LeeLen 8 Series User manual

1
InstallationManual
V1.0
Xiamen Leelen Technology Co., Ltd.
Address: 65 Sunban South Rd., Jimei North Industrial Zone, Xiamen, China
Tel.: 0086-592-6157677
Fax: 0086-592-6299688
Website: en.leelen.com

Contents
Foreword.......................................................................................................................................................................1
1.Construction manual..................................................................................................................................................3
1.1 System overview.............................................................................................................................................3
1.1.1 Description of digital building intercom system..................................................................................3
1.1.2 Main functions and features.................................................................................................................3
1.1.3 Topological graph and description of overall system architecture.......................................................3
1.2 Description of cables.......................................................................................................................................5
1.2.1 Line configuration................................................................................................................................5
1.2.2 Requirements for network cables.........................................................................................................6
1.3 Requirements for pipeline construction..........................................................................................................7
1.3.1 Requirements for pipeline solution......................................................................................................7
1.3.2 Requirements for pipe material solution..............................................................................................8
1.3.3 Requirements for system environment.................................................................................................8
1.3.4 Network configuration environment....................................................................................................8
2. Installation manual....................................................................................................................................................9
2.1 Installation attentions......................................................................................................................................9
2.2 Outdoor station..............................................................................................................................................10
2.2.1Appearances and main parameters of outdoor stations......................................................................10
2.2.2 Installation of outdoor station ............................................................................................................12
2.2.3 Instruction on device wiring interface................................................................................................14
2.3 Indoor stations...............................................................................................................................................17
2.3.1Appearances and main parameters of indoor stations........................................................................17
2.3.2 Installation of Indoor stations.............................................................................................................18
2.3.3 Instructions on device wiring interfaces.............................................................................................19
2.4 Networking and intermediate devices...........................................................................................................23
2.4.1Appearances and main parameters.....................................................................................................23
2.4.2 Device installation..............................................................................................................................25
2.4.3 Instructions of device wiring ............................................................................................................29
2.5 Center Guard Unit (model No.5) ..................................................................................................................32
2.5.1Appearances and main parameters.....................................................................................................32
2.5.2 Desk top installation of the device.....................................................................................................32
2.5.3 Instructions on device wiring.............................................................................................................33
3. Commissioning manual ..........................................................................................................................................33
3.1 Precautions for commissioning.....................................................................................................................33
3.2 Commissioning flow.....................................................................................................................................34
3.3 Parameter planning .......................................................................................................................................34
3.3.1 Sub-network division.........................................................................................................................34
3.3.2 Planning of the call number of a device.............................................................................................36
3.3.3Application cases................................................................................................................................38
3.4 Description of commissioning of guard unit.................................................................................................41
3.4.1 Necessary parameters to be set ..........................................................................................................41
3.4.2 Parameter setting method...................................................................................................................41
3.5 Instructions on commissioning of outdoor stations.......................................................................................42

3.5.1 Instructions on parameters to be set on the outdoor stations..............................................................42
3.5.2 Instructions of parameter settings ......................................................................................................42
3.5.3 Device commissioning steps..............................................................................................................48
3.6 Instructions on indoor station commissioning ..............................................................................................48
3.6.1 Necessary parameters to be set of the indoor station .........................................................................48
3.6.2 Indoor station setting method.............................................................................................................49
3.6.3 Test steps after device parameter setting............................................................................................53
3.7 Web setting parameters (parameter setting of Model No.8 and Model No.15 Outdoor Station)..................53
3.8 Installation and commissioning of management software............................................................................56
3.9 Commissioning steps of the main platform ..................................................................................................56

