AAS Advantage DKE 26-100sg Technical specifications

page 1
AMERICAN ACCESS SYSTEMS, INC.
ADVANTAGE DKE
INSTALLATION AND PROGRAMMING
INSTRUCTIONS
MODEL
26-100sg
PLEASE READ BEFORE USING THIS EQUIPMENT
Technical Support: 303-799-9757 Monday thru Friday 8:00 a.m. to 5:00 p.m.
MST
Rev b

page 2
AAS 2-Year Limited Warranty
What item(s) this warranty applies to:
American Access Systems "Advantage DKE" access controls.
What is covered:
Any defect in materials or workmanship.
For how long:
Two years from date of purchase.
What we will do:
If your AAS product is defective and returned within 2 years of the date of purchase, we will
repair it or, at our option, replace it at no charge to you. If we repair your AAS product, we may
use new or reconditioned parts. If we choose to replace your AAS product, we may replace it with a
new or reconditioned one of the same or similar design. The repair or replacement will be
warranted for (a) 90 days or (b) the remainder of the original two year warranty period, whichever
is longer.
Limitations:
Implied warranties, including those of fitness for a particular purpose and merchant ability (an
unwritten warranty that the product is fit for ordinary use), are limited to two years from date
of purchase. We will not pay for loss of time, inconvenience, loss of use of your AAS product,
service calls, or property damage caused by your AAS product or its failure to work, or any other
incidental or consequential damages. Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above
exclusions or limitations may not apply to you.
What we ask you to do:
To get warranty service for your AAS product, you muse provide proof of the date of purchase.
Contact the original dealer or installer of the product and return your AAS product along with the
receipt to them. If you have problems locating the dealer or installer contact American Access
Systems at (303) 799-9757 and we will direct you to an authorized dealer or distributor of
American Access Systems products. If you ship your AAS product, you must prepay all shipping
costs. We suggest that you retain your original packing material in the event you need to ship
your AAS product. On return, include your name, address, phone number, proof of date of purchase,
and a brief description of the operating problem.
What this warranty does not cover:
This warranty does not cover defects resulting from accidents, damage while in transit,
alterations, unauthorized repair, failure to follow instructions, misuse, fire, flood, or acts of
God. Nor do we warrant your AAS product to be compatible with any particular external device or
peripheral. If your warranty has expired on your AAS product or if your product is NOT covered
contact your dealer or installer for advice on whether we will repair your AAS product and other
repair information, including estimated repair costs and other charges. We, at our option, may
replace rather than repair your AAS product with a new or similar design if the damage to the unit
is severe or extensive.
This warranty is the only one we give on this product, and it sets forth all our responsibilities
regarding your AAS product. There are no other express warranties.
State Law rights:
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
AMERICAN ACCESS SYSTEMS, INC.
7079 SOUTH JORDAN ROAD / UNIT 6
ENGLEWOOD, CO. 80112
PH: (303) 799-9757
FAX: (303) 799-9756
Serial #

page 3
PARTS CHECKLIST
Enclosed with this box you should have the
following items.
Qty Description
1 Control Station
2 Security Screws
1 Installation Instructions
If any of the above items are missing
from this box, contact American Access
Systems
TOOLS YOU WILL NEED
Wire nuts or appropriate connectors
Wire strippers
Wire cutters
Standard2x4electrical box

page 4
STEP 1-MOUNTING THE UNIT
Page 3 tells you what tools and instruments you will need to install your unit and presents a parts check list. Make
sure to have all the tools listed. Upon opening the box, check off the items enclosed with the unit. If any items are
missing from your unit, contact American Access Systems immediately.
The ADV-100sg is designed to mount in a standard 2 x 4 electrical box. Two security screws are provided to prevent
tampering. American Access Systems can provide the proper tool to install these screws for a additional cost. They
are standard (snake eyes) screws.
Once you have made your connections, fold the wires into the box and secure the keypad being
careful not to pinch any wires between the box and keypad panel.
STEP 2-SYSTEM CONNECTIONS
Study the WIRING COLOR CODE chart below and then proceed to the hookup steps.
(TABLE 1)
WIRING COLOR CODES
WHITE 12-24VOLTS
WHITE ACorDC
LATCH CONTACTS
BROWN RELAYCOMMON
ORANGE NORMALLY OPEN
BLUE NORMALLYCLOSED
HOOKUP STEPS
(A
). Your DKLP control unit operates on 12 to 24 volts AC or DC. Measure the voltage from the power source to
make sure it falls within these tolerances. Locate the two white wires on the circuit board and with the power off
connect them to a constant power supply.
(B). Connect the device to be controlled to the appropriate control leads of the ADV-100 (See above diagram).
(C). Double Check your connections. When you are sure that everything is hooked up correctly, apply power to the
unit. A BEEP should be heard when you press a key on the keypad.

