4IPNET WHG505 User manual

WHG505
V1 . 2 0
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH
Copyright N otic e
This document is protected by USA copyright laws and other laws and is the property of
4 I P N E T, I N . Y ou may not copy, reproduce, distribute, publish, display, perform, or
modify any part of this publication in any form or by any means without prior written
permission from 4 I P N E T, I N . Y ou may not alter or remov e any copyright or other notice
from copies of the content. All other brand and product names are claimed or
registered mark s of their respectiv e companies or organiz ations.
All rights reserv ed.
F CC Ca u tion
This eq uipment has been tested and prov en to comply with the limits for a class B
digital dev ice, pursuant to part 1 5 of the F R ules. These limits are designed to prov ide
reasonable protection against harmful interference in a residential installation. This
eq uipment generates uses and can radiate radio freq uency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. H owev er, there is no guarantee that interference will not
occur in a particular installation. I f this eq uipment does cause harmful interference to
radio or telev ision reception, which can be determined by turning the eq uipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
R eorient or relocate the receiv ing antenna.
I ncrease the separation between the eq uipment and receiv er.
onnect the eq uipment into an outlet on a circuit different from that to which the
receiv er is connected.
onsult the dealer or an ex perienced radio/ TV technician for help.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

Preface
This Quick Installation Guide provides
instructions and reference material for
getting started with the 4ipnet WHG505
Secure WLAN Controller. This guide will
also show how to connect 4ipnet WHG505
to other network equipments.
Package Contents
1. 4ipnet WHG505 x 1
2. CD-ROM (User’s Manual and QIG) x 1
3. Quick Installation Guide (QIG) x 1
4. RS-232 DB9 to RJ45 Console Cable x 1
5. Crossover Ethernet Cable x 1
6. Straight-through Ethernet Cable x 1
7. Power Cord x 1
8. Rack Mounting Bracket (with Screws) x 1
It is highly recommended to use all the
supplies in the package instead of substituting
any components by other suppliers to guarantee
best performance.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

System Overview
Front Panel
1. LED Indicators: There are three kinds of LED, Power, Status and Hard-disk, to indicate different status
of the system.
2. Mgmt: For management use only, it always will open WMI (Web Management Interface) homepage. If
connect to this port with PC directly, please use crossover Ethernet cable.
3. WAN1/ WAN2: Two WAN ports (10/100/1000 Base-T RJ-45) are connected to the external network, such
as the ADSL Router from your ISP (Internet Service Provider).
4. LAN1/ LAN2: Client machines connect to WHG505 via LAN ports (10/100/1000 Base-T RJ-45).
5. Reset:
Press and hold the Reset button for about 5 seconds and status of LED on front panel will start to
blink before restarting the system.
Press and hold the Reset button for more than 10 seconds and status of LED on the front panel will
start to speed up blinking before resetting the system to default configuration.
6. Console: The system can be configured via a serial console port. The administrator can use a terminal
emulation program such as Microsoft’s Hyper Terminal to login to the configuration console interface to
change admin password or monitor system status, etc.
Rear Panel
1. Power Supply Socket:Connecting the power cord to the built-in open-frame power supply (Input: 100~240
VAC, 50/60 Hz ).
2. Power Switch:Power-On (|) & Power-Off ( O ).
3. Device Cooling Fan:Don’t block the cooling fans. Leave enough open space for ventilation.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

H a rd wa re I n sta l l a tio n
Please follow the following steps to install WHG505:
1. Connect the power cord to the power socket on the rear panel.
2. Turn on the power switch on the rear panel. The Power LED should be on to indicate a proper connection.
3. Connect an Ethernet cable to the WAN1 Port on the front panel. Connect the other end of the Ethernet
cable to an xDSL/cable modem, or a switch/hub of an internal network. The LED of this port should be on
to indicate a proper connection.
4. Connect a crossover Ethernet cable to the Mgmt Port on the front panel. Connect the other end of the
Ethernet cable to an administrator PC for configuring the WHG505 system, an AP for extending wireless
coverage, a switch for connecting more wired clients, or a client PC. The LED of Mgmt port should be on to
indicate a proper connection.
Usually a straight RJ-45 could be applied if WHG505 is connected to a hub/computer which supports
automatic crossover. However, after theAccess Point hardware is reset, WHG505 would not be able
to connect to theAccess Point while connecting with a straight cable unless the cable was pulled out
and plugged in again. This scenario does NOT occur while using a crossover cable.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