1
Foreword
Xiamen Leelen Technology Co., Ltd. is the biggest domestic supplier of building intercom and digital /system
devices. In this industry, only Leelen won the honor of “China Top Brand” and “Famous Trademark of China.”
Leelen ranks third by virtue of its comprehensive strength in China’s building intercom industry.
Leelen has nearly a dozen subordinate enterprises such as Leelen Investment Company, Leelen Technology Co.,
Ltd., Leelen Electric Control Technology Co., Ltd, Leelen High Voltage Electric Co., Ltd, SafeHouse Electronic
Science and Technology Co., Ltd, and Zhonglin Machine Co., Ltd. It has 37 subsidiary companies, offices and
after-sales service sites which are spread all over China. Leelen has an industrial park which covers an area of
nearly 110,000m2, owns international first-class production and detection equipment and realizes self-production of
products through a full set of procedures.
As for research and development, Leelen has established research and development centers in Ximen and Beijing,
and has a deep cooperation with famous institutes and enterprises such as Peking University, Xiamen University,
Huaqiao University, ABB (Xiamen), Haier, Tsinghua Tongfang, Honeywell and Johnson Controls in various aspects
such as technologies, products, etc. Leelen is a compiling and drafting member of national standards and industrial
standards and is the leader of the drafting team responsible for international building intercom standards.
Leelen is the first one to launch the national service hotline and to implement the 95105895 and the “full-course
315” service mode” in the industry. It is the first one to apply for and pass the ISO9001 quality system certification,
ISO14001 environment system certification and OHSAS18001 occupational health management system
certification. We have been confirmed by the standardization of the enterprise system evaluation (AAAA level) and
obtained the Certificate for Use of Product Marks of International Standards. We won the “Xiamen Quality Award”
in the third year. Meanwhile, Leelen is the vice-president of China Security Association and China Real Estate
Procurement Alliance, the First Choice Brand for Qualified Affordable Housing Project and China Top-500 Real
Estate Enterprises’ Procurement, the “5E” supplier of China Real Estate procurement. Besides, Leelen has been
receiving the “China Top-10 Security Brands” awards since 2004.
This Installation and Commissioning Manual was compiled in the principle “being practical, convenient,” simply
and clearly divided into several elements including Foreword, Construction Manual, Installation Manual,
Commissioning Manual, etc. Limited by experience and knowledge level, there are some inevitable shortcomings.
Project contractors and technicians using this Manual are welcome to put forward suggestions which will be used as
a reference for our subsequent revisions. Thank You!
Leelen Technical Support Center
2017.8

2
Notices for use
Correct transportation, installation, operation, service and maintenance ensure normal work of the intercom
equipment. However, you must be aware of the notices for product use before doing those works.
Attention Incorrect operations may cause danger and may result in system abnormalities or equipment damage,
which will lead to unnecessary losses.
Transport During transport, keep the product well packaged, do not unpack the product and guard the product
against water, dust, collision, etc.
Storage The packaged product should be stored in a well-ventilated room or warehouse at an ambient
temperature within a range of 10℃-40℃, with a relative humidity not greater than 80% and without corrosive
gases.
Installation Before installation, please cut off all power supplies. The installation should proceed in
accordance with the installation manual. After installation, the equipment is powered on only after it is checked
that the wiring is correct.
Maintenance The project contractor or relevant technicians should maintain, test and update the system
regularly.
Description of version
This manual is an engineering installation and commissioning manual, used as a reference by engineering
technicians for installation and commissioning. If it is found that a certain product is inconsistent with the real
object or the product manual in a certain aspect, the real object shall prevail.
This manual is customized for the company’s current product. Our company will launch new products and
revised versions will be made as soon as possible. However, if new products are not recorded in time, please
refer to the product manual or contact our company’s technicians.
All registered trademarks and product and company names in this manual belong to our company, and may
not be duplicated or used without consent or written authorization of the our company.
Some information about the products in this manual is confidential, and its copyright belongs to Leelen.
Leelen reserves the right of final interpretation on all contents of this manual.

