Installation and Commissioning of the ArcticRevolution 75B must only be
undertaken by a qualified and trained individual. Children and persons with
reduced physical and mental capability must be supervised when using the
equipment.
Sanitising of the ArcticRevolution must only be undertaken by a qualified and trained
individual
Commissioning & Safe Usage
Please read the following instructions before installing the Arctic Revolution 75B
•Ensure that the ArcticRevolution 75B is connected to a potable mains water supply and
that Water Regulation Standards are met when connecting to the mains
•The AA Installation Rail meets Water Regulation Standards and contains all necessary
components to connect the ArcticRevolution 75B to the mains
•Water Regulations require that the mains connection point includes a non-return valve with
isolating tap, to avoid back flushing of water from the Arctic Revolution 75B into the mains
•Leave a 15cm gap all around the Arctic Revolution 75B to provide good ventilation
•Install the Arctic Revolution 75B on a flat surface to avoid vibration and noise
•Install away from a heat source which could affect the unit’s cooling capacity
•Avoid freezing conditions which could rupture the pipes
•Never tilt the unit over 45 degrees when carrying or storing
•Wait for an hour after transport before installing to allow the coolant to settle
•Fill water reservoir with water before the unit is powered up to avoid damage to the refrigeration
element
•Always turn the electricity off before removing any panels
•Always turn the water off at nearest stop cock before working on the Arctic Revolution 75B
•When not in use for an extended period: Turn the mains water and power off
•Sanitise the Arctic Revolution 75B before first use and follow the sanitising instructions
•Before switching the power on, purge any air in the system by discharging water from the taps.
This also ensures that the cold-water tank is filled with water
•Check all water connections for leakage and ensure that all electrical connections are safe,
before commissioning the Arctic Revolution 75B
Sanitising the Arctic Revolution 75B
Please read the following instructions before sanitising the Arctic Revolution 75B
•Switch the power off
•Turn the mains water off
•Remove the filter and replace with an empty AA First filter housing
•Pour the sanitising fluid into the empty filter housing
•Turn the mains water back on
•Open the taps to flush the sanitising liquid into the water tank and pipes
•Leave standing for 10 minutes and then flush through with water to remove all traces of the sanitising
solution
•Sanitise in strict accordance with WHA (Water Dispenser & Hydration Association https://twha.co.uk)
guidelines using only tested and therefore endorsed sanitising product

3
Water Filtration
AMBIENT WATER OUTLET
SOL-VALVE
CHILLED WATER OUTLET
SOL-VALVE
FLOAT
VALVE
CHILLED WATER INLET
SOL-VALVE
AA INSTALLATION RAIL
COOLING
MODULE
SAFTEY
VALVE
CHILLED/AMBIENT
WATER FAUCET

4
Available Factory Retrofits
•The ArcticRevolution 75B is already pre-configured to allow for a Contactless retrofit. Contactless
dispensing avoids hand to tap contamination.
•The ArcticRevolution 75B can be supplied with KLARAN UVC LED automatic Sanitization. KLARAN
destroys 99.99% of Waterborne Bacteria & Viruses known to cause health problems.
•For extremely sensitive areas in Hospitals, Hospices etc. the ArcticRevolution 75B can be equipped
with Contactless dispensing and KLARAN UVC LED Sanitization.
Troubleshooting
Problem Solution
•Check if the power and water are turned on
•Has too much cold water been consumed and the Arctic
Arctic Revolution 75B
does not work, or
decreased water
production
Revolution 75B has not had time to recover?
•Is the unit too close to a strong light, heat source or too
confined in space?
•The filter is blocked and needs replacing
•Check external and internal tubing’s for kinks or blockages
•Is the mains water pressure too low (below 147KPa)
Noise and vibration •The cooler stands on an uneven surface
Water leakage •Check water connection from the mains
•Check for internal leaks due to burst connection
Unpleasant water taste or
odor
•This can happen if the Water Cooler has been unused for
some time or if the Sanitising Regime has failed. The solution
is almost always to sanitise the Cooler
Warning
•This appliance is provided with refrigerant gas, ISOBUTANE(R600a).
•This appliance must be transported and moved, taking maximum care to ensure that it is not excessively
struck or shaken. Failure to do observe the above rule could put the appliance out of service.
•Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
•Do not damage the refrigerant circuit. if damage to the refrigerating circuit, with possible outflow of refrigerating
gas, could create risks of explosion caused by external sparks or flames.
•Do not, on any account, run the appliance if it seems to be damaged.
•In case of damage, contact the Service Centre, ventilate the room where the appliance is located, and avoid
flames or jobs on the appliance.

