AccuTemp RB36 User manual

CHEF BASE
PRODUCT MANUAL
1
SP8143-2008

Installation and General Information:
DO NOT WALK OR STAND ON TOP OF DRAWERS FOR ANY REASON or damage to the case and
serious personal injury could occur. THEY ARE NOT STRUCTURALLY DESIGNED TO SUPPORT
EXCESSIVE EXTERNAL LOADING such as the weight of a person.
Handling of Griddle stand
●This self-contained case is manufactured with heavy duty casters mounted
permanently to the base for ease of mobility when unloading and moving
around for placement in the proper location.
●If a PALLET JACK IS USED TO MOVE THE CASE, USE A SPOTTER TO GUIDE
FORKS in place to prevent damage to electrical, plumbing, and refrigeration
lines.
2
SP8143-2008

TABLE OF CONTENTS
Safety Notice
2
Product Specification Sheet 4
Technical Date RB36 5
Technical Date FB36 6
Technical Date RB48 7
Technical Date FB48 8
Pan Layouts Options 9
General Preventive Maintenance
10
Periodic Cleaning Procedure 11
Troubleshooting Chart 12
Troubleshooting Chart Cont. 13
Warranty 14
3
SP8143-2008

PRODUCT SPECIFICATION SHEET
CORD & PLUG AT REAR
THERMOSTAT
RMV FRONT PANEL
FRONT BRAKES
RMV SIDE PANEL
AIR FLOW
4
SP8143-2008

Technical Data
M
o
d
e
l
N
o
. ( REFRIGERATION )
RB36
L
e
n
g
t
h
35
.
625
"
H
e
i
g
h
t
w
i
t
h
c
a
st
e
r
s
27.25"
D
e
p
t
h
33
.7
5
"
O
p
e
r
a
t
i
n
g
t
e
m
p
e
r
a
t
u
r
e
37
°
F
t
o
40
°
F
R
e
f
r
i
ge
r
an
t
(
e
x
p
an
s
i
o
n
va
l
v
e
)
R
404A
C
o
m
p
r
e
ss
o
r
size
H
P
1
/
4
D
e
f
r
o
st
p
e
r
d
ay
(
24
h
o
u
r
s
)
Auto
V
o
l
t
a
ge
115
A
m
p
e
r
a
ge
5.6
C
o
r
d
an
d
p
l
u
g
-
C
o
n
d
e
n
s
i
n
g
U
n
i
t
L5-15
P
N
u
m
b
e
r
o
f
drawers
2
5
SP8143-2008

Technical Data
M
o
d
e
l
N
o
. ( FREEZER )
FB36
L
e
n
g
t
h
35
.
625
"
H
e
i
g
h
t
w
i
t
h
c
a
st
e
r
s
27.25"
D
e
p
t
h
33
.7
5
"
O
p
e
r
a
t
i
n
g
t
e
m
p
e
r
a
t
u
r
e
0
°
F
t
o
3
°
F
R
e
f
r
i
ge
r
an
t
(
e
x
p
an
s
i
o
n
va
l
v
e
)
R
404A
C
o
m
p
r
e
ss
o
r
size
H
P
1
/
4
D
e
f
r
o
st
p
e
r
d
ay
(
24
h
o
u
r
s
)
4
V
o
l
t
a
ge
115
A
m
p
e
r
a
ge
6.4
C
o
r
d
an
d
p
l
u
g
-
C
o
n
d
e
n
s
i
n
g
U
n
i
t
L5-15
P
N
u
m
b
e
r
o
f
drawers
2
6
SP8143-2008

Technical Data
M
o
d
e
l
N
o
. ( REFRIGERATION )
RB48
L
e
n
g
t
h
47
.
625
"
H
e
i
g
h
t
w
i
t
h
c
a
st
e
r
s
27.25"
D
e
p
t
h
33
.7
5
"
O
p
e
r
a
t
i
n
g
t
e
m
p
e
r
a
t
u
r
e
37
°
F
t
o
40
°
F
R
e
f
r
i
ge
r
an
t
(
e
x
p
an
s
i
o
n
va
l
v
e
)
R
404A
C
o
m
p
r
e
ss
o
r
size
H
P
1
/
4
D
e
f
r
o
st
p
e
r
d
ay
(
24
h
o
u
r
s
)
A
V
o
l
t
a
ge
115
A
m
p
e
r
a
ge
5.6
C
o
r
d
an
d
p
l
u
g
-
C
o
n
d
e
n
s
i
n
g
U
n
i
t
L5-15
P
N
u
m
b
e
r
o
f
drawers
2
7
SP8143-2008

