manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. A.O. Smith
  6. •
  7. Water Heater
  8. •
  9. A.O. Smith ProMax SL User manual

A.O. Smith ProMax SL User manual

This manual suits for next models

3

Other A.O. Smith Water Heater manuals

A.O. Smith BTP-139 Application guide

A.O. Smith

A.O. Smith BTP-139 Application guide

A.O. Smith GCV/XCV 65/65L User manual

A.O. Smith

A.O. Smith GCV/XCV 65/65L User manual

A.O. Smith GPSX-50L User manual

A.O. Smith

A.O. Smith GPSX-50L User manual

A.O. Smith THR-160 Product information sheet

A.O. Smith

A.O. Smith THR-160 Product information sheet

A.O. Smith DRE Operating instructions

A.O. Smith

A.O. Smith DRE Operating instructions

A.O. Smith Gdhe 50 User manual

A.O. Smith

A.O. Smith Gdhe 50 User manual

A.O. Smith DSE-120-24 Instruction Manual

A.O. Smith

A.O. Smith DSE-120-24 Instruction Manual

A.O. Smith HPW-60AT User manual

A.O. Smith

A.O. Smith HPW-60AT User manual

A.O. Smith Power-Vent BTV-100 User manual

A.O. Smith

A.O. Smith Power-Vent BTV-100 User manual

A.O. Smith HSE-SBS-015 User manual

A.O. Smith

A.O. Smith HSE-SBS-015 User manual

A.O. Smith BTC 201 User manual

A.O. Smith

A.O. Smith BTC 201 User manual

A.O. Smith AOS GPHE-50 Application guide

A.O. Smith

A.O. Smith AOS GPHE-50 Application guide

A.O. Smith BFC Cyclone Troubleshooting guide

A.O. Smith

A.O. Smith BFC Cyclone Troubleshooting guide

A.O. Smith BT-100-LP User manual

A.O. Smith

A.O. Smith BT-100-LP User manual

A.O. Smith SGS-28 User manual

A.O. Smith

A.O. Smith SGS-28 User manual

A.O. Smith FVIR Configuration guide

A.O. Smith

A.O. Smith FVIR Configuration guide

A.O. Smith ProMax Direct-Vent GDV-40 Owner's manual

A.O. Smith

A.O. Smith ProMax Direct-Vent GDV-40 Owner's manual

A.O. Smith 186589-004 User manual

A.O. Smith

A.O. Smith 186589-004 User manual

A.O. Smith ELJH-30 User manual

A.O. Smith

A.O. Smith ELJH-30 User manual

A.O. Smith AOSRE50100 User manual

A.O. Smith

A.O. Smith AOSRE50100 User manual

A.O. Smith Cyclone XL 100 Series How to use

A.O. Smith

A.O. Smith Cyclone XL 100 Series How to use

A.O. Smith GCV300 How to use

A.O. Smith

A.O. Smith GCV300 How to use

A.O. Smith Hot Water Storage Tanks T120V User manual

A.O. Smith

A.O. Smith Hot Water Storage Tanks T120V User manual

A.O. Smith 970 Series User manual

A.O. Smith

A.O. Smith 970 Series User manual

Popular Water Heater manuals by other brands

Haier ES8VQ1 (R) null

Haier

Haier ES8VQ1 (R) null

Haier ES35HH1 (R) null

Haier

Haier ES35HH1 (R) null

Haier Little Sea-ox FCD-30 null

Haier

Haier Little Sea-ox FCD-30 null

Kenmore 153.582400 Use & care guide

Kenmore

Kenmore 153.582400 Use & care guide

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

STIEBEL ELTRON

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

clage E-Mini Series Operating and installation instructions

clage

clage E-Mini Series Operating and installation instructions

Toyotomi Oil Miser OM-180 installation manual

Toyotomi

Toyotomi Oil Miser OM-180 installation manual

Bradford White EF Series Service manual

Bradford White

Bradford White EF Series Service manual

Eccotemp 40-H Use & care manual

Eccotemp

Eccotemp 40-H Use & care manual

Dimplex ECSd125-580 Installation and user instructions

Dimplex

Dimplex ECSd125-580 Installation and user instructions

Dux 32FCR6N installation manual

Dux

Dux 32FCR6N installation manual

Noritz N-132M Owner's guide and installation manual

Noritz

Noritz N-132M Owner's guide and installation manual

TESY GCV7/4S 10047 Instructions for use and maintenance

TESY

TESY GCV7/4S 10047 Instructions for use and maintenance

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

Toyotomi

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

Koryo KWHZF15Y user manual

Koryo

Koryo KWHZF15Y user manual

Pentair PSC-14-4-02 Installation and operation manual

Pentair

Pentair PSC-14-4-02 Installation and operation manual

GE 40M06AAG Energy guide

GE

GE 40M06AAG Energy guide

Thermor AEROMAX SPLIT 2 Instructions for use

Thermor

Thermor AEROMAX SPLIT 2 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PROMAX
®SL POWER DIRECT-VENT FEATURES
POWER DIRECT-VENT
POWER DIRECT-VENT DESIGN
ProMax SL Power Direct Vent residential gas models are equipped with FVIR