page 5
THE MASTER CODE AND ACCESS CODES
Your unit may be programmed with 100 multiple (4 digit) ACCESS CODES . The MASTER CODE is a 4 digit
programmable code used for accessing the program mode. Note: The 1251 master code will not activate the relay
and open the access device.
SETTING OR RESETTING THE MASTER CODE
To set or reset the master code back to the factory default of 1 2 5 1 should you ever loose or forget you master code.
To do this follow these steps: (SEE PAGE 7 FOR LOCATION DIAGRAM)
(1). Disconnect power from the unit by disconnecting power from circuit board.
(2). Reconnect power while holding down the PROGRAM/RESET button.
(3). A single keybeep will be heard from the unit indicating that the master has been reset
GOODBEEPS AND ERRORBEEPS
A standard beep will be heard each time a key is pressed. A “GOODBEEP” is represented by a series of quick
beeps in succession. An “ERRORBEEP” is represented by a single long beep.
THE IDLE MODE
The idle mode is the normal mode of operation. When in this mode the unit sits and waits for data from the keypad.
If a key is pressed from the keypad, you will have approximately 3 seconds between each keypress before the unit
resets.
THE PROGRAM MODE
The program mode is the mode of operation in which you will enter/change your access code. Upon entry, a
GOODBEEP will heard. A GOODBEEP will also be heard when you exit the program mode unless a keypress
timeout occurs in which case you will receive an ERRORBEEP. The program mode is accessed by entering the
“MASTER CODE” from the keypad. If the master code is valid, you will receive a GOODBEEP from the unit. In
this mode you will have approximately 15 seconds between keypresses. If this time is exceeded, you will receive an
ERRORBEEP and the unit will exit the program mode and return to the idle mode. To exit the program mode at any
time, press #.
THE * AND # KEYS
The * and # keys serve specific functions while in the idle or program mode. The * key is always the clear key. You
should use this key if you make an entry error. The # key also serves as the clear key in the idle mode. In the
program mode however, it serves as the exit key and will at any time when depressed, exit you from the program
mode.
PROGRAMMING
A person desiring a access to the program mode will enter the present MASTER CODE. If the master code is valid a
GOODBEEP will be heard prompting the person to enter a number corresponding to the SUB-MODE, eg.
(MASTER CODE) + (Number corresponding to Sub-Mode). Once in the program mode the individual will have
approximately 15 seconds between keypresses or the unit will sound an ERRORBEEP and exit the program mode.
NOTE: An access code log sheet is provided on page 8 which can be photo-copied. A good source for access
codes is the phone book or the last 4 digits of social security numbers. Note: The Master Code will not activate
the relay!
SUB-MODES
“1”
Sub-Mode 1 (Enter New Access Codes)
To enter new access codes enter the MASTER CODE, followed by 1, then enter each new ACCESS CODE you wish
to program into the unit.
(MASTER CODE) + 1 + (ACCESS CODE) + (ACCESS CODE) etc... (# to exit)