Technical Data
M
o
d
e
l
N
o
. ( FREEZER )
FB48
L
e
n
g
t
h
47
.
625
"
H
e
i
g
h
t
w
i
t
h
c
a
st
e
r
s
27.25"
D
e
p
t
h
33
.7
5
"
O
p
e
r
a
t
i
n
g
t
e
m
p
e
r
a
t
u
r
e
0
°
F
t
o
3
°
F
R
e
f
r
i
ge
r
an
t
(
e
x
p
an
s
i
o
n
va
l
v
e
)
R
404A
C
o
m
p
r
e
ss
o
r
size
H
P
1
/
4
D
e
f
r
o
st
p
e
r
d
ay
(
24
h
o
u
r
s
)
4
V
o
l
t
a
ge
115
A
m
p
e
r
a
ge
6.4
C
o
r
d
an
d
p
l
u
g
-
C
o
n
d
e
n
s
i
n
g
U
n
i
t
L5-15
P
N
u
m
b
e
r
o
f
drawers
2
8
SP8143-2008

PAN LAYOUTS (FULL SIZE PANS OPTIONS)
9
Please note - each drawer is only supplied with one pan rail as standard. More
pan rails can be purchased separately to create all layouts seen above.
SP8143-2008

General Preventive Maintenance
Performance of the air cooled condenser coil
located inside of the condensing unit
compartment of your new unit depends primarily
on the amount of air passing through the
condenser fins.
1. Your case will run more efficiently, consume less
energy, and provide maximum trouble free service
throughout its lifetime if the condenser is kept clean
and an adequate supply of clean air is provided at all
times. Once a month, inspect the condenser coil and
check for blockage.
To access the condenser coil remove front panel.
If the condenser coil is dirty or blocked, disconnect the
power supply to your unit and remove the dirt from the
condenser fins. Using a vacuum cleaner with a brush
attachment may help in the cleaning process. After
cleaning, restore electrical service to your unit.
2. Each unit has a drain tube located inside the condenser
compartment that removes the condensation from the
evaporator coil housing and routes it to an external
condensate pan. The drain tube can become loose or
disconnected during normal use. If you notice water
is collecting underneath the unit, be sure the drain tube
is connected to the evaporator drain pan and is
discharging water into the condenser drain pan.
10
SP8143-2008

Periodic Cleaning Procedure
It is best to clean your unit when the product load
is at its lowest level. To clean the interior or
exterior cabinet surfaces, the following procedure
is recommended:
1. Disconnect your unit from its power supply and
remove all food products from inside the
drawers.
2. Allow the cabinet to reach room temperature.
Remove drawers. Use a sponge to wash the
interior, exterior, and accessories with a baking
soda and warm water solution. Rinse
thoroughly with clear water and dry with a soft
clean cloth.
3. Return all accessories to their respective
positions and reconnect electric power supply
to the unit.
4. Energize unit and allow appropriate amount of
time to reach normal operating temperature
before returning food product to display case.
Important Note: Failure to dry all surfaces
completely may cause water stains or
streaking on stainless steel finish.
11
SP8143-2008

Precautions
1. Never use harsh detergents, cleaners, scouring
powders, or chemicals when cleaning your
unit.
2. Strong bleaches tend to corrode many
materials and should never come in contact
with stainless steel.
3. Tincture of iodine, or iron should not come in
contact with stainless steel. These solutions,
which cause stainless steel to discolor, should
be rinsed off immediately if contact occurs.
4. Gritty, hard abrasives will mar the finish of
stainless steel and are not recommended.
12
SP8143-2008