G ettin g Sta rted
< System Concept >
4ipnet WHG505 is capable of managing user authentication, authorization and accounting. The user account
information is stored in the local database or a specified external database server. Featured with user
authentication and integrated with external payment gateway, WHG505 allows users to easily pay the fee and
enjoy the Internet service using credit cards through Authorize.net or PayPal. With centralizedAP
management feature, the administrator does not need to worry about how to manage multiple wireless access
point devices. Furthermore,WHG505 introduces the concept of Service Zones - multiple virtual networks, each
with its own definable access control profiles. This is very useful for hotspot owners seeking to provide different
customers or staff with different levels of network services. The following diagram is an example of WHG505
set to manage the Internet and network access services at a hotspot venue.
< Web Management Interface >
4ipnet WHG505 supports web-based configuration. Upon the completion of hardware installation, WHG505
can be configured via web browsers with JavaScript enabled such as Internet Explorer version 6.0 and above
or Firefox.
1. To access the web management interface, connect a PC to the Mgmt Port, and then launch a browser.
Make sure you have set DHCP in TCP/IP of your PC to get an IP address dynamically.
2. Next, enter the gateway IP address of WHG505 at the address field. The default gateway IP address
is“http://192.168.255.254” (“https” is used for a secured connection).
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

3. The administrator login page will appear. Enter “admin”, the default username, and “admin”, the default
password, in the User Name and Password fields. Click Enter to log in.
4. After a successful login, a “Welcome to System Administration” page will appear on the screen.
For the first time, if WHG505 is not using a trusted SSL certificate, there will be a “Certificate Error”,
because the browser treats WHG505 as an illegal website. Please press “Continue to this website” to
continue. The default user login page will then appear in the browser. For more information, please see
Additional Configuration, WHG505 User’s Manual.
If you can’t get the login screen, the reasons may be: (1) The PC is set incorrectly so that the PC can’t
obtain the IP address automatically from the LAN port; (2) The IP address and the default gateway are
not under the same network segment. Please use default IP address such as 192.168.255.xx in your
network and then try it again. For the configuration on PC, please refer to WHG505 User’s Manual,
Appendix A - Network Configuration on PC & User Login.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

C o mmo n Settin g s
< Setup Wizard >
WHG505 provides a Setup Wizard for quick
configuration. To quickly configure WHG505 by
using the Setup Wizard, click on the Setup Wizard
button to start the configuration process.
Step 1: General
•Enter a new password in the New Password
field, and re-enter it again in the Verify
Password field (a maximum of 20 characters
and no spaces allowed in between).
•Select an appropriate time zone from the Time
Zone drop-down list box to set up the system
time.
•Click Next to continue.
For security concern, it is strongly
recommended to change the
administrator's password
Step 2: WAN1 Interface
For setting up both wired WAN and wireless LAN
functions:
•Select a proper type of Internet connection for
WAN1 interface from the following three
available connections: Static, Dynamic, or
PPPoE. Your ISP or network administrator can
advise on the connection type available to you.
Below depicts an example for Dynamic.
•Click Next to continue.
Step 3: Local User Account (Optional)
New local accounts can be created and added into
the database via this optional function. If local user
accounts are not required, click Skip to go directly to
Step 4. However, It is recommended to create at
least one local user account in order to verify the
system‘s readiness upon completion of this Setup
Wizard.
•Enter the Username (e.g. “testuser) and
Password (e.g. “testuser”) to create a new local
account.
•Click Next to continue.
•More local accounts can be added by clicking the
Back button in Step 4.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

Step 4: Confirm and Restart
•Click Finish to save current settings and restart
the system.
•A confirmation dialog box will then appear. Click
OK to continue.
•A Confirm and Restart message will appear on
the screen during the restarting process. Please
do not interrupt the system until the
Administrator Login Page appears.
Note:
The system is trying to locate a DNS
server at this stage. Therefore, a
longer startup time is required if the
configured DNS cannot be found.
•When the following Administrator Login Page
appears, it means the restart process is now
completed.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Quick Installation Guide
W H G5 0 5 Secur e W L A N C o n t r o l l er E N G L I SH

