In the Box
IXM INSTALL KIT
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
INVIXium
Metal Mounting
Plate
Earth Ground Wire
Metal Mounting
Plate Screw
(qty 1)
Wall Mounting Screws
(qty 4)
Micro USB Extension
Cable (4 ft/1.2m)
Wired Back Cover
SENSE 2 & TOUCH 2 Only
Hex Key
Dolphin Crimps
(qty 12)
USB Cover Screw
(qty 1) Gangue Box
Mounting Screws
(qty 2)
Snubber Diode
Ferrite Core
(Selected variants only)
Getting Started
1Remove the Mounting Plate, Wired Back
Cover and Screws from the IXM INSTALL KIT.
2Install the Mounting Plate at the desired
location. Invixium recommends 120 cms
from the floor to the bottom of the device.
3Make the necessary connections to the Wired
Back Cover (refer to Get Wired Pages).
4Unscrew and remove the Temporary Back
Cover from the device and connect the
Wired Back Cover using the same screws.
5Hang your device on the Mounting Plate
and secure it on the bottom with the screw
provided.
Get Wired Glossary
ACP
COM
DAC
EGND
GND
LED
NC
NO
RLY
RX
SGND
SPI
SPO
TX
WDATA
WGND
VIN+
VIN-
Access Control Panel
Common
Door Access Control
DSP Door Strike Power
Earth Ground
Ground
Light Emitting Diode
Normally Closed
Normally Open
Relay
PoE Power over Ethernet
Receiver
Signal Ground
Specific Purpose Input
Specific Purpose Output
Transmitter
Wiegand Data
Wiegand Ground
Power (12VDC)
Power Ground
Top Connector
Bottom Connector
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
Get Wired Top Connector
Wire Color
White/Red
Grey
Grey/Red
Brown
Yellow
Black/Yellow
White/Purple
Purple/Yellow
Blue/White
Black/White
Wire Color
Orange/Yellow
Yellow/Green
Green/Orange
Black/Orange
Yellow/Cyan
Cyan/Brown
Brown/Yellow
Black/Cyan
Orange
Purple
Label
RLY_NC
RLY_COM
RLY_NO
ACP_LED1
ACP_LED2
ACP_LED_GND
DAC_IN1
DAC_IN2
DAC_IN3
DAC_GND
Label
SPO_1
SPO_2
SPO_3
SPO_GND
SPI_1
SPI_2
SPI_3
SPI_GND
DAC_OUT
DAC_DSP
Wire WirePin(s)
1
3
5
7
9
11
13
15
17
19
Pin(s)
2
4
6
8
10
12
14
16
18
20
Get Wired Bottom Connector
Wire Color
Red
Black
Green/Yellow
RJ45
Receptacle
Wire Color
Orange/White
Purple/White
Black/Red
Blue
Blue/Black
Green/White
White/Black
Green
White
Black/Green
Label
VIN+
VIN-
EGND
TCP/IP
Label
RS232_RX
RS232_TX
SGND
RS485+ (B)
RS485- (A)
WDATA_IN0
WDATA_IN1
WDATA_OUT0
WDATA_OUT1
WGND
Wire WirePin(s)
1
3
5
9,11,13,
15,17,19
Pin(s)
2
4
6
8
10
12
14
16
18
20
Earth Ground
For protection against Electrostatic Discharge, Invixium recommends the
use of a ground connection between each IXM device to a high quality
Earth Ground available at the install site.
Connect to Earth Ground in the following way:
1
Connect the green and yellow earthing wire from the wired back
cover (bottom connector PIN 5) to the building earthing.
2
Connect the open end of earth ground wire provided in the Install Kit
Box to the building earthing as well.
3
Screw the lug end of the earth ground wire to the metal mounting plate.
4
Ensure all Earth Ground connections are made to each device prior to
turning on the power.
