Accles & Shelvoke CASH Stun Check Operational manual

CASH Stun Check
Product Data Sheet
www.acclesandshelvoke.co.uk
Key Features
Equipment set up
Safe Operating Instructions
Maintenance
Trouble Shooting and Servicing
Parts List
3
3
3
3
3
3
DO NOT ATTEMPT TO USE THIS STUNNING TOOL UNTIL YOU
HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS
Manufactured by Accles & Shelvoke Ltd
Selco Way, Off First Avenue, Minworth Industrial Estate, Sutton Coldeld, West Midlands, B76 1BA ENGLAND
Tel: +44 (0) 121 313 4567 Fax: +44 (0) 121 313 4569 Web: www.acclesandshelvoke.co.uk

1
Key Features / Safe Operating Instructions
CASH Stun Check
To maximize the effectiveness of our CASH captive bolt stunners in the eld, Acccles & Shelvoke have
developed the CASH Stun Check which has been designed to indicate stunner performance by means
of indicator lights for Fast, OK and Slow. By checking that the bolt velocity conforms to the required
specication, users can guarantee a more effective performance and greater yield.
Available for CASH Special, CASH Cowpuncher, CASH Bulldozer, CASH Magnum .22 and .25 Stunners.
1EQUIPMENT
SET UP
Plug the lead from the selector console into the socket in the xture
Plug 9V adaptor into rear of console
and switch on
SELECTION CONSOLE
The console is used to select powerload colour
by means of a rotary switch. Three indicator
lights give a visual display of the performance of
the stunner under test - Fast / Ok / Slow.
The set indicator illuminates when the reset
button has been pressed to show that the
equipment is ready to use.
NB: For the Cowpuncher / Bulldozer Units
there is no powerload selector because
special test powerload will be supplied. SECURE SENSOR FIXTURE
TO WOODEN BENCH - 38MM
THICK MIN. WITH:-M10 BOLTS.
SENSOR FIXTURE
The xture holds the Stunner under test in ana upright position ready for ring. The unit carries two sensors which detect
the bolt as it passes them, enabling the bolt velocity to be measured.
NB: Sensor xture is supplied with the appropriate adaptors for type of stunner used. Sensor xture ‘B’ type to
be used for:- Cowpuncher / Bulldozer and T.C Universal.
2INSTRUCTIONS
FOR USE
IMPORTANT: STUNNER SHOULD BE
TESTED AT OPERATING TEMPERATURE
(1) Select the appropraite powerload colour on the
console. (Set ‘T’ if test powerload is to be used).
(2) Press the RESET button.
(3) Locate the stunner, bolt end rst into the large
bore in top end of xture and hold down on the
rubber pad.
(4) Hold stunner securely at ARMS LENGTH and
then re when comfortable.
DO NOT ATTEMPT TO PUT A LOADED
STUNNER INTO SENSOR FIXTURE. ALWAYS
PUT UNLOADED STUNNER INTO FIXTURE.
ONLY THEN! LOAD THE STUNNER AND COCK
FIRING MECHANISM WHEN READY TO USE
WEAR SAFETY GLASSES AND EAR
PROTECTION. DO NOT LEAN OVER THE
STUNNER WHEN FIRING
5) Note which LED has illuminated on the console.
i.e:- FAST / OK / SLOW.
(6) Press the RESET button and repeat steps (3-5). A minimum of
ve shots should be red.
LED’S (Step 5)
Set indicator
(Step 2)
Reset button
(Step 2&6)
Stunner
(Step 3)
Selector
(Step 1)