3
1.Construction manual
1.1 System overview
1.1.1 Description of digital building intercom system
A digital building intercom system is a building intercom and access control system based on computer network
transmission.
In this system, enclosure station, a center guard unit, a central management computer, outdoor stations, digital
access control units, indoor stations, etc. are uniformly accessed to a computer network. The network computer
transmits signals to realize video intercom and access control functions, etc.
The digital building intercom system provides functions of allowing people to go in and out by sweeping access
cards, to call a home at the door to perform video intercom and ask for opening the door, and to call the
management center to perform video intercom and ask for opening the door, and allowing residents to use indoor
stations to monitor the camera of the outdoor station at the door, call the management guard unit to perform video
intercom and call other homes to perform intercom.
It also provides functions of allowing people in the management center to use the management guard unit to call
residents' indoor stations to perform video intercom, allowing people in the management center to use the computer
to perform access card management send messages to residents and send messages to enclosure stations and
building outdoor stations.
1.1.2 Main functions and features
Digital network-based data transmission makes the system more stable.
Video intercom function, door-to-door intercom function.
Support recording of incoming calls. The incoming call record includes information automatically captured by the
system.
Support visitors to leave messages.
The number of residents is not limited.
RJ45 connection for the equipment.
Support IC card-based access control and management.
The computer of the management center supports management on the access records, intercom records, etc.
Support a messaging function. The computer of the management center can send messages to the building outdoor
stations and indoor stations.
1.1.3 Topological graph and description of overall system architecture
Topological graph of overall system architecture

4
A project usually includes an enclosure access section, a management center section, a building unit access
section and an indoor section. The four sections are described in detail below.
1.1.3.1 Enclosure access section
For access control of the enclosure, an enclosure outdoor station can be installed. Visitors can call indoor stations
or the management center using the enclosure outdoor station to perform the video intercom operation. Residents
can go in and out by sweeping cards at the outdoor station.
A project can include a plurality of enclosure entrances. Some enclosure entrances are equipped with a digital
access controller instead of digital outdoor station. The digital access controller is externally connected with a card
reader and residents can go in and out by sweeping cards on the card reader.
1.1.3.2 Management center section
The management center is usually equipped with a center management computer and a management guard unit.
Management persons can use the management computer to perform management operations on access cards and use
the management guard unit to call residents at home and perform video intercom operations or answer calls from
indoor stations of residents and perform video intercom operations.
A large project can be equipped with an auxiliary management center. The auxiliary management center can also
be equipped with the center management computer and the management guard unit.

5
1.1.3.3 Building unit access section
A unit of a building is usually equipped with a building outdoor station. Visitors use the outdoor station to call
building outdoor station of residents in the unit to perform video intercom. Residents can go in and out of the unit
by sweeping cards on the outdoor station.
If a unit has several entrances, some entrances can be equipped with the digital access controller. The digital
access controller is connected with the card reader. Residents can go in and out by sweeping cards on the card
reader.
1.1.3.4 Indoor section
Indoor stations are installed at residents' homes. Residents can use the indoor station to answer calls from the
enclosure outdoor station and the building outdoor station to perform video intercom and open the door.
Residents can use the indoor station to answer calls from the management guard unit and indoor stations of other
residents, or call the management guard unit or other homes, to perform video intercom.
Residents can also use the indoor station to check call records and visitor's messages, and check notifications
from the management center.
1.2 Description of cables
1.2.1 Line configuration
Devices connected Distance L (m) Line type Remarks
1.Incoming line
From the Indoor station
to the network distributor
or network switch
L≤90 UTP5E
90≤L≤2K Multi-
mode fiber (number of
cores, self-defined)
L≤20K Single-
mode fiber (number of
cores, self-defined)
From the flat outdoor
station to network
distributor or network
switch
L≤90 UTP5E Flat outdoor station:
refers to the unit
serving as the
secondary video
doorbell.
2. Main lines in a building
From the building outdoor
station to the switch
L≤90 UTP5E
90≤L≤2K Multi-
mode fiber (number of
cores, self-defined)
L≤20K Single-mode fiber (number of
cores, self-defined)
From the building outdoor
station to the electric
control lock
L≤10 RVV2*1.0
From the building outdoor L≤10 RVV2*1.0