technology to meet Phase III of the ANSI Z21.10.1 standards for the resistance to
flammable vapor ignition and resistance to lint, dust and oil accumulation tests.
The Closed-combustion two-pipe system draws combustion air from outside
and vents outside the home. The system uses PVC, CPVC or ABS pipe and vents
up to 45 feet with 3" pipe, including one elbow.
SIDE-MOUNTED RECIRCULATING TAPS
For installation with combination space heating/potable water heating
applications (such as the ProMax XL Heat Exchanger) or any system requiring
a recirculating hot water loop.
INTELLI-VENT®GAS CONTROL
Equipped with silicon nitride hot surface igniter and advanced electronics for
precise control of water temperature and simplified system diagnostics.
HEAT TRAP NIPPLES
Standard on all models.
QUIET MODULAR BLOWER
With 110/120 Volt electrical system (rating 3 amps or less), with 6-foot cord, standard
3-prong male connector.
A. O. SMITH DYNACLEAN™DIFFUSER DIP TUBE
Reduces lime and sediment buildup, maximizes hot water output. Made from long-lasting PEX
cross-link polymer.
GREEN CHOICE™GAS BURNER
Patented “Eco-Friendly” design reduces NOx emissions by up to 33%, complies with Southern
California and Texas requirements.
MAGNESIUM ANODE RODS
Provides long-lasting protection against tank corrosion.
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
A. O. SMITH PERMAGLAS®GLASS COATING
Protects steel tank from rust.
FACTORY-INSTALLED TEMPERATURE & PRESSURE (T&P) RELIEF VALVE
CODE COMPLIANCE: U.B.C., S.B.C.C., C.A.B.O., H.U.D., B.O.C.A. NATIONAL
CODES, ASHRAE/IES 90.1-1999 AND 2004 NAECA
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANS Z21.10.1 standards governing storage-type water heater.
6-YEAR LIMITED TANK AND PARTS WARRANTY
For complete information, consult written warranty or A. O. Smith Water Products Company.
* Intelli-Vent®is a registered trademark of the Emerson Electric Company
L.1
Residential Gas Water Heaters
www.hotwater.com
Revised August 2007R ARGSS00407
180000 ARGSS00407.indd 1 8/17/07 4:14:03 PM
For Technical Information and Automated Fax Service, call 800-527-1953.
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised August 2007R ©2007 A. O. Smith Corporation Printed in U.S.A.
RESIDENTIAL Gas Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
www.hotwater.com
ARGSS00407
MODEL
FIRST
ENERGY
GALLON
BTU BTU RECOVERY
R
DIMENSIONS IN INCHES APPROX.
NUMBER
HOUR
FACTOR
CAPACITY
INPUT OUTPUT 90ºF RISE
VALUE
SHIPPING
RATING PER HOUR PER HOUR GALLONS ABCDEFGH
WEIGHT
GALLONS NATURAL NATURAL PER HOUR (LBS.)
GPD-40L 73 .59 40 40,000 † 30,000 † 41 16 57 48-1/2 21 15 8 42 17 42 224
GPDX-50L 80 .58 50 65,000 † 47,500 † 64 16 69-1/2 61 21 15 8 54-1/2 17 54-1/2 232
GPD-75L 123 .53 75 70,000 † 53,200 † 72 16 71-1/2 61-1/2 26-1/4 15-1/2 8 54-1/2 17 54-1/2 352
GPDX-50L is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
GPD-75L is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
Recovery capacity based on actual performance tests.
Water Connections – 3/4" Male on all models.
† Propane Gas – 40-Gallon: 36,000 BTU input, 27,360 BTU output.
50-Gallon: 60,000 BTU input, 43,800 BTU output.
75-Gallon: 65,000 BTU input, 49,400 BTU output.
IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS
Read and follow requirements shown in the Installation Manual for ProMax®Power
Direct-Vent Gas water heaters dealing with type, placement and length of vent pipe
and vent termination, as well as clearances required to provide adequate
combustion and proper ventilation.
OPTIONAL CIRCULATING LOOP CONNECTION ASSEMBLIES
Sold separately. Kit Number 900152-2 includes two extended PEX lined nipples for side
port connections. Kit Number 900260-4 is same as 900152-2, plus two
di-electric unions and 2 brass isolation valves. For use with systems that have a check
valve in the air handler or recirculating lines.
IMPORTANT:
SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING
SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER
HEATERS
OPTIONAL (DELUXE) ROUND HORIZONTAL
VENT TERMINATION KIT
Part Number 9002749
OPTIONAL (DELUXE) SQUARE HORIZONTAL
VENT TERMINATION KIT
Part Number 9003328
F
E
C
D
3" VENT
4"
11.5" MIN.
FROM TOP OF
HEATER TO
CENTER LINE
OF FLUE
1/2" GAS
CONNECTION
BA
G
H
POWER DIRECT-VENT
Maximum hydrostatic working pressure: 150 psi
70
105
130
.60
.58
.58