Earthing Wire from
Wired Cover (PIN 5) Building Earthing
Earth Ground
Wire Lug
Earth Ground Connections
Input Voltage
INVIXIUM recommended PoE Injector Specs
90-264 VAC, 60 Hz
Input Current
0.4 A @ 100 VAC
Output Voltage
48 VDC
Output Current
0.32 A
Power
15.36 Watt
Power It Up
When using an external power supply, ensure that the
regulated, filtered and dedicated power source (Safety
tested, FCC/IC/CE certified) provides a minimum of
1.5A @ 12 VDC.
When using PoE, an IEEE 802.3af compliant Active
Midspan Injector is required (sold separately). Refer to
table for Invixium recommended PoE Injector specs.
Full PoE deployments should include a centralized
PoE PSE. Both IEEE 802.3af power transmission
modes (A and B) are supported.
Invixium
recommends the use of battery back up or a UPS
with built-in surge protection.
WARNING: Product Warranty is void if improper power (under or over) is supplied to the device.
Note: MYCRO models do not support PoE.
SENSE 2 and TOUCH 2 models support PoE as well as PoE+.
IXM WEB
Router connected
to LAN/WAN
Ethernet and Wi-Fi
For Ethernet communication, a specific range
of allowable IP addresses can be set for
improved security.
For Wi-Fi communication on TOUCH 2
(selected models only), 802.11 b/g/n protocols
are supported. DHCP is enabled as a factory
default. WEP, WPA and WPA2 encryption
options are available.
MYCRO SENSE 2 TOUCH 2
R = 120 ohms for Standard RS-485 Cabling
R = 100 ohms for CAT5/6 Cabling
RS-485 Configuration
For RS-485 networks, ensure that
IXM
devices are wired in a daisy chain configuration,
up to a maximum
of 31 devices. At a baud rate of 9600 bps, make certain that the
maximum cable length is not longer
than 1200 m (4000 ft).
IXM WEB
Bottom Connecter RS-485
SGND (6)
RS-485+ (8)
RS-485- (10)
RS-485 to USB
Converter
MYCRO
SENSE 2
TOUCH 2

Micro USB OTG Cable
(sold separately)
Bottom USB PortMicro USB Cable
Serial Communication and USB
For Serial Communication, IXM devices are equipped with RS-232 and USB capabilities.
Refer to Get Wired Bottom Connector page for RS-232 connections.
The USB port can be used to connect a Flash Drive via Micro USB OTG cable and perform
functions like upgrading firmware, downloading transaction logs and configuration files.
The USB port can also be
used to connect to a
PC running IXM WEB via
Micro USB cable.
Standard 26-Bit Wiegand Format
Custom 35-Bit Wiegand Format
Trailing Parity
Bit (Odd)
Leading Parity
Bit (Even)
Leading Parity
Bit (Odd)
Even Parity
Flex Fields (12 Bits) ID (20 Bits)
Facility Code (8 Bits)
ID (16 Bits)
Trailing Parity
Bit (Odd)
Flex Fields* OtherOdd ParityEven ParityID Bits
*Flex Fields can be Facility Code, Job Code or Company ID Code.
0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 341BIT
P F F F F F F F N N N N N N N N N N N N N N N N PF
P F F F F F F F F F F F F N N N N N N N N N N N N N N N N N N N N PP
Wiegand
IXM devices have the
option to use the
standard 26-bit
Wiegand format or a
custom Wiegand format
(up to 512 bits) to suit
any Access Control
System.
All IXM devices are set
to Standard 26-bit
format as a factory
default.
N P P F O
ACP Connections
Bottom Connector Wiegand
WDATA_OUT0
WDATA_OUT1
WGND
(16)
(18)
(20)
Top Connector LED
ACP_LED1
ACP_LED2
ACP_LED_GND
(7)
(9)
(11)
WDATA_OUT0
WDATA_OUT1
WGND
ACP_LED1
ACP_LED2
ACP_LED_GND
TOUCH 2
ACP_LED signals can be used if available on the Access Control Panel. IXM
devices support up to 2 wires + GND for LED status.
