Installaon manual
Power supply for access control controllers
KDH-ZAS12/6/17
Version 3.0 ENG 19.09.2022

KDH-ZAS12/6/17 - Installation manual
2 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
Warnings
Read all of the following ps and regulaons. Failure to do so may result in damage to the device, electric shock,
re or serious injury.
It is forbidden to carry and transport the device with mounted and aached baeries. This can cause serious da-
mage up to and including loss of operaonal safety.
Installaon and connecons may only be made with the baeries removed.
When connecng the accumulator baeries, pay special aenon to the compliance of their polarity with the
descripon on the connector.
Do not obstruct the venlaon openings. There should be free space around the sides of the device for proper
venlaon. Failure to do so may result in damage to the device or shortens baery life.
Install the device in a place where it will not be exposed to direct sunlight.
The device must be powered from the power network with a protecve earthing terminal.
Before pung the device into operaon, check the quality of all connecons made.
The device may disrupt the operaon of sensive radio and television equipment located in the vicinity.
The device may only be serviced by the manufacturer's service or specialized units authorized by the manufactu-
rer.
Handling packages, used products and baeries
The product packaging is made of materials that can be recycled (wood, paper, cardboard, plascs).
Unnecessary packaging should be segregated and handed over to a waste recipient.
This marking placed on the product indicates that the product should not be disposed of with house-
hold waste aer its working life, but should be handed over to a collecon point for used electronic
equipment. Used baeries are hazardous waste and must be disposed of. This will help to avoid
harmful eects on human health and the environment
Table of content
1.1 Power supply descripon.........................................................................................................3
1.2 Technical specicaon ............................................................................................................4
1.3 Dimensions...............................................................................................................................5
1.4 Layout of basic elements of power supply module ZBM-12V6A .............................................6
1.5 Descripon of ZBM-12V6A power supply module signalling operaon..................................6
1.6 List of operaon states.............................................................................................................7
1.7 Installaon, connecon and starng ........................................................................................7

KDH-ZAS12/6/17 - Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 3
1.1 Power supply descripon
The power supply is intended for an uninterrupted supply of devices adapted to be supplied with voltage of
12V. The backup power source is a 12V VRLA lead-acid baery. The PSU is made in the form of a wall-mounted
cabinet, in which the ZBM-12V6A PSU module is mounted, and there is space for a 12V 17 or 18Ah baery. This
module takes care of the enre operaon of the baery bank, protecon of outputs, signaling, etc.
Two, permanently installed cables terminated with 6.3mm connectors are used to connect the baery bank.
The connecon to the 18Ah baery, which is equipped with screw terminals, is made through a transion element
- a male 6.3mm connector with a Ø6mm hole.
The current outputs of the PSU and its relay signaling outputs are connected by connectors equipped with screw
terminals. The connecon can be made both when the connector caps are already mounted in the power supply
and aer their removal.
View of the power supplies and a list of parameters
Inside view of the power supply KDH-ZAS12/6/17 Power supply module ZBM-12V6A
Package contest
1. Spacers for the rear wall - 4 szt.
2. Connectors for the control module- 4
szt.
3. Metal brackets for controller and
IN/OUT module- 6 szt.
4. Screws for brackets - 12 szt.
5. Door tamper - 1 szt.
6. Cable gasket 230VAC - 1szt.
7. Baery connectors 17/18Ah - 2szt.
8. Plasc connector cover 230VAC-1szt.

KDH-ZAS12/6/17 - Installation manual
4 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
1.2 Technical specicaon
Electrical parameters
Power
Power voltage 110…240 V AC 50Hz
Power current 1.52 A
Power factor 0.58
Leakage current in the protecve conductor ≤ 0.75 mA /240 V AC
Energy eciency at nominal condion 89%
Inrush current (cold start) 5 A /240 V AC
Output
Output NO. 2
Outputs protecons:
- OUT 1
- OUT 2
polymer fuse
4 A
1.1 A
Output voltage 13.5…13.6…13.7 V
Maximum output current
Total, from both outputs at 25 ° C ambient temperature 5 A
Connecon of outputs Two connectors with screw terminals, ARK 130-2 type
Baery management
Output protecon fuse 5x20mm 8.0AF
Baery capacity 18 Ah
Baery charging current limitaon ~1 A
Floang operaon voltage 13.5…13.6…13.7 V
Low baery voltage indicaon 11.2…11.4…11.6 V
Automac disconnecon of the discharged baery 10.5…10.8…11.0 V
Power consumpon from the baery for own needs
- Baery connected
< 65 mA
Baery connecon method:
- permanently connected cables
1.5mm2 /250mm ended connectors 6.3mm
2 szt.
Relay signaling outputs
Characteriscs of outputs
- NO. Relays Max. Capacity of relay contacts
- type of available contacts
- acve signaling state
2 relays, 30 V DC/1 A
3 contacts pair (NO i NC)
relay not energized
Connecon method 2 connectors with screw terminals, ARK 130-3 type
Mechanical parameters
Dimensions 394 × 354 × 86 mm
Condions of use
Ambient temperature during operaon -25…+55°C
Storage temperature limit -30…+85°C
Relave humidity (non-condensing) 30…80%
Compliance with standards
Electromagnec Compability PN-EN 50130-4 PN-EN 61000-6-3
Bezpieczeństwo elektryczneElectrical safety Class 1 EN 60950-1

KDH-ZAS12/6/17 - Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 5
1.3 Dimensions
The power supply is prepared for wall mounng. The gures below show the closed power supply with its di-
mensions and the spacing of the mounng holes.

