manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ABB
  6. •
  7. I/O System
  8. •
  9. ABB VSN300s User manual

ABB VSN300s User manual

This manual suits for next models

1

Other ABB I/O System manuals

ABB Symphony Harmony Series User manual

ABB

ABB Symphony Harmony Series User manual

ABB S800 I/O User manual

ABB

ABB S800 I/O User manual

ABB S800 I/O User manual

ABB

ABB S800 I/O User manual

ABB Symphony Harmony Series User manual

ABB

ABB Symphony Harmony Series User manual

ABB NEXUS-3 Series User manual

ABB

ABB NEXUS-3 Series User manual

ABB SAM600 Series User manual

ABB

ABB SAM600 Series User manual

ABB AE/S 4.2 User manual

ABB

ABB AE/S 4.2 User manual

ABB CL-LSR Series User manual

ABB

ABB CL-LSR Series User manual

ABB FIO-01 User manual

ABB

ABB FIO-01 User manual

ABB SAM600 Series Installation and operation manual

ABB

ABB SAM600 Series Installation and operation manual

ABB RIO600 Instruction sheet

ABB

ABB RIO600 Instruction sheet

ABB Symphony Harmony Series User manual

ABB

ABB Symphony Harmony Series User manual

ABB AC500 Series User manual

ABB

ABB AC500 Series User manual

ABB S800 User manual

ABB

ABB S800 User manual

ABB Remote I/O RIO600 Guide

ABB

ABB Remote I/O RIO600 Guide

ABB Symphony Harmony Series User manual

ABB

ABB Symphony Harmony Series User manual

ABB S900 User manual

ABB

ABB S900 User manual

ABB Symphony Harmony Series User manual

ABB

ABB Symphony Harmony Series User manual

ABB OPT-MF-001 User manual

ABB

ABB OPT-MF-001 User manual

ABB RIO600 User manual

ABB

ABB RIO600 User manual

ABB RAIO-01 User manual

ABB

ABB RAIO-01 User manual

ABB FIO-01 User manual

ABB

ABB FIO-01 User manual

ABB DC561 User manual

ABB

ABB DC561 User manual

ABB FDIO-01 User manual

ABB

ABB FDIO-01 User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

M-system R7D-YV2A instruction manual

M-system

M-system R7D-YV2A instruction manual

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Release 0.5 – April 2018
© Copyright 2018 ABB. Tutti i diritti riservati. © Copyright 2018 ABB. All rights reserved.
Specifiche soggette a modifica senza preavviso. Specifications are subject to change without notice.
Le immagini di prodotto sono solo a scopo dimostrativo. The product images are for demonstration purposes only.
VSN300s – General Connectivity Module
VSN 300s – General Connectivity Module is a
factory optionally assembled communication
board proper to be used for instance on PVS
inverter series but not limited to this product
family.
This communication board provides the fol-
lowing features:
- Wireless bidirectional communication 802.11
b/g/n compliant;
- Dual mode, access point + station;
- Data logging capabilities;
- 4GByte Flash disk storage;
- Integrated web server
- Dual LAN ports for Ethernet connectivity
- USB ports for expanded connectivity
- ADC/PWM/LCD support
It is a pluggable board directly connected to
PVS logic board through a dedicated con-
nector.
Its installation on inverter is typically done by
the factory, but when installed as a spare part
in a repairing process, the installation has to
be executed by trained personnel only.
The board is powered by the inverter.
Proper connector for antenna is available on
board.
The board uses a Murata LBEP5CLXRC-701,
an 802.11b/g/n WLAN module built around
the Texas Instruments WL1801 chipset.
.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including in-
terference that may cause undesired opera-
tion.
The manufacturer is not responsible for any
radio or TV interference caused by unauthor-
ized modifications to this equipment. Such
modifications could void the user’s authority to
operate the equipment.
This equipment has been tested and found to
comply with the limits for a Class B digital de-
vice, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reason-
able protection against harmful interference in
a residential installation. This equipment gen-
erates, uses and can radiate radio frequency
energy and, if not installed and used in ac-
cordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interfer-
ence will not occur in a particular installation.
If this equipment does cause harmful interfer-
ence to radio or television reception, which
can be determined by turning the equipment
off and on, the user is encouraged to try to
correct the interference by one or more of the
following measures:
(continue on the next page)
MODEL: VSN300s
FCC ID: X6W-VSN300S
Release 0.5 – April 2018
© Copyright 2018 ABB. Tutti i diritti riservati. © Copyright 2018 ABB. All rights reserved.
Specifiche soggette a modifica senza preavviso. Specifications are subject to change without notice.
Le immagini di prodotto sono solo a scopo dimostrativo. The product images are for demonstration purposes only.
VSN300s – General Connectivity Module
Techical data are in following table.
Any changes or modifications not expressly
approved by the party responsible for compli-
ance could void the user’s authority to operate
the equipment.
Installer should take care that Regulatory La-
bel applied on the Host Equipment includes
the following: Contains FCC ID: X6W-
VSN300S.
This device shall be used such that a mini-
mum separation distance of 20cm/7,87” is
maintained between the radiator (antenna)
and user's/nearby people's body.
Page 2 of 3
(continue from the previous page)
- Reorient or relocate the receiving antenna.
- Increase the separation between the
equipment and receiver.
- Connect the equipment into an outlet on a
circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced
radio/TV technician for help.
Release 0.5 – April 2018
© Copyright 2018 ABB. Tutti i diritti riservati. © Copyright 2018 ABB. All rights reserved.
Specifiche soggette a modifica senza preavviso. Specifications are subject to change without notice.
Le immagini di prodotto sono solo a scopo dimostrativo. The product images are for demonstration purposes only.
VSN300s – General Connectivity Module
Page 3 of 3
Item Value Note
Product name VSN300s General Connectivity Module
Connections
Connection to PVS Logic board 314-pin edge-finger on PCB Power + Inverter Hyperlink + Inter-
faces
Connection on PVS Logic board Standard MXM 3.0 connector
Input / Output
RF 802.11 b/g/n UFL connector
COMM 3 x UART, 2 x CAN
USB 4 x USB 2.0 + USB OTG
ETHERNET 2 x LAN ports 100Mbit/s
ADC 8 x 12-bit channels
LCD support 1 x 24-bit TTL for passive LCD
Other 1 x SPI, 1 x I2C, 1 x I2S, 1 x PWM
Supply
Power supply From the inverter logic board,
12VDC, 24VDC typ.
Phisical
Environmental Protection Class Bare pcb to be assembled into PVS
inverters
Dimensions mm (HxDxW) 90mmx40mmx5mm (SMD top and
bottom)
Installation Inverter shall be completely powered
off for at least 5 minutes to let any
voltage reduced to a safe level; plug
in the board; secure the board to the
provided stand offs by screws.
Installation and operation shall be
executed by trained personnel only.
Please read this instructions before
operate installation or dismantling.
Antenna
RF Antenna Technology Corp.,
Type EA-79F (Item Number
ZFA.00008)
2.4 GHz with Swivel RP-SMA, 105
mm long by 10.0 mm diameter (bot-
tom side), 3.32 dBi (peak) gain @
2500 MHz.
Antenna is assembled on the Host
Equipment, and secured to the U.FL
Coaxial Connector (J2) soldered on
the VSN300s.
Certifications
Marking FCC ID X6W-VSN300S
Safety and EMC Standard FCC part 15
VSN300s
12VDC, 24VDC typ.
PWM4 ENABLE
V
OUT
Inverter Hyperlink
RF Out
USB 2.0
ADC ETHERNET
LCD