Max Relay rating = 2A @ 24VDC
NOTE: A separate power supply is required for the door strike
DAC Connections (Electric Door Strike)
Snubber Diode
Request
to exit
DAC_IN2
DAC_OUT
DAC_OUT
DAC_IN1
RLY_NO
Door Strike Power Supply
RLY_COM
Electric
Door Strike
Door
Contact
Top Connector
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
(3)
(5)
(13)
(15)
(18)
MYCRO
Max Relay rating = 2A @ 24VDC
NOTE: A separate power supply is required for the door strike
MYCRO
DAC Connections (Magnetic Lock)
Snubber Diode
Request
to exit
DAC_IN2
DAC_OUT
DAC_OUT
DAC_IN1
RLY_NC
Door Strike Power Supply
RLY_COM
Magnetic
Door Lock
Door
Contact
Top Connector
RLY_COM
RLY_NC
DAC_IN1
DAC_IN2
DAC_OUT
(3)
(1)
(13)
(15)
(18)
Max Relay rating = 2A @ 24VDC
Device can supply 500mA@12V
NOTE: This connection diagram is valid for TOUCH 2 and SENSE 2 only
DAC Connections (Device Powers Door Strike)
DAC Connections
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
(3)
(5)
(13)
(15)
(18)
(20)
RLY_NO
DAC_IN1
DAC_DSP
DAC_GND
RLY_COM
DAC_OUT
DAC_OUT
DAC_IN2
Snubber Diode Electric
Door Strike
Door Contact
Request
to exit
TOUCH 2
DAC_DSP
(19)
DAC_GND
+-
Note: If the device is powering a magnetic
lock, please use RLY_NC wire as shown
on the previous page.
Enrollment Best Practices
Incorrect
Pressure
Position
Rotation
Condition
Dry Wet
Too Low Too High
Good
Good
Correct
Preferred Fingers
1. Proper finger placement is crucial for good enrollment score and faster authentication.
2. Place your finger straight on the sensor as shown below, while covering the sensor with the top
third of your finger as shown on the previous page.
Finger Placement Best Practices
Correct
Incorrect
MYCRO SENSE 2 TOUCH 2
1. The location of the card reader on Invixium devices depends on the product model.
2. For MYCRO and SENSE 2, the card reader is located above the sensor cavity, while for TOUCH 2
the card reader is located below the sensor cavity.
3. See below for the correct card placement while using the MYCRO, SENSE 2 and TOUCH 2.
Card Placement
Software Installation
1 Go to www.invixium.com >> IXM WEB >> Get IXM WEB.
2 Follow the instructions on the screen. Enter your details and click submit. You will then be sent
an email with the latest IXM WEB package.
3 Extract the compressed file and run IXM WEB.exe. Invixium recommends
selecting Install for easier installation.
4 When installation is complete, click Exit. The IXM WEB icon will now be
on your desktop.
5 Use the IXM WEB icon to run IXM WEB in your default web browser.
6 Contact [email protected] in case of any issues.
INGUIDE
This is a Quick Start Guide. For a detailed guide please refer
the Invixium Installation Guide.
Enjoy the Experience.
Some features may vary based on device models.
Copyright © 2021, INVIXIUM. All rights reserved.
invixium.com
© 2019 Google Inc. All rights reserved. ChromeTM browser is a trademark of Google Inc.
Firefox logo®is a registered trademark of the Mozilla Foundation.
Windows®, Internet Explorer®and Edge®are trademarks of the Microsoft group of companies.
Safari®is a trademark of Apple Inc.
P/N XAD-00E-257-01G
For technical or customer support issues, please
contact your Local Authorized Reseller first.
Visit the Customer Portal for more Invixium resources at
www.invixium.com/support
Contact Invixium Support at:
+1 844 INVIXIUM (468 4948)
invixium_support
This manual suits for next models
2
Table of contents
Other Invixium IP Access Controllers manuals