KDH-ZAS12/6/17 - Installation manual
6 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
1.4 Layout of basic elements of power supply module ZBM-12V6A
1.5 Descripon of ZBM-12V6A power supply module signalling operaon
The power supply is equipped with two relay outputs and four LED diodes placed directly on its printed circuit bo-
ard. It is possible also to connect an external LED signaling. which repeats the signaling on the printed circuit board.
Nr Descripon Symbol
1. 230V power connector terminals L, N, PE
2. Output 1 terminals OUT 1
3. LED indicang voltage presence at the OUT1
4. Output 2 terminals OUT 2
5. LED indicang voltage presence at the OUT2
6. Low baery voltage signaling relay output LOW BAT
7. Mains power loss signaling relay output MAIN FLT
8. Baery fuse
9. Oponal connector for external LED signaling LED
10. Low baery voltage indicaon LED (yellow) LOW BAT
11. Mains power loss LED (green) MAIN FLT
12. Cables for connecng the baery bank BAT

KDH-ZAS12/6/17 - Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 7
1.6 List of operaon states
1.7 Installaon, connecons and starng.
The power supplies are intended for installaon as part of an installaon by qualied personnel. The baery should not
be present in the power supply during installaon. Removal of the power supply module itself is not required. The PSU casing is
prepared for running the power supply and load cables through the rear casing. The dedicated holes are shown in the drawing
in pt. 1.2.
Before assembly, on the selected surface (e.g. wall with wall plugs), prepare 4 holes with a spacing of 350 × 275mm. In the
two upper holes, appropriate screws should be screwed in (maximum head diameter 8mm), on which the power supply cabi-
net should be hung. Inserng the two boom screws locks the cabinet. All screws can be ghtened in this state.
The power supply must be connected to a xed installaon using a protecve conductor and taking into account the L, N
and PE markings. It is recommended to equip the installaon with an overvoltage protecon system. It is required to install in
the supply circuits, apart from the power supply, an installaon switch with a nominal current of at least 3A. This switch is only
used to protect the mains supply cables against short-circuit and can be used for service and tesng purposes - checking that
the output voltage is maintained in the event of a mains power failure.
The power supply's transformer is equipped with its own fuse in the mains supply circuit. This fuse cannot be replaced, be-
cause its blown is a sign of serious damage.
The power supply is designed to work with a 12V baery, the so-called maintenance-free, which should be placed in the
cabinet aer mechanical and electrical assembly is completed. Pay parcular aenon to the polarity of the connecon betwe-
en the PSU module and the baery pack. If the connecon is incorrect, the baery circuit fuse will be damaged.
Aer making all the necessary connecons (mains power supply, baery pack and possible loads - their connecon is not
necessary to check the operaon of the power supply), the ability to maintain the output voltage can be checked. To do this,
turn o the mains supply with a switch located in the mains supply line, apart from the power supply itself, and check the pre-
sence of voltage at the outputs of the power supply, which is indicated by LED diodes located on its printed circuit board. You
can also use an ohmmeter to check the posion of the MAIN FLT relay. The status of signaling is presented in the table below.
*) The relay is ON when it has moved in relaon to the drawing describing this output
(the drawing shows the system of contacts in the OFF state of the relay).
Symbol State Descripon
Relay outputs
MAINS FLT OFF
ON
- no mains power or the power supply is damaged
- Power is ON, power supply is OK
LOW BAT OFF
ON
- Low baery voltage
- Baery voltage is OK
LED indicators
OUT 1 (G) OFF
ON
- No voltage on OUT1
- Voltage on OUT1 is OK
OUT 2 (G) OFF
ON
- No voltage on OUT2
- Voltage on OUT2 is OK
LOW BAT (Y) OFF
ON
- Low baery voltage
- Baery voltage is OK
230Vac (G) OFF
ON
- no mains power or the power supply is damaged
- Power is ON, power supply is OK
Power ON Power OFF
LED MAIN FLT ON OFF
LED OUT 1 ON ON
LED OUT 2 ON ON
Relay MAIN FLT ON * OFF

KDH-ZAS12/6/17 - Installation manual
8 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
85 688 32 33 85 688 32 34
85 688 32 33 85 688 32 34
NIP: 9512500868, REGON: 385953687
Wpisana do rejestru przedsiębiorców prowadzonego przez Sąd Rejonowy dla m.st. Warszawy w Warszawie,
XIII Wydział Gospodarczy Krajowego Rejestru Sądowego pod numerem KRS 0000838329,
kapitał zakładowy wpłacony w całości w wysokości: 5 000 zł
NIP: 9512500868, REGON: 385953687
Wpisana do rejestru przedsiębiorców prowadzonego przez Sąd Rejonowy dla m.st. Warszawy w Warszawie,
XIII Wydział Gospodarczy Krajowego Rejestru Sądowego pod numerem KRS 0000838329,
kapitał zakładowy wpłacony w całości w wysokości: 5 000 zł
Table of contents
Other AAT Power Supply manuals