6
station to the magnetic
lock
From the building outdoor
station to the power supply
L≤10 RVV2*1.0 12V~24V
3.Main network cable
From guard unit to the
central core switch
L≤90
UTP5E
90≤L≤2K Multi-
mode fiber (number of
cores, self-defined)
L≤20K Single-
mode fiber (number of
cores, self-defined)
From the lower-level
network switch to central
network switch
L≤90 UTP5E
From the enclosure
outdoor station to the
network switch
90≤L≤2K Multi-
mode fiber (number of
cores, self-defined)
L≤20K Single-
mode fiber (number of
cores, self-defined)
L≤90 UTP5E
4. Indoor wiring
Power wire of the indoor
station
L≤30 RVV2*1.0
Zone wire of the indoor
station
L≤30 RVV3*0.5
Note: The building intercom device does not support direct fiber, but needs to connect via fiber optical converters.
1.2.2 Requirements for network cables
1.2.2.1 Requirements for wire diameter and wire resistance
Wire diameter: The diameter of a single UTP5E bare copper wire should be greater than 0.51m ㎡.
Wire resistance: The wire resistance of a single UTP5E wire should be less than 12Ω per 100m; the wires
resistance of a case (305m) of UTP5E wires should be controlled to be less than 36Ω.

7
1.2.2.2 Definition of line sequence of crystal heads
Note: The line sequence of the RJ45 joints follows the standard 568b, and all manufactured UTP5E wires must pass
the UTP5E wire on-off test (a cable wire tester can be used).
1.3 Requirements for pipeline construction
For installation and commissioning of the building intercom system, the pre-stage wiring is an important link of
the system installation and commissioning. Wiring builds an "information express way" in a residential community.
The intercom system of the whole residential community can run steadily and reliably only when signal
transmission is smooth. It is undoubted that high-quality wiring ensures stable and reliable system operations.
Unreasonable wiring makes the whole system unstable and causes system crash and abnormalities. Therefore, a
rational construction of the pipelines is very important.
1.3.1 Requirements for pipeline solution
Pipeline architecture: Recommended architecture is a linear architecture. Tree-type, star-type and bus-type
pipeline architectures should be used as little as possible (or not used).

8
Requirements for pipe quality: The networked lines among buildings must be independently laid with steel
pipes or racks.
Requirements for pipe diameter: The inner diameter of the pipes is usually 1.7-2 times the outer diameter of
the engineering cable; and the pipes should have as few elbows as possible, better not more than 2.
1.3.2 Requirements for pipe material solution
Performance: Selected devices such as wires, interfaces and plug-ins should have high physical and electrical
performance and high anti-interference.
Practicability: Convenient installation, high cost performance, configuration of structure and plug-in interfaces
easy to be extended.
Flexibility: Rational information interface devices, random pull and plug.
Easy management: Convenient maintenance, uniform marks, convenient wiring and wire jumping.
1.3.3 Requirements for system environment
All signal lines are wired through the weak electrical well, avoid interference sources as many as possible, and
completely follow the national standard GB-50348-2004. The signal lines cannot be configured in parallel to
strong-current wires (AC 220V), radio frequency lines, CATV cables, large-signal audio lines, etc. If parallel
wiring is inevitable, the intervals between parallel lines must be greater than 35cm.
Environmental elements such as damp-proofing and dust-proofing must be taken into consideration of
installation sites of system devices, and the installation sites must be away from acoustic, thermal, optical and
vibrating factors other than environmental factors to avoid affecting the system usage performance.
1.3.4 Network configuration environment
In order to ensure good network environment and network construction quality for the TCP/IP communication of
the company's digital intercom system devices and the communication quality among the devices, and to help
technicians, salesmen and project construction persons give instructions to clients to standardize the network
application environment, network design requirements are hereby specified:
RJ45 manufacturing standard: international standard T568B (see "Definitions of line sequence of crystal
heads" for details);
Network address configuration: ensure that the network IP addresses are not conflicting;
Communication transmission distance: maximum transmission distance of UTP5E ≤90m; if the wire length
exceeds 90m, optical fiber transmission or switch cascading are required;
Device type Device position Device requirements
Access layer Applicable to network distributor/switch which is
directly connected or accessed by an Indoor station
Digital intercom network
distributor or common switch
Aggregation
layer
Applicable to the network distributor/switch that
aggregates the access-layer switches
Has the capability of processing
data of all devices accessed to
this device
Core layer
Communication with all network devices,
positioned in the central computer room
Switch with high stability and
high performance is selected.

