Technical Bulletin
1370 23023
code a.b.s. S.r.l. (Milan) Italy
Lombardia street 310, 20861 Brugherio
Tel. +39 039 839631 - Fax. +39 039 8396349
e-mail:[email protected] - www.absfire.it - Capital 2.000.000
Technical data are subject to modification
for improvements without prior notice
Data Sheet
Code Date Check Rev Pag.
Marine Con.Box 23023 25/05/15 benz 3/benz 1/5
Control Box 23023
for boat or car fire system actuator Usually fixed on the boat dash board
Central unit CPU
Weight: 230 g
WIRING DIAGRAM
Dash board
Remote unit
Weight: 57 g
TECHNICAL DESCRIPTION
CHASSIS IN ABS, IP 65
The central unit and the dash board remote unit are
manufactured with materials immunes to the marine
environment and supplied with seal that guarantee
maximum impermeability.
Furthermore, the chassis ensures adequate heat dissipation
which allows long periods of operation.
Maximum connection distance
-With double insulated cable 60 mt;
-With shielded twisted pair cable 150 mt.
-Very easy to use
Large backlit LCD 16X2
-Language: Italian, English, Franch, German, Spanish.
Compact dimension
Power supply :12Vdc (500 MA) 24Vdc (250 MA)
Output relay :Max 3A Max 3A
Signal input :N.O. N.O.
Microcontroller :Advanced RISC 8bit
Comunication :RS485 half duplex
- Backlit LCD Display 16x2
- Acoustic and optical signal with led.
- Programmable by buttons.
INPUTOUTPUT
Technical specification
Technical Bulletin
1370 23023
code a.b.s. S.r.l. (Milan) Italy
Lombardia street 310, 20861 Brugherio
Tel. +39 039 839631 - Fax. +39 039 8396349
e-mail:[email protected] - www.absfire.it - Capital 2.000.000
Technical data are subject to modification
for improvements without prior notice
Data Sheet
Code Date Check Rev Pag.
Marine Con.Box 23023 25/05/15 benz 3/benz 2/5
Electric wire diagram
Electric actuator
Is fixed on the valve Easyfire®or Firekill®.
R = Monitoring LED resistor 1.8 KΩat 24 V
1
2Connector base
Power supply
selector
12-24Vdc
Technical Bulletin
1370 23023
code a.b.s. S.r.l. (Milan) Italy
Lombardia street 310, 20861 Brugherio
Tel. +39 039 839631 - Fax. +39 039 8396349
e-mail:[email protected] - www.absfire.it - Capital 2.000.000
Technical data are subject to modification
for improvements without prior notice
Data Sheet
Code Date Check Rev Pag.
Marine Con.Box 23023 25/05/15 benz 3/benz 3/5
Technical specification operating Control Box.
Use instruction.
Control Box consist of two units, a central unit CPU with LCD large backlit display
designed to be installed in engine compartments and remote unit to activate and
control the system from the dash board.
The central unit receives activation signal from the remote unit pushing
down simultaneously both buttons for 3 sec (pict. 1).
The central red LED flashes, until the system operated after it stop to flash.
During the discharge, the pressure switch connected to the system will change its condition (it close the contact) and turn on
the red led “EMPTY” permanently, until the system will be reset.
The red led “EMPTY” is switched on even if there are leaks from the cylinder. In this case, call an authorised service
company of ABS.
The yellow led “FAULT” shows an anomaly from the IN1 - IN2 - IN3 - IN4 - IN5, and according to the set delays on the
outputs, it will generate the activation of the OUTPUT OUT1 - OUT2 - OUT3 - OUT4 - OUT5. After activation of the outputs,
the yellow led “FAULT” will switch off, and the red led “EMPTY”, will be switched on.
The green led “ POWER” indicates that the system is correctly operating
and it will be switched off in case of malfunction or discharge.
- Signal input:
IN1 Pressure switch ( N.C.)
IN2 Temperature detector
IN3 Thermosensittive cable
IN4 Remote activation (Button underglass)
IN5 Further alarm remote available
- Output control relay:
OUT1 Electric actuator
OUT2 Solenoid fuel electro valve solenoid fuel tank
OUT3 Closed shutters ventilation of the engine compartment
OUT4 Solenoid gas kitchen system (N.O.)
OUT5 Acoustic indicator
Program CPU
LX Decreases
RX Increases
Send Change screen
Program level 1
Push the button SEND (pict. 2) for 10 sec. until entry in the function level 1.
Select the language with button RX or LX (pict. 3).
Push “SEND” to change the screen.
Push the button RX or LX to enable or disable the system.
Program level 2
At the finish of the program level 1 “end input” push the button RX and LX together
(pict. 3) for 10 sec. until entry in the function level 2.
With button RX or LX can enable or disable the function of level 2.
(pict. 1)
(pict. 2) (pict. 3)
LXSEND RX
Technical Bulletin
1370 23023
code a.b.s. S.r.l. (Milan) Italy
Lombardia street 310, 20861 Brugherio
Tel. +39 039 839631 - Fax. +39 039 8396349
e-mail:[email protected] - www.absfire.it - Capital 2.000.000
Technical data are subject to modification
for improvements without prior notice
Data Sheet
Code Date Check Rev Pag.
Marine Con.Box 23023 25/05/15 benz 3/benz 4/5
FUNCTION LEVEL 2
FUNCTION INPUT 1 : RX Enable -LX Disable
FUNCTION INPUT 2 : RX Enable -LX Disable
FUNCTION INPUT 3 : RX Enable -LX Disable
FUNCTION INPUT 4 : RX Enable -LX Disable
FUNCTION INPUT 5 : RX Enable -LX Disable
FUNCTION OUTPUT 1 : RX Enable -LX Disable
FUNCTION OUTPUT 2 : RX Enable -LX Disable
FUNCTION OUTPUT 3 : RX Enable -LX Disable
FUNCTION OUTPUT 4 : RX Enable -LX Disable
FUNCTION OUTPUT 5 : RX Enable -LX Disable
DELAY OUTPUT 1 : RX Increase from 0 >99 -LX Decrease from 0 <99
DELAY OUTPUT 2 : RX Increase from 0 >99 -LX Decrease from 0 <99
DELAY OUTPUT 3 : RX Increase from 0 >99 -LX Decrease from 0 <99
DELAY OUTPUT 4 : RX Increase from 0 >99 -LX Decrease from 0 <99
DELAY OUTPUT 5 : RX Increase from 0 >99 -LX Decrease from 0 <99
Descriptions that appear on the display
www.absfire.it (immediately after power-up)
OPERATING SYSTEM
SYSTEM DISCHARGE
COLOR SYSTEM STATUS PERFORM
LED DESCRIPTION OPERATION
Dash board led
Status System OK.
Devices are properly
installed and fully functional.
Green
Led
POWER
NOTHING
The system has been activated, the switch
has been activated (and not yet released)
or thermocables are in short circuit.
Yellow
Led
FAULT
Pressurizzed the fire extinguisher
Be sure that there are no leaks or replace
and reinstall the electric actuator.
Red
Led
EMPTY
WARNING SYSTEM FAULT
Low-pressure on the fire extinguisher
or electric actuator damaged
or wires are not connected properly.
Low-pressure on the fire extinguisher or verify the
functionality of the pressure switch with a tester or
electric actuator damaged to be replaced or wires are
not connected properly to be reconnected.
Technical Bulletin
1370 23023
code a.b.s. S.r.l. (Milan) Italy
Lombardia street 310, 20861 Brugherio
Tel. +39 039 839631 - Fax. +39 039 8396349
e-mail:[email protected] - www.absfire.it - Capital 2.000.000
Technical data are subject to modification
for improvements without prior notice
Data Sheet
Code Date Check Rev Pag.
Marine Con.Box 23023 25/05/15 benz 3/benz 5/5
1
2
3
4
5
6
Collegare l’alimentazione ai morsetti 1 e 2.
Collegare l’unità remota ai morsetti
3 - 4 - 5 - 6. Se quest’ultima si trova ad una
distanza compresa tra 1 e 10 metri dalla
unità centrale, collegare inoltre la resistenza
da 2.2 KOhm sull’unità base ai morsetti 3 e 5
come indicato.
Connect battery to terminals 1 and 2
Connect remote unit to terminals
3 - 4 - 5 - 6. If Remote unit is between 1
and 10 meters far from central unit,
Connect also a 2,2 KOhm on base unit
to terminals 3 and 5 as indicated.
Alimentazione
Battery
Unità remota
Remote unit