< User Login >
To verify whether the configuration of the new local
user account(s) created via the Setup Wizard has
been completed successfully:
1. Connect a client device (e.g. laptop, PC) to any
LAN Port of WHG505. The device will obtain an
IP address automatically via DHCP.
2. Open a web browser on a client device, access
any URL, and then the default User Login Page
will appear.
3. Enter the Username and Password of a local
user account previously generated via Setup
Wizard (e.g. “testuser@local” as the Username
and “testuser” as the Password); then Click
Login.
Note:
1. WHG505 supports multiple authentication
options including built-in local user database
and external authentication database (e.g.
RADIUS). The system will automatically
identify which authentication option is used
from the full username entered.
2. The format of a full (valid) username is
userid@postfix, where “userid” is the user
ID and “postfix” is the name of the selected
authentication option.
3. Exception: The postfix can be omitted only
when the default authentication option is
used. For example, “LOCAL” is the default
authentication option at this system;
therefore, you may enter either “testuser”or
“testuser@local” in the Username field.
Congratulation!
The Login Success Page will appear after a client
has successfully logged into WHG505 and has been
authenticated by the system.
The appearance of Login Success Page means that
WHG505 has been installed and configured properly.
< Service Zone & AP Management >
4ipnet WHG505 has introduced an important new
concept called “Service Zone”. For how to set up
Service Zones, please refer to the User’s Manual.
WHG505 can centrally manage up to 230 access
points (APs). For how to set up the “AP
Management” feature, please refer to the “AP
Management” section of the User’s Manual.
For further configuration and information,
please refer to the User’s Manual.
P/N: V 1 20 20 0 9 0 8 26
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299

Other 4IPNET Controllers manuals

4IPNET WHG801 User manual

4IPNET

4IPNET WHG801 User manual

4IPNET WHG311 User manual

4IPNET

4IPNET WHG311 User manual

4IPNET WHG713 User manual

4IPNET

4IPNET WHG713 User manual

4IPNET WHG301 User manual

4IPNET

4IPNET WHG301 User manual

4IPNET WHG525 User manual

4IPNET

4IPNET WHG525 User manual

4IPNET APM100 User manual

4IPNET

4IPNET APM100 User manual

4IPNET WHG321 V3.30 User manual

4IPNET

4IPNET WHG321 V3.30 User manual

Popular Controllers manuals by other brands

Toa DI-1616 Specifications

Toa

Toa DI-1616 Specifications

BERGHOF DC2004 User handbook

BERGHOF

BERGHOF DC2004 User handbook

UCS NANO DC manual

UCS

UCS NANO DC manual

AirTurn BT200S operating manual

AirTurn

AirTurn BT200S operating manual

Leroy-Somer R230 A.V.R. Installation and Maintenance

Leroy-Somer

Leroy-Somer R230 A.V.R. Installation and Maintenance

Stephill SSDP30-70 Series User & Fault Finding Guide

Stephill

Stephill SSDP30-70 Series User & Fault Finding Guide

Panasonic EYFR03 Training guide

Panasonic

Panasonic EYFR03 Training guide

Powtier Controls TBC instruction manual

Powtier Controls

Powtier Controls TBC instruction manual

Charles T1 installation guide

Charles

Charles T1 installation guide

ILX Lightwave LDC-3916376 user guide

ILX Lightwave

ILX Lightwave LDC-3916376 user guide

ZIGBEE YPHIX 50208701 installation manual

ZIGBEE

ZIGBEE YPHIX 50208701 installation manual

Vaisala RS41-SG user guide

Vaisala

Vaisala RS41-SG user guide

AGS Merlin 1000S Installation & operation manual

AGS

AGS Merlin 1000S Installation & operation manual

ADLINK Technology PXI -3950 user manual

ADLINK Technology

ADLINK Technology PXI -3950 user manual

Sullair 02250165-411 R01 user manual

Sullair

Sullair 02250165-411 R01 user manual

EMKO EAOM-72F manual

EMKO

EMKO EAOM-72F manual

NENUTEC NEAA 08 Series quick start guide

NENUTEC

NENUTEC NEAA 08 Series quick start guide

Truma Panel EM LED operating instructions

Truma

Truma Panel EM LED operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.