9
Wire selection: famous brands are recommended and the channel DC Loop resistance of all selected wires
should be less than or equal to 25Ω, which means that the closed loop resistance of any twisted pair is less than
or equal to 25Ω. For specific parameters, see electric standards in the "Code for design of comprehensive
wiring system project (GB50311-2007).”
Requirements for pipeline laying: wires and cables should be kept a necessary distance from surrounding
electric appliances such as electric motor, power transformer and radio frequency application devices that may
generate high level and strong-current cables; the wired cables cannot be electrified by AC 220V/380V
strong-current power supply, or laid in parallel with radio frequency signal lines (CATV cables, large-signal
audio lines); and if parallel wiring is inevitable, the distance between parallel wires should be greater than
30cm. For specific parameters, see "Code for design of comprehensive wiring system project
(GB50311-2007)."
Model selection of network switches of all layers
2. Installation manual
2.1 Installation attentions
Preparation before installation
Check if the installation site is firm and flat;
Ensure all wires and cables are smoothly connected and are free of damage, defects, etc.
To install the pre-embedded box or bottom case, ensure that the installation site meets requirements, the
pre-embedded box is free of deformation and its edge is not higher than the wall;
Attentions for installation process
The installation height must be controlled. The camera center of the intercom outdoor station is
recommended to be 145cm above the ground.
During installation, the environment of the installation site of the device should be taken into
consideration. The device should not be installed at the following sites:
wet site or water dropping position;
hot or cold place;
place with strong magnesium presence;
place with much dust;
corrosive place, etc.
The face recognizing device may not be installed at a position with direct exposure to sunlight.
Never beat or collide the device with a hard substance, or the device will malfunction.
Do not operate the device when it is electrified or accidents such as an electric shock or device damage
may be caused.

10
To install screws, directly screw in the screws without inclination or locking may be not tight or the
device may be damaged.
Installation completed
Clean the site and devices. Never clean the intercom devices with flammable cleaners such as alcohol or
benzene.
During cleaning, never pour liquid into the product or accidents such as electric conduction may be
caused.
2.2 Outdoor station
2.2.1 Appearances and main parameters of outdoor stations
Outdoor station Appearance Main parameters
Model No.8
series
Working Voltage: DC12-24V±10%
Max Power Consumption: ≤4W
Standby Power
Consumption: ≤2.5W
IP Grade: IP54
Capacity of Cards: ≤30,000 pcs
Panel Material: Alum Casting
Working Temp: -40℃to 70℃
Operation: Mechanical Pushbutton
Installation on Gate or Wall
Dimension(mm): 120×240×60.5
Embedded Box

11
Dim(mm):104×214×50
Color: Iron Grey
Model No.15
series
Working Voltage: DC12-24V±10%
Max Power Consumption: ≤6W
Standby Power Consumption: ≤3W
IP Grade: IP54
Capacity of Cards: ≤30,000 pcs
Panel Material:Alum Casting
Working Temp: -40℃to 70℃
Operation: Mechanical Pushbutton
Installation: Surface-mounting/emb
edded-mounting
Dimension(mm):79×148×45
Model No.10
series
Working Voltage: DC12-24V
Max Power Consumption: ≤8W
Standby Power Consumption: ≤4W
IP Grade: IP54
Capacity of Cards: ≤30,000 pcs
Panel Material: Alum +Tempered
Glass
Working Temp: -40℃to 70℃
Operation: Touch Screen
Installation: Embedded/ Iron Gate
Dimension(mm): 170×386×54
Embedded Box
Dim(mm):142×358×64
Color: Aluminum Color
Model No.16
series
Working Voltage: DC18-24V
Max Power Consumption: ≤8W
Standby Power Consumption: ≤4W
IP Grade: IP54
Capacity of Cards: ≤30,000 pcs
Panel Material: Alum +Tempered
Glass
Working Temp: -40℃to 55℃
Operation: Touch Pushbutton
Installation: Embedded/ Iron Gate
Dimension(mm):166×386×52
Embedded Box Dim(mm):
145×358×60
Color:Black + Aluminum Color