Troubleshooting Chart
13
SP8143-2008

Troubleshooting Chart Cont.
14
SP8143-2008

Product Limited Warranty
U.S. & Canada Only
LIMITED WARRANTY
One Year Parts and Labor
AccuTemp Products, Inc. (AccuTemp) warrants that your AccuTemp equipment will be
free of defects in material and workmanship under normal use for a period of twelve (12)
months from installation or fifteen (15) months from date of shipment from AccuTemp,
whichever date first occurs (the Warranty Period). Registration of AccuTemp equipment
is required at the time of installation. Damage to AccuTemp equipment that occurs
during shipment must be reported to the carrier, and is not covered under this warranty.
The reporting of any damage during shipment is the sole responsibility of the
commercial purchaser/user of such AccuTemp equipment.
AccuTemp provides an active service department, which should be contacted and
advised of service issues, regardless of the warranty period. During the warranty period,
AccuTemp agrees to repair or replace, at its option, F.O.B. factory, any part which proves
to be defective due to defects in material or workmanship, provided the equipment has
not been altered in any way and has been properly installed, maintained, and operated in
accordance with the instructions in the AccuTemp Owner’s Manual. During the warranty
period, AccuTemp also agrees to pay for any factory authorized equipment service
agency (within the continental United States and Canada) for reasonable labor required
to repair or replace, at our option, F.O.B. factory, any part which proves to be defective
due to defects in materials or workmanship, provided the service agency has received
advance approval from AccuTemp to perform the repair or replacement. This warranty
includes travel time not to exceed two hours and mileage not to exceed 50 miles (100
miles round trip), but does not include post start-up assistance or training, tightening of
loose fittings or external electrical connections, minor adjustments, maintenance,
gaskets or cleaning. AccuTemp will not reimburse the expense of labor required to
replace parts after the expiration of the warranty period.
Proper installation is the responsibility of the dealer, owner-user, or installing contractor
and is not covered by this warranty. Improper installation can affect your warranty.
Installation is the responsibility of the Dealer, Owner/User or the Installation Contractor.
See the Installation section of the Owner’s Manual. While AccuTemp products are built to
comply with applicable standards for manufacturers, including Underwriters Laboratories
(UL) and Underwriters Laboratories Sanitation requirements, it is the responsibility of the
owner and the installer to comply with any applicable local codes that may exist.
AccuTemp makes no other warranties or guarantees, whether expressed or implied,
including any warranties of performance, merchantability, or fitness for any particular
purpose. AccuTemp liability on any claim of any kind, including negligence, with respect
to the goods and services covered hereunder, shall in no case exceed the price of the
goods and services, or parts thereof, which gives rise to the claim. In no event shall
AccuTemp be liable for special, incidental, or consequential damages, or damages in the
nature of penalties.
15
SP8143-2008

AccuTemp shall not be responsible for economic loss, profit loss, including without
limitation, losses or damages arising from food or product spoilage claims, whether or
not, they were cause by refrigeration failure.
This constitutes the entire warranty, which supersedes and excludes all other warranties,
whether written, oral, or implied.
This warranty is exclusive and in lieu of all other warranties expressed or implied,
including any warranty of merchantability and fitness for a particular purpose.
AccuTemp does hereby exclude and shall not be liable to purchaser for any
consequential or incidental damages.
16
SP8143-2008