page 6
Should you make an entry error, simply press the * key and re-enter the correct data. You may continue entering
access codes until the memory is full or the # is pressed. You may select any 4 digit access code that is not already in
use by the system. The unit will respond with a GOODBEEP with the acceptance of each new access code. If you do
not receive a GOODBEEP after the entry of an access code, you must select a new access code as it is already in use
by the system. When the memory becomes filled, you will receive a GOODBEEP indicating the acceptance of the
last access code
entered and then the unit will sound an ERRORBEEP and automatically exit you from the program mode.
NOTE: You will not be able to enter this mode if memory is full and will receive an ERRORBEEP.
“2”
Sub-Mode 2 (Delete Access Codes)
To delete any access code from memory enter the MASTER CODE, followed by 2, and then each access code to be
deleted
(MASTER CODE) + 2 + (CODE TO BE DELETED) + (NEXT CODE TO BE DELETED) etc... (# to Exit)
Should you make an entry error, simply press the * key and re-enter the correct data. You may continue deleting
access codes in a successive manner. The unit will respond with a GOODBEEP with the successful deletion of each
access code. If you do not receive a GOODBEEP the access code entered could not be found in memory and the unit
will wait for you to enter another code to be deleted.
“3”
Sub-Mode 3 (Change Master Code)
To change the master code enter the PRESENT MASTER CODE, followed by 3, and then the NEW MASTER
CODE.
(PRESENT MASTER CODE) + 3 + (NEW MASTER CODE)
Should you make an entry error, simply press the * key and re-enter the correct data. You may select any 4 digit code
as your new master code that is not already in use by the system. The unit will respond with a GOODBEEP upon
acceptance of the new master code and automatically exit from the program mode. If the unit does not respond with a
GOODBEEP, you must select a different code as it is already in use by the system.
“4”
Sub-Mode 4 (Set Relay Output Time from 1/2 to 9 seconds)
To set the relay output time in seconds enter the PRESENT MASTER CODE, followed by 4, and then the relay
output time in seconds. NOTE: “0” = 1/2 seconds.
(PRESENT MASTER CODE) + 4 + (RELAY OUTPUT TIME)
Should you make an entry error, simply press the * key and re-enter the correct data. You may enter any single digit
value corresponding from 1/2 to 9 seconds of total length output time. Please note that when you enter “0”, the output
time is set to 1/2 seconds.
“5”
Sub-Mode 5 (Set Latch Code)
EXPLANATION: The Latch Code toggles the state of the main relay (A) of the circuit board. The red LED will
light if the relay is in the latched position. The latch code is useful in applications where the gate is desired to hold
open. If the operator's close circuit is controlled by loops, timers, etc., they will be overridden by the latched state of
the relay and the gate will hold open. An "OPEN-OVERRIDE" circuit must exist in the operator in order to utilize
this function. If your gate cycles when this code is entered, your operator is not set up to utilize this function. Your
local dealer or distributor should be able to assist you if you have any specific questions.

page 7
To program or change your latch code enter the following;
(MASTER CODE) + 5 + (LATCH CODE)
Should you make a code entry error, simply press the * key and enter the correct code. You may select any 4 digit
latch code you wish. If you receive an ERROR, you must select another code as it is already in use. The unit will
respond with a GOOD BEEP with the acceptance of the new Latch Code and you will be exited from the program
mode. NOTE: On gates with a timer to close the “TIMED DURATION” starts when
the latch code is released.
“0”
Sub-mode 0 (Clear memory)
!!!! WARNING ALL ACCESS CODES WILL BE DELETED !!!!
To delete all access codes from memory enter the MASTER CODE, followed by 0, and the re-enter the MASTER
CODE.
(MASTER CODE) + 0 + (MASTER CODE)
Should you make an entry error, simply press the * key and re-enter the correct data. If the second entry of the
master code is correct there will be a short pause before a GOODBEEP is heard and then the unit will automatically
be exited from the program mode. If the second entry of the master code is incorrect, the unit will still respond with
a GOODBEEP indicating that it is exiting the program mode however, there will be no pause on the GOODBEEP and
the memory will not be erased.
NOTE: It should not generally be necessary to erase all access codes from memory unless codes are forgotten
and are occupying necessary memory space. A good log and maintenance of access codes should prevent this
from ever needing to be done.

page 8
30-023A Circuit Board Layout
MEMORY
CHIP
BUZZER
RESET
SWITCH
POWER
HARNESS
RELAY

page 9
PAGE_____OF_____
ACCESS CODE LOG SHEET
Master Code________________
ACCESS CODE NAME

page 10
NOTES:

page 11
NOTES:

page 12
American Access Systems
Inc.
7079 South Jordan Road
#6
Englewood, Co. 80112
Sales: 1-800 541-5677
E-mail: sales@americanaccess.com
Customer Service: 1-303-799-9757
E-mail: customerservice@americanaccess.com
Tech-Support: 1-303-799-9757
Table of contents