5
Water is FOOD and Water Coolers must be maintained to a safe and
hygienic Food standard. The Water Cooler Associations (WHA) demands
that all makes and types of Coolers / Fountains must be regularly sanitised,
using approved sanitising solutions/techniques.
The Arctic Revolution 75B Service, Maintenance & Recycling
HYGlENE
1. The Arctic Revolution 75B must be sanitised and the filter exchanged every 6 months
2. All Coolers should be sanitised prior to commissioning
3. Sanitising should be in accordance with the WHA (Water Dispenser & Hydration
Association, https://twha.co.uk) guidelines
ELECTRICAL SAFETY
4. All electrical connections should be checked at installation
5. Check the flex cable for any visible damage and ensure that the Arctic Revolution 75B is not
Installed on top of the cable
6. The Arctic Revolution 75B should be PAT tested by the Distributor if the equipment has been
removed by him from a site and before re-installing it at another site. The user should PAT
test the equipment annually.
7. It is recommended that points 4. 5. and 6. Form part of the regular routine maintenance
WATER CONNECTIONS
8. Always turn the electricity off before removing any panel
9. Always turn the water off at the nearest stop cock before working on the Arctic Revolution 75B
10. When not in use for an extended period, turn the mains water and power off. If it is left
unused for less than 2 weeks, flush 5 liters of fresh water through the tap. If left unused for
longer, sanitise the Arctic Revolution 75B
11. It is recommended that all water connections are checked as part of the regular routine
maintenance
WEEE RECYCLING & LABELLING
12. All Water Coolers should be recycled at the end of their life according to WEEE Regulations.
The ArcticRevolution 75B must show the CE and UKCA logos to confirm electrical safety,
RoHS logo (Restriction of Hazardous Substances) as proof that the materials used comply
with the rigorous RoHS legislation and the Wheeled bin symbol to confirm that the
ArcticRevolution 75B must be recycled under WEEE regulations.

6
Dispensing Chilled or Ambient Water
Dispensing Ambient Water
•Select Ambient Water Selection Button and then press the Dispensing Button to dispense
Ambient Water. When you remove your finger from the Dispensing Button, dispensing stops.
•The dispensing indicator in the center of the panel will pulsate in white during dispensing.
Dispensing Chilled Water
•Select Cold Water Selection Button and then press the Dispensing Button to dispense
Cold Water. When you remove your finger from the Dispensing Button, dispensing stops.
•The dispensing indicator in the center of the panel will pulsate blue during dispensing.
Dispensing Using Contactless Option
•Place your hand 5 to 10cm in front of the contactless sensor to dispense.
Infra Red Sensor for
Cold water dispensing
(Left side)
Infra Red Sensor for
Ambient water dispensing
(Right side)
Cold Water
ON LIGHT
Dispensing
Indicator Light
White = Ambient
Blue = Cold
Ambient Water
ON Light
Cold Water
Selection Button
Touch this button
to select cold water
Dispensing Button
Press the dispensing button
to dispense cold or ambient water
Ambient Water
Selection Button
Touch this button
to select ambient water

7
Caution
Children and persons with reduced physical and mental capability must be
supervised when using the equipment.
Arctic Revolution 75B
Product Name Ambient & Chilled Water Cooler
Model Name WCPTC 75B WCPTC 75BC
Description
Table Top
Ambient & Chilled
(Black)
Table Top
Ambient & Chilled
Contactless (Black)
Dimensions (mm) 373(H) x 240(W) x 488(D)
Weight Approx.13kg
Integrated Cup Holder No
Hygiene Guard Yes
General Specifications
Power supply 220-240V / 50hz
Power cable UK 3 pin plug
Compressor CSB035NKMG
Condenser Table Top FIN COIL TYPE FAN ASSISTED
Refrigerant R-600a
Direct chill/Pressure tank Stainless Steel, 0.9 liter
Side panels ABS
Front & Top panels ABS
Display light LED
Cold Water Temperature About 4℃to 12℃depending on inflow
temperature and use
Recommended Chilled Water 10 ltr/day
This manual suits for next models
2
Table of contents
Other AAFIRST Water Dispenser manuals
Popular Water Dispenser manuals by other brands

IBC Water
IBC Water AST0715MP-960 Installation & operating instructions

Lancaster Water Treatment
Lancaster Water Treatment X FACTOR LX15 Series Installation, operating and service manual

Elkay
Elkay EMABF8 Series Installation & use manual

Oasis
Oasis Osmosis Home installation manual

Monarch Water
Monarch Water ULTIMATE MINI AQUA HE install guide

Haier
Haier HLM-109B instruction manual