2
Stunner
(Step 3)
Selector
(Step 1)
3FIRING
THE STUNNER
WEAR SAFETY GLASSES AND EAR PROTECTION. HOLD THE
STUNNER AT ARMS LENGTH AND FIRE WHEN COMFORTABLE.
DO NOT LEAN OVER THE STUNNER WHEN FIRING
REFER TO STUNNER INSTRUCTIONS BEFORE USE.
REFER SPECIFICALLY TO SAFETY WARNINGS
4THE TEST
4To obtain an accurate indication of stunner performance, a minimum of ve
shots should be red.
4Only Accles & Shelvoke Approved powerload should be used otherwise the
test is invalidated.
4If more shots indicate OK (Green LED) than slow (RED LED) then the
stunner is OK. If more shots indicate slow (RED R.H LED) out of the total
number red, then the stunner requires examination and will need cleaning
and servicing.
4Always check that the correct settings have been chosen.
4Always check that Accles & Shelvoke approved powerload are being used.
4Always ensure that the equipment is kept clean.
(REFER TO MAINTENANCE INSTRUCTIONS)
NB:- IF A FAST READING IS OBTAINED CHECK:
(1) Powerload selection is correct
(2) If (1) above is OK fast reading may be due to marginally fast powerload.
5MAINTENANCE
4The selection console lead and plug should be examined for cuts and wear.
4The 9V mains adaptor lead should be examined for cuts and wear.
4The sensor xture small centre bore must be cleaned with the copper wire brush provided.
4All checks should be made before and after use. If in doubt consult your distributor.
6TROUBLE SHOOTING
IF SLOW :- POSSIBLE CAUSE
Sensor unit incorrectly connected
Sensor unit dirty
Incorrect powerload selection
Incorrect powerload used
Powerload not Accles & Shelvoke approved
Bolt not returned fully
Breech piston bore and/or bolt piston is worn beyond use
Stunner is dirty
Test unit is faulty
IF FAST:- POSSIBLE CAUSE
Incorrect powerload selection on console
Incorrect powerload used
Powerload not Accles & Shelvoke approved
Marginally fast powerload
ACTION
Refer to equipment set up section
Refer to maintenance section
Refer to instructions for use
Refer to instructions for use
Use Accles & Shelvoke approved powerloads only
Check bolt is not bent. If it is replace the bolt. Check the
sleeves, replace if necessary. Check gun is clean
If breech is new replace bolt. If bolt is new replace breech
Clean stunner
Return to distributor
ACTION
Refer to instructions for use
Refer to instructions for use
Use Accles & Shelvoke approved powerloads only
No action necessary
IF IN DOUBT CONTACT YOUR DISTRIBUTOR
THE TEST POSITION:- T
This position is the manufacturers test position, for testing with manufacturers test powerload only.
Do not use this position unless using test powerloads available only from Accles & Shelvokle Ltd.
NB:- STUNCHECK UNITS FOR COWPUNCHER / BULLDOZER WILL HAVE TEST POSITION ‘T’ ONLY
THEREFORE TEST POWERLOADS ONLY MUST BE USED WITH THESE UNITS.

3
Parts List
CASH Stun Check
# Part not illustrated
When ordering please quote part number and type of stunner to be checked as some parts are not
interchangeable.
Stun Check is available for CASH Special, CASH Cowpuncher, CASH Bulldozer, CASH Magnum .22
and .25 Stunners.
ITEM PART DESCRIPTION
NO. NO.
1 CSC010 Control unit
2 CSC020 Sensor xture
3 CSC021 Sensor xture B (For CASH Cowpuncher / CASH Bulldozer)
4 CSC025 Sensor sub assembly
5 CSC030 Rubber washer
6 CSC031 Adaptor CASH Magnum .22
7# CSC032 Adaptor Complete CASH Magnum .25
8# CSC042 Adaptor Complete CASH Cowpuncher / CASH Bulldozer
9# CSC043 Adaptor Sleeve - CASH Cowpuncher / CASH Bulldozer
10# CSC044 Adaptor Sleeve - CASH Magnum .25
11 CSC080 Fixture ‘O’ Ring – CASH Special
12 CSC082 Fixture ‘O’ Ring - CASH Magnum .22
14# CSC085 Adaptor ‘O’ ring - CASH Cowpuncher / CASH Bulldozer
15# CSC086 Adaptor ‘O’ ring - CASH Magnum .25
16# 3085 Feet 2/Set
17# 6942 Cleaning brush
13 CSC084 Fixture ‘O’ Ring - CASH Magnum .25 / CASH Cowpuncher / CASH Bulldozer
ORDER CODES FOR STUN CHECK UNITS
CSC001 CASH Special .22
CSC002 CASH Special Heavy Duty
CSC003 CASH Magnum .22
CSC004 CASH Magnum .25
CSC005 CASH Cowpuncher .22
CSC006 CASH Bulldozer .25
CSC007 CASH Special .25
CSC011 CASH Magnum .25 Euro Stunner
511 12 13
4
14 2
3
CSC020 – Complete unitt
CSC021 – Complete unit ‘B’ type
Table of contents
Popular Test Equipment manuals by other brands

Tektronix
Tektronix 519 operating instructions

Bell System
Bell System KS-8455 DESCRIPTION AND USE

Agilent Technologies
Agilent Technologies InfiniiVision 5000 Series Service guide

HP Autozubehor
HP Autozubehor OBD II owner's manual

Fluke
Fluke P5500 Series user manual

bonitron
bonitron M3628UCT Customer Reference Manual

Vitalograph
Vitalograph BreathCO Quick Start User Training Manual

Sperry instruments
Sperry instruments PSl8031 operating instructions

Extech Instruments
Extech Instruments ET23B user manual

EXFO
EXFO MaxTester 635 Quick reference guide

Tektronix
Tektronix MDO4000C Series user manual

Owon
Owon VDS6104P user manual