12
2.2.2 Installation of outdoor station
2.2.2.1 Model NO.8 outdoor station:
Instructions on the installation
Embed pipelines and a pre-embedded box.
Connect wires, fix the outdoor station and the sealing ring on the pre-embedded box using screws.
Place the front panel on the outdoor station.
Fasten the front panel and the outdoor station with screws. Then, the installation is completed.
2.2.2.2 Instructions on the installation of the Model No.15 outdoor station:
Surface installation on the wall
Instructions
Embed pipelines.
Fix a sunshade on an iron door using screws.
Connect wires, place the outdoor station on the sunshade in the direction of the arrow.
Fasten the outdoor station and the sunshade using screws. Then, then installation is completed.
Insertion installation

13
Instructions on the insertion installation of the 15-type entrance machine:
Embed pipelines and the pre-embedded box.
Connect wires, fix the outdoor station on the pre-embedded box with screws. The, then installation is
completed.
2.2.2.3 Instructions on the installation of the Model No.10:
Instructions of the embedded installation:
Embed pipelines and the pre-embedded box.
Connect wires, fix the outdoor station on the pre-embedded box with screws. Then, the installation is
completed.

14
2.2.2.4 Instructions on the installation of the Model No.16 outdoor station:
Instructions of the embedded:
Embed pipelines and the pre-embedded box.
Connect wires, place the outdoor station on the pre-embedded box.
Fasten the outdoor station and the pre-embedded box with screws. Then, the installation is completed.
2.2.3 Instruction on device wiring interface
2.2.3.1 Wiring interfaces of model No.8 Outdoor Station :

15
2.2.3.2 Wiring interfaces of model No.15 Outdoor Station:

16
2.2.3.3 Wiring interfaces of model No.10/16 Outdoor Stations:
Interface description:
Power interface: Power input, connected to red/black wires, supporting DC12-24V, supporting SPoE power
supply.
12V output: Connected to red/black wires, corresponding implication: 12 V + / GND, output ≤750mA.

17
RS485 interface: Connected to red/black wires, corresponding implication: A /B, externally connected to
the access card reader.
Signal locking interface: This interface uses a relay to output a switching value, and is connected to
orange/yellow/green wires with a corresponding implication of COM / NC / NO; it uses an auxiliary power
supply to supply power to the magnetic lock, the negative pole of the auxiliary power supply is connected
to the COM terminal of the interface, the NC terminal of the interface is connected to the negative pole of
the magnetic lock and the positive pole of the auxiliary power supply is connected to the positive pole of
the magnetic lock.
Network interface: Network connecting interface, 10/100m self-adaption.
Exit button: The Exit button is connected to black/blue wires, with a corresponding implication of G N D /
OPEN_DOOR.
Door state: The door state interface is connected with black/gray wires, and is externally connected to a
door magnet device.
Fire alarm interface: The fire alarm interface is connected with black/purple wires, and is externally
connected to a switching-value fire alarm signal line.
Under-voltage alarm interface: The under-voltage alarm interface is connected with brown/white wires and
is connected with a power supply under-voltage alarm signal line.
2.3 Indoor stations
2.3.1 Appearances and main parameters of indoor stations
Model No. Appearance Main parameters
V31
Working Voltage: DC12-24V±10% (SPOE
support)
Max Power Consumption: ≤5.5W
Standby Power Consumption: 1.7W
Display: 7-inch TFT LCD
Operation: Capacitive Touch/Capacitive
Pushbutton
Installation: Surface Mounting
Panel Material: PMMA
Dimension(mm): 200×140×15.9
V32
Working Voltage: DC12-24V±10% (SPOE
support)
Max Power Consumption: ≤5.5W
Standby Power Consumption: 1.7W
Display: 7-inch TFT LCD
Operation: Capacitive Touch/Capacitive
Pushbutton
Installation: Surface Mounting
Panel Material: PMMA
Dimension(mm): 220×140×15.9
This manual suits for next models