Popular Controllers manuals by other brands

MICRO-EPSILON C-Box/2A operating instructions

MICRO-EPSILON

MICRO-EPSILON C-Box/2A operating instructions

SMAR CD600 Plus Quick installation guide

SMAR

SMAR CD600 Plus Quick installation guide

OptoSigma GSC-01 user manual

OptoSigma

OptoSigma GSC-01 user manual

Mitsubishi QCPU (Q Mode) user manual

Mitsubishi

Mitsubishi QCPU (Q Mode) user manual

Linak TR-EM-288 quick guide

Linak

Linak TR-EM-288 quick guide

Primex SP6R-LSC user manual

Primex

Primex SP6R-LSC user manual

Jetter JCM-501-E01 user manual

Jetter

Jetter JCM-501-E01 user manual

WEG ECW500 user manual

WEG

WEG ECW500 user manual

DIG 5004-I Four Station owner's manual

DIG

DIG 5004-I Four Station owner's manual

Autoscript WC-IP user guide

Autoscript

Autoscript WC-IP user guide

TIS ADS-4CH-0-10V installation manual

TIS

TIS ADS-4CH-0-10V installation manual

Allegion LCN 8310-815 manual

Allegion

Allegion LCN 8310-815 manual

Wibre 5.0620.19.52 installation manual

Wibre

Wibre 5.0620.19.52 installation manual

Cypress CapSense CY3280-MB quick start guide

Cypress

Cypress CapSense CY3280-MB quick start guide

DINUY KNX RE KNT DA1 Installation

DINUY

DINUY KNX RE KNT DA1 Installation

ModelCraft ECO-Line 20A operating instructions

ModelCraft

ModelCraft ECO-Line 20A operating instructions

Thermaltake CL-O016-PL00BL-A installation guide

Thermaltake

Thermaltake CL-O016-PL00BL-A installation guide

TechnoKiss TERRA Quick starter guide

TechnoKiss

TechnoKiss TERRA Quick starter guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.