STEP 3
STEP 4
STEP 5
Page. 3
LIMITS ARE NOW SET
FOR AUTOMATE Q S45 & S60 MOTOR ONLY SET FAVOURITE POSITION
a. Set desired lower limit posion (using UP and DOWN buons).
b. If needed, put motor in Stepping Mode by pressing
P2 while motor is moving.
c. Once blind is at desired posion, press STOP for 5 seconds unl
motor confirms posion.
To co nfirm limit, motor will jolt down and up.
It is possible to programme mulƟple motors on each channel.
To program another motor on the same channel, turn OFF motor 1, turn ON motor 2 and repeat steps from 1 to 5.
a. Press P2 buon (x1).
b. Press UP buon (x1).
c. Press P2 buon (x1).
To co nfirm seƫng mode, motor will beep 3 Ɵmes and jolt up and down.
P2 (x1) UP (x1) P2 (x1)
SET UPPER LIMIT FIRST
*To program an A50/C Motor go to Step 5
a. Set desired upper limit posion first (using UP and DOWN buons).
b. When a more accurate seng is required put motor in
Stepping Mode by pressing P2 while motor is moving up/down.
c. Once blind is at desired posion, press STOP for 5 seconds unl
motor confirms posion.
To co nfirm limit, motor will jolt down and up.
UP (x1) Hold STOP for 5 sec
SET LOWER LIMIT
DOWN (x1) Hold STOP for 5 sec
TO SEND BLIND TO FAVOURED POSITION,
PRESS THE STOP BUTTON FOR 5 SECONDS. Hold STOP for 5 secUP/DOWN
PUT MOTOR IN LIMIT SETTING MODE
• Use UP and DOWN to find your favourite posion.
• Press STOP for 5 seconds unl motor confirms posion.
To co nfirm limit, motor will jolt.
UP
DOWN
OWN
x1
UP
x1
UP
x1
l
T
P f
r
l
T
P f
r
2
x1
2
x1