NSF61/ANSI372 Certified Lead-Free
Water Meters with Totalizer Only
GLF-062 to GLF-200
General Information
G F water meters use the internationally-accepted
multi-jet principle. A gear train drives the register
totalizer dials.
Accuracy Curve
Inlet Strainer
Clean the strainer yearly, or as required, depending on
water condition. Pull out the strainer or back-flush the
meter to loosen trapped particulates.
Cali ration
New meters are factory-tested to meet the AWWA
C-708 Multi-Jet Meter accuracy specification.
Suggested Meter Installation
• Thoroughly flush the service line upstream of the
meter to remove dirt and debris.
• Set the meter inline. Water meters are recommended to
be installed horizontally with the register facing upwards.
• Make sure the water flow follows the arrow cast on
the meter body.
• Slowly open any upstream valves to prevent damage
to the meter.
NSF61/ANSI372 Certified Lead-Free
Water Meters with Totalizer Only
GLF-062 to GLF-200
Internal Parts Replacement
All the internal parts of the meter lift out as a unit, after the
top has been unscrewed. The lens can then be removed
and internal assembly lifted out. If necessary, turn the meter
upside down and tap one end lightly on a countertop to
loosen internals. The assembly can be separated by hand.
www.accent-control.com •2101 Potshop Lane •Norristown, PA 19403 •888-265-5632 www.accent-control.com •2101 Potshop Lane •Norristown, PA 19403 •888-265-5632
1.5%
1/2”, 3/4” meters only
1”, 1 1/2” and 2” meters
Main Technical Data
US gpm
Minimum reading US gallon
US gpm
US gpm
US gpm
062 - 5/8”x1/2” 075 - 5/8”x3/4” 100 - 3/4”x1”100F - 1” 150 - 1 1/2” 200 - 2”
20 20 30 50 100 160
10 10 15 25 50 80
1 1 2 3 5 8
0.25 0.25 0.5 0.75 1.5 2
0.005 0.005 0.05 0.05 0.05 0.05
Specifications
Specifications
Cert f cat on Meters comply with NSF/ANSI61
AnnexG, NSF/ANSI372, and conforms
with lead content requirements for
“lead-free”plumbing as defined by the
U.S. Safe Drinking Water Act effective
Jan. 1, 2014
Temperature 105˚ F (40˚ C) max
Pressure 150 psi operating max
Mater als Body/cplgs EcoBrass*
Internals Engineered thermoplastic
Magnet Alnico
Accuracy +/-1.5% of reading within Qt-Qmax
Sensor Reed switch
Max mum Current 20 mA
Max mum Voltage 24 Vdc or Vac
Cable Length 12’ (4m) std (2000’ max run)
*EcoB ass B onze Alloy-Lead composition is less than 0.1% by weight
3%
Flow (GPH)
Parts 5/8”x1/2” 5/8”x3/4” 3/4”x1” 1” 1 1/2” 2”
1.1 id/Hinge Assembly-Totalizer A0724 A0724 A0725 A0725 A0726 A0727
2.1 Retaining Ring-Totalizer A0728 A0728 A0729 A0729 A0730 A0731
3ens Gasket A0604 A0604 A0605 A0605 A0606 A0606
4.1 ens-Totalizer A0003 A0003 A0003 A0003 A0003 A0003
5O-Ring A0644 A0644 A0645 A0645 A0646 A0646
7A Internal Assembly-Gallons A0618 A0619 A0620 A0621 A0622 A0623
7B Internal Assembly-Cubic ft. A0718 A0719 A0720 A0721 A0722 A0723
8 Tubular Strainer A0016 A0016 A0018 A0018 A0020 A0022
9Internal Strainer A0015 A0015 A0017 A0017 A0019 A0021
10 Coupling Gasket, 2/meter A0226 A0228 A0230 A0230 A0232 A0234
11 ,