the above facefit check.
If you cannot achieve a proper fit, do not enter the contaminated
area. See your supervisor.
Respiratory protection is only effective if it is correctly selected,
fitted and worn throughout the time when the wearer is exposed
to respiratory contaminants.
3M offers advice on the selection of products, and training in the
correct fitting and usage.
For advice on 3M Product Selection, ring the 3M ealth and
Safety elpline on 0870 60 800 60. For callers within the
Republic of Ireland, call 1-800-320 500.
3M Spare Parts and Accessories
P
Pa
ar
rt
t N
No
o.
.D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
6895 6000 Series gaskets
501 Filter retainer for 5911, 5925 or 5935
603 Particulate filter platform
105 Facepiece cleaner
Use Limitations
1. These respirators do not supply oxygen.
Do not use in oxygen deficient atmospheres *
2. Do not use for respiratory protection against atmospheric
contaminants which have poor warning properties, are
unknown or immediately dangerous to life and health or
against chemicals which generate high heats of reaction with
chemical filters.
(The 3M S-200 Supplied-Air Respirator System can be used
against contaminants with poor warning properties, subject to
other use limitations).
3. Do not modify or alter this device.
4. The assembled respirator may not provide a satisfactory face
seal with certain physical characteristics (such as beards or
large side burns) resulting in leakage between the facepiece
and the face, the user assumes all risks of bodily injury which
may possibly result.
5. Do not use with unknown concentrations of contaminants.
6. Do not use for escape purposes.
7. Leave the work area immediately and check the integrity of
the respirator and replace facepiece and/or filters if:
i) Damage has occurred or is apparent.
ii) Breathing becomes difficult or increased breathing
resistance occurs.
iii) Dizziness or other distress occurs.
iv) You taste or smell the contaminant or an irritation
occurs.
8. Store this device in a sealed container away from
contaminated areas when not in use.
9. Use strictly in accordance with face piece and filter instruction
leaflet.
* 3M definition minimum 19.5% by volume oxygen.
Occupational Health Group Occupational Health Group
3M United Kingdom PLC 3M Ireland
3M Centre 3M ouse, Adelphi Centre,
Cain Road, Bracknell Upper Georges St.
Berkshire RG12 8 T Dun Laoghaire, Co. Dublin, Ireland
Tel: 0870 60 800 60 Tel: 1 800 320 500
www.3m.com/uk/ohes
[email protected]
3

Other manuals for 600 Series

1

Other 3M Security Sensor manuals

3M Macurco CM-E1 User manual

3M

3M Macurco CM-E1 User manual

3M Petrifilm 6402 Instruction sheet

3M

3M Petrifilm 6402 Instruction sheet

3M DBI SALA Pro Series User manual

3M

3M DBI SALA Pro Series User manual

3M DBI-SALA LAD-SAF User manual

3M

3M DBI-SALA LAD-SAF User manual

3M LAD-SAF User manual

3M

3M LAD-SAF User manual

3M Rollgliss User manual

3M

3M Rollgliss User manual

3M MACURCO GD-2 User manual

3M

3M MACURCO GD-2 User manual

3M Dynatel 2210 User manual

3M

3M Dynatel 2210 User manual

3M DBI SALA LAD-SAF X3 User manual

3M

3M DBI SALA LAD-SAF X3 User manual

3M SD-200 User manual

3M

3M SD-200 User manual

3M 8511 User manual

3M

3M 8511 User manual

3M DBI-SALA Nano-Lok XL Series User manual

3M

3M DBI-SALA Nano-Lok XL Series User manual

3M DBI SALA 8705 Series Installation instructions

3M

3M DBI SALA 8705 Series Installation instructions

3M DBI SALA 2108406 Operator's manual

3M

3M DBI SALA 2108406 Operator's manual

3M MACURCO GD-6 User manual

3M

3M MACURCO GD-6 User manual

3M 8516 User manual

3M

3M 8516 User manual

3M WL-AD-2002-A User manual

3M

3M WL-AD-2002-A User manual

3M SEALED-BLOK Series User manual

3M

3M SEALED-BLOK Series User manual

3M DBI-SALA 2190071 Operator's manual

3M

3M DBI-SALA 2190071 Operator's manual

3M DBI SALA 9506038 Operator's manual

3M

3M DBI SALA 9506038 Operator's manual

3M SecureFit X5500NVE User manual

3M

3M SecureFit X5500NVE User manual

3M Dynatel 2273M-iD Series User manual

3M

3M Dynatel 2273M-iD Series User manual

3M Faceshields User manual

3M

3M Faceshields User manual

3M DBI-SALA ExoFit NEX Operation and maintenance manual

3M

3M DBI-SALA ExoFit NEX Operation and maintenance manual

Popular Security Sensor manuals by other brands

Aritech RF430I4 Installation sheet

Aritech

Aritech RF430I4 Installation sheet

MSA ORION Operation manual

MSA

MSA ORION Operation manual

B.E.G. LUXOMAT Indoor 180-M-2C Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT Indoor 180-M-2C Installation and operating instruction

Philio Technology Corporation PSM08 manual

Philio Technology Corporation

Philio Technology Corporation PSM08 manual

Allen-Bradley GuardShield Micro 400 installation instructions

Allen-Bradley

Allen-Bradley GuardShield Micro 400 installation instructions

Orno OR-CR-265 quick start guide

Orno

Orno OR-CR-265 quick start guide

Risco ShockTec Plus Grade 3 installation instructions

Risco

Risco ShockTec Plus Grade 3 installation instructions

Omron F3S-TGR-SB2-KXC user manual

Omron

Omron F3S-TGR-SB2-KXC user manual

Antec Scientific FlexCell user manual

Antec Scientific

Antec Scientific FlexCell user manual

Versahaul VH-SR quick start guide

Versahaul

Versahaul VH-SR quick start guide

netvox RA0708 user manual

netvox

netvox RA0708 user manual

PCE Health and Fitness PCE-186 CB user manual

PCE Health and Fitness

PCE Health and Fitness PCE-186 CB user manual

HP 423A Operating note

HP

HP 423A Operating note

Takex PIR-T15WE(W) instruction manual

Takex

Takex PIR-T15WE(W) instruction manual

AJAX Systems DoorProtect user manual

AJAX Systems

AJAX Systems DoorProtect user manual

Visonic CLIP SMA Installation

Visonic

Visonic CLIP SMA Installation

iBeam TE-BPCIR product manual

iBeam

iBeam TE-BPCIR product manual

Olympia 6105 operating manual

Olympia

Olympia 6105 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.