ACCU TEMP GRIDDLE STAND 48" X 33.75" GAS & ELECTRIC
MODEL: RB48
PART DESCRIPTION QTY MODEL NO.
EVAPORATOR COIL 1 BBM 11
EXP. VALVE 404A 1 EFS1/4-C
CONDENSING UNIT 1/4HP-404 1 M6PM-H025-IAA-028
FILTER DRYER 1 C-052-S
SITE GLASS 1 SA-12-S
DIGITAL TEMPERATURE CONTROL 1 318-9288
TEMPERATURE CONTROL PROBE 2 2013012
MAGNETIC GASKETS 2 31-1/16X7-13/16
STAINLESS DRAWER SLIDES 24" 2 S52-0024
Gray ALUMINUM HANDLE HOLDER 2 P49-1010
4" CASTERS 250 LBS CAPACITY 2 4" CMPI-3PPB
4" CASTERS 250 LBS CAPACITY 2 4" CMPI-3PBB W/BRAKES
ACCU TEMP GRIDDLE STAND 36" X 33.75" GAS & ELECTRIC
MODEL: RB36
PART DESCRIPTION QTY MODEL NO.
EVAPORATOR COIL 1 BBM 11
EXP. VALVE 404A 1 EFS1/4-C
CONDENSING UNIT 1/4HP-404 1 M6TM-0022-IAA-118
FILTER DRYER 1 C-052-S
SITE GLASS 1 SA-12-S
DIGITAL TEMPERATURE CONTROL 1 318-9288
TEMPERATURE CONTROL PROBE 2 2013012
MAGNETIC GASKETS 2 24-13/16X7-13/16
STAINLESS DRAWER SLIDES 24" 2 S52-0024
Gray ALUMINUM HANDLE HOLDER 2 P49-1010
4" CASTERS 250 LBS CAPACITY 2 4" CMPI-3PPB
4" CASTERS 250 LBS CAPACITY 2 4" CMPI-3PBB W/BRAKES
Parts
SP8143-2007
17
SP8143-2008

ACCU TEMP GRIDDLE STAND 48" X 33.75" GAS & ELECTRIC
MODEL: FB48
PART DESCRIPTION
QTY
MODEL NO.
EVAPORATOR COIL
1
BBL 10
EXP. VALVE 404A
1
EFS1/4-C ZP
CONDENSING UNIT 1/4HP-404
1
M6TL-0037-IAA-177
FILTER DRYER
1
C-052-S
SITE GLASS
1
SA-12-S
DIGITAL TEMPERATURE CONTROL
1
318-9316
TEMPERATURE CONTROL PROBE
2
2013012
MAGNETIC GASKETS
2
31-1/16X7-13/16
STAINLESS DRAWER SLIDES 24"
2
S52-0024
Gray ALUMINUM HANDLE HOLDER
2
P49-1010
4" CASTERS 250 LBS CAPACITY
2
4" CMPI-3PPB
4" CASTERS 250 LBS CAPACITY
2
4" CMPI-3PBB W/BRAKES
ACCU TEMP GRIDDLE STAND 36" X 33.75" GAS & ELECTRIC
MODEL: FB36
PART DESCRIPTION
QTY
MODEL NO.
EVAPORATOR COIL
1
BBL 10
EXP. VALVE 404A
1
EFS1/4-C ZP
CONDENSING UNIT 1/4HP-404
1
M6TL-0029-IAA-188
FILTER DRYER
1
C-052-S
SITE GLASS
1
SA-12-S
DIGITAL TEMPERATURE CONTROL
1
318-9316
TEMPERATURE CONTROL PROBE
2
2013012
MAGNETIC GASKETS
2
24-13/16X7-13/16
STAINLESS DRAWER SLIDES 24"
2
S52-0024
Gray ALUMINUM HANDLE HOLDER
2
P49-1010
4" CASTERS 250 LBS CAPACITY
2
4" CMPI-3PPB
4" CASTERS 250 LBS CAPACITY
2
4" CMPI-3PBB W/BRAKES
SP8143-2007
18
SP8143-2008

WIRE DIAGRAM APPLIES TO DRAWER ASSEMBLY ONLY
CABINET
PROBE
EVAP
PROBE
0
o□D
o□D
o□D
oO
L N L COMP
6 17 I 8 19
l�
0
z5
0�
>
gllllllll
SELF-CONTAINED
REFRIGERATOR- DIXELL ELEC CONTROL!
BLOWER WITH STANDARD MOTOR
°
I
DO

ALL DIMENSIONS ARE B DIMENSIONS UNLESS NOTED
PICAL ENTIRE JOB).
12 11 10 9
WIRE DIAGRAM APPLIES TO DRAWER ASSEMBLY ONLY
8765 43 2 1
L L N L
ELECTRONIC CONTROL
N
0
a
z
0
z5
0�
>
g
SELF-CONTAINED
FREEZER- DIXELL
ELECTRONIC CONTROL
°
7/1/2020
1 OF 1
11x17
SP8143-2007
20
SP8143-2008
This manual suits for next models
3
Table of contents
Other AccuTemp Commercial Food Equipment manuals