Configuration and cabling
9ADIP
Installation Guide
System
description
Installation
parameters
Events
Accessories
Configuration
and cabling
Tables
Data
Compatible
elements
Functions
description
Delete
Supervision
Reader
Connexion
nº2
The reader can be powered by the + and -
Vout terminals (12v DC - 500mA max).
The controller can receive the reader in
Wiegand or Clock & Data formats via the W0-
CK and W1-DT terminals.
Fresh out of the factory:
The IN4 (PB2) input - C is dedicated to the
door control (relay 2) by pushbutton normally
open when it is not in use.
The IN5 (G2) input - C is dedicated to the
supervision of the door by normally closed
magnetic contact.
The IN6 (I2) input - C is dedicated to the read-
ing by sensor, normally open when it is not in
use. When the sensor switches to the nor-
mally closed state, the reading is no longer
possible.
W1
DT
Vout
- +
G2
IN5
I2
IN6 C
PB2
IN4
W0
CK
Door relay 1
The relay N ° 1 is a programmable relay 5A
under 30Vdc, dedicated to door control 1 as
it left the factory.
It can be controlled by time range, input func-
tion, by badge, PB-1 push putton input. It can
operate in timed mode, on - off or tracking of
an input.
Door relay 2
The relay N ° 2 is a programmable relay 5A
under 30Vdc, dedicated to door control 2 as
it left the factory.
It can be controlled by time range, input func-
tion, by badge, PB-2 push putton input. It can
operate in timed mode, on - off or tracking of
an input.
Optional
relay 3
The relay N° 3 is a programmable relay 5A at
30Vdc.
It can be controlled by time range, input func-
tion, by badge. It can operate in timed mode,
on - off or tracking of an input.
Optional
relay 4
The relay N° 4 is a 5A programmable relay at
30Vdc.
It can be controlled by time range, input func-
tion, by badge. It can operate in timed mode,
on - off or tracking of an input.
Connector
RJ45
RJ45 female connector dedicated to local or
remote communication with a computer or
with the ADIP network.
Connector
RJ45
RJ45 female connector dedicated to local or
remote communication with a computer or
with the ADIP network.
Battery Type CR2032 for maintaining the calendar
Programma-
tion bridge
Performs NEXT procedures:
- Recover factory passwords
- DHCP Addressing
- Reset Factory
Red warming
light Indicates the different configuration phases DL1