3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129
+1 303 475 4972
[email protected]© 3millID100-02635-Awww.3millid.comRemove module securement screw. Lever bottom edge of reader module away from the backplate, and lift up.3.installation guideOnce the backplate is secured, make wire connections to the reader, in accordance with the screw terminal connections shown onPage 3 of this document and your control panel requirements. Ensure the cable does not impair or prevent the reader module being secured.i
Backplate FIXING TEMPLATE.If printed full scale, you may use the drawing below as a fixing template.MEASURE and CHECK DIMENSIONS before use.Fix reader BACKPLATE to a plain surface finish, using suitable screw fixings having a diameter no greater than 0.15 in. (4mm).Fasten the reader module, ensuring the top-edge fixing lugs engage correctly with the recesses at the top of the backplate. Swing the bottom edge of the module down and forward until you feel the unit ‘snap’ shut.
i
Following installation, it is recommended the access control system and control units are subjected to a maintenance and operational test procedure.TEST COMPLETE SYSTEM AT LEAST ONCE A YEAR12345Secure the module to the backplate using the M3x10mm screw supplied.If required, you may opt to use a security screw to the sizes shown here.
i
Mounting this reader on (or near) metal may impair the read range of the unit.
2.7 in.(65mm)
1.4 in.(34.4mm)
1.9 in.(49mm)0.5 in.(13mm)
MANUAL3MInline4